• 제목/요약/키워드: MBR(Membrane Bio Reactor)

검색결과 37건 처리시간 0.024초

순산소 고율포기시스템 및 침지식 MBR융합공정에서 Biofouling 제어 및 원인물질 규명에 관한 연구 (The Study of Biofouling Control and Cause Material in Hybrid Process of Pure Oxygen and Submerged Membrane Bio-reactor)

  • 이상민;김미형
    • 한국물환경학회지
    • /
    • 제27권1호
    • /
    • pp.44-53
    • /
    • 2011
  • Membrane bio-reactor (MBR) has several advantages over the conventional activated sludge process, including a high biomass, low sludge production, and better permeate quality. Therefore, the MBR have gained popularity for municipal and industrial wastewater treatment. However the MBR usually were used for sewage and low streng th wastewater treatment because of membrane fouling problem and limitation of oxygen transfer into biomass. In this study, the hybrid process combining MBR and pure oxygen was tested for high strength organic wastewater treatment in the COD loading range from 2 to $10kgCOD/m^3{\cdot}day$. The hybrid process, membrane coupled pure oxygen high compact reactor (MPHCR), had been operated for one year and operation parameters, the effect of COD loading, MLSS concentration and the location of membrane module were studied for membrane fouling characteristic. Also membrane resistance test and the component of foulant was analyzed to investigate what is specific foulant in the MBR.

막결합형 생물반응기(Membrane Bio-Reactor)의 막 오염 저감을 위한 고전압 펄스의 적용과 막 오염 저감 속도론적 해석 (Application of high voltage pulse for reduction of membrane fouling in membrane bio-reactor and kinetic approach to fouling rate reduction)

  • 김경래;김완규;장인성
    • 상하수도학회지
    • /
    • 제34권3호
    • /
    • pp.183-190
    • /
    • 2020
  • Although membrane bio-reactor (MBR) has been widely applied for wastewater treatment plants, the membrane fouling problems are still considered as an obstacle to overcome. Thus, many studies and commercial developments on mitigating membrane fouling in MBR have been carried out. Recently, high voltage impulse (HVI) has gained attention for a possible alternative technique for desalting, non-thermal sterilization, bromate-free disinfection and mitigation of membrane fouling. In this study, it was verified if the HVI could be used for mitigation of membrane fouling, particularly the internal pore fouling in MBR. The HVI was applied to the fouled membrane under different conditions of electric fields (E) and contact time (t) of HVI in order to investigate how much of internal pore fouling was reduced. The internal pore fouling resistance (Rf) after HVI induction was reduced as both E and t increased. For example, Rf decreased by 19% when the applied E was 5 kV/cm and t was 80 min. However, the Rf decreased by 71% as the E increased to 15 kV/cm under the same contact time. The correlation between E and t that needed for 20% of Rf reduction was modeled based on kinetics. The model equation, E1.54t = 1.2 × 103 was obtained by the membrane filtration data that were obtained with and without HVI induction. The equation states the products of En and t is always constant, which means that the required contact time can be reduced in accordance with the increase of E.

전기응집 조건이 활성슬러지 막 여과 저항에 미치는 영향 (Effect of operating condition of electro-coagulation on the membrane filtration resistances of activated sludge)

  • 홍성준;장인성
    • 한국산학기술학회논문지
    • /
    • 제16권3호
    • /
    • pp.2314-2320
    • /
    • 2015
  • MBR (Membrane Bio-Reactor) 공정은 막 오염을 해결하기 위해 막대한 에너지 소비를 하는 공정으로 알려져 있다. 이를 해결하기 위한 일환으로 전기응집 기술을 MBR에 적용하는 시도가 보고되고 있다. 본 연구에서는 전류밀도를 변화시켜가며 활성슬러지의 막 여과를 수행하여 전기응집이 막 오염 저감에 미치는 영향과 메커니즘을 파악하고자 하였다. 활성슬러지 혼합액을 전기응집한 후 회분식교반셀로 분리 막의 여과성능을 평가하였다. 전류밀도(A/m2)를 10에서 40으로 증가시켰을 때 총 오염 저항 (Rc+Rf) 값이 18%에서 79%까지 감소하여 전기응집으로 인해 분리 막의 여과성능이 향상됨을 확인할 수 있었다. 전기응집 전후로 유기물 농도와 활성슬러지 입도분포 변화는 거의 일어나지 않았다. 여과 성능의 향상은 수산화알루미늄, Al(OH)3이 생성되어 막 표면에 부착되면서 오염물질이 쌓이게 됨을 방지하는 역할, 즉 dynamic membrane 으로 작용하였기 때문인 것으로 판단되었다.

동시 질산화-탈질(SND) 반응을 적용한 MBR 반응조에서 질소 및 인 제거 특성 (Nitrogen and Phosphorus Removal in Membrane Bio-Reactor (MBR) Using Simultaneous Nitrification and Denitrification (SND))

  • 전동걸;임현숙;안찬현;이봉규;전항배;박찬일
    • 대한환경공학회지
    • /
    • 제35권10호
    • /
    • pp.724-729
    • /
    • 2013
  • 동시 질산화 탈질은 미세 용존 산소하에 한 반응조내에서 일어난다. 따라서, 본 연구에서는 인 방출을 위해 공기가 공급되는 MBR 전단에 혐기성 존을 만들어주었으며, 높은 DO 농도에서 탈질효율을 향상시켜 주기 위해서는 MBR 내에 배플을 설치하여 무산소 존이 이루어지게 하였다. 그리고 인 제거를 위한 테스트는 MBR 전단의 혐기성 반응조에 알럼 응집제를 투입하여 수행하였다. 질소 제거를 위한 SND의 최적 DO 농도 도출은 MBR 내 DO 농도를 2.0, 1.5, 1.0, 0.75 mg/L의 다양한 조건에서의 운전을 통해 수행하였다. 심지어 높은 알칼리성 하수라 알럼 응집제를 투입하였을 때 알칼리 용액 첨가 없이도 pH는 7.0~8.0로 유지되었다. TCODcr와 $NH_4^+$-N의 제거 효율은 모든 DO 농도에서 90% 이상이었다. DO 농도 2.0, 1.5, 1.0, 0.75 mg/L에서의 TN 제거효율은 각각 50, 51, 54, 66%이었다. DO 농도 0.75 mg/L 조건에서 알럼을 첨가한 결과 TN 제거효율은 54%로 감소하였다. 혐기성 반응조에 알럼을 투입한 결과 TP 제거효율은 29%에서 95%로 향상되었다. 그리고 알럼 투입 후 분리막 모듈의 화학적 세정 주기는 15~20일부터 40~50일으로 늘어났다.

Nitrogen Removal and Behavior of Soluble Microbial Products (SMP) in the MBR Process with Intermittent Aerobic Condition

  • Cha, Gi-Cheol;Myoung Hwang
    • Korean Membrane Journal
    • /
    • 제3권1호
    • /
    • pp.1-8
    • /
    • 2001
  • A lab-scale submerged membrane bio-reactor (MBR) with intermittent aeration was carried out for investigating the behavior of soluble microbial products (SMP). The SMP concentration of mixed liquor at Run 1 accumulated immediately at the end of running and biodegradable SMP converted into non-biodegradable SMP, but it did not occurred at the Run 2 and 3. The SMP formation coefficient (k) at the anoxic phase was a little higher than oxic phase, and the lowest k was investigated at Run 3. The combination of biological denitrification with the MBR Process was advantageous in the prevention of membrane bio-fouling.

  • PDF

고농도 분말활성탄 결합 MBR 운전에 대한 활성탄 교체주기의 영향 (Effect of powder activated carbon replacement on HCPAC-MBR system operation)

  • 이채하;김진태;이정현;서규태;김인수
    • 상하수도학회지
    • /
    • 제22권1호
    • /
    • pp.141-148
    • /
    • 2008
  • This study was conducted to evaluate the effect of PAC(Powder Activated Carbon) retention time on stable operation of high concentration powered activated carbon(HCPAC-MBR) in the treatment of secondary domestic wastewater. The pilot scale HCPAC-MBR system was operated at two different SRTs, 25 days and 100 days. The main drawback of HCPAC-MBR system was the rapid increase of trans-membrane pressure. The increase rate of trans-membrane pressure was proportional to SRT value at constant flux. This result seemed to be caused by reduced amount of EPS adsorbed on the PAC in the reactor by decreasing the SRT of the PAC. The particle size of the PAC was also influenced by SRT. The PAC size was decreased as SRT was increased. The change of particle size could be one reason for the change of trans-membrane pressure. The pore volume in the cake-layer formed on the membrane surface became to be increased by reducing SRT, because the cake-layer was highly composed of the PAC. Therefore, increased pore volume might play a role to reduce the trans-membrane pressure. The removal rate of E260 and TOC was also inversely proportional to SRT value.

전기응집-MBR 공정의 전류밀도와 접촉시간이 막 오염에 미치는 영향과 막 오염 저감 속도론적 고찰 (Effect of current density and contact time on membrane fouling in electrocoagulation-MBR and their kinetic studies on fouling reduction rate)

  • 엄세은;장인성
    • 상하수도학회지
    • /
    • 제31권4호
    • /
    • pp.321-328
    • /
    • 2017
  • Recently EC-MBR (Elctrocoagulation - Membrane Bio Reactor) has been suggested as one of alternative processes to overcome membrane fouling problems. Most important operational parameters in the EC-MBR are known to current density and contact time. Their effect on membrane filtration performances has been reported well, however, quantitative interrelationship between both parameters not been investigated yet. The purpose of this study is to give a kinetic model suggesting the current density and the contact time required to reduce the membrane fouling. The 4 different set of current densities (2.5, 6, 12 and $24A/m^2$) and contact times (0, 2, 6 and 12 hr) were selected as operational parameters. After each electro-coagulation under the 16 different conditions, a series of membrane filtration was carried out. The membrane fouling decreased as the current density and contact time increased, Total fouling resistances under different conditions, $R_t(=R_c+R_f)$ were calculated and compared to those of the controls ($R_0$), which were calculated from the data of experiments without electro-coagulation. A kinetic approach for the fouling reduction rate ($R_t/R_0$) was carried out and the equation ${\rho}^{0.46}_it=7.0$ was obtained, which means that the product of current density and the contact time needed to reduce the fouling in certain amounts (in this study, 10% of fouling reduction) is always constant.

순산소의 MBR(Membrane Bio Reactor) 공정 적용을 통한 음식물류 폐기물 혐기성소화 유출수 처리 평가 (Evaluation of pure oxygen with MBR(Membrane Bio Reactor) process for anaerobic digester effluent treatment from food waste)

  • 박세용;김문일;박성혁
    • 유기물자원화
    • /
    • 제29권3호
    • /
    • pp.5-16
    • /
    • 2021
  • 본 연구에서는 MBR 공정 내 폭기조에서 순산소 용해와 일반 공기 폭기의 효율에 대한 비교·평가를 통해 순산소의 MBR 공정 적용성에 대해 평가 하였다. 순산소 장치에 의한 유기물 및 암모니아 산화 여부에 대해 평가하였으며, 실폐수(음식물류 폐기물의 혐기성소화 유출수) 적용 과포화산소용해 효율 평가를 진행하였다. 순산소용해와 일반공기폭기 방법의 SCOD, 암모니아 제거율과 속도는 비슷하였다. 하지만, 순산소 용해에 의한 미생물 수율이 일반공기폭기법에 의한 미생물 수율보다 약 0.03 g MLSS-produced/g SCOD-removed 낮아 잉여슬러지 처리 비용이 감소될 수 있을 것이라 판단된다. 음식물류 폐기물의 혐기성 소화 유출수의 고농도 유기물 (4,000 mg/L) 및 암모니아 (1,400 mg/L)의 제거율을 순산소용해와 일반공기폭기법을 비교한 결과, 순산소 용해기가 일반공기폭기법에 비해 유기물 제거율이 약 13% 가량 더 높게 평가되었다. 또한, MLSS의 경우 일반공기폭기법이 순산소장치에 비해 0.3배가량 높았다. 이는, 순산소장치의 경우 폭기조 내에 용존산소가 충분히 유지, 공급되기 때문에 슬러지 자산화가 고도로 진행된 결과로 판단되었다. 따라서, 고농도 유기물을 함유한 폐수 처리를 위한 방법으로는 기존에 많이 사용되었던 일반공기폭기법보다 순산소장치를 활용하는 것이 경제적인 면에서 더 유리할 것으로 판단되었다.

EC-MBR에서 전기응집이 슬러지 특성에 미치는 영향 (Effect of electrocoagulation on sludge characteristics in EC-MBR)

  • 엄세은;장인성
    • 한국산학기술학회논문지
    • /
    • 제18권12호
    • /
    • pp.42-49
    • /
    • 2017
  • 전기응집 공정은 MBR (Membrane Bio-Reactor) 공정의 막 오염을 해결하기 위한 일환으로 응용되고 있다. 본 연구는 전기응집 공정의 중요한 운전변수인 전류밀도와 접촉시간에 따른 활성슬러지의 특성 변화에 관한 연구를 수행하였다. 전류밀도를 2.5, 12, $24A/m^2$로, 접촉시간은 0, 2, 6 hr로 변화시켜 가며 활성슬러지의 특성 변화를 관찰하였다. 전류밀도 $24A/m^2$ 조건에서 6시간 동안 MLSS는 6,800에서 7,000 mg/L로 3% 증가하였고, MLVSS는 6,280에서 6,300 mg/L로 큰 변화가 없었다. 다른 전류밀도 조건 하에서도 동일한 경향이 관찰되었다. COD는 전류밀도가 $24A/m^2$일 때 71에서 37 mg/L로 감소하였고, $12A/m^2$일 때는 113에서 67 mg/L로, $2.5A/m^2$일 때는 84에서 80 mg/L로 감소하였다. 반면 TN과 TP는 전반적으로 큰 변화를 보이지 않았다. Soluble-EPS와 Bound-EPS는 전류밀도가 증가할수록 약간 감소하는 경향을 보였다. 전기응집을 거친 활성슬러지로 막 여과를 수행하여 여과성능이 개선되는지 평가하였다. 전기응집을 수행하지 않은 대조군에 비해 총여과저항 ($R_t$)이 6~61% 감소한 것으로 나타났다. 특히 전류밀도와 접촉시간이 증가할수록 막 여과 저항이 감소하는 것을 확인하였다. 이를 통해 전기응집 공정이 MBR 공정의 막 여과 성능 개선에 사용될 수 있음을 확인하였다.