Vibration-Robust Attitude and Heading Reference System Using Windowed Measurement Error Covariance

  • Kim, Jong-Myeong;Mok, Sung-Hoon;Leeghim, Henzeh;Lee, Chang-Yull
    • International Journal of Aeronautical and Space Sciences
    • /
    • 제18권3호
    • /
    • pp.555-564
    • /
    • 2017
  • In this paper, a new technique for attitude and heading reference system (AHRS) using low-cost MEMS sensors of the gyroscope, accelerometer, and magnetometer is addressed particularly in vibration environments. The motion of MEMS sensors interact with the scale factor and cross-coupling errors to produce random errors by the harsh environment. A new adaptive attitude estimation algorithm based on the Kalman filter is developed to overcome these undesirable side effects by analyzing windowed measurement error covariance. The key idea is that performance degradation of accelerometers, for example, due to linear vibrations can be reduced by the proposed measurement error covariance analysis. The computed error covariance is utilized to the measurement covariance of Kalman filters adaptively. Finally, the proposed approach is verified by using numerical simulations and experiments in an acceleration phase and/or vibrating environments.

고속 자율 무인잠수정 적용을 위한 MEMS 기술기반 자세 측정 장치 개발 (Development of Attitude Heading Reference System based on MEMS for High Speed Autonomous Underwater Vehicle)

  • 황아롬;안남현;윤선일
    • 해양환경안전학회지
    • /
    • 제19권6호
    • /
    • pp.666-673
    • /
    • 2013
  • 본 연구는 빠른 운항 속도와 짧은 운용 시간을 요구하는 임무에 활용될 저가 소형 자율 무인잠수정에 고가 대형 관성 측정 장치를 대신하여 사용할 수 있는 저가 소형 자세 측정 장치 개발 및 성능 검증을 수행하였다. 저가 소형 자세 측정 장치 개발을 위해서 MEMS 기술을 적용한 gyro, accelerometer 및 magnetometer 채택하여 MEMS 기반 하드웨어를 제작하였으며, 좌표 변환 공식과 칼만 필터를 적용하여 자세 계산 알고리즘을 구현하였다. 또한 개발된 MEMS 기반 자세 측정 장치에 대한 기본 성능 검증을 위한 지자기센서 검증 시험, 정적 자세 시험, 차량 시험, 운동 모사 장치 시험을 수행하였으며, 각각 시험 결과를 제시하였다. 지자기센서 검증 시험 결과 외부 자기장 보정을 통하면 개발된 MEMS 기반 자세 측정 장치의 측정 결과가 외부 자기장에 강인함을 확인하였으며, 정적 자세 시험 및 차량 시험을 통하여 자세 변화가 크지 않는 환경에서 자세 측정 오차가 $0.5^{\circ}/hr$ 임을 확인하였다. 운동 모사 장치 시험을 통하여 5분 내외 자세 변화가 큰 운동 중에도 자세 측정 오차가 발산하지 않고 $1^{\circ}/hr$ 이내임을 확인하였다. 상기 시험 결과로부터 개발된 MEMS 기반 자세 측정 장치가 목표 성능인 $1^{\circ}/hr$이내 roll, pitch, yaw 오차를 보여주고 있음 확인하였으며, 이로부터 20분 내외 운용 시간 동안 정확한 자세 정보 제공 가능성을 확인할 수 있었다.

2측 MEMS 가솔도 센서를 이용한 2차원 디지털 경사계 (A two dimensional digital clinometer with dual axis micromachined accelerometers)

  • 송기무;이진우
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 제37회 하계학술대회 논문집 C
    • /
    • pp.1619-1620
    • /
    • 2006
  • This paper deals with a new two dimensional clinometer based on dual axis micromachined accelerometers. The clinometer is a small and low-cost product, which is mainly developed to help golfers read easily the tilt of a putting green. First, this paper proposes the principle of two dimensional clinometer and also a calibration method to improve accuracy with respect to the offset voltage and sensitivity of a accelerometer. Experimental results show that the proposed clinometer can provide useful information on the tilt of an inclined plane.

  • PDF

단일 센서를 사용한 다기능 구현에 관한 연구 (A Study on Multi-function Implementation using Single Sensor)

  • 최수열;이창희
    • 한국인터넷방송통신학회논문지
    • /
    • 제16권4호
    • /
    • pp.133-137
    • /
    • 2016
  • IoT정보중 영상과 음성 정보가 많은 부분을 차지한다. 더 정확한 상황 인식과 주 정보의 부재에서 사용할 수 있는 다양한 센서가 요구되고 있다. 다양한 센서 사용에 따른 자원 관리의 증가로 이어진다. 여러 센서의 정보 전달에서 소요되는 자원을 줄이는 방법으로서 센서정보를 가공하여 다른 센서를 대신할 수 있는 가능성을 찾아본다. 본 논문에서는 LIS302 DL MEMS 모션센서를 사용하여 탁구대로 낙하하는 탁구공, 셔틀콕, 테니스공의 데이터를 측정하였다. 3가지 대상체에서 측정한 데이터는 충격량에 비례하는 함을 확인하였다. 이 실험은 가속도 센서를 사용하여 충격량으로 변경될 수 있음을 확인하였다. 이 결과 단일 센서를 사용하여 다기능구현이 가능함을 보였다. 또한, 센서의 초기 개발단계에서 다기능센서 고려 상황을 인식하게 한다.

비파괴시험과 관입시험에 의한 노상토의 물리·역학적 특성 (Physical and Mechanical Characteristics of Subgrade Soil using Nondestructive and Penetration Tests)

  • 김규선;김동휘;프라타 단테;이우진
    • 대한토목학회논문집
    • /
    • 제31권1C호
    • /
    • pp.19-27
    • /
    • 2011
  • 본 연구에서는 도로 성토현장에서 파 기반의 비파괴시험법과 관입시험의 현장 다짐품질 측정에 대한 적용성을 평가하였다. 현장에서 다짐 노상토의 물리 역학적 특성을 평가하기 위해 흙강성 측정기(SSG), 시간영역 반사측정기(TDR), 소형 전기-기계 시스템(MEMS) 가속도계 등의 비파괴시험을 이용하여 다짐 전후 흙의 응답을 평가하였고, 동적 콘관입시험기(DCP)를 이용하여 다짐 후 전단특성을 평가하였다. 현장시험은 두 가지 흙의 종류에 대해 네 가지의 다짐장비 및 다짐에너지로 조성된 성토지반에서 수행되었다. 시험결과, 조사 매커니즘이 다른 시험법인 SSG, TDR, MEMS 가속도계 및 DCP로 측정된 흙의 파라메터들은 상호 연관성이 있는 것으로 분석되었으며, 다짐지반의 전체적인 품질 및 공학적인 응답을 고려하여 시험 방법들을 현장에 적용할 경우, 기존의 다짐도 평가 방법들을 대체 또는 보완하여 현장에서 신속한 다짐품질 평가를 수행할 수 있는 것으로 나타났다.

MEMS 센서기반의 구조물의 안전 모니터링 시스템 (Safety Monitoring System of Structures Using MEMS Sensor)

  • 임재돈;김정집;홍두의;정회경
    • 한국정보통신학회논문지
    • /
    • 제22권10호
    • /
    • pp.1307-1313
    • /
    • 2018
  • 최근 빈번히 발생하고 있는 지진, 구조물의 노후화에 따라 구조물 붕괴 및 기울어짐 사고 등이 자주 발생하고 있으며, 이런 구조물에 대한 재난을 방지하기 위하여 다양한 방법이 제시되고 있는 실정이다. 이에 본 논문에서는 IoT(Internet of Things) 기반의 구조물 이상 유무를 실시간으로 모니터링 하여 구조물의 붕괴, 기울어짐, 화재 등에 대한 이상 징후현상을 사전에 제공하는 시스템을 제시한다. MEMS(Micro Electro Mechanical Systems) 센서(Sensor)기반의 기울기 센서, 가속도 센서를 이용, 센서별 검출된 데이터를 서버로 실시간 전송, 데이터를 축적하며, 설정된 임계치를 상위할 경우 대응할 수 있는 서비스를 제공 한다. 구조물의 붕괴, 기울어짐, 화재 등의 현상에 대한 임계치 상위 이벤트 발생 시 경고를 함으로, 구조물의 붕괴 및 기울어짐 현상에 대한 대피, 보수가 가능하여, 구조물에서 발생할 수 있는 재난에 대응할 수 있을 것이라고 사료된다.

Terra-Scope - a MEMS-based vertical seismic array

  • Glaser, Steven D.;Chen, Min;Oberheim, Thomas E.
    • Smart Structures and Systems
    • /
    • 제2권2호
    • /
    • pp.115-126
    • /
    • 2006
  • The Terra-Scope system is an affordable 4-D down-hole seismic monitoring system based on independent, microprocessor-controlled sensor Pods. The Pods are nominally 50 mm in diameter, and about 120 mm long. They are expected to cost approximately $6000 each. An internal 16-bit, extremely low power MCU controls all aspects of instrumentation, eight programmable gain amplifiers, and local signal storage. Each Pod measures 3-D acceleration, tilt, azimuth, temperature, and other parametric variables such as pore water pressure and pH. Each Pod communicates over a standard digital bus (RS-485) through a completely web-based GUI interface, and has a power consumption of less than 400 mW. Three-dimensional acceleration is measured by pure digital force-balance MEMS-based accelerometers. These accelerometers have a dynamic range of more than 115 dB and a frequency response from DC to 1000 Hz with a noise floor of less than $30ng_{rms}/{\surd}Hz$. Accelerations above 0.2 g are measured by a second set of MEMS-based accelerometers, giving a full 160 dB dynamic range. This paper describes the system design and the cooperative shared-time scheduler implemented for this project. Restraints accounted for include multiple data streams, integration of multiple free agents, interaction with the asynchronous world, and hardened time stamping of accelerometer data. The prototype of the device is currently undergoing evaluation. The first array will be installed in the spring of 2006.

모션 캡쳐를 위한 AHRS의 성능 향상 (Performance Improvement of an AHRS for Motion Capture)

  • 김민경;김태연;유준
    • 제어로봇시스템학회논문지
    • /
    • 제21권12호
    • /
    • pp.1167-1172
    • /
    • 2015
  • This paper describes the implementation of wearable AHRS for an electromagnetic motion capture system that can trace and analyze human motion on the principal nine axes of inertial sensors. The module provides a three-dimensional (3D) attitude and heading angles combining MEMS gyroscopes, accelerometers, and magnetometers based on the extended Kalman filter, and transmits the motion data to the 3D simulation via Wi-Fi to realize the unrestrained movement in open spaces. In particular, the accelerometer in AHRS is supposed to measure only the acceleration of gravity, but when a sensor moves with an external linear acceleration, the estimated linear acceleration could compensate the accelerometer data in order to improve the precision of measuring gravity direction. In addition, when an AHRS is attached in an arbitrary position of the human body, the compensation of the axis of rotation could improve the accuracy of the motion capture system.

지그비를 기반으로 한 운동감시 기능을 가진 1채널 ECG장치 개발 (Zigbee based 1-ch ECG device with activity monitoring function)

  • 홍주현;김남진;차은종;이태수
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 학술대회 논문집 정보 및 제어부문
    • /
    • pp.41-43
    • /
    • 2005
  • PDA-based monitoring is used to acquire continuously the patient's vital signs, including electrocardiography, activity, heart rate and $SpO_2$. In this paper, A biomedical signal acquisition device was designed using 3-axial MEMS accelerometer and 1-ch ECG amplifier, to have the function of monitoring activity and electrocardiography. The proposed system is composed of transmitter and receiver. Through the Zigbee communication, subject's biosignals can be transmitted in real-time to receiver, and transmitted data confirmed using PDA. The packet size used in this device was set not to exceed a maximum payload size of 116 byte. One packet consists of two segments. The transmission speed was 21 packet per second, 420 ECG samples per second, and 42 acceleration samples per second. The proposed method can be used to develop Activities of Daily Living(ADL} monitoring devices for the elderly or movement impaired people and enables patients to be monitored without any constraints. Also, this method will reduce medical costs in the aged society.

  • PDF

Implementation of Vehicle Navigation System using GNSS, INS, Odometer and Barometer

  • Park, Jungi;Lee, DongSun;Park, Chansik
    • Journal of Positioning, Navigation, and Timing
    • /
    • 제4권3호
    • /
    • pp.141-150
    • /
    • 2015
  • In this study, a Global Navigation Satellite System (GNSS) / Inertial Navigation System (INS) / odometer / barometer integrated navigation system that uses a commercial navigation device including Micro Electro Mechanical Systems (MEMS) accelerometer and gyroscope in addition to GNSS, odometer information obtained from a vehicle, and a separate MEMS barometer sensor was implemented, and the performance was verified. In the case of GNSS and GNSS/INS integrated navigation system that are generally used in a navigation device, the performance would deteriorate in areas where GNSS signals are not available. Therefore, an integrated navigation system that calculates a better navigation solution in areas where GNSS signals are not available compared to general GNSS/INS by correcting the velocity error of GNSS/INS using an odometer and by correcting the cumulative altitude error of GNSS/INS using a barometer was suggested. To verify the performance of the navigation system, a commercial navigation device (Softman, Hyundai Mnsoft, http://www.hyundai-mnsoft.com) and a barometer sensor (ST Company) were installed at a vehicle, and an actual driving test was performed. To examine the performance of the algorithm, the navigation solutions of general GNSS/INS and the GNSS/INS/odometer/barometer integrated navigation system were compared in an area where GNSS signals are not available. As a result, a navigation solution that has a smaller position error than that of GNSS/INS could be obtained in the area where GNSS signals are not available.