• 제목/요약/키워드: M&S system

검색결과 10,161건 처리시간 0.047초

Triclinic과 Monoclinic Systems에 속한 Space Groups의 유도 (The Derivation of the Space Groups in Triclinic and Monoclinic Systems)

  • 김인회;강상욱;김문집;서일환
    • 한국결정학회지
    • /
    • 제13권2호
    • /
    • pp.73-81
    • /
    • 2002
  • Triclinic system에는 2개의 point group들 1,(equation omitted), 그리고 monoclinic system에는 3개의 point groups, 2, m, 2/m 가 있는데/sup 1)/ point group들 1, 2, m은 polar point group이고 이 중의 1, 2는 enantiomorphous point group이며 point group들 (equation omitted)와 2/m은 centric point group으로 Laue group이라 일컬어진다./sup 2-4)/ 본 해설문에서는 point group들 1, (equation omitted)에서 나오는 2개의 space group들과 point group들 2, m, 2/m에서 유도되는 13개의 space group들의 좌표들을 유도하였다 . Monoclinic system에서는 unique axis b 만을 다루었고, 그리고 space group No. 14은 3가지로 해석하였으며 나머지는 standard space group만을 다루었다. 모든 space group diagram은 “International Tables for Crystallography, Volume A edited by Theo Hahn, Third revised edition published for The International Union of Crystallography by Kluwer Academic Publishers, 1992”에 기재되어 있다.

군 탐색구조 시스템 M&S 소프트웨어 개발 현황 (Development Status of Military Search and Rescue System M&S Software)

  • 김재현;이상욱;김재훈;안우근
    • 한국위성정보통신학회논문지
    • /
    • 제9권3호
    • /
    • pp.121-126
    • /
    • 2014
  • 한국전자통신연구원에서는 2010년 하반기부터 방위사업청과 국방과학연구소에서 주관하는 국방위성항법 특화연구센터 사업에 참가하여 군 탐색구조 시스템 기술연구 과제를 수행 중에 있다. 1차년도에 기존 군 탐색구조 개념과 민간 탐색구조 시스템에 대하여 분석한 결과를 토대로 M&S(Modeling and Simulation)를 수행하여, 군 탐색구조 시스템 구성시 탐색구조의 정확성, 신뢰성, 가용성을 향상시킬 수 있는 방안을 분석할 수 있는 툴을 목표로 개발하였다. 이를 위하여 군 탐색구조 시스템을 크게 사용자, 통신링크, 지상국, 운용환경 분야로 나누어 모델링 하였으며, 실제와 유사한 성능분석을 위하여 GIS 고도정보를 이용하여 사용자와 지상국 안테나 간의 Path Profile을 분석한 후 신호감쇄량을 결정한다. 여기서 사용자의 단말기 송출신호를 송수신하는 링크는 크게 지상망과 위성망으로 나누어 모델링하여 시뮬레이션하고, 근래에 북한의 재밍 사태에 따라 이슈가 되고 있는 재밍 항목을 추가하였다. 본 논문에서는 군 탐색구조 시스템 M&S 소프트웨어를 소개하고, 소프트웨어 설계와 기능 및 성능분석 결과를 나타낸다.

액체 추진제 공급 시스템의 모델링 및 시뮬레이션 연구 동향 분석 (Research Trend Analysis on Modeling and Simulation of Liquid Propellant Supply System)

  • 이주연;차승원;하동휘;기원근;이재청;허환일;노태성;이형진
    • 한국추진공학회지
    • /
    • 제23권6호
    • /
    • pp.39-50
    • /
    • 2019
  • 액체 추진제 공급 시스템에 대한 Modeling and Simulation(M&S)는 엔진의 각 구성품을 수학적으로 모델링하여 특정 조건에서의 성능을 예측하는 기법이다. 본 논문에서는 국내외에서 수행된 관련 연구를 분석하여 액체 로켓엔진에 적용되는 공급 시스템에 대한 M&S의 기본 구성을 파악하였다. 구성요소의 보편적인 수학적 모델링을 정리하고 각 연구 결과에 대한 특징을 분석하였다. 또한 해석 및 검증 결과를 바탕으로 선진 해외 연구 기관의 M&S 수준을 확인하였고, M&S 기법의 정확도와 관련한 요인을 기술하였다.

WEAKLY LARGE SUBSYSTEMS OF S-SYSTEM

  • Kim, Jupil;Kim, Sungjin
    • 충청수학회지
    • /
    • 제20권4호
    • /
    • pp.485-493
    • /
    • 2007
  • The purpose of this paper is to introduce and investigate the weakly large subsystem of S-system $M_S$. In this study, we consider injective algebraic system and large subsystem. We also characterize weakly nonsingular congruence on S-system.

  • PDF

건기 및 우기 때의 WHAT system과 유량측정에 의한 기저유출량 비교 (Baseflow Comparison using the WHAT system and Flow Rate Measurements in the Dry and Rainy Seasons)

  • 남경훈;김규범;정교철
    • 지질공학
    • /
    • 제23권2호
    • /
    • pp.117-125
    • /
    • 2013
  • 강우패턴의 변화에 의한 대하천변 지하수홍수발생은 농 경작지에서 큰 문제로 대두되고 있다. 따라서 대하천변의 지하수홍수 발생 메커니즘을 규명하기 위한 하천의 유량을 결정하는 가장 중요한 요소인 직접유출량과 기저유출량의 정량적인 해석이 필요하다. 이 연구에서는 수변구역에서 WHAT system이라는 Web GIS 기반의 수문분석 방법을 이용하여 산출된 기저유출량과 실제 하천에서 산출된 기저유출량을 정량적으로 비교분석 하였다. 연구지역의 기저유출량은 우기인 2012년 07월 17일에는 0.489 $m^3/s$, 2012년 07월 18일에는 0.260 $m^3/s$, 2012년 07월 19일에는 0.279 $m^3/s$이었고 건기였던 2013년 03월 06일에는 0.006 $m^3/s$, 2013년 03월 30일에는 0.009 $m^3/s$의 기저유출량이 산출되었다. 분석결과 수변구역 충적층 지역에서 강우 발생 시 기저유출량의 증가가 발생하였으며 건기 시 오차가 다소 적게 나타났다.

M&S 시스템을 활용한 Tac-ELINT 지상운용 SW 개발 방안 연구 (A Research on Tac-ELINT SW Development Method Using M&S System)

  • 신동조;곽현규;이광일
    • 한국군사과학기술학회지
    • /
    • 제14권6호
    • /
    • pp.1058-1066
    • /
    • 2011
  • This research paper on Tac-ELINT SW development method using M&S system describes the validation and verification methods of Tac-ELINT ground operating software development each stages, and the method of improving reusability of software using SBD(Simulation Based Design/Development) concept. In this project, We obtain the EW software SBD technologies and improved Tac-ELINT ground operating software through software crisis mitigation. This method and technology will expect to support a future EW system and any other various weapon software development.

765kV 변전소 시운전에 관한 고찰 (Consideration on the trial operation of 765kV substation)

  • 변강;정시환;박근원;이상면;최만식
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 추계학술대회 논문집 전력기술부문
    • /
    • pp.29-31
    • /
    • 2002
  • Purpose of the 765kV trial operation conducted for the first time in our country are performance verification of domestic developed equipment(765kV M.Tr, GIS,etc) and extraction of problem in advance to commercial operation and cultivation of operation ability. The trial operation of 765kV substation was finished successfully under the positive supports of institutes. manufactures. and constructers. It is expected that extraction of problems in advance and accumulation of operation techniques through the trial operation of 765kV substation will be contributed largly to the realization of the without a hitch operation of 765kV system.

  • PDF

지하수 유로 조사를 위한 절리계의 응용지질학적 분석 (A Study of Joint System for Groundwater Pathway)

  • 최병렬
    • 지질공학
    • /
    • 제8권2호
    • /
    • pp.131-143
    • /
    • 1998
  • 본 연구는 충청남도 논산군 벌곡면 일대 즉 벌곡면 도산리와 수락리에 발달한 지하수 충진지역을 대상으로 하였다. 조사 지역의 수계는 남북 방향으로 발달되어 있으며, 지질은 가장 고기에 해당하는 옥천계 창리층(Och)이 중앙부에 위치하며, 본 지역의 서쪽의 경상계 유천층군에 대비되는 응회암(Kslt)은 동쪽의 화강암(Kqb)과 북쪽의 석영반암(Kgf)에 의하여 관입 되었다. 각 지역에서 측정된 약 3000개의 절리면을 경사 방향과 각도를 구면투영하여 통계학적으로 우세한 방향을 찾아본 결과 화강암의 경우는 dipdirection/dip이 228~257/73~88, 010~150/70~85 두방향이, 창리층의 경우는 134~164/40~90, 214~249/55~89, 응회암은 291~332/75~82, 235~241/73~71의 방향이 우세하였다. 그러나 북부에 소규모로 분포하는 석영반암은 뚜렷한 방향성을 나타내지 않았다. 기반암에서의 P파 전달속도를 측정하여 최대치와 최소치를 비교한 결과 석영반암은 $5000(240)~2380(360^{\circ})m/s$로, 화강암은 $3846(210^{\circ})~1408(150^{\circ})m/s$ 응회암은 $5000(360^{\circ})~2323(150^{\circ})m/s$, 창리층 지역에서는 $6667(180^{\circ})~2000(030^{\circ})m/s$로 나타났다. 암석의 공학적 성질은 시료를 26면체의 시편으로 제작한후 각 방향별 동탄성계수 즉 뽀아송의 비, 강성률, 영률, 체적탄성률을 산출하여 야외에서 측정된 자료와 비교 분석 하였다.

  • PDF

M10CN 교환기의 집중과금처리방식 (CAMA) 구현 (Implementation of CAMA for M10cn switch)

  • 최윤수;김동훈;정성문;이명재
    • 전자공학회논문지S
    • /
    • 제35S권4호
    • /
    • pp.30-39
    • /
    • 1998
  • Currently, LAMA(Local Automatic Message Accounting) is a billing mechanism which is being used for billing process, in which billing dat is written on MT(Magnetic Tape), collected at each regional billing center and then processed once a month. However, in order to prepare further development of telecommunication network and future new services, computerization of billing process and new daily billing processing system are urgently needed. Therefore Korea Telecom had developed a CAMA (Centralized Automatic Message Accounting) system for M10CN switch. In the CAMA system, billing data generated in switches is transfered on-line using approproate protocols and various transmission media and immediately processed. The CAMA system for M10CN switch consists of three parts such as ED (Extraction Device), TD(Transmission Device) and HC(Host Collector). The system also has redundancy to maintain continuance and confidence of system operation.

  • PDF

Ebb and Flow 시스템을 이용한 호접란 수경재배시 생장에 미치는 배양액 농도의 영향 (Effect of Nutrient Solution Strength on Growth of Phalaenopsis in an Ebb and Flow System)

  • 안동춘;박선혜;빈철구;정병룡
    • 생물환경조절학회지
    • /
    • 제16권3호
    • /
    • pp.199-204
    • /
    • 2007
  • 배양액 농도가 호접란 미니다화성계 품종 P. amabilis와 P. Taisuco Red Jewel의 유묘와 중간묘의 생장에 미치는 영향을 알아보기 위해 ebb and low system을 이용하여 4개월 재배한 결과는 다음과 같다. 유묘의 경우 엽장과 엽폭이 P. amabilis는 배양액의 EC가 $0.5{\sim}1.0dS{\cdot}m^{-1}$일 때 가장 길었으나 P. Taisuco Red Jewel 배양액의 EC가 $1.5dS{\cdot}m^{-1}$일 때 가장 길었다. 반면에 근장과 근중은 두 품종 모두 배양액의 EC가 $0.5dS{\cdot}m^{-1}$로 낮을 때 가장 무거웠고 이러한 경향은 중간묘에서도 동일하게 나타났다. 잎의 생체중과 건물중은 P. amabilis의 경우 배양액의 EC가 $1.5dS{\cdot}m^{-1}$로 높을 때 가장 무거웠으며, 배양액의 EC가 낮아질수록 잎의 생체중과 건물중은 낮아졌다. 반대로 뿌리의 생체중은 배양액 EC가 $0.5dS{\cdot}m^{-1}$로 낮을 때 가장 무거웠고, 배양액의 EC가 높아질수록 가벼워졌으며, P. Taisuco Red Jewel에서도 같은 경향이었다. 중간묘의 경우 뿌리의 생체중과 건물중이 P. amabilis는 배양액 EC가 $0.5dS{\cdot}m^{-1}$로 낮을 때 가장 높았고, 배양액의 EC가 높아질수록 뿌리의 생체중은 낮아졌다. T/R율과 잎의 엽록소함량은 유묘와 마찬가지로 두 품종 모두 배양액의 EC가 $1.5dS{\cdot}m^{-1}$로 높을 때 가장 높았으며, 배양액의 농도가 낮아질수록 낮아졌다.