• Title/Summary/Keyword: MASS LOSS RATE

Search Result 400, Processing Time 0.025 seconds

Incombustibility of Polypropylene by Metal Addition Flame Retardant (폴리프로필렌의 금속첨가형 난연제에 의한 난연 특성)

  • Lee, Sang-Eun;Song, Young-Ho;Chung, Kook-Sam
    • Journal of the Korean Society of Safety
    • /
    • v.20 no.4 s.72
    • /
    • pp.40-45
    • /
    • 2005
  • The principal actions of a flame retardant are to decrease or prevent the formation of volatile products and increase the formation of char layer. Use of flame retardant additives can decrease the overall fire hazard of the product containing them thus leading to an increase in overall fire safety. Although several flame retardants have been developed for use in polymers, many of these are known to increase the amount of smoke and toxic gases generated by them. This paper present a new flame retardant using metal addition flame retardant. For this study, the experiments of flame retardancy conducted are as follows : burning ratio, weight loss rate using TGA-DTA, the measurement of LOI and char yield. And smoke mass concentration and CO yield were measured. The metal addition flame retardant reduced burning ratio and weight loss rate, increased the LOI and yield of char formation with decreased smoke mass concentration and CO yield.

A Study on the Fire Hazards of Puzzle Mats in Group Day Care Home (놀이방 퍼즐매트의 화재위험성에 관한 연구)

  • Park, Hyung-Ju
    • Journal of the Korean Society of Safety
    • /
    • v.23 no.5
    • /
    • pp.73-78
    • /
    • 2008
  • The fire hazards and combustion heat of puzzle mats in group day care home were analysed using variable external irradiation level. The fire hazards such as ignition time, ignition temperature, mass loss rate, and flame temperature profile were measured. Incident heat fluxes of $15kW/m^2$, $20kW/m^2$, $25kW/m^2$, $35kW/m^2$, $50kW/m^2$ and $75kW/m^2$ were selected for these experiments. All samples were tested in the horizontal orientation and were wrapped in a single layer of aluminium foil. Each sample was nominally 20mm thick and 100mm square. Five samples of puzzle mat were tested in the study : Type A, B, C, D and E. Type A, B and C are all general grades whereas Type D and E are both Flame retardant grades. As results, Type E of FR-grade showed the best characteristics in safety of the early fire from ignition time, critical heat flux, and ignition and flame temperature data of this study. All specimen of G-grade(Type A, B and C), however, showed the weak in safety of fire.

Effects of Mahuang for Weight Loss in Healthy Adults : A Double-Blind, Controlled, Randomized, Clinical Trial (마황복용이 성인의 체중감소에 미치는 영향에 대한 이중맹검 임상연구)

  • Yeo, Jin-Ju;Hsing, Li-Chang;Yang, Chang-Sub;Jeong, Seung-Il;Seo, Eui-Seok;Jang, In-Soo
    • The Journal of Korean Medicine
    • /
    • v.28 no.1 s.69
    • /
    • pp.63-71
    • /
    • 2007
  • Objectives : To provide an objective assessment of the effectiveness for weight loss of Mahuang. Methods : Effects were assessed by measuring changes in body weight, body mass index (BMI), body fat (kg, %),body muscle, and abdominal f3t ratio. The subjects of this study were healthy adults who agreed to participate in this study. Eligibility requirements include age between 20 and 50 and BMI more than 18.5 kg/m2. One hundred subjects were randomly assigned to two groups (control and Mahuang group) in a double-blind manner. Mahuang group subjects took 8g of Mahuang capsule/day for two weeks; control subjects took the same amount of indistinguishable placebo. We analyzed the body weight, body mass index, body fat, abdominal fat, body muscle and BMR (basal metabolic rate) before and after the study. Result After two weeks of clinical trial, body weight and BMI decreased in both groups, but the Mahuang group showed more significant decrease. On body fat, the Mahuang group showed significant decrease. while it increased in the placebo group. Although body muscle, body fat ratio and basic metabolic rate showed differences between the two groups, there was no statistical significance. Conclusion : It is suggested that intake of Mahuang may induce weight loss and body f3f decrease in healthy adults.

  • PDF

Performance degradation due to compressor fouling of an industrial gas turbine operating at design point condition (막오염에 의한 압축기 성능 저하가 발전용 가스터빈 설계점 성능에 미치는 영향에 관한 연구)

  • Seo, J.S.;Sohn, J.L.;Kim, J.H.;Kim, T.S.;Ro, S.T.
    • The KSFM Journal of Fluid Machinery
    • /
    • v.6 no.3 s.20
    • /
    • pp.36-43
    • /
    • 2003
  • Operating performance of industrial gas turbines in combined cycle power plants depends upon atmospheric conditions. Compressor fouling caused by airborne particles in the atmosphere and their adhesions on compressor blades is one of critical phenomena related to the performance degradation of industrial gas turbines. Compressor fouling provokes increase of pressure loss in inlet duct, decrease of mass flow rate of intake air and decrease of compressor stage efficiency. In this study, impacts of compressor fouling on the performance of an industrial gas turbine operating at design point condition are investigated analytically. As results, it is found that the reduction of produced power with decreased mass flow rate of intake air caused by narrowed flow area by the adhesion of airborne particles on compressor blades is the most dominant impact on the gas turbine performance by the compressor fouling phenomena.

1.64 ${\mu}m$ features of Jets and Outflows from Young Stellar Objects in the Carina Nebula

  • Shinn, Jong-Ho;Pyo, Tae-Soo;Lee, Jae-Joon;Lee, Ho-Gyu;Kim, Hyun-Jeong;Koo, Bon-Chul;Sung, Hwankyung;Chun, Moo-Young;Lyo, A. Ran;Moon, Dae-Sik;Kyeong, Jaemann;Park, Byeong-Gon;Hur, Hyeonoh;Lee, Yong-Hyun
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.39 no.1
    • /
    • pp.56.2-56.2
    • /
    • 2014
  • We present [Fe II] 1.64 ${\mu}m$ imaging observations for jets and outflows from young stellar objects over the northern part (${\sim}24^{\prime}{\times}45^{\prime}$) of the Carina Nebula, a massive star forming region. The observations were performed with IRIS2 of Anglo-Australian Telescope and the seeing was ~1.5". Eleven jets and outflows features are detected at eight different regions, and are termed as Ionized Fe Objects (IFOs). The [Fe II] features have knotty or elongated shapes, and the detection rate of IFOs against previously identified YSOs is 1.4%. Four IFOs show anti-correlated peak intensities in [Fe II] and $H{\alpha}$, where the ratio I([Fe II])/I($H{\alpha}$) is higher for longish IFOs than for knotty IFOs. We estimate the outflow mass loss rate from the [Fe II] flux using two different methods. The jet-driving objects are identified for three IFOs (IFO-2, -4, and -7). The ratios of the outflow mass loss rate over the disk accretion rate for IFO-4 and -7 are consistent with the previously reported values ($10^{-2}-10^{+1}$), while the ratio is higher for IFO-2. This excess may result from underestimating the disk accretion rate. Other YSO physical parameters show reasonable relations or trends.

  • PDF

Changes in Fire Characteristics according to the Distance Between the Fire Source and Sidewall in a Reduced-Scale Compartment (축소 구획실에서 화원과 측벽의 거리에 따른 화재특성 변화)

  • Yun, Hong-Seok;Hwang, Cheol-Hong
    • Fire Science and Engineering
    • /
    • v.33 no.1
    • /
    • pp.50-59
    • /
    • 2019
  • Experimental and numerical studies on the fire characteristics according to the distance between the fire source and sidewall under the over-ventilated fire conditions. A 1/3 reduced ISO 9705 room was constructed and spruce wood cribs were used as fuel. Fire Dynamics Simulator (FDS) was used for fire simulations to understand the phenomenon inside the compartment. As a result, the mass loss rate and heat release rate were increased due to the thermal feedback effect of the wall in the compartment fire compared to the open fire. As the distance between the fire source and sidewall was reduced, the major fire characteristics, such as maximum mass loss rate, heat release rate, fire growth rate, temperature, and heat flux, were increased despite the limitations of air entrainment into the flame. In particular, a significant change in these physical quantities was observed for the case of a fire source against the sidewall. In addition, the vertical distribution of temperature was changed considerably due to a change in the flow structure inside the compartment according to the distance between the fire source and sidewall.

Effects of the Low Reynolds Number on the Loss Characteristics in a Transonic Axial Compressor

  • Choi, Min-Suk;Oh, Seong-Hwan;Ko, Han-Young;Baek, Je-Hyun
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2008.03a
    • /
    • pp.202-212
    • /
    • 2008
  • A three-dimensional computation was conducted to understand effects of the low Reynolds number on the loss characteristics in a transonic axial compressor, Rotor67. As a gas turbine becomes smaller in size and it is operated at high altitude, the operating condition frequently lies at low Reynolds number. It is generally known that wall boundary layers are thickened and a large separation occurs on the blade surface in axial turbomachinery as the Reynolds number decreases. In this study, it was found that the large viscosity did not affect on the bow shock at the leading edge but significantly did on the location and the intensity of the passage shock. The passage shock moved upstream towards leading edge and its intensity decreased at the low Reynolds number. This change had large effects on the performance as well as the internal flows such as the pressure distribution on the blade surface, tip leakage flow and separation. The total pressure rise and the adiabatic efficiency decreased about 3% individually at the same normalized mass flow rate at the low Reynolds number. In order to analyze this performance drop caused by the low Reynolds number, the total pressure loss was scrutinized through major loss categories such as profile loss, tip leakage loss, endwall loss and shock loss.

  • PDF

Osmotic Concentration of Apples and Its Effect on Browning Reaction during Air Dehydration (사과의 삼투압농축과 열품건조시 갈색화 반응에 미치는 효과)

  • 김명환
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.19 no.2
    • /
    • pp.121-126
    • /
    • 1990
  • Internal mass transfer during osmotic concentration of apples in sugar solutions was exami-ned as a function of concentration temperature and immersion time of those solutions using moisture loss sugar gain molality and rate parameter. Influence of osmotic concentration processes on browning reaction was also evaluated compared to control In creasin the concen-tration and temperature of sugar solutions increased moistrue loss sugar gain molality and rate parameter. Water loss was rapid early in the process and then levelled off, The same phenomena were occurred on sugar gain only in higher concentration(60$^{\circ}$ brix). IN lower concentration (30$^{\circ}$brix) sugar gain was gradually increased during whole process. Moisture loss during osmotic concentration using a sugar solution(60$^{\circ}$ brix 6$0^{\circ}C$) with 180min immer-sion time was 45.79% Effect of osmotic concentration befor air dried to 4% M.C(wet basis) on browning reaction was significant. Minimum browning reaction during air drying was carried out using a pretreatment such as osmotic concentration in sugar solution(60$^{\circ}$brix 45$^{\circ}C$) with 150min immersion time(O.D=0.01) compared to control(O.D=0.17)

  • PDF

Sensitivity Analysis of the CMB Modeling Results by Considering Photochemical Degradation of Polycyclic Aromatic Hydrocarbons (PAHs) in the Seoul atmosphere (서울 대기에서 PAHs 광화학반응을 고려한 CMB 수용모델 결과 검토)

  • Cho, Ye Seul;Jung, Da Bin;Kim, In Sun;Lee, Ji Yi;Kim, Yong Pyo
    • Particle and aerosol research
    • /
    • v.10 no.1
    • /
    • pp.9-17
    • /
    • 2014
  • Several studies have been carried out on the source contribution of the particulate Polycyclic Aromatic Hydrocarbons (PAHs) over Seoul by using the Chemical Mass Balance Model (CMB)(Lee and Kim, 2007; Kim et al., 2013). To confirm the validity of the modeling results, the modified model employing a photochemical loss rate along with varying residence times and the standard model that considers no loss were compared. It was found that by considering the photochemical loss rate, a better performance was obtained as compared to those obtained from the standard model in the CMB calculation. The modified model estimated higher contributions from coke oven, transportation, and biomass burning by 4 to 8%. However, the order of the relative importance of major sources was not changed, coke oven followed by transportation and biomass burning. Thus, it was concluded that the standard CMB model results are reliable for identifying the relative importance of major sources.

Analytical Methods of Leakage Rate Estimation from a Containment tinder a LOCA (냉각수상실 사고시 격납용기로부터 누출되는 유체유량 추산을 위한 해석적 방법)

  • Moon-Hyun Chun
    • Nuclear Engineering and Technology
    • /
    • v.13 no.3
    • /
    • pp.121-129
    • /
    • 1981
  • Three most outstanding maximum flow rate formulas are identified from many existing models. Outlines of the three limiting mass flow rate models are given along with computational procedures to estimate approximate amount of fission products released from a containment to environment for a given characteristic hole size for containment-isolation failure and containment pressure and temperature under a loss of coolant accident. Sample calculations are performed using the critical ideal gas flow rate model and the Moody's graphs for the maximum two-phase flow rates, and the results are compared with the values obtained from the mass leakage rate formula of CONTEMPT-LT code for converging nozzle and sonic flow. It is shown that the critical ideal gas flow rate formula gives almost comparable results as one can obtain from the Moody's model. It is also found that a more conservative approach to estimate leakage rate from a containment under a LOCA is to use the maximum ideal gas flow rate equation rather than tile mass leakage rate formula of CONTEMPT-LT.

  • PDF