• Title/Summary/Keyword: M-pass

Search Result 738, Processing Time 0.031 seconds

Development of a Pre-treating Equipment and the Carcass Disposal System for Infected Poultry (감염가금 전처리 및 폐사가축 처리시스템 개발)

  • Hong, J.T.;Kim, H.J.;Yu, B.K.;Lee, S.H.;Hyun, C.S.;Ryu, I.S.;Oh, K.Y.;Kim, S.;Kwon, J.H.;Tack, D.S.
    • Journal of Animal Environmental Science
    • /
    • v.17 no.2
    • /
    • pp.81-92
    • /
    • 2011
  • When we bury the infected poultry into the ground, we have many problems such as the difficulty of making sufficient area for burying, environmental contamination by the leachate, unpleasant ordor. Also, in case of burning the carcass of the infected poultry, there are some problems such as high cost, dust, unpleasant odor, etc. It could cause environmental contamination which many peoples and environmental organization complains about. In this study, we develop a treating system which treats the infected poultry carcass in a environmental method preventing the environment contamination. This system is composed of many processes. The euthanasia system uses rigid vinyl to trap and to do a euthanasia the infected poultry with lethal gas, carbon dioxide. And then, with the tractor attached grappler infected poultry carcass could be put into the carcass treating system. The euthanasia system uses rigid vinyl to trap the infected birds and to confine lethal gas, carbon dioxide. Infected poultry carcass are moved to carcass disposal system by collecting device which is attached at tractor. The carcass treatment system (capacity of disposal : 6.3 $m^3$) is installed on a truck and do one pass work, which is input, crush, stir, sterilize, and discharge treated carcass. 1,000 chickens was killed within 9.7min by $CO_2$ (300L/min) in the tent (10 $m^3$). The collecting device could carry 142 chickens at a time, and the movable carcass treatment system could sterilize 2 tons carcass per hour (at one time). This treatment systems was eco-friendly because it reduced the volume of carcass by 31.9% with no wastewater generation.

Histomorphological Comparison of the Coronary Artery and Available Graft Conduits (관상동맥 및 이식편으로 사용 가능한 혈관들의 조직형태학적 비교)

  • Kim, Yong-Ho;Lee, Seok-Ki;Yu, Jeong-Hwan;Kim, Si-Wook;Kang, Shin-Kwang;Lim, Seung-Pyung;Yu, Jae-Hyeon;Lee, Young
    • Journal of Chest Surgery
    • /
    • v.41 no.5
    • /
    • pp.563-567
    • /
    • 2008
  • Background: The histomorphological properties of the left anterior desecending artery (LAD), the left internal thoracic arteries (LITA), the radial arteries (RA) and the intercostal arteries (ICA) were studied for their use as a conduit for coronary artery bypass grafting (CABG), and we compared them with each other. Material and Method: All the vessels were harvested from nineteen cadavers (17 males and 2 females). The mid-portion of the LAD, the mid-portion of the LITA, the distal RA and the mid-portion of the 5th ICA were obtained. All of them were stained with hematoxylin-eosin and with Van Gieson's elastin stain. The morphological characteristics were examined and the thicknesses of the intima and media (I/M ratio: the intima to media ratio) were compared using one-way ANOVA tests. Result: The mean age of the cadavers was $61.5{\pm}9.6$ years. The LITA and ICA were elastic arteries, and the LAD and RA were muscular arteries. The I/M ratio showed statistically significant differences: $0.07{\pm}0.03$ in the LITA, $0.16{\pm}0.11$ in the ICA, $0.45{\pm}0.29$ in the RA and $0.93{\pm}0.52$ in the LAD, respectively. Conclusion: This study showed that the degrees of intimal hyperplasia of the CA and the various conduits for CABG were different significantly. The ICA was found to have relatively favorable characteristics as a coronary by pass conduit, but its suitability for clinical use is a challenging issue.

A Study on Under Keel Clearance of Gadeok Channel for the Safety Passage of Mega Container Ship (초대형 컨테이너선의 가덕수로 안전운항을 위한 선저여유수심 연구)

  • Ryu, Won;Kong, Suk-Young;Lee, Yun-Sok
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.27 no.6
    • /
    • pp.789-797
    • /
    • 2021
  • The worldwide sizes of container ships are rapidly increasing. The container ship size in 2005, which was about 9,200 TEU has increased to 24,000 TEU in recent times. In addition to the increase in the sizes of the container ships, the arrivals/departures of large container vessels to/from Korea have also increased. Hence, the necessity for reviewing safe passage of such vessels is emphasized. In the present study, a 24,000 TEU container vessel was used as a model ship to calculate the under-keel clearance (UKC) at Gadeok Channel through which vessels must pass to arrive at Busan New Port, in accordance with the Korean Port and Fishing Port Design Standards and Commentary. In addition, the maximum allowable speed that meets UKC standards was calculated using various squat formulas, whose results were then compared with the current speed limit standards. The analysis results show that Busan New Port requires 10% marginal water depth, and the squat that meets this requirement is 0.95 m. Gadeok Channel requires 15% marginal water depth, and the squat that meets this requirement is 1.78 m; in this case, the maximum allowable speed is calculated as 15 kts. Busan New Port has set the speed limit as 12 kts, which is higher than the calculated 11 kts. Thus, speed limit reconsideration is required in terms of safety. However, the set speed limit for Gadeok Channel is 12 kts, which is lower than the calculated 15 kts. Thus, additional considerations may be provided to increase the speed limits for smooth navigational passage of vessels. The present study, however, is constrained by the fact that it reflects only a limited number of elements in the UKC and allowable speed calculations; therefore, more accurate UKC and safe speed values can be suggested based on extended studies to this research.

Development of Local Animal BLAST Search System Using Bioinformatics Tools (생물정보시스템을 이용한 Local Animal BLAST Search System 구축)

  • Kim, Byeong-Woo;Lee, Geun-Woo;Kim, Hyo-Seon;No, Seung-Hui;Lee, Yun-Ho;Kim, Si-Dong;Jeon, Jin-Tae;Lee, Ji-Ung;Jo, Yong-Min;Jeong, Il-Jeong;Lee, Jeong-Gyu
    • Bioinformatics and Biosystems
    • /
    • v.1 no.2
    • /
    • pp.99-102
    • /
    • 2006
  • The Basic Local Alignment Search Tool (BLAST) is one of the most established software in bioinformatics research and it compares a query sequence against the libraries of known sequences in order to investigate sequence similarity. Expressed Sequence Tags (ESTs) are single-pass sequence reads from mRNA (or cDNA) and represent the expression for a given cDNA library and the snapshot of genes expressed in a given tissue and/or at a given developmental stage. Therefore, ESTs can be very valuable information for functional genomics and bioinformatics researches. Although major bio database (DB) websites including NCBI are providing BLAST services and EST data, local DB and search system is demanding for better performance and security issue. Here we present animal EST DBs and local BLAST search system. The animal ESTs DB in NCBI Genbank were divided by animal species using the Perl script we developed. and we also built the new extended DB search systems fur the new data (Local Animal BLAST Search System: http://bioinfo.kohost.net), which was constructed on the high-capacity PC Cluster system fur the best performance. The new local DB contains 650,046 sequences for Bos taurus(cattle), 368,120 sequences for Sus scrofa (pig), 693,005 sequences for Gallus gallus (fowl), respectively.

  • PDF

Gastrointestinal Foreign Bodies in Children -Experiences of 60 Cases in Kangwon, Korea- (소아 위장관 이물 -강원지역 소아 60례-)

  • Lee, Young-Sub;Kang, Kae-Wool;Choi, Won-Kyu
    • Pediatric Gastroenterology, Hepatology & Nutrition
    • /
    • v.4 no.2
    • /
    • pp.148-154
    • /
    • 2001
  • Purpose: Ingested foreign bodies present a common clinical problem. It is well known that most of them pass uninterrupted through the gastrointestinal tract. We evaluated the role of endoscopy and Foley catheter for removal of foreign bodies in the gastrointestinal tract. Methods: We investigated retrospectively 60 cases with foreign bodies in the gastrointestinal tract. They had been treated at Wonju Christian Hospital, Yonsei University of Korea, from January, 1996 through December, 1999. Results: The age of the patients ranged from 7 months to 13 years. Patients under 5 years were 57 cases (97%) and there was no significant difference in sex (M : F=1.07 : 1). 45 cases of the patients had no symptom. The most common foreign bodies were coins (43 cases). The most common location was esophagus (31 cases). The number of foreign body removal using flexible endoscopy and Foley catheter was 22 (36.7%) and 18 (30.0%) cases, respectively. In 18 cases (30.0%), foreign bodies passed spontaneously. Only 1 case (1.7%), curtain pin impaction at ileocecal region, required surgery. Conclusion: Early foreign body removal from esophagus and stomach is recommended to lessen the morbidity and complication. Fluoroscopic foley catheter technique and flexible endoscopy for removal of esophageal foreign bodies in children is safe and effective.

  • PDF

Effect of Feeding Bypass Protein with Urea Treated Grass on the Performance of Red Kandhari Calves

  • Wankhede, S.M.;Kalbande, V.H.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.14 no.7
    • /
    • pp.970-973
    • /
    • 2001
  • An experiment was carried out to assess the effect of feeding concentrate mixtures varying in bypass protein levels with urea-treated or untreated grass on the performance of twelve Red Kandhari calves (14 months of age and 78.15 kg body weight) for a period of 75 days. Dry grass was treated with 4 percent urea solution and ensiled for 30 days. The CP ($N{\times}6.25$) content in urea treated grass increased from 3.96 to 8.89 percent. Two iso-caloric and iso-nitrogenous concentrate mixtures (CM-I and CM-II) varying in RDP to UDP ratio viz., 65:35 and 55.45 were prepared. The calves in control group ($T_1$) were fed concentrate mixture-I with ad libitum untreated dry grass and those in experimental group ($T_2$) were fed concentrate mixture-II with ad libitum urea treated dry grass. The dry matter consumption in group $T_2$ was significantly (p<0.01) higher as compared to group $T_1$. The total DMI in $T_1$ and $T_2$ was 146.92 and 166.95 kg respectively, whereas the DMI per day and per 100 kg body weight was 1.94 and 2.22 and 1.90 and 2.35 kg, respectively. The average total gain in body weight (kg) and average daily gain (g) of calves in $T_2$ was significantly (p<0.01) higher as compared to those in $T_1$ the values being 28.66, 18.33 and 382.16, 244.44, respectively. Feed efficiency in terms of kg DM per kg gain in body weight was significantly (p<0.01) lower in group $T_1$ than in $T_2$. The cost of feed per kg gain in body weight for $T_2$ and $T_1$ group was Rs. 21.14, 28.22, respectively. The digestibility coefficients of DM, CP, EE, CF, NFE, NDF and ADF were 59.60, 57.50, 53.00, 65.04, 45.82, 48.48, 52.48 and 55.73 for $T_1$ group. The coressponding values were 68.78, 67.80, 59.83, 71.41, 49.93, 53.37 and 57.81, respectively for $T_2$ group. The digestibility coefficients for all the proximate principles in $T_2$ were significantly (p<0.01) higher as compared to $T_1$. However, NDF and ADF digestibilities were not significantly different. Nutritive value determined in terms of DCP and TDN for The experimental ration was significantly (p<0.01) higher than control ration, the values being 7.32 and 47.34 and 9.39 and 52.40% respectively. The blood urea nitrogen levels at 0, 3 and 6 h interval after feeding were significantly (p<0.01) lower in calves fed experiment ration as compared to control. The overall results indicated that in Red Kandhari calves an optimum growth can be economically achieved by feeding 4 percent urea treated dry and mature grass as basal roughage supplemented with a concentrate mixture containing 20 percent CP, 70% TDN and 45% UDP/bypass protein.

Monitoring of a Steel Plate Girder Railroad Bridge with Fiber Bragg Grating Sensors (광섬유 격자센서를 이용한 철도 판형교의 증속 실험)

  • Chung, Won Seok;Kang, Dong Hoon;Choi, Eun Soo;Kim, Hyun Min
    • Journal of Korean Society of Steel Construction
    • /
    • v.17 no.6 s.79
    • /
    • pp.681-688
    • /
    • 2005
  • This study investigates an existing steel plate girder railroad bridge after superstructure rehabilitation to monitor static and dynamic responses using Fiber Bragg Grating (FBG) sensors. This paper also presents an experimental technique to estimate the vertical deflection of the bridge using FBG sensors. Seven FBG sensors are multiplexed in a single optical fiber and installed in parallel pairs along the length of the bridge, with one set at the top flange and the other at the bottom flange. In addition to FBG sensors, a conventional electric strain gauge and anLVDT are installed at the mid-span of the bridge for comparison. A test train consisting of one locomotive is placed at the center of the bridge to produce the maximum static effect. The train is also made to pass over the bridge at different speeds ranging from 10 km/h to 90 km/h to monitor the dynamic response of the bridge. This study demonstrates that the measured strains using the FBG sensor compared well with the readings from the electric strain gauge. The results show that the proposed instrumentation technique is capable of estimating the vertical deflection of the bridge for various loading conditions, which is crucial in structural health monitoring. Several dynamic characteristics of the bridge were also identified.

Understanding on MR Perfusion Imaging Using First Pass Technique in Moyamoya Diseases (Moyamoya 질환에서 1차 통과기법을 이용한 자기공명관류영상의 이해)

  • Ryu, Young-Hwan;Goo, Eun-Hoe;Jung, Jae-Eun;Dong, Kyung-Rae;Choi, Sung-Hyun;Lee, Jae-Seung
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.12 no.1
    • /
    • pp.27-31
    • /
    • 2010
  • The purpose of this study was to investigated the usefulness of MR perfusion image comparing with SPECT image. A total of pediatric 30 patients(average age : 7.8) with Moyamoya disease were performed MR Perfusion with 32 channel body coil at 3T from March 01, 2010 to June 10, 2010. The MRI sequences and parameters were as followed : gradient Echo-planar imaging(EPI), TR/TE : 2000ms/50ms, FA : $90^{\circ}$, FOV : $240{\times}240$, Matrix : $128{\times}128$, Thickness : 5mm, Gap : 1.5mm. Images were obtained contrast agent administrated at a rate of 1mL/sec after scan start 10s with a total of slice 1000 images(50 phase/1 slice). It was measured with visual color image and digitize data using MRDx software(IDL version 6.2) and also, it was compared of measurement with values of normal and abnormal ratio to analyze hemodynamic change, and a comparison between perfusion MR with technique using Warm Color at SPECT examination. On MR perfusion examination, the color images from abnormal region to the red collar with rCBV(relative cerebral blood volume) and rCBF(relative cerebral blood flow) caused by increase cerebral blood flow with brain vascular occlusion in surrounding collateral circulation advancement, the blood speed relatively was depicted slowly with blue in MTT(Mean Transit Time) and TTP(Time to Peak) images. The region which was visible abnormally from MR perfusion examination visually were detected as comparison with the same SPECT examination region, would be able to confirm the identical results in MMD(Moyamoya disease)judgments. Hymo-dynamic change in MR perfusion examination produced by increase and delay cerebral blood flow. This change with digitize data and being color imaging makes enable to distinguish between normal and abnormal area. Relatively, MR perfusion examination compared with SPECT examination could bring an excellent image with spatial resolution without radiation expose.

  • PDF

The Promotive Effects of Antioxidative Apigenin on the Bioavailability of Paclitaxel for Oral Delivery in Rats

  • Choi, Sang-Joon;Choi, Jun-Shik
    • Biomolecules & Therapeutics
    • /
    • v.18 no.4
    • /
    • pp.469-476
    • /
    • 2010
  • This study was to investigate the effect of apigenin on the bioavailability of paclitaxel after oral and intravenous administration in rats. The effect of apigenin on P-glycoprotein (P-gp), cytochrome P450 (CYP)3A4 activity was evaluated. The pharmacokinetic parameters of paclitaxel were determined in rats after oral (40 mg/kg) or intravenous (5 mg/kg) administration of paclitaxel with apigenin (0.4, 2 and 8 mg/kg) to rats. Apigenin inhibited CYP3A4 activity with 50% inhibition concentration ($IC_{50}$) of 1.8 ${\mu}M$. In addition, apigenin significantly inhibited P-gp activity. Compared to the control group, apigenin significantly increased the area under the plasma concentration-time curve (AUC, p<0.05 by 2 mg/kg, 59.0% higher; p<0.01 by 8 mg/kg, 87% higher) of oral paclitaxel. Apigenin also significantly (p<0.05 by 2 mg/kg, 37.2% higher; p<0.01 by 8 mg/kg, 59.3% higher) increased the peak plasma concentration ($C_{max}$) of oral paclitaxel. Apigenin significantly increased the terminal half-life ($t_{1/2}$, p<0.05 by 8 mg/kg, 34.5%) of oral paclitaxel. Consequently, the absolute bioavailability (A.B.) of paclitaxel was significantly (p<0.05 by 2 mg/kg, p<0.01 by 8 mg/kg) increased by apigenin compared to that in the control group, and the relative bioavailability (R.B.) of oral paclitaxel was increased by 1.14- to 1.87-fold. The pharmacokinetics of intravenous paclitaxel were not affected by the concurrent use of apigenin in contrast to the oral administration of paclitaxel. Accordingly, the enhanced oral bioavailability by apigenin may be mainly due to increased intestinal absorption caused via P-gp inhibition by apigenin rather than to reduced renal and hepatic elimination of paclitaxel. The increase in the oral bioavailability might be mainly attributed to enhanced absorption in the gastrointestinal tract via the inhibition of P-gp and reduced first-pass metabolism of paclitaxel via the inhibition of the CYP3A subfamily in the small intestine and/or in the liver by apigenin. It appears that the development of oral paclitaxel preparations as a combination therapy is possible, which will be more convenient than the i.v. dosage form.

The Next Wave in Display Innovation

  • Webster, Steven C.
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2008.10a
    • /
    • pp.4-4
    • /
    • 2008
  • The progress in flat panel displays over the last two decades has been astonishing. In just 20 years, the LCD-TV grew up from a 2-inch curiosity, to an industry that will sell about 120 million flat panel TV's this year, with viewing area up to 4000 times larger. That success is based on continuous innovation, especially in manufacturing processes. For the next decade to bring another doubling of the business, progress will need to continue in four major areas: Human factors, ecological impact, visual quality, and of course continued drive towards affordability. This talk will detail the technology advances that can allow this industry to meet those challenges. Human factors. Today, we adapt our lifestyle to our technology. People organize their offices, and their homes, around displays. We pass around mobile phones to share images, rather than experiencing them as a group. Billions of newspapers continue to be sold daily. Advances in flexible displays can lead to large portable displays. "New era projection" includes the handheld Pico Projectors that are already on the market, and will ultimately appear integrated in mobile phones the same way cameras do today. "Eco" impact. Today TV's are one of the top energy consumers in a U.S. home, and the fastest growing. Watching a large flat panel TV can cost twice as much as running a large refrigerator. With today's concern about energy consumption, regulations are starting to emerge worldwide to limit TV electrical use. Fortunately, good solutions exist in using light management films to eliminate bulbs, saving power without increasing cost. Going forward, LED backlights will drive another step downward. OLED displays might be the ultimate solution. Visual quality. The color of an LCD-TV is still often considered inferior to a far less expensive CRT. And almost all displays suffer from representing a three-dimensional world on a two dimensional surface. The technology to improve color is available today, and will likely move from premium sets into the mainstream as costs come down. 3D is now arriving in movie theaters worldwide, and that will drive up the demand for similar realistic images in home theaters. And the technology is emerging today for 3D representation to move beyond specialized applications into everyday use, on screens large and small. Affordability. The world takes cost-down miracles for granted in consumer electronics. Each of these other advances will be balanced with a drive for affordability, especially as the market grows in emerging countries. The other three challenges must be met without increasing cost. Putting this all together, the next few years will emphasize "eco friendly" designs, and enhanced images such as 3D. By 2013 we will start to see serious penetration by emissive technologies (OLED, high efficiency plasma, or other), with the "ultimate display" likely not in the market for a decade. Lots of opportunities for innovation remain ahead of us.

  • PDF