• Title/Summary/Keyword: ML 검출

Search Result 521, Processing Time 0.025 seconds

Quantitative Alpha Fetoprotein Detection with a Piezoelectric Microcantilever Mass Sensor (압전 마이크로캔틸레버 질량센서를 이용한 정량적 알파태아단백 검출)

  • Lee, Sangk-Yu;Cho, Jong-Yun;Lee, Yeol-Ho;Jeon, Sang-Min;Cha, Hyung-Joon;Moon, Wonk-Yu
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.31 no.5
    • /
    • pp.487-493
    • /
    • 2011
  • Alpha fetoprotein(AFP), which is serological marker for hepatocellular carcinoma, was quantitatively measured by its normal concentration, 10 ng/ml, with a label-free piezoelectric microcantilever mass sensor. The principle of detection is based on changes in the resonant frequency of the piezoelectric microcantilever before and after target molecules are attached to it, and its resonant frequency is measured electrically using a conductance spectrum. The resonant frequency of the developed sensor is approximately 1.34 MHz and the mass sensitivity is approximately 175 Hz/pg. The sensor has high reliability as mass sensor by reducing the effect of surface stress on resonant frequency due to attached proteins. 'Dip and dry' technique was used to react the sensor with reagents for immobilizing AFP antibody on the sensor and detecting AFP antigen. The measured mass of the detected AFP antigen was 6.02 pg at the concentration of 10 ng/ml, and 10.67 pg at 50 ng/ml when the immunoreaction time was 10 min.

The Controlling Activity of Several Fungicides against Rice Bakanae Disease Caused by Fusarium fujikuroi in Five Assay Methods (몇 가지 살균제의 벼 키다리병과 병원균에 대한 효과 검정)

  • Shin, Myeong-Uk;Lee, Su-Min;Lee, Yong-Hwan;Kang, Hyo-Jung;Kim, Heung-Tae
    • The Korean Journal of Pesticide Science
    • /
    • v.12 no.2
    • /
    • pp.168-176
    • /
    • 2008
  • Recently damage of rice bakanae disease disseminated by infected seeds increased in paddy field in Korea. For controlling rice bakanae disease, the efficacy of 17 fungicides was assessed by 5 kinds of bioassay, spore germination test (SGT), mycelial growth test, detection test on Komada's medium (KDT), pouch test (PT) and greenhouse test (GT). Among ergosterol biosynthesis inhibiting fungicides, prochloraz showed a high controlling activity in all the assay systems while the others showed very low activity except for $500\;{\mu}g/ml$ of hexaconazole in GT and $500\;{\mu}g/ml$ of triflumizole in KDT. Although benomyl and the mixture of benomyl and thiram showed a good activity at 100 and $500\;{\mu}g/ml$ in SGT and PT, respectively, in GT they did a middle activity. Trifloxystrobin and kresoxim-methyl included in strobilurins showed a good activity even at $20\;{\mu}g/ml$ in KDT as well as a middle activity in SGT. Also a high activity not only at $10\;{\mu}g/ml$ in SGT but also at $100\;{\mu}g/ml$ KDT was detected in thiram. The activity of fludioxonil was confirmed in SGT, KDT and PT. Based on these results, it is very important to determine a bioassay system, because the fungicidal activity against rice bakanae disease was fluctuated depending on a assay systems as well as the mechanism of fungicide.

HPLC를 이용한 축육(Pork Muscle)내의 Dihydrostreptomycin 검출법

  • Choe, Ji-Hyeon;Han, Eun-Yeong;Park, Jin-Gwan;Lee, Su-Yeon;Choe, Dong-Mi;Sin, Ho-Cheol;Lee, Chi-Ho
    • Proceedings of the Korean Society for Food Science of Animal Resources Conference
    • /
    • 2005.10a
    • /
    • pp.196-203
    • /
    • 2005
  • 축산식품 고기내의 잔류항생물질을 신속하고 간편하고 정확하게 분석하기 위한 시험법 개발 을 목적으로 하였다. 축산식품내의 일반적인 잔류항생물질에 대한 지금까지의 분석법으로는 Bioassay법, TLC법, ELISA법, GC법 및 HPLC법 등이 있지만 Streptomycin/Dihydro streptomycin, Neomycin에 대한 HPLC법은 거의 확립되어 있지 않은 실정이다. 우리나라의 공인 검사법으로는 Bioassay법 및 HPLC법 등이 있지만 그러나 지금까지의 방법으로는 검출감도가 낮은 것이 큰 문제점으로 되어 왔다. 본 연구에서는 DST에 대한 HPLC법에 대한 보고한 P. Edder 방법 중에 clean-up과정 및 이동상 조건을 대폭 수정하여 DST의 분리 및 검출감도를 낮추려고 시도하였다. 본 연구에 사용된 유도체화 장치 Post-Column Derivatization Instrument PCX 5100 (Pickering Laboratories, Inc.)의 컬럼온도는 $40^{\circ}C$, 오븐온도 $55^{\circ}C$, reagent 유속 0.6ml/min mobile phase 유속 0.8ml/min으로 검출기는 형광검출기를 이용하여 DST 검출에 대해 만족할 만한 결과를 얻었다. 이때의 분석소요시간은 약 15분이었다. 표준시료 DST의 검량선은 넓은 농도범위(0.02${\sim}$1.0ppm)에서 양호한 직선성을 나타냈다. 본 시험법에 의한 검출한계는 limit of detection (LOD)은 0.02ppm이었으며, 적어도 고기에서의 MRL이 0.6ppm임을 감안하면 DST를 정량적으로 정도 좋게 측정할 수 있다는 것을 확인했다. 상기의 조건하에서 실제시료인 고기에 표준 DST를 1ppm을 spiking한 후 SPE상에서 SCX(Strong cation exchange column)을 통한 clean-up과정을 거친 후의 DST의 limit of quantification(LOQ)는 약 0.47ppm이었으며, 이에 대한 회수율은 97.7%(n= 8)를 나타냈다. 실제 codex에서 권장한 고기의 MRL이 0.6ppm인 점을 감안하면 codex 권고치에 도달할 수 있는 것으로 판단되었다. 따라서 본 연구에서 개발된 시험법은 지금까지 국내적으로 DST에 대한 시험법이 확립되어 있지 않은 것으로 이와 아울러 간편한 parallux와 병용해 DST에 대한 정량 및 정성 분석을 유도체화 장치 및 형광검출기를 이용해 잔류항생물질 DST에 대한 분석시험법의 개발이 가능하다고 여겨진다.

  • PDF

Relationship between Microflora and Environmental Factors in Groundwater (지하수 미생물과 환경요인의 상호관계)

  • 안연준;민병례;최영길
    • Journal of the Korean Society of Groundwater Environment
    • /
    • v.2 no.2
    • /
    • pp.85-92
    • /
    • 1995
  • This study was conducted to find out the relationship between microflora in groundwater and its physico-chemical environmental factors at the 59 sites, where distributed at 3 cities and 18 counties in Jeonranam-Do, Korea. The average values of environmental factors were as followings; pH 6.9, temperature 20.1 $^{\circ}C$, dissolved oxygen 6.5 mg/1, the depth of wells 80.1 m, and nitrate 10.7 mg/1. The average value of microbial population size; Heterotrophic bacteria-NA (HPC-NA) and heterotrophic bacteria-YEPD (HPC-YEPD) were 1.4${\times}$10$^3$CFU/ml and 0.59${\times}$10$^3$ CFU/ml respectively HPC-YEPD numbers were 42.1% of HPC-YEPD. Coliform bacteria were detected at 16 sites, and its average numbers were 6.7 CFU/ml. General fungi were detected at 14 sites, and its had average numbers were 3.9 CFU/ml. The correlation coefficient was calculated value as relation index between the microbial population sizes and environmental factors in groundwater. In case of HPC-NA, the correlation coefficient value with dissolved oxygen was 0.087 But it showed negative correlation coefficient with other factors. In case of HPC-YEPD, the correlation coefficient value with pH, temperature and nitrate were 0.0957, 0.0019 and 0.0151 respectively. It was concluded that the population size of HPC-NA were influenced by the order of temperature, dissolved oxygen, pH and the depth of wells and that HPC-YEPD were influenced by the order of pH, dissolved oxygen, nitrate, the depth of wells and temperature.

  • PDF

Stydies on the Selective Screening Method of Bifidobacteria Used in Yoghurt (호상 요구르트 제품에 이용되는 Bifidobacteria 의 선택적 검출 방법)

  • 박희경;허태련
    • Microbiology and Biotechnology Letters
    • /
    • v.23 no.2
    • /
    • pp.214-219
    • /
    • 1995
  • In fermentation of dairy products, bifidobacteria is used in conjunction with other lactic acid bacteria, such as L. acidophilus, L. bulgaricus and S. thermophilus, rendering the enumeration of bifidobacteria difficult. In order to develop optimum conditions for selective enumeration of bifidobacteria, we examined MIC of several antibiotics against various bifidobacteria and other lactic acid bacteria. The growth of L. acidophilus, L. bulgaricus and S. thermophilus were inhibited by lithium chloride at the concentration of less than 4 mg/ml, whereas growth inhibition of bifidobacteria occurred at concentrations over 6-10 mg/ml. Tetracycline and chloramphenicol were also found to selectively inhibit growth of other lactic acid bacteria at the concentration of 1-3 $\mu$g/ml. Addition of 6 mg/ml lithium chloride, 1 $\mu$g/ml, tetracycline or 3 $\mu$g/ml chloramphenicol to medium was found to be optimal for selective enumeration of bifidobacteria. By using these three inhibitory chemicals in the TPY medium, higher number of bifidobacteria were selectively isolated than with NPNL agar and LP agar.

  • PDF

A simple computational algorithm of ML optimum multiuser detector for synchronous code division multiple access channels (동기화된 부호 분할 다원 접속 채널을 위한 ML 최적 다중 사용자 검출기의 간단한 계산 알고리즘)

  • 권형욱;최태영;오성근
    • Journal of the Korean Institute of Telematics and Electronics A
    • /
    • v.33A no.5
    • /
    • pp.1-9
    • /
    • 1996
  • In this paper, we propose an efficient computational algorithm that can reduce significantly the computational complexity of the ML optimum multiuser detector known as the most excellent detector in synchronous code division multiple access channels. The proposed detector uses the sequential detection algorithm based on the alternating maximization appraoch to obtain the ML estimates. As initial estimates for this sequential algorithm, we can use the estimated values obtained by the conventional single-user detector, the linear decorrelating multiuser detector, or the decorrelating decision-feedback muliuser detector, the linear decorrelating multiuser detector, or the decorrelating decision-feedback multiuser detector. We have performed computer simulations in order to see the convergence behaviors and the detection performance of the propsoed algorithm in terms of initial algorithms and the number of users, and then to compare the computational complexity with that of the ML optimum multiuser detector. From the results, we have seen that the proposed alternating maximization detector has nearly equal detction performance with that of the ML optimum multiuser detctor in only a few iteration.

  • PDF

Soft-Decision Algorithm with Low Complexity for MIMO Systems Using High-Order Modulations (고차 변조 방식을 사용하는 MIMO 시스템을 위한 낮은 복잡도를 갖는 연판정 알고리즘)

  • Lee, Jaeyoon;Kim, Kyoungtaek
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.40 no.6
    • /
    • pp.981-989
    • /
    • 2015
  • In a log likelihood ratio(LLR) calculation of the detected symbol, multiple-input multiple-output(MIMO) system applying an optimal or suboptimal algorithm such as a maximum likelihood(ML) detection, sphere decoding(SD), and QR decomposition with M-algorithm Maximum Likelihood Detection(QRM-MLD) suffers from exponential complexity growth with number of spatial streams and modulation order. In this paper, we propose a LLR calculation method with very low complexity in the QRM-MLD based symbol detector for a high order modulation based $N_T{\times}N_R$ MIMO system. It is able to approach bit error rate(BER) performance of full maximum likelihood detector to within 1 dB. We also analyze the BER performance through computer simulation to verify the validity of the proposed method.

Simultaneous Determination of Antioxidant(BHA, BHT) and Insecticide(Fenvalerate, Allethrin) by Liquid Liquid Extraction-GC/MS (Liquid Liquid Extraction-GC/MS에 의한 항산화제(BHA, BHT) 및 살충제(Fenvalerate, Allethrin)의 동시분석)

  • Lee, Jae-Hee;Bae, Jun-Hyun;Kang, Jun-Gill;Kim, Youn-Doo
    • Journal of the Korean Chemical Society
    • /
    • v.47 no.6
    • /
    • pp.559-568
    • /
    • 2003
  • A procedure based on liquid liquid extraction(LLE)-GC/MS has been developed for the simultaneous analysis of antioxidants and insecticides known as endocrine disrupters. The endocrine disrupters investigated in this study are butylated hydroxy anisole(BHA) and butylated hydroxy toluene(BHT), and the insecticides are allethrin and fenvalerate. The limit of detection(LOD) was 0.071~0.159 ng/ml with RSD of 1.41~5.34% for the standard sample. From water reservior of Han river, Geum river, Nakdong river and Sumjin river, these compounds were not detected. For the synthesized sample, the LOD is 0.051~0.132 ng/ml with RSD of 6.39~13.4%.

A Soft Demapping Method for 64-APSK in the DVB-S3 System (DVB-S3 시스템의 64-APSK 방식에 대한 연판정 비트 검출 기법)

  • Li, Guowen;Zhang, Meixiang;Kim, Sooyoung
    • Journal of Satellite, Information and Communications
    • /
    • v.9 no.2
    • /
    • pp.23-27
    • /
    • 2014
  • In this paper, we propose a soft demapping method for 64-ary APSK in the DVB-S3 system. The proposed method in this paper uses the hard decision threshold (HDT) line for each constituent bit in a symbol, and calculates the soft bit information with the distance between the HDT line and the detected symbol. If the HDT lines are defined in a simple manner, the complexity to estimate soft information can be largely reduced compared with the maximum likelihood detection (MLD) which has an exponential complexity. By considering this, we first derive HDT lines for each constituent bit for a 64-APSK symbol, and propose a method to calculate soft bit information. We simulate the BER performance of the proposed scheme by using a turbo codes which requires soft-input-soft-output information, and compare it that of the MLD. The result show that the proposed scheme produces approximating performance to MLD with largely reduced complexity.

Evaluation of reverse transcriptase loop-mediated isothermal amplification (RT-LAMP) assay for detection of infectious hematopoietic necrosis virus (IHNV) (Infectious hematopoietic necrosis virus (IHNV)-검출 Reverse transcriptase loop-mediated isothermal amplification (RT-LAMP) 법의 평가)

  • Kim, Wi-Sik;Jeon, Chan-Hyeok;Kim, Jeong-Ho;Oh, Myung-Joo
    • Journal of fish pathology
    • /
    • v.25 no.3
    • /
    • pp.257-262
    • /
    • 2012
  • A reverse transcriptase loop-mediated isothermal amplification (RT-LAMP) assay was evaluated to monitor infectious hematopoietic necrosis virus (IHNV) from artificially infected rainbow trout Oncorhynchus mykiss. The cumulative mortalities of fish challenged with IHNV at $10^{6.5}\;TCID_{50}$/fish, $10^{5.5}\;TCID_{50}$/fish and $10^{4.5}\;TCID_{50}$/fish were 40%, 0% and 0%, respectively. Dead fish and survivors at 16 and 28 d post-challenge in each group were employed for IHNV detection by RT-LAMP assay and virus isolation using BF-2 cells. IHNV from $10^{4.3}$ to $10^{6.8}\;TCID_{50}/ml$ was isolated from all the dead fish and also detected in all of the examined dead fish by RT-LAMP assay. In survivors at 16 d, 60% (3/5 fish, $10^{2.8}-10^{5.05}\;TCID_{50}/ml$), 20% (1/5 fish, $10^{1.05}\;TCID_{50}/ml$) and 60% (3/5 fish, $10^{1.05}-10^{4.8}\;TCID_{50}/ml$) were found to be IHNV-positive by virus isolation in fish challenged with IHNV at $10^{6.5}\;TCID_{50}$/fish, $10^{5.5}\;TCID_{50}$/fish and $10^{4.5}\;TCID_{50}$/fish, respectively, while 20% (1/5 fish), 0% (0/5 fish) and 20% (1/5 fish) were IHNV-positive by RT-LAMP assay. No IHNV was detected in the survivors at 28 d and control fish. These results indicate that the RT-LAMP assay is useful for detection of IHNV in diseased fish although it is not enough to monitor virus in IHNV-survivors.