• Title/Summary/Keyword: MK Test

Search Result 81, Processing Time 0.023 seconds

EVALUATION OF THE APPLICABLE REACTIVITY RANGE OF A REACTIVITY COMPUTER FOR A CANDU-6 REACTOR

  • Lee, Eun Ki;Park, Dong Hwan;Lee, Whan Soo
    • Nuclear Engineering and Technology
    • /
    • v.46 no.2
    • /
    • pp.183-194
    • /
    • 2014
  • Recently, a CANDU digital reactivity computer system (CDRCS) to measure the worth of the liquid zone controller in a CANDU-6 was developed and successfully applied to a physics test of refurbished Wolsong Unit 1. In advance of using the CDRCS, its measureable reactivity range should be investigated and confirmed. There are two reasons for this investigation. First, the CANDU-6 has a larger reactor and smaller excore detectors than a general PWR and consequently the measured reactivity is likely to reflect the peripheral power variation only, not the whole core. The second reason is photo neutrons generated from the interaction of the moderator and gamma-rays, which are never considered in a PWR. To evaluate the limitations of the CDRCS, several tens of three-dimensional steady and transient simulations were performed. The simulated detector signals were used to obtain the dynamic reactivity. The difference between the dynamic reactivity and the static worth increases in line with the water level changes. The maximum allowable reactivity was determined to be 1.4 mk in the case of CANDU-6 by confining the difference to less than 1%.

Measurement of Youth Financial Literacy and Implications in Korea

  • CHOI, Byoung-Il;KIM, Jae-Jin
    • The Journal of Economics, Marketing and Management
    • /
    • v.10 no.1
    • /
    • pp.1-14
    • /
    • 2022
  • Purpose: The purpose of this study is to analyze the measurement results of the financial comprehension test conducted ten times in order to study the financial comprehension. Research design, data, and methodology: In this study, correct answer rates in the Economics and Finance Literacy Certification Test were analyzed across ten rounds of tests taken by 6,662 high school students in Korea. Result: The analysis revealed that Korean high school students' level of financial literacy generally increased as the grade level increased, and the correct answer rates of students at autonomous high schools and special-purpose high schools were statistically different from those of students at general academic high schools and specialized high schools. Conclusion: We can therefore infer that students at specialized high schools face limitations in tackling financial problems due to their lack of proficiency in interpretation and calculation of data necessary for real life financial decision-making. In contrast, students at general academic high schools, special-purpose high schools, and autonomous high schools who do not learn finance as a part of their official curriculum at school were lacking in basic financial knowledge as well as knowledge about the financial system compared to students at specialized high schools, highlighting the need for a measure to address the deficiency.

EVALUATION OF BONE RESPONSE BY RESONANCE FREQUENCY ANALYSIS OF ANODIZED IMPLANTS

  • Roh Hyun-Ki;Heo Seong-Joo;Rhyu In-Chul
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.43 no.6
    • /
    • pp.745-750
    • /
    • 2005
  • Statement of problem. Resonance frequency analysis has been increasingly served as a non-invasive and objective method for clinical monitoring of implant stability. Many clinical studies must be required for standardized data using RFA. Purpose. This study was performed to evaluate RFA value changes in two anodized implant groups. Material and method. Among a total of 24 implants, twelve screw shaped implants as a test group (H2-R8.5) were manufactured, which had a pitch-height of 0.4 mm, an outer diameter of 4.3 mm, a length of 8.5 mm, and external hexa-headed, were turned from 5 mm rods of commercially pure titanium (ASTM Grade IV, Warantec Co., Seoul, Korea), and another twelve implants as a control group were $Br{\aa}nemark$ Ti-Unite MK4 (diameter 4.0 mm, length 8.5 mm). Each group was installed in tibia of rabbit. Two implants were placed in each tibia (four implants per rabbit). Test two implants were inserted in right side and control two in left side. ISQ values were measured using $Osstell^{TM}$ (Integration Diagnostics Ltd. Sweden) during fixture installation, and 12 weeks later and evaluated the RFA changes. Results. Mean and SD of baseline ISQ values of test group were $75.0{\pm}3.4$ and $68.7{\pm}8.1$ for control group. Mean and SO of ISQ values 12 weeks after implant insertion were $73.2{\pm}4.7$ for test group and $72.6{\pm}3.9$ for control group. There were no statistically significant differences between groups in ISQ values after 3 months (P>0.05). From the data, RFA gains after 3 months were calculated, and there was statistically significant difference between groups (P<0.05). Conclusion. Although there were RFA changes between groups, implant stability after experimental period shows alike tendency and good bone responses.

Characteristics of the High Speed Shear Test for Sn-3.0wt.%Ag-0.5wt.%Cu Solder Ball Joints (Sn-3.0wt.%Ag-0.5wt.%Cu 솔더 볼 접합부의 고속전단 특성)

  • Lee, Young-Gon;Lee, Hee-Yul;Moon, Jeong-Tak;Park, Jai-Hyun;Han, Shin-Sik;Jung, Jae-Pil
    • Korean Journal of Metals and Materials
    • /
    • v.47 no.9
    • /
    • pp.580-585
    • /
    • 2009
  • The effects of shear speed and tip height on the high speed shear test of Sn-3.0wt.%Ag-0.5wt.%Cu ball joints were investigated. Solder balls of $450{\mu}m$ in diameter were reflowed at $245^{\circ}C$ on a FR4 PCB (Printed Circuit Board) in order to obtain a sample for the high-speed shear test. The UBM was comprised of Cu/Ni/Au, and the shear speed and tip height varied from 0.5 to 3.0 m/s, and from 10 to $135{\mu}m$, respectively. According to the experimental results, faster shear speed enhanced the shear strength of the solder joints, regardless of the tip height. The fraction of ductile (solder) fracture decreased when the shearing speed was raised from 0.5 to 3.0 m/s. With an increasing tip height from 10 to 50 and $135{\mu}m$, the fracture mode changed from pad lift to mixed (ductile and brittle) and ductile fracture, respectively, while the shearing energy also increased in the same order. The shear energy had a proportional relationship with the fraction of the solder fracture.

Stability measurements on the implants of mandibular molar area using OsstellTM (OsstellTM을 이용한 하악구치부 임플랜트의 안정성 측정)

  • Park, Chan-Jin
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.17 no.3
    • /
    • pp.205-211
    • /
    • 2001
  • The aim of this investigation was to evaluate successfully functioning implants stability in the partially edentulous mandibular molar sites by resonance frequency measurements. Resonance frequency measurement is more objective and clinically non-invasive method than any other methods had been used. In this study, $Osstell^{TM}$ (Integration Diagnostics, Sweden) was used. 15 patients ( 7 males, 8 females ) were received each 2 implants in their mandibular unilaterally partial edentulous molar sites. Total 30 implants were installed, 28 implants were $Br{\aa}nemark^{(R)}$ self-tapping fixtures(MK II, Nobel Biocare, Sweden) and 2 were $3i^{(R)}$(USA) self-tapping fixtures. Minimum of functional loading durations was 12 months and there were no significant marginal bone resorptions and peri-implant problems. From this test, the following results were drawn: 1. Mean ISQ values of implants in the first and second mandibular molar area were $73.66{\pm}4.45$, $71.93{\pm}3.41$, respectively. There was no significant difference between two groups(p>0.05). Also mean ISQ value of total sum was 72.8. 2. Mean ISQ values of implants in males and females group were $71.64{\pm}4.06$, $73.81{\pm}3.76$, respectively. And there was no significant difference between two group(p>0.05). 3. Correlation between implant lengths and ISQ values was weak(r=0.128).

  • PDF

Trajectory Planning for Industrial Robot Manipulators Considering Assigned Velocity and Allowance Under Joint Acceleration Limit

  • Munasinghe, S.Rohan;Nakamura, Masatoshi;Goto, Satoru;Kyura, Nobuhiro
    • International Journal of Control, Automation, and Systems
    • /
    • v.1 no.1
    • /
    • pp.68-75
    • /
    • 2003
  • This paper presents an effective trajectory planning algorithm for industrial robot manipulators. Given the end-effector trajectory in Cartesian space, together with the relevant constraints and task specifications, the proposed method is capable of planning the optimum end-effector trajectory. The proposed trajectory planning algorithm considers the joint acceleration limit, end-effector velocity limits, and trajectory allowance. A feedforward compensator is also incorporated in the proposed algorithm to counteract the delay in joint dynamics. The algorithm is carefully designed so that it can be directly adopted with the existing industrial manipulators. The proposed algorithm can be easily programmed for various tasks given the specifications and constraints. A three-dimensional test trajectory was planned with the proposed algorithm and tested with the Performer MK3s industrial manipulator. The results verified effective manipulator performance within the constraints.

A study on the Early-Strength Properties of Mortar according to the Kinds and Replacement Ratio of Mineral Admixture (혼화재 종류 및 치환율에 따른 모르터의 조기강도 특성에 관한 연구)

  • Choi, Se-Jin;Lee, Seong-Yeun;Kim, Sung-Su
    • Journal of the Korea Institute of Building Construction
    • /
    • v.7 no.2 s.24
    • /
    • pp.59-65
    • /
    • 2007
  • Recently, due to the increase of high-rise buildings construction, many researches for making harden of concrete earlier and remove of forms faster are being performed to reduce construction period. In this study, we compared and analysed the early strength properties of mortar according to the kinds and replacement ratio of mineral admixture to select the kinds and replacement ratio of mineral admixture of high early strength concrete. For this purpose, mortar mixtures according to the kinds(FA, MK, ZR, BFS, DM) and replacement ratio(0, 2, 4% by volume of sand) of mineral admixture were selected. From our test data, early-age compressive strength decreased in accordance with the increase of replacement ratio of fly-ash(FA) & blast furnace slag powder(BSF) and, in case of addition admixture, early-age compressive strength of with containing 4% appeared higher compared with containing 2%.

Trend Test of the Mean and Extreme Sea Level Data in the Korean Coast (우리나라 연안의 평균해면 및 최극조위 자료의 추세 검정)

  • Kang, Ju-Whan;Cho, Hong-Yeon;Park, Min-Won;Park, Seon-Jung
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2008.05a
    • /
    • pp.2156-2160
    • /
    • 2008
  • 우리나라 연안의 평균해면이 증가하고 있다는 주장과 고극조위, 저극조위가 증가(또는 변동)하고 있다는 주장이 제기되고 있으나, 연구자가 사용한 자료의 기간 및 분석 방법 등에 차이가 있고, 결측자료(missing data) 및 이상자료(outlier) 등을 처리한 방법이 서로 차이가 있기 때문에 전체적으로 또는 부분적으로 분석결과가 차이를 보일 수 있다. 또한 추세분석에서는 통계적인 신뢰수준에 대한 검정과정 없이 단순하게 선형회귀곡선식을 이용하여 기울기의 부호만으로 증가 감소를 판단하는 경우도 있다. 그러나 추세분석은 최적의 추세곡선을 찾아내는 것 이전에 추세의 유무를 통계적인 신뢰수준을 기준으로 검정하는 것이 필요하다. 본 연구에서는 추세분석의 필수과정인 추세검정(추세가 있는가? 없는가?)을 Mann-Kendall 방법을 이용하여 우리나라 전 연안 조위관측소의 평균해수면 및 고극조위, 저극조위 자료에 대하여 수행하였다. 추세검정 결과를 다음과 같이 도출할 수 있었다. 평균해수면은 95% 유의수준으로 분석에 포함된 전체 30개 검조소 중 대산, 보령, 군산, 목포, 통영, 거문도, 부산, 가덕도, 제주, 서귀포, 속초, 포항, 울산, 울릉도 지점 등 19개 지점이 추세가 있는 것으로 파악되었으며, 고극조위, 저극조위는 각각 15개, 17개 지점이 추세가 있는 것으로 파악되었다.

  • PDF

전해에칭 및 양극산화를 이용한 알루미늄 소재 열전모듈 기판 제작

  • Choe, Lee-Taek;Son, In-Jun
    • Proceedings of the Korean Institute of Surface Engineering Conference
    • /
    • 2017.05a
    • /
    • pp.127-127
    • /
    • 2017
  • 열전모듈이란 온도차를 기전력으로 바꾸거나, 반대로 기전력으로 온도 차이를 만들어내는 모듈이다. 열전발전의 경우, 고열 부분의 열이 빠르게 방출되지 못하면 소자와 기판의 손상을 가져올 수 있기 때문에 열전모듈 기판의 방열성능은 매우 중요하다. 따라서 열전모듈이 실제 발전용으로 사용되기 위해서는 방열성이 높은 기판, 즉 열전도도가 높은 기판이 적용되어야 한다. 그러나 현재 일반적으로 사용되는 알루미나는 그 열전도도가 30 w/mK 정도밖에 되지 않아 그 방열성능이 많이 떨어진다. 이를 해결하기 위해 열전도도가 높은 소재를 베이스 기판으로 한 모듈이 연구되어져야 한다. 따라서 본 연구에서는 열전도도가 237 w/mk 정도로 높은 알루미늄을 기판으로 이용해 열전모듈 기판을 제조하고자 하였다. 이를 위해 알루미늄 베이스 기판 위에 전해에칭, 수화처리, 양극산화 및 전기동도금을 실시하였다. 알루미늄 상에 양극산화처리를 통하여 절연층 역할을 할 산화피막을 형성하고, 백금을 스퍼터링법으로 코팅해 전도성을 부여하였으며 그 이후 바로 전기 동 도금을 실시하였다. 또한 전처리 과정으로 전해에칭을 통해 표면의 조도를 증가시켰고 갈고리 효과를 통해 밀착력을 증가시키고자 하였다. 본 연구의 결과, 기판으로 사용하기 적합한 절연특성과 기판의 열전도도 측정을 통한 우수한 방열성능도 확인할 수 있었다. 뿐만 아니라 Cross Cut Adhesion Test를 통하여 밀착력도 우수하다는 것을 확인할 수 있었으며 표면과 단면관찰을 통해 목적대로 기판의 도금이 잘 이루어 졌다는 것을 알 수 있었다. 이러한 공정을 통해 제조된 열전모듈 기판은 우수한 방열성능을 통하여 열전모듈의 성능과 수명을 한층 더 높일 수 있을 것으로 기대된다.

  • PDF

The Effects of Cold Rolling on the Graphitization in Boron Addition High Carbon Steel (B첨가 고탄소강의 흑연화에 미치는 냉간압연의 영향)

  • Woo, K.D.;Park, Y.K.;Ryu, J.H.;Lee, C.H.;Ra, J.P.
    • Journal of the Korean Society for Heat Treatment
    • /
    • v.12 no.2
    • /
    • pp.99-107
    • /
    • 1999
  • The graphitization is affected by the addition of small amount of the elements(such as Si, Al, Ni, B, Cr and Mn etc.) and the pre-treatment(such as cold rolling). Boron is well known element to accelerate the graphitization of cementite in high carbon steels. Also, cold rolling is known to accelerate the graphitization. But the graphitization nucleation mechanism by cold rolling is few reported. Therefore the effect of cold rolling in Fe-0.5%C-1.0%Si-0.47%Mn-0.005%B steel on the graphitization is investigated quantitatively using hardness test, optical microscope and scanning electron microscope, neutron induced microscopic radiography. The nucleation of graphite in cold-rolled Fe-0.5%C-1.0%Si-0.47%Mn-0.005%B steel is formed at void which is formed at pearlite/pearlite boundary by cold rolling. But the effect of cold rolling on graphitization in boron addition steel is more effective than that of no boron addition steel due to segregation of BN at void in boron addition steel.

  • PDF