DOI QR코드

DOI QR Code

Trends in Non-invasive Continuous Glucose Monitoring Technology

비침습 연속혈당 모니터링 기술동향

  • Published : 2021.10.01

Abstract

A technology to replace the traditional blood sampling method for glucose monitoring has been sought for a long time. It is now possible to measure the blood glucose change rate continuously for more than 24 hours using a minimally invasive method that does not involve blood collection. Furthermore, various technology development efforts are being made for innovative diabetes management through intermittent or continuous blood glucose monitoring in a non-invasive manner. In this paper, we present an overview of diabetes and the need for continuous blood glucose measurement techniques., and then introduce various non-invasive blood glucose measurement techniques currently being studied. In addition, through research and analysis of the recent commercialization development status of minimally invasive, non-invasive, and wearable continuous blood glucose measurement technologies, we examine global development trends of future technologies.

Keywords

Acknowledgement

이 논문은 산업통상자원부 사업의 일환으로 수행되었음[20012531].

References

  1. https://en.wikipedia.org/wiki/Diabetes
  2. https://www.mk.co.kr/news/it/view/2020/11/1167916
  3. http://www.ikunkang.com/news/articleView.html?idxno=21762
  4. https://en.wikipedia.org/wiki/Hypoglycemia
  5. https://medicalxpress.com/news/2021-03-painless-glucose-evidence-diabetes-patients.html
  6. 김재현, "2019년 한국의 지속혈당감시 장치," 대한내분비학회소식지, 제12권 제4호, 2019.
  7. T. Siegmund et al., "Discrepancies between blood glucose and interstitial glucose. technological artifacts or physiology: Implications for selection of the appropriate therapeutic target," J. Diabetes Sci. Technol. vol. 11, no. 4, 2017, pp. 766-772. https://doi.org/10.1177/1932296817699637
  8. S. Liu, W. Su, and X. Ding, "A review on microfluidic paper-based analytical devices for glucose detection," Sensors, vol. 16, no. 12, 2016.
  9. H. Lee et al., "Wearable/disposable sweat-based glucose monitoring device with multistage transdermal drug delivery module," Sci. Adv. vol. 3, no. 3, 2017.
  10. D.H. Keum et al., "Wireless smart contact lens for diabetic diagnosis and therapy," Sci. Adv. vol. 6, no. 17, 2020.
  11. A.E. Kownacka et al., "Clinical evidence for use of a noninvasive biosensor for tear glucose as an alternative to painful finger-Prick for diabetes management utilizing a biopolymer coating," Biomacromolecules, vol. 19, no. 11, 2018, pp. 4504-4511. https://doi.org/10.1021/acs.biomac.8b01429
  12. W.V. Gonzales et al., "The progress of glucose monitoring. a review of invasive to minimally and non-invasive techniques, devices and sensors," Sensors, vol. 19, no. 4, 2019. https://doi.org/10.3390/s19040933
  13. T. Danne et al., "International consensus on use of continuous glucose monitoring," Diabetes Care, vol. 40, no. 12, 2017, pp. 1631-1640. https://doi.org/10.2337/dc17-1600
  14. T. Lin et al., "The accuracy of a non-invasive glucose monitoring device does not depend on clinical characteristics of people with type 2 diabetes mellitus," J. Drug Assess. vol. 7, no. 1, 2018, pp. 1-7. https://doi.org/10.1080/21556660.2018.1423987
  15. A. Pfutzner et al., "Evaluation of a new noninvasive glucose monitoring device by means of standardized meal experiments," J. Diabetes Sci. Tech. vol. 12, no. 6, 2018, pp. 1178-1183. https://doi.org/10.1177/1932296818758769