• Title/Summary/Keyword: MF 막여과

Search Result 62, Processing Time 0.025 seconds

Application of Ceramic MF Membrane at the Slow Sand Filtration Process (완속모래여과 공정에서 세라믹 MF 막의 적용)

  • Choi, Kwang-Hun;Park, Jong-Yul;Kim, Su-Han;Kim, Jeong-Sook;Kang, Lim-Seok
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.35 no.12
    • /
    • pp.877-882
    • /
    • 2013
  • The application of ultrafiltration (UF) and microfiltration (MF) membranes has been increased for drinking water purification. The advantages of UF/MF membrane process compared to conventional treatment processes are stable operation under varying feed water quality, smaller construction area, and automatic operation. Most membrane treatment plants are designed with polymeric membranes. Recently, some studies suggested that the process of treating surface water with ceramic membranes is competitive to the application of polymeric membranes. Higher water flux, less frequent cleaning, and much longer lifetime are the advantages of ceramic membrane comparing to polymeric membrane. Therefore, this research focused on the application of ceramic MF membrane pilot plant at the slow sand filtration plant. The ceramic membrane pilot plant has three trains that used raw water and sand filtered water as a feed water, respectively. For optimizing the pilot plant process, the coagulation with PACl coagulant was used as a pretreatment of ceramic membrane process. In addition, CEB (Chemical Enhanced Backwash) process using $H_2SO_4$ and NaOCl was used for 1.5 days, respectively. The experimental results showed that applying the optimum coagulant dose before membrane filtration showed enhancing membrane fluxes for both raw water and sand filtered water. Also, when using raw water as a feed of membrane, minimum fouling rate was 2.173 kPa/cycle with 25 mg/L of PACl and when using sand filtered water, the minimum fouling rate was 0.301 kPa/cycle with 5 mg/L of PACl.

Hybrid Water Treatment of Tubular Ceramic MF and Photocatalyst Loaded Polyethersulfone Beads : Effect of Organic Matters, Adsorption and Photo-oxidation at Nitrogen Back-flushing (관형 세라믹 정밀여과와 광촉매 첨가 PES 구의 혼성 수처리 : 질소 역세척 시 유기물 및 흡착, 광산화의 영향)

  • Hong, Sung Taek;Park, Jin Yong
    • Membrane Journal
    • /
    • v.23 no.1
    • /
    • pp.61-69
    • /
    • 2013
  • The effect of humic acid (HA), and the roles of microfiltration (MF), PES (polyethersulfone) beads adsorption, and photo-oxidation were investigated in hybrid process of ceramic MF and PES beads loaded with titanium dioxide ($TiO_2$) photocatalyst for advanced drinking water treatment. Those were compared and studied in viewpoints of membrane fouling resistance ($R_f$), permeate flux (J), and total permeate volume ($V_T$). Because membrane fouling increased dramatically as decreasing HA, $R_f$ increased and J decreased, and finally $V_T$ was the highest at 2 mg/L HA. In the experiment to investigate the roles of photo-oxidation and adsorption at humic acid 4 mg/L and 6 mg/L. In both conditions, $R_f$ was the lowest and $V_T$ was the highest in MF + $TiO_2$ + UV process. The average treatment efficiencies of turbidity and dissolved organic matters were the highest in MF + $TiO_2$ + UV process, too.

Removal Characteristics of Organic Matters in Pretreatment and Reverse Osmosis Membrane Processes for Seawater Desalination (해수담수화 전처리 및 역삼투막여과 공정의 유기물 제거특성)

  • Kim, Dong-Kwan;Choi, June-Seok;Lee, Chang-Kyu;Kim, Jinho;Choi, Jeong-Hak;Lee, Wontae
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.36 no.7
    • /
    • pp.492-497
    • /
    • 2014
  • This study investigated removal characteristics of organic matters in pretreatment and reverse osmosis (RO) membrane processes for seawater desalination. Also, the influence of the changes in characteristics of organic matters on the membrane fouling was assessed. The pretreatment processes included dual media filtration (DMF), pressurized membrane filtration (MF), and submerged membrane filtration (SMF). Turbidity, UV absorption at 254 nm, dissolved organic carbon, size exclusion chromatography (SEC), fluorescence excitation emission matrix (FEEM), and transparent exopolymer particles (TEP) in raw and processed waters were analyzed. Ions and minerals were not removed by any pretreatment process tested, but were removed over 99% through the RO membrane process. Hydrophobic organics, which can play major role in organic membrane fouling, were relatively readily removed compared with hydrophilic ones. Membrane based pretreatment such as MF and SMF exhibited better removals of organics than conventional DMF. As the levels of organics in pretreated water decreased, the silt density index (SDI) decreased. MF treated water exhibited the lowest SDI value; this is possibly due to the lowest TEP ($0.1-0.4{\mu}m$) concentrations.

A process diagnosis method for membrane water treatment plant using a constant flux membrane fouling model (정유량 막여과 파울링 모델을 이용한 막여과 정수 플랜트 공정 진단 기법)

  • Kim, Suhan
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.27 no.1
    • /
    • pp.139-146
    • /
    • 2013
  • A process diagnosis method for membrane water treatment plant was developed using a constant flux membrane fouling model. This diagnosis method can be applied to a real-field membrane-based water treatment plant as an early alarming system for membrane fouling. The constant flux membrane fouling model was based on the simplest equation form to describe change in trans-membrane pressure (TMP) during the filtration cycle from a literature. The model was verified using a pilot-scale microfiltraton (MF) plant with two commercial MF membrane modules (72 m2 of membrane area). The predicted TMP data were produced using the model, where the modeling parameters were obtained by the least square method using the early plant data and modeling equations. The diagnosis was carried out by comparing the predicted TMP data (as baseline) and real plant data. As a result of the case study, the diagnsis method worked pretty well to predict the early points where fouling started to occur.

Use of a Combined Photocatalysis/Microfiltration System for Natural Organic Matter Removal (광촉매 반응과 침지형 정밀여과를 이용한 자연산 유기물의 제거)

  • 추광호;박경원;김문현
    • Membrane Journal
    • /
    • v.14 no.2
    • /
    • pp.149-156
    • /
    • 2004
  • This work focused on the degradation of natural organic matter (NOM) present in lake water using a combined pkotocatalysisimicrofiltration (MF) process. The system performances were investigated in terms of organic removal efficiency and membrane permeability. The addition of iron oxide particles (IOP) into the photocatalytic membrane reactor improved initial NOM removal by sorption, but during photocatalysis the removal efficiency was reversed, probably due to the scattering of UV light by IOP. The modification of TiO$_2$ surfaces by IOP deposition was conducted to enhance the photocatalytic NOM removal efficiency. A minimal amount of Impregnation of IOP on TiO$_2$ surfaces was required to prevent the light scattering effect as well. The coating of MF membranes with IOP helped to improve the NOM removal efficiency while sorbing NOM by IOP. Regardless of tile operating conditions and particles addition examined, no significant fouling was occurring at a flux of 15 L/$m^2$-h during entire MF operation.

Low Pressure Hybrid Membrane Processes for Drinking Water Treatment (저압 막여과 혼성공정을 이용한 고도 정수처리)

  • Choo, Kwang-Ho;Chung, Ji-Hyun;Park, Hak-Soon
    • Membrane Journal
    • /
    • v.17 no.3
    • /
    • pp.161-173
    • /
    • 2007
  • Membrane filtration processes are increasingly popular for drinking water treatment that requires high quality of water. Low pressure membrane(LPM) processes such as microfiltration(MF) and ultrafiltration(UF), however, are ineffective in the removal of dissolved organic matter and also membrane fouling is still an important issue to be resolved. High pressure membranes(HPMs) may guarantee better water quality, but at the high energy consumption. Thus, various approaches to combine LPM processes with other physicochemical methods have been recently made to achieve their efficiency to the level comparable to that of HPM processes. In this work, therefore, hybrid processes that coupled MF/UF with coagulation, adsorption, chemical reactions(e.g., chelation and oxidation) are reviewed regarding system design and performance and also membrane surface modifications conducted by grafting and polyelectrolyte multilayer formation were assessed.

The Effect of Support Material of Ceramic MF Membrane on the Fouling and backwashing Efficiency (세라믹 정밀여과막의 지지체 재질이 막오염과 역세척 효율에 미치는 영향)

  • 김재홍;이호상;이정학
    • Proceedings of the Membrane Society of Korea Conference
    • /
    • 1997.04b
    • /
    • pp.39-39
    • /
    • 1997
  • 김치산업에서 원재료의 염적공정중에 발생하는 폐염적수를 처리하여 염적공정에 재사용하는 새로운 시스템을 개발하였다. 관형 정밀여과막을 사용한 본 연구에서 막오염의 감소와 높은 막투과유속의 유지를 위하여 산역세척과 투과수역세척이 도입되었고 대상이 되었던 세공크기가 비슷한 4종류의 막(Carbosep M14, Membralox Z100, Membralox A200, Microdyne MD020TP 2N)에 대하여 역세척의 효율이 각각 다르게 나타났다. 특히 지르코니아 재질의 막 표면과 탄소재질의 지지체로 이루어진 Carbosep M14 세라믹막은 투과수역세척시에 역세척을 하지 않았을 때 보다 오히려 투과유속이 감소하는 특이한 현상이 관찰되었고 이러한 역세척 효율의 차이의 원인을 규명하기위한 연구가 진행되었다. 4종류의 막에 대하여 전처리된 폐염적수의 여과시 진행되는 막오염 메카니즘을 알아보기 위하여 문헌에서 잘 알려진 4가지의 여과모델식을 적용하여 보았고 직렬여과저항모델을 이용하여 여과저항을 세분하여 측정하였다. 모델식의 적용결과 역세척의 효율이 좋은 3종류의 막에는 막표면의 케이크형성이 주된 투과유속의 감소원인임을 알아내었고 carbosep M14 막은 용존유기물의 비가역적인 흡착과 세공막힘이 주된 원인임을 알 수 있었다.

  • PDF

Improvement of Fouling in Membrane Separation Process for Leachate Treatment using Ultrasound(II) : Analysis of Membrane Materials, Solutes and Multi-ultrasonic Effect (초음파를 이용한 침출수 처리를 위한 막분리 공정의 막힘현상 개선(II) : 막의 재질, 용질과 복합초음파의 효과 분석)

  • Kim, Seok-Wan;Lim, Jae-Lim;Lee, Jun-Geol
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.28 no.2
    • /
    • pp.207-215
    • /
    • 2006
  • This study evaluated the effect of ultrasonic irradiation on reducing membrane fouling for the treatment of chemically treated leachate and biologically treated leachate. The experiments on improvement of membrane flux according to the membrane types(MF and UF) and membrane materials were performed with changing frequency(40 kHz and 120 kHz) and intensity(200 W and 400 W) of ultrasound in ultrasonic membrane separation apparatus which ultrasound can be periodically irradiated. Additionally, the effect of dual frequency ultrasound which 40 kHz md 120 kHz are irradiated simultaneously was evaluated. The improvement of membrane flux by periodical ultrasound irradiation was higher in microfiltration(MF) membrane than in ultrafiltration(UF) membrane. It was sustained more in the MF membrane of polyvinylidene fluoride(PVDF) than in that of polysulfon(PS). Ultrasonic improvement of membrane flux was different depending on the characteristics of target wastewater. It was sustainably maintained without reclogging using dual frequency ultrasound although the improvement of membrane flux was lower.

Hybrid Water Treatment of Tubular Ceramic MF and Photocatalyst Loaded Polyethersulfone Beads: Effect of Organic Matters, Adsorption and Photo-oxidation at Water Back-flushing (관형 세라믹 정밀여과와 광촉매 첨가 PES 구의 혼성 수처리: 물 역세척 시 유기물 및 흡착, 광산화의 영향)

  • Park, Sung Woo;Park, Jin Yong
    • Membrane Journal
    • /
    • v.23 no.2
    • /
    • pp.159-169
    • /
    • 2013
  • The effect of humic acid (HA), and the roles of microfiltration (MF), PES (polyethersulfone) beads adsorption, and photo-oxidation were investigated in hybrid process of ceramic MF and PES beads loaded with titanium dioxide ($TiO_2$) photocatalyst for advanced drinking water treatment. The results of water and nitrogen back-flushing were compared in viewpoints of membrane fouling resistance ($R_f$), permeate flux (J), and total permeate volume ($V_T$). Because membrane fouling increased dramatically as increasing HA, Rf increased and J decreased, and finally $V_T$ was the highest at 2 mg/L HA. Average turbidity treatment efficiencies were almost same independent of HA concentration. Average organic matter treatment efficiency was the minimum 71.4% at 10 mg/L HA in water back-flushing, but those were almost constant in nitrogen back-flushing. The hybrid process of MF, PES beads, and UV (MF + $TiO_2$ + UV) have the lowest $R_f$, and the highest J and $V_T$ in both water and nitrogen back-flushing. The turbidity and organic matter treatment efficiencies were the maximum at MF + $TiO_2$ + UV independent of water and nitrogen back-flushing, and decreased sequently as simplifying the process to MF. However, adsorption performed the more important role than photo-oxidation in water back-flushing, and photo- oxidation was the more than adsorption in nitrogen back-flushing.

Comparition of Submerged / Pressurized Type Membrane System by DRF and Long-Term Results in MF Drinking Water Treatment (MF막여과 정수처리에서 장기운전 결과 및 DRF를 이용한 침지식 / 가압식 시스템의 비교 평가)

  • Ha, Keum Ryul;Kim, Kwan Yeop;Kim, Hyo-Sang;Lee, Yong Soo;Song, June Sup;Kim, Chung Hwan;Yeom, Ick Tae;Lee, Yong Hoon;Kim, Hyung Soo
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.22 no.1
    • /
    • pp.79-86
    • /
    • 2008
  • In Korea, most of the drinking water treatment relied upon the availability of the surface water, of which the raw water quality varied significantly by season and location. Therefore, the comparison of two operation modes (Pressurized type and Submerged type membrane system) must be estimated before the long-term establishment of two systems. In this study, two pilot-scale microfiltration systems with the capacity of $50m^3/day$ were installed and operated in two different modes, and the applicability of the system was determined based on the results such as the TMP (Trans-Membrane Pressure) and flux. For quantitatively comparing the two systems, a new concept, DRF (Differential Resistance Fraction) was introduced. The accumulated sum of the permeate after each cycle of chemical cleaning was also used as a tool for the system comparison.