• Title/Summary/Keyword: M2M Device

Search Result 2,299, Processing Time 0.033 seconds

Recent Trends in Standards Related to the Internet of Things and Machine-to-Machine Communications

  • Husain, Syed;Prasad, Athul;Kunz, Andreas;Papageorgiou, Apostolos;Song, JaeSeung
    • Journal of information and communication convergence engineering
    • /
    • v.12 no.4
    • /
    • pp.228-236
    • /
    • 2014
  • One of major purposes of these standard technologies is to ensure interoperability between entities from different vendors and enable interworking between various technologies. As interoperability and interworking are essential for machine-to-machine communications (M2M) and Internet of Things (IoT) for them to achieve their ultimate goal, i.e., things to be connected each other, multiple standards organizations are now working on development M2M/IoT related specifications. This paper reviews the current activities of some of the most relevant standardization bodies in the area of M2M and IoT: third-generation partnership project (3GPP) core and radio network aspects, broadband forum, and oneM2M. The major features and issues being focused upon in these standards bodies are summarized. Finally, some key common trends among the different bodies are identified: a common service layer platform, new technologies mitigating an explosive growth of network traffic, and considerations and efforts related to the development of device management technologies.

Cyclic Properties of Li[Co0.17Li0.28Mn0.55]O2 Cathode Material

  • Park, Yong-Joon;Hong, Young-Sik;Wu, Xiang-Lan;Kim, Min-Gyu;Ryu, Kwang-Sun;Chang, Soon-Ho
    • Bulletin of the Korean Chemical Society
    • /
    • v.25 no.4
    • /
    • pp.511-516
    • /
    • 2004
  • A Li$[Co_{0.17}Li_{0.28}Mn_{0.55}]O_2$ cathode compound was prepared by a simple combustion method. The X-ray diffraction pattern showed that this compound could be classified as ${\alpha} -NaFeO_2$ structure type with the lattice constants of a = 2.8405(9) ${\AA}$ and c = 14.228(4) ${\AA}$. According to XANES analysis, the oxidation state of Mn and Co ions in the compound were 4+ and 3+, respectively. During the first charge process, the irreversible voltage plateau at around 4.65 V was observed. The similar voltage-plateau was observed in the initial charge profile of other solid solution series between $Li_2MnO_3\;and\;LiMnO_2$ (M=Ni, Cr...). The first discharge capacity was 187 mAh/g and the second discharge capacity increased to 204 mAh/g. As the increase of cycling number, one smooth discharge profile was converted to two distinct sub-plateaus and the discharge capacity was slowly decreased. From the Co and Mn K-edge XANES spectra measured at different cyclic process, it can be concluded that irreversible transformation of phase is occurred during continuous cycling process.

Fabrication and pH response characteristics of LAPS(Light addressable potentiometric sensor) with electrolyte/$Si_3N_4/SiO_2$/Si structure (Electrolyte/$Si_3N_4/SiO_2/Si$ 구조의 LAPS 제작 및 pH 응답특성)

  • Chang Su-Won;Koh Kwang-Nak;Kang Shin-Won
    • Journal of the Korean Electrochemical Society
    • /
    • v.1 no.1
    • /
    • pp.40-44
    • /
    • 1998
  • The LAPS device of fast response and high sensitivity, based on electrochemical potential difference, and its system were fabricated for the precise measurement of pH changes and its characteristic were investigated. The electrostatic variation characteristics of LAPS according to the pH changes and parameters in the device were verified through a simulation using LAPS equivalent circuit model. The LAPS device and its system were fabricated on the basis of the result of simulation. The fabricated LAPS system showed linear sensitivity (about 56 mV/pH within the range of pH 2 to pH 11. In order to overcome the defect of general urea sensor (especially slow response time), urease immobilized nitrocellulose membrane was attached on the LAPS and resulted in the very fast response time, 0.29 mV/sec, 0.86 mV/sec at urea concentration of $50{\mu}g/ml,\; 500{\mu}g/ml$, respectively. And also in order to measure the uranyl ion, the uranyl ion selective sensing membrane with calix[6]arene derivative was used and its sensitivity was 25mV/concentration decade in the wide uranyl ion concentration range of $10^{-11}M\;to\;10^{-4}M$.

Facile Chemical Growth of Cu(OH)2 Thin Film Electrodes for High Performance Supercapacitors (간단한 화학적 합성을 통한 고성능 슈퍼캐패시터용 수산화 구리 전극)

  • Patil, U.M.;Nam, Min Sik;Shinde, N.M.;Jun, Seong Chan
    • KEPCO Journal on Electric Power and Energy
    • /
    • v.1 no.1
    • /
    • pp.175-180
    • /
    • 2015
  • A facile soft chemical synthesis route is used to grow nano-buds of copper hydroxide [$Cu(OH)_2$] thin films on stainless steel substrate[SS]. Besides different chemical methods for synthesis of $Cu(OH)_2$ nanostructure, the chemical bath deposition (CBD) is attractive for its simplicity and environment friendly condition. The structural, morphological, and electro-chemical properties of $Cu(OH)_2$ thin films are studied by means of X-ray diffraction (XRD), X-ray photoelectron spectroscopy (XPS), field emission scanning electron microscopy (FESEM), cyclic voltammetry (CV) and galvanostatic charge-discharge (GCD) measurement techniques. The results showed that, facile chemical synthesis route allows to form the polycrystalline, granular nano-buds of $Cu(OH)_2$ thin films. The electrochemical properties of $Cu(OH)_2$ thin films are studied in an aqueous 1 M KOH electrolyte using cyclic voltammetry. The sample exhibited supercapacitive behavior with $340Fg^{-1}$ specific capacitance. Moreover, electrochemical capacitive measurements of $Cu(OH)_2/SS$ electrode exhibit a high specific energy and power density about ${\sim}83Wh\;kg^{-1}$ and ${\sim}3.1kW\;kg^{-1}$, respectively, at $1mA\;cm^{-2}$ current density. The superior electrochemical properties of copper hydroxide ($Cu(OH)_2/SS$) electrode with nano-buds like structure mutually improves pseudocapacitive performance. This work evokes scalable chemical synthesis with the enhanced supercapacitive performance of $Cu(OH)_2/SS$ electrode in energy storage devices.

Technology of Organic Thin-Film Transistors for Active-Matrix Display

  • Lee, Cheng-Chung
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2004.08a
    • /
    • pp.877-880
    • /
    • 2004
  • A method of improving device performance of OTFT was investigated. The mobility of device is more than 0.51 $cm^2$/Vs and $I_{on}/I_{off}$ is higher than $10^6$. An Active-matrix LCD driven by OTFT was fabricated. The resolution of this panel is 64 ${\times}$ 128 pixels and the pixel size is 550 ${\mu}m$ ${\times}$ 550 ${\mu}m$.

  • PDF

Design and Operational characteristics of a Heat Pipe Heat Sink for Cooling of Power Semiconductors (전력변환 반도체용 히트파이프식 냉각기의 설계와 작동특성)

  • 강환국;김철수
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.6 no.6
    • /
    • pp.572-581
    • /
    • 2001
  • A heat pipe heat sink device which is to evacuate maximum heat of about 1800W from a powersemiconductor was designed and manufactured One set of cooling device os composed of an Aluminum block (130${\times}$160${\times}$35mm) 4 PFC heat pipes $(d_0 22.23mm)$ and 126 Aluminium fins (250${\times}$58${\times}$0.8mm) Experimental data obtained at a power of 1~2kW revealed that the total thermal resistance of the device varied 0.02~0.018$^{\circ}C$/W along with increasing air velocity from 2m/s to 3 m/s. The result represented a good satisfaction of requirement condition to maintain temperature rise of semiconductor lowe that $40^{\circ}C$ at 1800W and air velocity of 3 m/s Some important resistance such as convective resistances at both fins and heat pipes showed good agreement between mathematical predictions and measurement data.

  • PDF

Characteristics of AlGaAs/GaAs Quantum-Well Delta-Doped Channel FET's by Low Pressure Metalorganic Chemical Vapor Deposition (저압 유기금속기상 성장법에 의한 AlGaAs/GaAs 양자 우물에 델타 도우핑된 채널 FET 특성)

  • 장경식;정동호;이정수;정윤하
    • Journal of the Korean Institute of Telematics and Electronics A
    • /
    • v.29A no.4
    • /
    • pp.33-37
    • /
    • 1992
  • AlGaAs/GaAs quantum well delta-doped channel FET's have been successfully fabricated using by low-pressure metalorganic chemical vapor deposition(LP-MOCVD). The FET's with a gate dimension of 1.8$\mu$m $\times$ 100$\mu$m have a maximum transconductance of 190 mS/mm and a maximum current density of 425 mA/nm. The devices show extremely broad transconductances with a large voltage swing of 2.4V. The S-parameter measurements have indicated that the current gain and power gain cutoff frequencies of the device were 7 and 15 GHz, respectively. These values are among the best performance reported for GaAs based heterojunction FET's with a similar device geometry.

  • PDF

Design and Function Analysis of Dust Measurement Platform based on IoT protocol (사물인터넷 프로토콜 기반의 미세먼지 측정 플랫폼 설계와 기능해석)

  • Cho, Youngchan;Kim, Jeongho
    • Journal of Platform Technology
    • /
    • v.9 no.4
    • /
    • pp.79-89
    • /
    • 2021
  • In this paper, the fine dust (PM10) and ultrafine dust (PM2.5) measurement platforms are designed to be mobile and fixed using oneM2M, the international standard for IoT. The fine dust measurement platform is composed and designed with a fine dust measurement device, agent, oneM2M platform, oneM2M IPE, and monitoring system. The main difference between mobile and fixed is that the mobile uses the MQTT protocol for interconnection between devices and services without blind spots based on LTE connection, and the fixed uses the LoRaWAN protocol with low power and wide communication range. Not only fine dust, but also temperature, humidity, atmospheric pressure, volatile organic compounds (VOC), carbon monoxide (CO), sulfur dioxide (SO2), nitrogen dioxide (NO2), and noise data related to daily life were collected. The collected sensor values were managed using the common API provided by oneM2M through the agent and oneM2M IPE, and it was designed into four resource types: AE and container. Six functions of operability, flexibility, convenience, safety, reusability, and scalability were analyzed through the fine dust measurement platform design.

Dosimetric Evaluation of a Small Intraoral X-ray Tube for Dental Imaging (치과용 초소형 X-선 튜브의 선량평가)

  • Ji, Yunseo;Kim, YeonWoo;Lee, Rena
    • Progress in Medical Physics
    • /
    • v.26 no.3
    • /
    • pp.160-167
    • /
    • 2015
  • Radiation exposure from medical diagnostic imaging procedures to patients is one of the most significant interests in diagnostic x-ray system. A miniature x-ray intraoral tube was developed for the first time in the world which can be inserted into the mouth for imaging. Dose evaluation should be carried out in order to utilize such an imaging device for clinical use. In this study, dose evaluation of the new x-ray unit was performed by 1) using a custom made in vivo Pig phantom, 2) determining exposure condition for the clinical use, and 3) measuring patient dose of the new system. On the basis of DRLs (Diagnostic Reference Level) recommended by KDFA (Korea Food & Drug Administration), the ESD (Entrance Skin Dose) and DAP (Dose Area Product) measurements for the new x-ray imaging device were designed and measured. The maximum voltage and current of the x-ray tubes used in this study were 55 kVp, and 300 mA. The active area of the detector was $72{\times}72mm$ with pixel size of $48{\mu}m$. To obtain the operating condition of the new system, pig jaw phantom images showing major tooth-associated tissues, such as clown, pulp cavity were acquired at 1 frame/sec. Changing the beam currents 20 to $80{\mu}A$, x-ray images of 50 frames were obtained for one beam current with optimum x-ray exposure setting. Pig jaw phantom images were acquired from two commercial x-ray imaging units and compared to the new x-ray device: CS 2100, Carestream Dental LLC and EXARO, HIOSSEN, Inc. Their exposure conditions were 60 kV, 7 mA, and 60 kV, 2 mA, respectively. Comparing the new x-ray device and conventional x-ray imaging units, images of the new x-ray device around teeth and their neighboring tissues turn out to be better in spite of its small x-ray field size. ESD of the new x-ray device was measured 1.369 mGy on the beam condition for the best image quality, 0.051 mAs, which is much less than DRLs recommended by IAEA (International Atomic Energy Agency) and KDFA, both. Its dose distribution in the x-ray field size was observed to be uniform with standard deviation of 5~10 %. DAP of the new x-ray device was $82.4mGy*cm^2$ less than DRL established by KDFA even though its x-ray field size was small. This study shows that the new x-ray imaging device offers better in image quality and lower radiation dose compared to the conventional intraoral units. In additions, methods and know-how for studies in x-ray features could be accumulated from this work.

IoT Device Management Standard Protocol Trends in Mobile Communications (이동통신 기반 IoT 장치관리 표준 프로토콜 동향)

  • Oh, S.H.;Ko, S.K.;Son, S.C.;Lee, B.T.;Kim, Y.S.
    • Electronics and Telecommunications Trends
    • /
    • v.30 no.1
    • /
    • pp.94-101
    • /
    • 2015
  • 이동통신 기반 IoT(Internet of Things) 관련 표준들은 3GPP와 ETSI를 중심으로 제정되어 왔으나 2012년부터 표준의 중복을 회피하고 단일화된 표준을 통해서 IoT 시장을 성장시키고자 oneM2M이라는 국제적 협의체가 구성되었으며, 최근 Release 1 표준을 발표하는 등 IoT 표준을 사실상 주도하고 있다. Mason과 Machina 리서치에 따르면 2020년에는 동시 연결된 M2M(Machine to Machine)/IoT 장치들의 수가 21억개에 달할 것이고, 이것들이 동시에 200억개의 통신 연결을 생성할 것이다. 이런 수많은 장치들을 관리하기 위한 표준으로 OMA(Open Mobile Alliance)에서는 LWM2M(Lightweight M2M)를 제정하였다. 또한 이런 장치들은 센서들과 같이 연산능력과 배터리에 제약이 많아서 이것을 극복할 수 있는 메시지 프로토콜로 IETF에서는 CoAP 표준을 제정하였다. oneM2M에서도 CoAP과 LWM2M 표준을 채택하였고, 이를 기반으로 한 단말과 응용서비스 관리 기능이 확대될 것으로 기대된다. 본고에서는 이동통신 기반 IoT 표준 동향과 LWM2M 기반 단말 관리 규격에 대해 살펴본다.

  • PDF