• 제목/요약/키워드: ME-ARE

검색결과 1,879건 처리시간 0.023초

Aminolysis of Y- Substituted Phenyl Benzenesulfonates in MeCN: Effect of Medium on Reactivity and Reaction Mechanism

  • Kim, Chae-Won;Lee, Jae-In;Um, Ik-Hwan
    • Bulletin of the Korean Chemical Society
    • /
    • 제32권spc8호
    • /
    • pp.2955-2959
    • /
    • 2011
  • Second-order rate constants for nucleophilic substitution reactions of 2,4-dinitrophenyl benzenesulfonate 1a with a series of alicyclic secondary amines in MeCN have been measured spectrophotometrically and compared with those reported previously for the corresponding reactions performed in aqueous medium to investigate the effect of medium on reactivity and reaction mechanism. The amines employed in this study are found to be more reactive in the aprotic solvent than in $H_2O$. The reactions of 1a in MeCN result in a linear Br${\o}$nsted-type plot with ${\beta}_{nuc}$ = 0.58, which contrasts to the curved Br${\o}$nsted-type plot reported previously for the corresponding reactions performed in the aqueous medium (i.e., ${\beta}_2$ = 0.86 and ${\beta}_1$ = 0.38). Accordingly, it has been concluded that the reaction mechanism changes from a stepwise mechanism to a concerted pathway upon changing the medium from $H_2O$ to MeCN. Reactions of Y-substituted phenyl benzenesulfonates 1a-c with piperidine in MeCN result in a linear Br${\o}$nsted-type plot with ${\beta}_{lg}$ = -1.31, indicating that expulsion of the leaving group is significantly more advanced than bond formation in the transition state. The trigonal bipyramidal intermediate ($TBPy^{\pm}$) proposed previously for the reactions in $H_2O$ would be highly unstable in MeCN due to strong repulsion between the negative charge in $TBPy^{\pm}$ and the negative dipole end of MeCN. Thus, destabilization of $TBPy^{\pm}$ in MeCN has been concluded to change the reaction mechanism from a stepwise mechanism to a concerted pathway.

The genial tubercle: A prospective novel landmark for the diagnosis of mandibular asymmetry

  • Lee, Seung-Youp;Choi, Dong-Soon;Jang, Insan;Song, Geun-Su;Cha, Bong-Kuen
    • 대한치과교정학회지
    • /
    • 제47권1호
    • /
    • pp.50-58
    • /
    • 2017
  • Introduction: Identifying menton (Me) on posteroanterior cephalograms and three-dimensional (3D) cone-beam computed tomography (CBCT) images is difficult, because the midpoint of the symphyseal area is not identifiable after the mandibular symphysis fuses at an early age. The aim of this study was to evaluate the reliability of the identification of the genial tubercle (GT) in patients with mandibular asymmetry and to compare it with that of the traditional landmark, Me. Methods: The samples comprised 20 CBCT images of adults with mandibular asymmetry. Two examiners performed the identifications and measurements. Me and GT were marked, and the anteroposterior, vertical, and transverse distances to the three reference planes were measured on 3D-reconstructed CBCT images. The intra- and inter-examiner reliability of landmark identification of Me and GT were assessed using the intraclass correlation coefficient (ICC) and Bland-Altman plots. Results: The Me and GT landmarks showed excellent reliability ($ICC{\geq}0.993$) three-dimensionally. In the transverse evaluation, the ICC values of the GT (range, 0.997-0.999) tended to be slightly higher than those of Me (range, 0.993-0.996). In the Bland-Altman plots for the two separate assessments, Me showed a maximum error of 1.76 mm in the transverse direction, whereas the GT showed a maximum error of 0.96 mm in the 95% limit. Conclusions: Our results suggest that both Me and GT are clinically reliable and equally useful landmarks for the evaluation of mandibular asymmetry on CBCT images.

Enhancement of a Liver Form of Cytosolic Phospholipase $A_2$ Activity by Methylmercury

  • Huh, Don-Haeng;Kang, Mi-Sun;Sohn, Dong-Hun;Na, Doe-Sun;Kim, Dae-Kyong
    • BMB Reports
    • /
    • 제31권2호
    • /
    • pp.189-195
    • /
    • 1998
  • Methylmercury (MeHg), which is widely distributed in the environment, is well known for both its acute and chronic poisoning effects on the human health; however, the precise biochemical mechanisms by which this compound elicits its toxicity in a cellular level are still poorly understood. To examine whether MeHg-induced liver injury involves activation of Phospholipase $A_2$ ($PLA_2$), the $PLA_2$ activity of control and MeHg-administrated livers was measured. MeHg stably enhanced a liver form of cytosolic $PLA_2$ activity, which exhibited several biochemical properties similar to those of the 100 kDa $cPLA_2$, except in its elution profile of a DEAE-5PW HPLC, and it migrated as a molecular weight of 80 kDa in Western blot analysis. This blotting analysis also indicated that the MeHg-induced enhancement of the activity could be due to the increase in the amount of the enzyme protein rather than a stable modification of the enzyme such as phosphorylation. Our data also showed the higher myeloperoxidase activity in MeHg-administrated liver than in the control, suggesting that this increase in the amounts of the 80 kDa $PLA_2$ and its activity may be resulted from infiltration of neutrophils into the liver during a hepatic injury process such as MeHg-induced inflammation. Taken together, these data suggest that MeHg-induced liver injury may be mediated by activation of the 80 kDa form of liver cytosolic $PLA_2$.

  • PDF

Monte Carlo Simulation of Phytosanitary Irradiation Treatment for Mangosteen Using MRI-based Geometry

  • Oh, Se-Yeol;Kim, Jongsoon;Kwon, Soon-Hong;Chung, Sung-Won;Kwon, Soon-Goo;Park, Jong-Min;Choi, Won-Sik
    • Journal of Biosystems Engineering
    • /
    • 제39권3호
    • /
    • pp.205-214
    • /
    • 2014
  • Purpose: Phytosanitary irradiation treatment can effectively control regulated pests while maintaining produce quality. The objective of this study was to establish the best irradiation treatment for mangosteen, a popular tropical fruit, using a Monte Carlo simulation. Methods: Magnetic resonance image (MRI) data were used to generate a 3-D geometry to simulate dose distributions in a mangosteen using a radiation transport code (MCNP5). Microsoft Excel with visual basic application (VBA) was used to divide the image data into seed, flesh, and rind. Radiation energies used for the simulation were 10 MeV (high-energy) and 1.35 MeV (low-energy) for the electron beam, 5 MeV for X-rays, and 1.25 MeV for gamma rays from Co-60. Results: At 5 MeV X-rays and 1.25 MeV gamma rays, all areas (seeds, flesh, and rind) were irradiated ranging from 0.3 ~ 0.7 kGy. The average doses decreased as the number of fruit increased. For a 10 MeV electron beam, the dose distribution was biased: the dose for the rind where the electrons entered was $0.45{\pm}0.03$ kGy and the other side was $0.24 {\pm}0.10$ kGy. Use of an electron kinetic energy absorber improved the dose distribution in mangosteens. For the 1.35 MeV electron beam, the dose was shown only in the rind on the irradiated side; no significant dose was found in the flesh or seeds. One rotation of the fruit while in front of the beam improved the dose distribution around the entire rind. Conclusion: These results are invaluable for determining the ideal irradiation conditions for phytosanitary irradiation treatment of tropical fruit.

Rosen형 압전 변압기 구조를 적용한 자기-전기 복합체의 특성 (Characteristics of Magnetoelectric Composite with Rosen Type Piezoelectric Transducer Structure)

  • 박성훈;윤운하;;류정호
    • 한국전기전자재료학회논문지
    • /
    • 제34권6호
    • /
    • pp.480-486
    • /
    • 2021
  • Magnetoelectric (ME) composite is composed of a piezoelectric material and a magnetostrictive material. Among various ME structures, 2-2 type layered ME composites are anticipated to be used as high-sensitivity magnetic field sensors and energy harvesting devices especially operating at its resonance modes. Rosen type piezoelectric transducer using piezoelectric material is known to amplify a small electrical input voltage to a large electrical output voltage. The output voltage of these Rosen type piezoelectric transducers can be further enhanced by modifying them into ME composite structures. Herein, we fabricated Rosen type ME composites by sandwiching Rosen type PMN-PZT single crystal between two Ni layers and studied their ME coupling. However, the voltage step-up ratio at the resonance frequency was found to be smaller than the value calculated with αME value. The ATILA FEA (Finite Elements Analysis) simulation results showed that the position of the nodal point was changed with the presence of a magnetostrictive layer. Thus, while designing a Rosen type ME composite with high performance in a resonant driving situation, it is necessary to optimize the position of the nodal point by optimizing the thickness or length of the magnetostrictive layer.

ChIP-seq Analysis of Histone H3K27ac and H3K27me3 Showing Different Distribution Patterns in Chromatin

  • Kang, Jin;Kim, AeRi
    • 대한의생명과학회지
    • /
    • 제28권2호
    • /
    • pp.109-119
    • /
    • 2022
  • Histone proteins can be modified by the addition of acetyl group or methyl group to specific amino acids. The modifications have different distribution patterns in chromatin. Recently, histone modifications are studied based on ChIP-seq data, which requires reasonable analysis of sequencing data depending on their distribution patterns. Here we have analyzed histone H3K27ac and H3K27me3 ChIP-seq data and it showed that the H3K27ac is enriched at narrow regions while H3K27me3 distributes broadly. To properly analyze the ChIP-seq data, we called peaks for H3K27ac and H3K27me3 using MACS2 (narrow option and broad option) and SICER methods, and compared propriety of the peaks using signal-to-background ratio. As results, H3K27ac-enriched regions were well identified by both methods while H3K27me3 peaks were properly identified by SICER, which indicates that peak calling method is more critical for histone modifications distributed broadly. When ChIP-seq data were compared in different sequencing depth (15, 30, 60, 120 M), high sequencing depth caused high false-positive rate in H3K27ac peak calling, but it reflected more properly the broad distribution pattern of H3K27me3. These results suggest that sequencing depth affects peak calling from ChIP-seq data and high sequencing depth is required for H3K27me3. Taken together, peak calling tool and sequencing depth should be chosen depending on the distribution pattern of histone modification in ChIP-seq analysis.

병풀(Centella asiatica)로부터의 asiaticoside와 madecassoside의 추출효율에 미치는 DES의 영향 (Effect of deep eutectic solvent (DES) on the extraction of asiaticoside and madecassoside from Centella asiatica)

  • 최재영;전유임;하성호
    • 분석과학
    • /
    • 제36권3호
    • /
    • pp.128-134
    • /
    • 2023
  • 병풀(Centella asiatica) 추출물인 asiaticoside와 madecassoside는 항균성 및 피부재생 등의 효과로 인해 아시아 지역에서 치료용 연고에 사용되고 있으며, 병풀의 재배 및 추출효율을 높이기 위한 연구가 상업화를 위해 활발히 진행되고 있다. 본 연구에서는 환경 친화적인 추출 용매인 deep eutectic solvents(DESs)가 병풀에서 asiaticoside와 madecassoside의 추출 효율에 미치는 영향을 관찰하기 위하여 다양한 수소결합 받개(hydrogen bond acceptor, HBA)와 주개(hydrogen bond donor, HBD)의 혼합 몰비(HBA1: HBD2, HBA1:HBD3, HBA1:HBD4, 그리고 HBA1:HBD5)로 제조하여 추출용매로 사용하였며, 용매 추출에서 일반적으로 사용되고 있는 추출용매인 증류수(DW)와 methanol (MeOH)의 추출 결과를 최적화된 HPLC조건으로 분리하여 정량 분석하였다. 그 결과, DW와 DES를 3:7로 혼합하여 사용한 경우가 단일 MeOH를 사용한 경우보다 약 1.4배 높은 추출 효율을 보였다. 반대로 MeOH과 DES를 3:7로 혼합하여 사용하는 경우에서는 단일 MeOH를 사용하는 경우보다 약 6 % 낮은 추출 효율을 보였다.

Energy Spectrum Measurement of High Power and High Energy (6 and 9 MeV) Pulsed X-ray Source for Industrial Use

  • Takagi, Hiroyuki;Murata, Isao
    • Journal of Radiation Protection and Research
    • /
    • 제41권2호
    • /
    • pp.93-99
    • /
    • 2016
  • Background: Industrial X-ray CT system is normally applied to non-destructive testing (NDT) for industrial product made from metal. Furthermore there are some special CT systems, which have an ability to inspect nuclear fuel assemblies or rocket motors, using high power and high energy (more than 6 MeV) pulsed X-ray source. In these case, pulsed X-ray are produced by the electron linear accelerator, and a huge number of photons with a wide energy spectrum are produced within a very short period. Consequently, it is difficult to measure the X-ray energy spectrum for such accelerator-based X-ray sources using simple spectrometry. Due to this difficulty, unexpected images and artifacts which lead to incorrect density information and dimensions of specimens cannot be avoided in CT images. For getting highly precise CT images, it is important to know the precise energy spectrum of emitted X-rays. Materials and Methods: In order to realize it we investigated a new approach utilizing the Bayesian estimation method combined with an attenuation curve measurement using step shaped attenuation material. This method was validated by precise measurement of energy spectrum from a 1 MeV electron accelerator. In this study, to extend the applicable X-ray energy range we tried to measure energy spectra of X-ray sources from 6 and 9 MeV linear accelerators by using the recently developed method. Results and Discussion: In this study, an attenuation curves are measured by using a step-shaped attenuation materials of aluminum and steel individually, and the each X-ray spectrum is reconstructed from the measured attenuation curve by the spectrum type Bayesian estimation method. Conclusion: The obtained result shows good agreement with simulated spectra, and the presently developed technique is adaptable for high energy X-ray source more than 6 MeV.

Applications of Third Order Models in Solvolytic Reaction of Aliphatic Substituted Acyl Derivatives in 2,2,2-Trifluoroethanol-Ethanol Systems

  • Ryu, Zoon-Ha;Lim, Gui-Taek;Bentley, T. William
    • Bulletin of the Korean Chemical Society
    • /
    • 제24권9호
    • /
    • pp.1293-1302
    • /
    • 2003
  • Rate constants at various temperatures and activation parameters are reported for solvolyses of acyl chlorides (RCOCl), with R = Me, Et, i-Pr, t-Bu, cyclopentylmethyl, benzyl, thiophenylmethyl, 2-phenylethyl, diphenylmethyl, and phenylthiomethyl in 100% ethanol, 100% 2,2,2-trifluoroethanol (TFE), 80% v/v ethanol/ water and 97% w/w TFE/water. Additional rate constants for solvolyses with R = Me, t-Bu, and $PhCH_2$ are reported for TFE/water and TFE/ethanol mixtures, and for solvolyses with R = t-Bu, and PhCH2 are reported for 1,1,1,3,3,3-hexafluoropropan-2-ol/water mixtures, as well as selected kinetic solvent isotope effects (MeOH/MeOD and TFE). Taft plots show that electron withdrawing groups (EWG) decrease reactivity significantly in TFE, but increase reactivity slightly in ethanol. Correlation of solvent effects using the extended Grunwald-Winstein (GW) equation shows an increasing sensitivity to solvent nucleophilicity for EWG. The effect of solvent stoichiometry in assumed third order reactions is evaluated for TFE/ethanol mixtures, which do not fit well in GW plots for R = Me, and t-Bu, and it is proposed that one molecule of TFE may have a specific role as electrophile; in contrast, reactions of substrates containing an EWG can be explained by third order reactions in which one molecule of solvent (ethanol or TFE) acts as a nucleophile, and a molecule of ethanol acts as a general base catalyst. Isokinetic relationships are also investigated.

전자선 Quality Assurance 선량계 개발을 위한 TlBr 물질의 검출성능 평가 (Evaluation of Detection Performance of TlBr Materials for the Development of Electron Beam Quality Assurance Dosimeters)

  • 양승우;박성광
    • 한국방사선학회논문지
    • /
    • 제16권5호
    • /
    • pp.513-518
    • /
    • 2022
  • 전자선의 정도관리(quality assurance, QA)는 정확한 방사선 치료를 위해 정기적으로 이루어져야한다. 하지만 임상에서 사용되는 QA도구는 X선 위주로 설계되어 있어서 전자선 전용의 QA 선량계가 요구된다. 이에 본 연구에서는 방사선 검출 효율이 뛰어난 브롬화탐륨 물질을 전자선 센서로 활용하여 전자선 검출성능을 측정하고 전자선 전용의 QA 선량계로 적용가능할지를 평가하였다. 평가항목은 재현성, 선형성, 선량률 의존성이며, 선형가속기의 6 MeV, 9 MeV 에너지에서 평가하였다. 재현성 결과, 6 MeV에서는 최대 0.92%, 9 MeV에서는 최대 1.15%의 출력변화를 보여주었다. 선형성 결과평가, 결정계수 R2이 0.9998로 제시되었다. 선량률 의존성 평가 결과, 6 MeV에서는 상대표준편차 0.51%, 9 MeV에서는 상대표준편차 1.07%의 선량률 의존성이 제시되었다. 본 연구에서 제작한 TlBr 센서는 재현성, 선형성, 선량률 의존성의 모든 평가기준을 만족하는 검출성능을 보여준다. 이러한 결과들은 TlBr 선량계가 전자선 전용 QA 선량계로 적용 가능한 것을 의미한다.