• 제목/요약/키워드: MDVP parameters

검색결과 36건 처리시간 0.03초

성대 폴립 환자를 대상으로 한 GRBAS 척도와 MDVP 측정치 간의 상관관계 연구 (The Correlation between GRBAS Scales and MDVP Parameters on the Pathologic Voices of the Patients with Vocal Polyps)

  • 표화영;최성희;임성은;심현섭;최홍식;김광문
    • 대한후두음성언어의학회지
    • /
    • 제10권2호
    • /
    • pp.154-163
    • /
    • 1999
  • GRBAS scale, the tool fir the perceptual evaluation of voice, demands the experience of judges, and MDVP parameters of CSL, the tool for the objective measurements of voice quality demands the exact interpretation of the analyzed results. The two tools should be used as compensatory evaluation methods, so the experimental study was performed to investigate the correlation between GRBAS scales and MDVP parameters by using the pathologic voice of the 30 patients with vocal polyps, and to know the significant MDVP parameters which the inexperienced GRBAS scale judges should attend to. The 30 subjects voices, saved in MDVP of CSL were analyzed by its own analysis program, and three experienced voice therapists judged the same voices by using GRBAS scales. The correlations between them were analyzed by Spearman Rank Correlation Coefficient. As results, among the 29 MDVP parameters, 22 parameters showed statistically significant correlation with Grade(G) scale(p<0.05). And it was found that Roughness(R) scale showed significant correlation with 18 parameters, Breathiness(B) scale with 17 parameters, Strain(S) scale with 12 parameters. In Asthenicity(A) scale, no parameter showed significant correlation. On the whole, significantly high correlation were found in the parameters related with pitch ind amplitude perturbation, especially, the amplitude perturbation.

  • PDF

성대결절 음성 중증도에 따른 MDVP와 Praat 프로그램 별 파라미터 차이 (Difference in Voice Parameters of MDVP and Praat Programs according to Severity of Voice Disorders in Vocal Nodule)

  • 심상용;김향희;김재옥;신지철
    • 말소리와 음성과학
    • /
    • 제6권2호
    • /
    • pp.107-114
    • /
    • 2014
  • MDVP and Praat are measured by nine variables in common; F0, jitter local, jitter absolute, jitter relative average perturbation, jitter period perturbation quotient, shimmer local, shimmer dB, shimmer amplitude perturbation quotient, and NHR. In the present study, 30 female subjects were divided by their disorders(control group, vocal nodule group), ages(from 18 to 50 years old), gender(women), and severities of voice disorder(GRBAS-G0, G1, G2). Then, the subjects' vowel /a/ was evaluated by MDVP and Praat. First, jitter and shimmer variables of the MDVP were significantly different by severities. Praat showed different jitter, shimmer, and NHR parameters by severities. Second, jitter and NHR levels of MDVP were meaningfully higher than Praat regardless their severities. The result of the research confirms the relationships among GRBAS, MDVP and Praat as well as the differences in acoustic variables between MDVP and Praat.

성별에 따른 한국 정상 성인 음성의 음향학적 평가 기준치 (Acoustic Characteristics of the Voices of Korean Normal Adults by Gender on MDVP)

  • 김재옥
    • 말소리와 음성과학
    • /
    • 제1권4호
    • /
    • pp.147-157
    • /
    • 2009
  • The purpose of the study is to develop the normal voice database and to analyze the acoustic characteristics of Korean adults' voices by gender using MDVP. Eight categories in the 34 parameters of MDVP were analyzed in the voices of 170 Korean normal adults taken from /a/ vowel. Among them, Fundamental Frequency Parameters and Frequency Perturbation Parameters were significantly different by gender. In addition, Fundamental Frequency Parameters of our data were remarkably different from the data suggested in the MDVP program which currently used in clinics. Therefore, the data obtained from the current study can be effectively used for the diagnosis of voice disorders of Korean adults as the standard parameter values of MDVP.

  • PDF

Development of Parameters for Diagnosing Laryngeal Diseases

  • Kim, Yong-Ju;Wang, Soo-Geun;Kim, Gi-Ryun;Kwon, Soon-Bok;Jeon, Kye-Rok;Back, Moo-Jin;Yang, Byung-Gon;Jo, Cheol-Woo;Kim, Hyung-Soon
    • 음성과학
    • /
    • 제10권1호
    • /
    • pp.117-129
    • /
    • 2003
  • Many people suffer from various laryngeal diseases. Since we can notice voice change easily, acoustic analysis can be helpful to diagnose the diseases. Several attempts have been made to clarify the relation between the parameters and the state of sick vocal folds but any decisive parameters are not found yet. The purpose of this study was to select and develop those parameters useful for diagnosing and differentiating laryngeal diseases. We examined eight MDVP parameters, and two additional MFCC and LPC parameters obtained from the production of an open vowel by 252 subjects with or without laryngeal diseases. Using a statistical procedure through the artificial neural networks, we attempted to differentiate laryngeal disease groups. Results showed that the LPC parameters indicated the highest differentiating rate by the networks followed by the MFCC and the MDVP parameters. In addition, Jita, Shim and NHR among the MDVP parameters came out better parameters in diagnosing laryngeal diseases.

  • PDF

음성 Sample의 길이 변화에 따른 MDVP 측정치와 GRBAS 척도간의 상관관계 변화 비교 (The Change of the Correlation between GRBAS Scales and MDVP Parameters according to the Different Length of Voice Samples for MDVP Analysis)

  • 표화영;심현섭;임성은
    • 음성과학
    • /
    • 제7권2호
    • /
    • pp.71-81
    • /
    • 2000
  • The present study was performed to find efficient and useful length of voice sample for MDVP analysis, by investigating the correlation between perceptual GRBAS scales and objective MDVP measurements, with the five different lengths of voices of 20 patients with vocal polyp: 0.5, 1.0, 1.5, 2.0, 2.5 seconds. The results are following: (1) 1.5-second sample of MDVP showed the highest correlation between the perceptual judgement and objective measurement, and 1.0-second sample showed the lowest. The difference between the two samples was found in the number of the statistically significant correlated pairs of MDVP parameter-GRBAS scale. (2) The two extreme edges of the lengths, 0.5-second and 2.5 second showed no statistically significant difference.

  • PDF

MDVP와 Praat, Dr. Speech간의 음향학적 측정치에 관한 상관연구 (A Correlation Study among Acoustic Parameters of MDVP, Praat, and Dr. Speech)

  • 유재연;정옥란;장태엽;고도흥
    • 음성과학
    • /
    • 제10권3호
    • /
    • pp.29-36
    • /
    • 2003
  • The purposes of this study was to conduct a correlational analysis among $F_^{0}$, Jitter, Shimmer, and NHR (HNR), and NNE estimated by three speech analysis softwares, MDVP, Praat and Dr. Speech. Thirty females and 15 males with normal voice participated in the study. We used Sound Forge 6.0 to record their voice. MDVP, Praat and Dr. Speech were used to measure the acoustic parameters. The Pearson correlation coefficient was determined through a statistical analysis. The results came out as follows: Firstly, there was a strong correlation between $F_^{0}$ and Shimmer of both instruments. However, there was no correlation between Jitter of both instruments. Secondly, Shimmer showed a stronger correlation with HNR, NHR, and NNE than Jitter. Therefore, Shimmer was considered to be more useful and sensitive parameter to identify dysphonic voice compared to jitter.

  • PDF

정상 한국인의 성별 체형정보와 MDVP 변수간의 상관관계 연구 (A Study on the Correlation between Body-Size and MDVP Parameters in the Normal Male and Female Korean Population)

  • 강재환;유종향;김종열
    • 음성과학
    • /
    • 제15권4호
    • /
    • pp.107-119
    • /
    • 2008
  • This paper intends to investigate the correlation of 12 MDVP measurements with age, sex and body-size of sampled healthy patients. In order to extract pitch and 12 MDVP parameters efficiently and display the correlation of each parameter easily, we developed the speech analysis program using C/C++ and MFC development tool. The sample group consists of 205 males and 343 females with ages 9-81. We collected vowel voices /a/ and 8 body-size measurements from them. Body-size values were taken at 8 different torso positions of each person. We analyzed the matched voice samples and body-size measurements by the developed speech analysis program and SPSS program. The result shows that a typical characteristic age-F0 pattern that F0 of male subjects are rapidly decreased after mutational period and have stable state with age and that of female subjects are slowly changed by overall age. In MDVP, age-STD in males, age-sPPQ in females relationships are especially similar to the age-F0 relationship. In case of male group, sPPQ(0.316%), Jitt(0.04%), Shim(0.25%), APQ(0.28%) variables are increased with age after mutational period. And Jitt(0.042%), sPPQ(0.219%) of females group are increased with age too. In cases of height, weight and BMI there exists a weak correlation with MDVP, which shows a correlation coefficient below 0.25 about male and female groups. The survey of correlation relationship between 8 body-size measurements and MDVP shows a insignificant statistical result by only just having the correlation coefficient maximum in M8-8 and F0(-0.394%) for males and M8-6,7(-0.368%, -0.364%) for females.

  • PDF

MDVP와 Dr. Speech의 음향학적 측정치에 관한 상관연구 (A Correlation Study among Acoustic Parameters of MDVP and Dr. Speech)

  • 유재연;안종복;정옥란;장태엽
    • 대한음성학회:학술대회논문집
    • /
    • 대한음성학회 2002년도 11월 학술대회지
    • /
    • pp.133-136
    • /
    • 2002
  • The purpose of this study was to determine the correlation between the Average Fundamental Frequency, Fo-Tremor Frequency, Jitter, Shimmer, Amplitude Tremor Intensity Index, and Noise to Harmonic Ratio of MDVP and Fo, Fo Tremor, Jitter, Shimmer, Amp Tremor, HNR, and NNE of Dr. Speech. The Pearson correlation coefficient was used for analysis. The results showed that there was a strong correlation between Fo and Shimmer of both instruments. However, the remaining parameters did not show a significant correlation.

  • PDF

성대 용종 환자의 후두미세수술 전후 음성 평가에서 OperaVOXTM와 Multi-Dimensional Voice Program 간의 신뢰도 연구 (Reliability of OperaVOXTM against Multi-Dimensional Voice Program to Assess Voice Quality before and after Laryngeal Microsurgery in Patient with Vocal Polyp)

  • 김선우;김소연;조재경;진성민;이상혁
    • 대한후두음성언어의학회지
    • /
    • 제31권2호
    • /
    • pp.71-77
    • /
    • 2020
  • Background and Objectives OperaVOXTM (Oxford Wave Research Ltd.) is a portable voice analysis software package designed for use with iOS devices. As a relatively cheap, portable and easily accessible form of acoustic analysis, OperaVOXTM may be more clinically useful than laboratory-based software in many situations. The aim of this study was to evaluate the agreement between OperaVOXTM and Multi-Dimensional Voice Program (MDVP; Computerized Speech Lab) to assess voice quality before and after laryngeal microsurgery in patient with vocal polyp. Materials and Method Twenty patients who had undergone laryngeal microsurgery for vocal polyp were enrolled in this study. Preoperative and postoperative voices were assessed by acoustic analysis using MDVP and OperaVOXTM. A five-seconds recording of vowel /a/ was used to measure fundamental frequency (F0), jitter, shimmer and noise-to-harmonic ratio (NHR). Results Several acoustic parameters of MDVP and OperaVOXTM related to short-term variability showed significant improvement. While pre-operative value of F0, jitter, shimmer, NHR was 155.75 Hz (male: 125.37 Hz, female: 183.37 Hz), 2.20%, 6.28%, 0.16, post-operative values of these parameter was 164.34 Hz (male: 129.42 Hz, female: 199.26 Hz), 2.15%, 5.18%, 0.14 Hz in MDVP. While pre-operative value of F0, jitter, shimmer, NHR was 168.26 Hz (male: 135.16 Hz, female: 201.37 Hz), 2.27%, 6.95%, 0.26, post-operative values of these parameters was 162.72 Hz (male: 128.267 Hz, female: 197.18 Hz), 1.71%, 5.36%, 0.20 in OperaVOXTM. There was high intersoftware agreement for F0, jitter, shimmer with intraclass correlation coefficient. Conclusion Our results showed that the short-term variability of acoustic parameters in both MDVP and OperaVOXTM were useful for the objective assessment of voice quality in patients who received laryngeal microsurgery. OperaVOXTM is comparable to MDVP and has high intersoftware reliability with MDVP in measuring the F0, jitter, and shimmer

MDVP, Praat, TF32에 따른 음향학적 측정치에 대한 비교 (Comparisons of voice quality parameter values measured with MDVP, Praat, and TF32)

  • 고혜주;우미령;최예린
    • 말소리와 음성과학
    • /
    • 제12권3호
    • /
    • pp.73-83
    • /
    • 2020
  • 음질 분석에 매우 유용한 Multi-Dimensional Voice Program (MDVP), Praat, Time-Frequency Analysis software (TF32)는 각각의 음향학적 검사에 사용된 알고리즘 차이로 인해 그 측정치에 차이가 있을 수 있다. 그러므로 본 연구에서는 각각의 음향학적 검사 도구로 음성 측정치를 비교 분석하여 분석 도구에 따른 음향학적 검사 변수의 차이를 살펴보고자 하였다. 정상 성인 총 35명 (남성 19명, 여성 16명)을 대상으로 모음 /아/를 수집한 후, 동일한 음성을 MDVP, Praat, TF32 각각의 음향학적 검사 도구로 분석하였다. 그 결과 jitter 변수(J local, J abs, J rap, J ppq), shimmer 변수(S local, S dB, S apq), noise-to-harmonics ratio (NHR) 평균의 경우, 남성과 여성 모두 MDVP보다 Praat의 수치가 통계적으로 유의하게 낮았다(p<.01). 또한 J local, J abs, S local 평균의 경우, 남성과 여성 모두 MDVP, Praat, TF32 순으로 통계적으로 유의하게 낮아졌다. 결론적으로 각 음향학적 검사 도구에 사용된 알고리즘 차이로 인해 도구 간의 측정치에 차이가 있었다. 그러므로 임상가들이 임상현장에서 각각의 음향학적 검사 도구를 사용할 때 각 도구의 알고리즘에 대해 이해한 후 병적 음성을 분석하는 것이 중요할 것이다.