• Title/Summary/Keyword: MARD

Search Result 16, Processing Time 0.026 seconds

Output characteristics of a confocal unstable resonator copper vapor laser (공초점 불안정공진기 구리증기레이저의 출력특성)

  • 정지철;유영태;윤재순;백세종;임기건
    • Korean Journal of Optics and Photonics
    • /
    • v.10 no.3
    • /
    • pp.221-225
    • /
    • 1999
  • The positive branch confocal unstable resonator equipped with an intra-cavity beam splitter has been studied experimentally to achieve low beam divergence in the copper vapor laser. Output laser beams of 0.15 mrad divergence was achieved from the laser system with a 10 cm curvature convex mirror (M=30), and laser beams of 0.1 mrad was achieved for a 5 cm curvature convex mirror (M=60). The power density of the far-field beam from the M=60 resonator laser was 130 times higher than the case of the 2 mrad-operation with the plane-parallel resonator. We also observed the self-mode-locking from the unstable resonator laser pulses.

  • PDF

Development of UAV Teleoperation Virtual Environment Based-on GSM Networks and Real Weather Effects

  • AbdElHamid, Amr;Zong, Peng
    • International Journal of Aeronautical and Space Sciences
    • /
    • v.16 no.3
    • /
    • pp.463-474
    • /
    • 2015
  • Future Ground Control Stations (GCSs) for Unmanned Aerial Vehicles (UAVs) teleoperation targets better situational awareness by providing extra motion cues to stimulate the vestibular system. This paper proposes a new virtual environment for long range Unmanned Aerial Vehicle (UAV) control via Non-Line-of-Sight (NLoS) communications, which is based on motion platforms. It generates motion cues for the teleoperator for extra sensory stimulation to enhance the guidance performance. The proposed environment employs the distributed component simulation over GSM network as a simulation platform. GSM communications are utilized as a multi-hop communication network, which is similar to global satellite communications. It considers a UAV mathematical model and wind turbulence effects to simulate a realistic UAV dynamics. Moreover, the proposed virtual environment simulates a Multiple Axis Rotating Device (MARD) as Human Machine Interface (HMI) device to provide a complete delay analysis. The demonstrated measurements cover Graphical User Interface (GUI) capabilities, NLoS GSM communications delay, MARD performance, and different software workload. The proposed virtual environment succeeded to provide visual and vestibular feedbacks for teleoperators via GSM networks. The overall system performance is acceptable relative to other Line-of-Sight (LoS) systems, which promises a good potential for future long range, medium altitude UAV teleoperation researches.

Analytical Evaluation of PPG Blood Glucose Monitoring System - researcher clinical trial (PPG 혈당 모니터링 시스템의 분석적 평가 - 연구자 임상)

  • Cheol-Gu Park;Sang-Ki Choi;Seong-Geun Jo;Kwon-Min Kim
    • Journal of Digital Convergence
    • /
    • v.21 no.3
    • /
    • pp.33-39
    • /
    • 2023
  • This study is a performance evaluation of a blood sugar monitoring system that combines a PPG sensor, which is an evaluation device for blood glucose monitoring, and a DNN algorithm when monitoring capillary blood glucose. The study is a researcher-led clinical trial conducted on participants from September 2023 to November 2023. PPG-BGMS compared predicted blood sugar levels for evaluation using 1-minute heart rate and heart rate variability information and the DNN prediction algorithm with capillary blood glucose levels measured with a blood glucose meter of the standard personal blood sugar management system. Of the 100 participants, 50 had type 2 diabetes (T2DM), and the average age was 67 years (range, 28 to 89 years). It was found that 100% of the predicted blood sugar level of PPG-BGMS was distributed in the A+B area of the Clarke error grid and Parker(Consensus) error grid. The MARD value of PPG-BGMS predicted blood glucose is 5.3 ± 4.0%. Consequentially, the non-blood-based PPG-BGMS was found to be non-inferior to the instantaneous blood sugar level of the clinical standard blood-based personal blood glucose measurement system.

A Study on Sterilization of Medical Products by Gamma-irradiation. (Gamma선 조사에 의한 의류제품의 멸균연구)

  • 정해원;정문식;문석형
    • Journal of Environmental Health Sciences
    • /
    • v.5 no.1
    • /
    • pp.1-9
    • /
    • 1978
  • Biological safety, physico-chemical and microbiological experiments were carried out in order to study the possibility of radiation sterilization on medical products, such as polyethylene and polystyrene bottles, gauze sponges and surgical silk suture. Results are as follows: 1. Biological test on plastic samples as to acute systemic toxicity, eye irritation, skin irritation, pyrogen, haemolysis showed satisfactory results. But physico-chemically, the oxidizable matter, nonvolatile residues, residue on ignition seemed to be increased slightly in irradiated samples, though the experimental results were within the range of U.S.P. 19, N.F. and K.P. III. 2. After irradiation, both plastic and gauze sponges showed considerable decrease in pH. 3. Most medical products were sterilized by 1.5 Mard. For the sterilization of the suigical silk suture, 4.5 Mrad is required dul to its radiation resistant micro-organisms. 4. Biologically, total dose of 2.5 Mrad was safe enough to sterilize the medical products, and physico-chemically the results are acceptable according to U.S.P. 19 and K.P. III. However, better results may be expected when the quality of material and additives are improved.

  • PDF

Electrical Properties of Transformer Oils due to Electron Beam Irradiation (전자선 조사에 따른 변압기유의 전기적 특성)

  • 이용우;조돈찬;홍진웅
    • Electrical & Electronic Materials
    • /
    • v.10 no.8
    • /
    • pp.756-762
    • /
    • 1997
  • In this paper the change of electrical properties of transformer oil due to electron beam irradiation is investigated. The specimens are produced with a some different dose of 0.5[Mrad], 1[Mrad] and 2[Mard] except for original specimen. The physical properties of each specimen is analyzed by using the FT-IR spectrum. So it is confirmed that carbonyl groups are increased according to the increase of electron beam dose and also that the nitric compounds are disappeared. The magnitude of dielectric dissipation factor appears maximum value by the contribution of dipoles and ions in the low temperature low voltage region and it is stable due to the saturation of carriers in the high temperature high voltage region in the electric conduction characteristics. Volume resistivity is also measured one of original specimen is larger than irradiated specimen.

  • PDF

Output Characteristics of a Q-Switched Nd:YAG laser with GRM(Gaussian Reflectivity Mirror) unstable resonator (GRM(Gaussian Reflectivity Mirror)을 이용한 불안정 공진기형 Q-스위치 Nd:YAG 레이저의 출력특성)

  • Lee, Hee-Chul;Kim, Yong-Pyung
    • Korean Journal of Optics and Photonics
    • /
    • v.16 no.2
    • /
    • pp.152-158
    • /
    • 2005
  • We investigated the operational characteristics of a Q-switched Nd:YAG laser, which has an unstable resonator with a GRM(Gaussian reflectivity mirror). With electrical input energy of 55 J, we obtained the fundamental energy of 470 mJ at 1064 nm and the frequency doubled energy of 280 mJ at 532 nm. The Top-Hat profile of the output beam was obtained at the near field, and beam divergence was 1.7 mard.

High Resolution Electronic Processor Design for Thermal Imager with 320x240 Staring Array Infrared Detector (320x240 적외선 배열검출기를 이용한 고분해능 열상 신호처리기 구현)

  • Hong, Seok-Min;Yu, Wee-Kyung;Yoon, Eun-Suk
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.9 no.2 s.25
    • /
    • pp.111-117
    • /
    • 2006
  • This paper describes the design principles and methods of electronic processor for thermal imager with 320$\times$240 staring array infrared detector. For the detector's nonuniformity correction and excellent image quality, we have designed the multi-point correction method using the defocusing technique of the optics. And to enhance the image of low contrast and improve the detection capability, the new technique of histogram processing has been designed. Through these image processing techniques, we have developed the high quality thermal imager and acquired a satisfactory thermal image. The result of MRTD(Minimum Resolvable Temperature Difference) is $0.1^{\circ}C$ at 4cycles/mard.

Trends in Non-invasive Continuous Glucose Monitoring Technology (비침습 연속혈당 모니터링 기술동향)

  • Kim, J.;Kim, B.K.
    • Electronics and Telecommunications Trends
    • /
    • v.36 no.5
    • /
    • pp.9-20
    • /
    • 2021
  • A technology to replace the traditional blood sampling method for glucose monitoring has been sought for a long time. It is now possible to measure the blood glucose change rate continuously for more than 24 hours using a minimally invasive method that does not involve blood collection. Furthermore, various technology development efforts are being made for innovative diabetes management through intermittent or continuous blood glucose monitoring in a non-invasive manner. In this paper, we present an overview of diabetes and the need for continuous blood glucose measurement techniques., and then introduce various non-invasive blood glucose measurement techniques currently being studied. In addition, through research and analysis of the recent commercialization development status of minimally invasive, non-invasive, and wearable continuous blood glucose measurement technologies, we examine global development trends of future technologies.

A Study on the Preparation of Wood-Plastic Combination(I) - General Properties and Radiation Durabilities of Woods

  • Pyun, Hyung-Chick;Lee, Kyung-Hee;Kim, Jaerok
    • Nuclear Engineering and Technology
    • /
    • v.5 no.2
    • /
    • pp.150-158
    • /
    • 1973
  • General physical properties and radiation durabilities of some domestic woods and imported lauans were measured and discussed as a preliminary study on the preparation of W. P. C. The data obtained indicate that 1) the hardness of wood is generally proportional to the specific gravity and to the bending strength, 2) the hardness of wood measured in tangential direction to the annual ring increases along with the distance from the center of the annual ring to the peel, 3) the changes of specific gravity under 100 Mrad gamma irradiation are not remarkable, 4) the hardnesses of the soft woods are decreased more -readily than those of the hard woods, but the decreases of hardnesses are not extreme upto 10 Mrad sugges ting that the woods are sufficiently durable to gamma irradiation of below 10 Mard in the preparation of W. P. C.

  • PDF