• Title/Summary/Keyword: MEP

Search Result 198, Processing Time 0.022 seconds

Designing High Performance MEP Systems for Supertall Buildings: A Review of Challenges and Opportunities

  • Burton, Craig
    • International Journal of High-Rise Buildings
    • /
    • v.6 no.4
    • /
    • pp.301-306
    • /
    • 2017
  • The design and construction of supertall buildings has grown dramatically in recent years. This area of practice has traditionally fallen within the purview of a very small group of architects and engineers, but this is rapidly changing, as unprecedented growth and densification has spread to markets not traditionally known for high rise construction. The design community has been increasingly committed to the adoption of green and sustainable design, and the integration of smarter, cleaner technologies across the building spectrum. This paper examines current supertall design trends, and suggests that recently completed and planned projects are trending towards more sustainable solutions, and that a unique set of best practices are emerging specific to Supertalls.

Internet Roundtrip Delay Prediction Using the Maximum Entropy Principle

  • Liu, Peter Xiaoping;Meng, Max Q-H;Gu, Jason
    • Journal of Communications and Networks
    • /
    • v.5 no.1
    • /
    • pp.65-72
    • /
    • 2003
  • Internet roundtrip delay/time (RTT) prediction plays an important role in detecting packet losses in reliable transport protocols for traditional web applications and determining proper transmission rates in many rate-based TCP-friendly protocols for Internet-based real-time applications. The widely adopted autoregressive and moving average (ARMA) model with fixed-parameters is shown to be insufficient for all scenarios due to its intrinsic limitation that it filters out all high-frequency components of RTT dynamics. In this paper, we introduce a novel parameter-varying RTT model for Internet roundtrip time prediction based on the information theory and the maximum entropy principle (MEP). Since the coefficients of the proposed RTT model are updated dynamically, the model is adaptive and it tracks RTT dynamics rapidly. The results of our experiments show that the MEP algorithm works better than the ARMA method in both RTT prediction and RTO estimation.

A Multi-Expression Programming Application to the Design of Planar Antennae

  • Braunstein, Jeffrey;Kim, Hyeong-Seok;Kahng, Sung-Tek
    • Proceedings of the KIEE Conference
    • /
    • 2006.07c
    • /
    • pp.1589-1590
    • /
    • 2006
  • A method to determine functional relationships between the variable physical dimensions of an antenna and the antenna performance characteristics is presented. By applying multi-expression programming (MEP) to this data set, optimization with regard to a given criteria can be subsequently performed on the functions instead of performing repealed electromagnetic simulations. The functionals are trained on an initial population of simulation samples and refined using a point-wise error estimate to identify design parameters for subsequent samples. Additionally, the depth of the MEP tree is adjusted for increased accuracy as the data set is deemed sufficient.

  • PDF

Examining Change Order Reasons for Non-Structural Utility Support Projects in Healthcare Facilities

  • Genota, Naomi P.;Kim, Joseph J.
    • International conference on construction engineering and project management
    • /
    • 2022.06a
    • /
    • pp.188-195
    • /
    • 2022
  • Although issuing change orders is a common practice in the construction phase of any project, non-structural utility subcontractors are struggling and seek to find a way to reduce change orders. Therefore, this paper presents the analysis results on change orders to cultivate possible suggestions and solutions on how to reduce or minimize change orders in mechanical, electrical, and plumbing (MEP) works. Change orders in non-structural utility works are analyzed based on six categories such as rerouting and change of location, changes in weight, rejected design by Office of Statewide Health Planning and Development, District Structural Engineer, or the Structural Engineer of Record, unforeseen conditions, changed equipment, and owner-initiated change. The analysis findings showed that rerouting and changing location is the most significant cause, followed by unforeseen conditions. The results not only contribute to the existing body of knowledge on change order research area, but also help MEP contractors reduce the time and cost of change orders.

  • PDF

가속화되는 MEP 시대의 솔류션

  • 한국광학기기협회
    • The Optical Journal
    • /
    • v.14 no.2 s.78
    • /
    • pp.44-45
    • /
    • 2002
  • MFP시대는 복사기나 프린터, 팩시밀리를 포함한 업계의 자연 도태의 돌풍이 불고 있다는 것을 시사해 주고 있다. SAL시대와 같이 가격인하, 성능뿐만 아니라 소프트나 시스템 구축을 포함한 솔루션 판매가 가능한지의 여부에 모든 것이 걸려있다.

  • PDF

Pulmonary Functionn and the Maximal Inspiratory and Expiratory Pressure, and Maximum Phonation Time Before and After the Specially Programmed Training (호흡훈련보조기구를 이용한 호흡훈련 전 후의 폐기능 호흡근력과 최대발성지속시간의 변화)

  • 남도현;최홍식;안철민
    • Journal of the Korean Society of Laryngology, Phoniatrics and Logopedics
    • /
    • v.14 no.2
    • /
    • pp.88-93
    • /
    • 2003
  • Whether respiratory muscle training is of benefit to the singing students is controversial. The purpose of the study is to investigate pulmonary function and the maximal inspiratory(MIP) and expiratory pressure(MET), and maximum phonation time in five female singing students before and after the specially programmed respiratory muscle training during 2 months. All singing students had average 4.8 years of formal classical voice training. Respiratory muscle training machine (Ultrabreath) was used to train respiratory muscle. Pulmonary function test data on simple pulmonary function, flow volume curve, static lung volumes are obtained from Vmax 6200. The MIP and MEP were measured using Spirovis, and the MPT were measured using hand-held stopwatch. Any pulmonary function test variables are not changed after respiratory muscle training. However, MIP and MEP were significantly increased between before and after respiratory muscle training. MPT increased significantly after training, compared to the pre-trained. MIP, MEP, and MPT after training in female singing students were 26%, 25% and 33% higher than those before training. The result indicated that the specially programmed respiratory muscle training is beneficial to improve respiratory muscle strength and vocal function without an increment in pulmonary function.

  • PDF

Correlation Between Muscle Strength, Pulmonary Function and Respiratory Muscle in Children with Cerebral Palsy (뇌성마비 아동의 근력과 호흡기능의 상관관계)

  • Shin, Seung-Oh;Kim, Nan-Su
    • Journal of the Korean Society of Physical Medicine
    • /
    • v.11 no.2
    • /
    • pp.123-130
    • /
    • 2016
  • PURPOSE: This study was conducted to determine correlations between grip and lower limb muscle strength and pulmonary function and respiratory muscle in children with cerebral palsy. METHODS: Subjects were 17 children with cerebral palsy. Inclusion criteria for participation were having GMFCS from I to III grade and ability to independently blow into a spirometer. Pulmonary function and respiratory muscle were measured with a spirometer. All subjects performed maximal expiratory flow maneuvers using a spirometer in order to determine their forced expiratory volume in 1 second (FEV1), forced vital capacity (FVC), peak expiratory flow (PEF) and FEV1/FVC, and maximum inspiratory pressure (MIP) and maximum expiratory pressure (MEP). Muscle strength was measured in terms of grip strength and lower limb muscle strength in terms of knee extension strength with a dynamometer and manual digital muscle tester respectively. Data were analyzed using Person product correlation. RESULTS: Grip strength significantly positively correlated with FVC (r=0.95, p<0.01), FEV1 (r=0.95, p<0.01), PEF (r=0.84, p<0.01), MIP (r=0.65, p<0.01) MEP (r=0.71, p<0.01) and lower limb strength with FVC (r=0.72, p<0.01), FEV1 (r=0.69, p<0.01), PEF (r=0.54, p<0.05), and MEP (r=0.69, p<0.01). CONCLUSION: Grip and lower limb muscle strengths of children with cerebral palsy were positively correlated pulmonary function and respiratory muscle.

Large Point Cloud-based Pipe Shape Reverse Engineering Automation Method (대용량 포인트 클라우드 기반 파이프 형상 역설계 자동화 방법 연구)

  • Kang, Tae-Wook;Kim, Ji-Eum
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.3
    • /
    • pp.692-698
    • /
    • 2016
  • Recently, the facility extension construction and maintenance market portion has increased instead of decreased the newly facility construction. In this context, it is important to examine the reverse engineering of MEP (Mechanical Electrical and Plumbing) facilities, which have the high operation and management cost in the architecture domains. The purpose of this study was to suggest the Large Point Cloud-based Pipe Shape Reverse Engineering Method. To conduct the study, the related researches were surveyed and the reverse engineering automation method of the pipe shapes considering large point cloud was proposed. Based on the method, the prototype was developed and the results were validated. The proposed method is suitable for large data processing considering the validation results because the rendering performance standard deviation related to the 3D point cloud massive data searching was 0.004 seconds.

Comparisons of Diaphragm Movement and Pulmonary Function Between Normal Children and Children With Cerebral Palsy (정상 아동과 뇌성마비 아동의 감소된 횡격막 움직임 및 호흡 기능의 비교)

  • Kang, Min-soo;Shim, Jae-hoon;Kang, Sun-young
    • Physical Therapy Korea
    • /
    • v.25 no.1
    • /
    • pp.12-21
    • /
    • 2018
  • Background: Research efforts to improve the pulmonary function of children with cerebral palsy (CP) need to focus on their decreased diaphragmatic ability compared to normal children. Real-time ultrasonography is appropriate for demonstrating diaphragmatic mechanisms. Objects: This study aimed to compare diaphragm movement, pulmonary function, and pulmonary strength between normal children and children with CP by using ultrasonography M-mode. The correlation between general characteristics, diaphragm movement, pulmonary function, and pulmonary strength was also studied. Methods: The subjects of this study were 25 normal and 25 CP children between five and 14 years of age. Diaphragm movement was measured using real-time ultrasonography during quiet and deep breathing. Pulmonary function (such as forced expiratory volume in one second; FEV1 and peak expiratory flow; PEF) and pulmonary strength (such as maximum inspiratory pressure; MIP and maximum expiratory pressure; MEP) were measured. A paired t-test and Spearman's Rho test, with a significance level of .05, were used for statistical analysis. Results: The between-group comparison revealed that normal children had significantly greater diaphragm movement, FEV1, PEF, MIP, and MEP (p<.05) than CP children. The results showed that general characteristics were significantly related to FEV1, PEF, MIP, and MEP (p<.05). Conclusion: In clinical settings, clinicians need to concern decreased diaphragm movement, pulmonary function, and pulmonary strength in CP group compared to normal children.

Antitumor Activity of Cell Suspension Culture of Green Tea Seed (Camellia sinensis L.)

  • Choi, Jae-Hoon;Yoon, Sang-Kun;Lee, Keyong-Ho;Seo, Min-Soo;Kim, Doo-Hwan;Hong, Seung-Beom;Kim, Ji-Yeon;Paik, Hyun-Dong;Kim, Chang-Han
    • Biotechnology and Bioprocess Engineering:BBE
    • /
    • v.11 no.5
    • /
    • pp.396-401
    • /
    • 2006
  • The objective of this study was to investigate the antitumor activity of suspension cultures of tea callus cells grown in the presence of different concentrations of the growth regulator 2,4-dichlorophenoxy acetic acid (2,4-D) with or without light irradiation. The methanol and ethanol extracts of precipitated cells (MEP, EEP) exhibited stronger inhibitory effects on the growth of tumor cell lines than the water extract of precipitated cells (WEP) or the supernatant Compared to culture under dark conditions, exposure to light irradiation led to significantly higher antitumor activity. The MEP from light irradiated cells at $250{\mu}g/mL$ with 2.0mg/L 2,4-D displayed more than 64% growth inhibition of HEP-2 cells, whereas normal cells showed less than 25% growth inhibition. The some fractions of MEP obtained from Diaion HP-20 column chromatography displayed the majority of inhibitory activity against the HEP-2 cell line. These results show that 2,4-D, and light stimulated the synthesis of antitumor compounds.