Power Control modeling and Simulation of Hybrid Power System for Building Microgrid Connected Application

  • Yoon, Gi-Cap;Cho, Jae-Hoon;Hong, Won-Pyo
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.23 no.11
    • /
    • pp.84-93
    • /
    • 2009
  • In this paper, we propose to study the possibility of using a photovoltaic system combined with a high speed micro-turbine. This hybrid system can work as stand-alone system or grid connected system as it will be a part of a micro-grid. Initially, we propose Matlab/Simulink dynamic models of photovoltaic, micro turbine systems and supercapacitor. Then, we carry out a simulation comparison of the two systems, this is, with supercapacitor and without supercapacitor bank. We show that supercapacitor bank as short-term storage device was necessary to reduce the fast fluctuation of power in the case of sensitive loads. It is verified the simulation results of Matlab/Simulink based hybrid power system represent the effectiveness of the suggested hybrid power system.

A Study on the Grid-Connected Three-Phase PWM Inverter Using MATLAB/Simulink (MATLAB/Simulink를 이용한 계통연계형 3상 PWM 인버터의 연구)

  • Ahn, H.J.;Oum, J.H.;Jung, Y.G.;Lim, Y.C.;Kim, K.H.
    • Proceedings of the KIPE Conference
    • /
    • 2010.07a
    • /
    • pp.558-559
    • /
    • 2010
  • 화석연료의 사용으로 인한 환경문제로 신재생에너지 부분에 대한 관심이 증가하였다. 따라서 분산전원 시스템과 계통과의 연계 필요성이 증대되고, 이로 인해 계통연계형 인버터의 연구가 활발해지고 있다. 인버터를 계통과 연계하기위해서는 계통의 위상정보를 정확히 측정하여 인버터의 주파수와 위상이 동일한 상태로 전류가 공급되도록 해야 한다. 본 논문은 PWM을 이용한 3상 인버터를 고찰하였으며, 3상 D-Q 변환을 통한 PLL의 구조를 사용하여 인버터의 출력전압과 계통 전압의 위상을 동기화시켜 부하에 동일한 위상으로 공급되도록 하는 계통연계형 3상 PWM 인버터 시스템을 MATLAB/Simulink를 이용하여 구성하였다.

  • PDF

Torque Control Simulation of the Column Type EPS System using MATLAB/Simulink (MATLAB/Simulink를 이용한 컬럼형 전동조향장치(EPS)의 토크제어 시뮬레이션)

  • Pang Du-Yeol;Lee Seong-Cheol;Jang Bong-Chun
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2006.05a
    • /
    • pp.277-278
    • /
    • 2006
  • As a development of technology, electric power steering system which uses an electric motor came to use in recent and it can solve the problems with hydraulic power steering system. In this paper, vehicle model and electric power steering system are combined to fulfill full vehicle model. By simulation effect of motor torque assist through electric power steering revealed effective, and full vehicle model are proved reasonable through comparison with real car experimental datum.

  • PDF

A Study on the Mis-Function Analysis of Re-closer Based on the Matlab/Simulink (Matlab/Simulink를 이용한 리클로우저의 오동작 해석에 관한 연구)

  • Kim, Chan-Hyeok;Rho, Dae-Seok
    • Proceedings of the KAIS Fall Conference
    • /
    • 2008.11a
    • /
    • pp.72-75
    • /
    • 2008
  • 기존 배전계통에 있어서의 조류는 변전소에서 선로말단을 향한 단방향이지만, 분산전원이 연계된 배전계통의 경우에는 그 출력 용량의 여부에 따라 양방향의 전력조류가 발생할 가능성이 있어, 계통운용상 여러가지의 문제점이 야기될 수 있다. 특히, 태양광발전이 배전선로에 연계되어 운전되는 경우, 동일 뱅크의 타배전선로에서 사고가 발생하면 태양광발전이 연계된 건전한 배전선로의 보호협조기기(리클로져)가 오동작하는 사고가 발생하는 경우가 실 계통에서 빈번하게 발생하고 있다. 이에 의하여 건전한 선로의 부하가 정전을 경험하는 심각한 문제점이 발생한다. 따라서 본 논문에서는 MATLAB/SIMULINK을 이용하여 모델링과 시뮬레이션을 수행하여, 상기의 보호협조기의 오동작 문제점을 분석하고 해석하였다.

  • PDF

Transient-Sub transient Characteristic Modeling of Synchronous Generator using MATLAB-SIMULINK (MATLAB-SIMULINK를 이용한 동기발전기 과도-차과도 특성 모델링)

  • Lee, Gang;Jo, Jongmin;Kim, Jichan;Cha, Hanju
    • Proceedings of the KIPE Conference
    • /
    • 2019.11a
    • /
    • pp.164-165
    • /
    • 2019
  • 본 논문은 3상 동기발전기의 과도 특성을 분석하기 위해 MATLAB/ SIMULINK를 이용하여 모델링하였으며 동기발전기 출력단의 개방 및 3상 단락 회로 조건에 따른 특성곡선을 분석하였다. 정상상태, 과도상태 및 차과도상태 구간에서 고정자 권선, 회전자 권선 및 댐퍼 권선 등이 갖는 자기 인덕턴스 및 상호 인덕턴스 특성 관계와 자속 변화특성 등을 수학적 모델 기반의 소신호 모델링을 통해 3상 동기발전기를 등가적으로 모델링하였다. 시뮬레이션을 통해 얻은 값에 의해 과도상태와 차과도상태의 모터 데이터를 분석하고 단락상태의 시간 상수를 계산하여, 동기발전기의 3상 단락 조건에서 초기 과도 및 과도상태의 특성을 검증하였다.최종적으로, 이론적 공식에 의해 계산 된 동기 발전기의 파라미터는 시뮬레이션 결과와 일치하며 오차는 2 % 범위 내에 있다.

  • PDF

Evaluation on Effect of Wind Power Generation System According to Transformer Winding Connection at Matlab&Simulink (MATLAB&SIMULINK에서 변압기 결선에 따른 풍력발전 시스템의 영향 평가)

  • An, Hae-Joon;Ro, Kyoung-Soo
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.772-773
    • /
    • 2007
  • This study suggests a modeling of grid-connected wind power generation system that has induction generator, and aims to perform simulations for outputs by the variation of actual wind speed and for fault current of wind generation system by the transformer winding connection. This study is implemented by matlab&simulink. The simulation shall be performed by assuming single line to ground fault generated in the system. Generator power, rotor speed, terminal voltage, system voltage, and fault current shall be observed following the performance of simulation. The fault current change will be dealt through the simulation results for fault current of wind generation system following the grid-connected transformer winding connection and the simulation result by the transformer neutral ground method.

  • PDF

Motor control by using MATLAB/SIMULINK Auto Code Generation (MATLAB/SIMULINK의 Auto Code Generation을 이용한 전동기 제어)

  • Lee, Seul-Ki;Jeong, Hyeon-Woo;Oh, Hyoung-Lok;Lee, Jun-young
    • Proceedings of the KIPE Conference
    • /
    • 2012.07a
    • /
    • pp.77-78
    • /
    • 2012
  • 본 논문에서는 모터와 인버터 그리고 제어기를 모델로 작성하여 시뮬레이션하고, 제어기 모델로부터 자동코드생성을 하여 작성한 코드를 실제 제어기에 탑재하여 모터모델의 시뮬레이션 및 실제 모터를 구동하였다. 제어기와 모터 그리고 인버터 모델은 MATLAB/SIMULINK를 이용하여 작성하였다. 모터 모델과 실제 모터의 동작을 통해 제어기의 성능을 검증하였다. PWM은 10[kHz]로 동작하며, 이를 검증하기 위해 400[W] 표면부착형 동기모터 다이나모 장치와 3상 모터 드라이버를 이용하여 시험을 수행 하였다.

  • PDF

A Study on the Cooperative Kinematic Inter-operation of 2-Axis (Tilting/Rolling) Additional Axes with a 6-Axis Articulated Robot Using Simulink of MATLAB and Recurdyn (MATLAB과 Recurdyn의 Simulink를 활용한 2축 부가 축과 6축 수직 다관절로봇의 기구적 연동에 관한 연구)

  • Bae, Seung-Min;Chung, Won-Jee;Noh, Seong-Hoon
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.20 no.4
    • /
    • pp.16-23
    • /
    • 2021
  • Currently, 6-axis articulated robots are used throughout the industry because of their 6-dof (degrees of freedom) and usability. However, 6-axis articulated robots have a fixed base and their movements are limited by the rotational operating range of each axis. If the angle of the 2-axis additional axes can be adjusted according to the position and orientation of the end-effector of the 6-axis articulated robot, the effectiveness of the 6-axis articulated robot can be further increased in areas where the angle is important, such as welding. Therefore, in this paper, we proposed a cooperative kinematic inter-operation strategy. The strategy will be verified using the Simulink of MATLABⓇ, an engineering program, and RecurdynⓇ, a dynamic simulation program.

Simulation for Voltage Variation of a Permanent Magnetic Synchronous Generator Wind Turbine Systems on Simulink (Simulink에서 영구자석 동기형 풍력발전시스템의 전압변동에 대한 시뮬레이션)

  • An, Hae-Joon;Kim, Hyun-Goo;Kim, Hong-Woo;Jang, Gil-Soo
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2010.06a
    • /
    • pp.184.2-184.2
    • /
    • 2010
  • This study performs modelling and simulation of permanent magnetic synchronous generator wind turbine by using Matlab & Simulink. In simulation, change of wind velocity, change of load, and voltage decrease of infinite bus are performed. Through such simulation, different with wiring system that there is only existing load, this study can confirm problems and voltage changing characteristics, which can occur in distributed electric power that load and electric power is mixed and operated, especially, in interconnecting with wind power generation.

  • PDF

Simulation for Voltage Variations of a Grid-connected Wind Turbine Generation System by Simulink (Simulink에서 계통연계 풍력발전시스템의 전압변동 시뮬레이션)

  • Ahn Duck-Keun;Ro Kyoung-Soo
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.53 no.11
    • /
    • pp.589-595
    • /
    • 2004
  • This paper presents a modeling and simulation of a grid-connected wind turbine generation system with respect to wind variations, starting of large induction motor and three-phase fault in the system, and investigates voltage variations of the system for disturbances. It describes the modeling of the wind turbine system including the drive train model, induction generator model, and grid-interface model on MATLAB/Simulink. The simulation results show the variation of the generator torque, the generator rotor speed, the pitch angle, terminal voltage, system voltage, fault current, and real/reactive power output, etc. Case studies demonstrate that the pitch angle control is carried out to achieve maximum power extraction for wind speed variations, starting of a large induction motor causes a voltage sag due to a large starting current, and a fault on the system influences on the output of the wind turbine generator.