The Study on the Effect of Elevator Movement on the Pressure Difference between Vestibule and Living room in High-rise Buildings (초고층 건축물에서 엘리베이터 구동이 부속실과 화재실 간 차압형성에 미치는 영향연구)

  • Park, Younggi;Hong, Kibea;Ryou, Hong Sun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.1
    • /
    • pp.85-91
    • /
    • 2018
  • Recently, there have been a lot of casualties due to fires in high-rise buildings. The toxic gases and smokes generated by fires in high-rise buildings spread rapidly through the elevator shaft and stairwell, due to the stack effect, and can cause critical casualties. To reduce the number of casualties, smoke control systems have been introduced. Smoke control systems play an essential role in preventing the spread of smoke in high-rise buildings and securing the evacuation route. Also, in high-rise buildings, evacuation by an elevator is considered to be indispensable. However, the pressure field in the shaft is strongly disturbed when the elevator is moving and this can affect the performance of the smoke control system. Therefore, in this study, we experimentally and numerically analyzed the effect of elevator movement on the pressure difference between the vestibule and living room by building a model using the sandwich pressurization method based on the performance based design. To consider the leakage areas in high-rise buildings, e.g. the windows, fire door and elevator, the National Fire Safety Codes and area ratio were used. The elevator speed in the model building was varied between 20 m/s and 100 m/s corresponding to a real elevator speed of 7 m/s~17 m/s. As a result, the relationship between the pressure difference and elevator speed was found to be ${\Delta}P=40{\cdot}{\exp}$(-Ves /-104.7)-23.735. This result can be used to take into consideration the effect of elevator movement when designing smoke control systems.

Effects of $Cu^{++}-Catalyzed$ Peroxidation on Collagen Gelation ($Cu^{++}-Catalyzed$ Peroxidation이 Collagen Gelation에 미치는 영향)

  • Chung, Myung-Hee;Kim, Myung-Suk;Lee, Chung-Soo
    • The Korean Journal of Pharmacology
    • /
    • v.19 no.2
    • /
    • pp.35-44
    • /
    • 1983
  • reactive oxygen species에 의해 나타나는 reactivity에 있어서 metal ions이 관여함이 시사되고 있다. 이미 알려진 reactive oxygen species와 metal ions의 상호작용 이외에 특히 $Cu^{++}$$H_2O_2$가 강력한 peroxidative action을 나타낸다는 사실이 알려져 있으며 $Cu^{++}-H_2O_2$가 biological system 에서의 조직파괴에 관여할 가능성이 저자들에 의해서 효소 및 조직치 구조 단백질의 gradation 효과를 관찰함으로써 시사되었다. 본 연구는 $H_2O_2$ 혹은 $H_2O_2$를 생성하는 효소계(xanthine과 xanthine oxidase 및 glucose과 glucose oxidase)에 $Cu^{++}$을 첨가하여 $Cu^{++}-H_2O_2$에 의한 peroxidation의 효과를 collagen gelation을 통하여 확인코저 수행하였으며 다음과 같은 결과를 얻었다. 1) $Cu^{++}(20\;{\mu}M)$$H_2O_2$에 의하며 collagen gelation은 현저히 억제되었으며 이같은 억제효과는 양자의 농도에 비례하였다. 2) $Cu^{++}-H_2O_2$ reactivity를 확인하는 다른 방법으로 glucose oxidase system를 이용하였다. glucose oxidase$(2.5{\mu}g/ml)$ 와 glucose(0.5 mM)는 collagen gelation에 영향을 미치지 않았으나 이에 $Cu^{++}$이 존재하면 gelation이 억제되었다. 이때 억제정도는 $glucose(0.125{\sim}l.25\;mM)$$Cu^{++}$의 농도에 비례하였다. 3) 여러 reactive oxygen species 가운데 $Cu^{++}-H_2O_2$ reactivity를 xanthine oxidase system을 이용하여 확인하였다. (a) collagen gelation은 xanthine oxidase(30 munits/ml)와 xanthine$(0.25{\sim}2\;mM)$에 의하여 억제되었다. (b) 이때 나타나는 collagen gelation의 억제는 superoxide dismutase에 의하여 완전히 회복되었으나 catalase에 의해서는 더욱 촉진되었다. 그러나 catalase에 의한 억제효과의 촉진은 1,4-diazabicyclo(2,2,2)octane에 의하여 완전히 소실되었다. 따라서 이 xanthine oxidase system에서는 $O_2-,\;H_2O_2,\;^1O_2$이 관여함을 알 수 있었다. (c) 그러나 $Cu^{++}(10\;{\mu}M)$이 존재하였을 때 collagen gelation은 superoxie dismutase에 의해 더욱 억제되었고 catalase에 의해서는 완전히 회복되었다. xanthine oxidase계에서 얻어진 결과는 여러 reactive oxygen species가운데 $H_2O_2$$Cu^{++}$에 의하여 peroxidation효과를 나타냄을 알 수 있었다. 이상의 결과로 미루어 볼 때 reactive oxygen species와 metal ions과의 상호작용 가운데 $Cu^{++}-H_2O_2$는 강한 반응을 나타내는 특이한 구성요소이고 헌재 시사되고 있는 reactive oxygen species의 biological effects에 비추어 $Cu^{++}-catalyzed peroxidation$도 병적상태에서 생체에 유해한 작용을 나타내는 요소임을 시사하며 특히 염증시 조직파괴역할에 관하여 고찰하였다.

  • PDF

Effects of Photoperiod, Light Intensity and Electrical Conductivity on the Growth and Yield of Quinoa (Chenopodium quinoa Willd.) in a Closed-type Plant Factory System

  • Austin, Jirapa;Jeon, Youn A;Cha, Mi-Kyung;Park, Sookuk;Cho, Young-Yeol
    • Horticultural Science & Technology
    • /
    • v.34 no.3
    • /
    • pp.405-413
    • /
    • 2016
  • Quinoa (Chenopodium quinoa Willd.) is a plant native to the Andean region that has become increasing popular as a food source due to its high nutritional content. This study determined the optimal photoperiod, light intensity, and electrical conductivity (EC) of the nutrient solution for growth and yield of quinoa in a closed-type plant factory system. The photoperiod effects were first analyzed in a growth chamber using three different light cycles, 8/16, 14/10, and 16/8 hours (day/night). Further studies, performed in a closed-type plant factory system, evaluated nutrient solutions with EC (salinity) levels of 1.0, 2.0 or $3.0dS{\cdot}m^{-1}$. These experiments were assayed with two light intensities (120 and $143{\mu}mol{\cdot}m^{-2}{\cdot}s^{-1}$) under a 12/12 and 14/10 hours (day/night) photoperiod. The plants grown under the 16/8 hours photoperiod did not flower, suggesting that a long-day photoperiod delays flowering and that quinoa is a short-day plant. Under a 12/12 h photoperiod, the best shoot yield (both fresh and dry weights) was observed at an EC of $2.0dS{\cdot}m^{-1}$ and a photosynthetic photon flux density (PPFD) of $120{\mu}mol{\cdot}m^{-2}{\cdot}s^{-1}$. With a 14/10 h photoperiod, the shoot yield (both fresh and dry weights), plant height, leaf area, and light use efficiency were higher when grown with an EC of $2.0dS{\cdot}m^{-1}$ and a PPFD of $143{\mu}mol{\cdot}m^{-2}{\cdot}s^{-1}$. Overall, the optimal conditions for producing quinoa as a leafy vegetable, in a closed-type plant factory system, were a 16/8 h (day/night) photoperiod with an EC of $2.0dS{\cdot}m^{-1}$ and a PPFD of $143{\mu}mol{\cdot}m^{-2}{\cdot}s^{-1}$.

Transient Spray Structures of Supersonic Liquid Jet Injected by Projectile Impact Systems (발사체 충격 방식을 사용한 초음속 액체 제트의 과도 분무 형상에 관한 연구)

  • Shin, Jeung-Hwan;Lee, In-Chul;Kim, Heuy-Dong;Koo, Ja-Ye
    • Journal of ILASS-Korea
    • /
    • v.17 no.2
    • /
    • pp.86-93
    • /
    • 2012
  • The effects of projectile impact system on the transient spray characteristic which is supersonic liquid tip velocity were studied by experimentally. Supersonic liquid jets were generated by impact of a high speed projectile driven by a Two-stage light gas gun. A high speed camera and schlieren optical system were used to capture the spray structures of the supersonic liquid jets. In a case of nozzle assembly Type-A, expansion gases accelerate a projectile which has a mass of 6 grams from 250 m/s at the exit of the launch tube. Accelerated projectile collides with the liquid storage part, then supersonic liquid jets are injected with instantaneous spray tip velocity from 617.78 m/s to 982.54 m/s with various nozzle L/d. However, In a case of nozzle assembly Type-B which has a heavier projectile (60 grams) and lower impact velocity (182 m/s), an impact pressure was decreased. Thus the liquid jet injected at 210 m/s of the maximum velocity did not penetrate a shock wave and fast break-up was occurred. Pulsed injection of liquid column generated second shock wave and multiple shock wave.

Real-Time Implementation of Shunt Active Filter P-Q Control Strategy for Mitigation of Harmonics with Different Fuzzy M.F.s

  • Mikkili, Suresh;Panda, Anup Kumar
    • Journal of Power Electronics
    • /
    • v.12 no.5
    • /
    • pp.821-829
    • /
    • 2012
  • This research article presents a novel approach based on an instantaneous active and reactive power component (p-q) theory for generating reference currents for shunt active filter (SHAF). Three-phase reference current waveforms generated by proposed scheme are tracked by the three-phase voltage source converter in a hysteresis band control scheme. The performance of the SHAF using the p-q control strategy has been evaluated under various source conditions. The performance of the proposed control strategy has been evaluated in terms of harmonic mitigation and DC link voltage regulation. In order to maintain DC link voltage constant and to generate the compensating reference currents, we have developed Fuzzy logic controller with different (Trapezoidal, Triangular and Gaussian) fuzzy M.F.s. The proposed SHAF with different fuzzy M.F.s is able to eliminate the uncertainty in the system and SHAF gains outstanding compensation abilities. The detailed simulation results using MATLAB/SIMULINK software are presented to support the feasibility of proposed control strategy. To validate the proposed approach, the system is also implemented on a real time digital simulator and adequate results are reported for its verifications.

A Study on the Application of a Wind Power Generation System Using Outdoor Air on the Rooftop and Indoor Ventilation (건물 옥상외기와 실내배기를 활용한 풍력발전시스템 적용 연구)

  • Lee, Yong-Ho;Park, Jin-Chul;Hwang, Jung-Ha
    • Journal of the Korean Solar Energy Society
    • /
    • v.34 no.1
    • /
    • pp.72-80
    • /
    • 2014
  • This study proposed a wind power generation system utilizing outdoor air on the rooftop and indoor ventilation, which would increase according to the building height, as a way to help to save energy consumption in a building by using wind power energy of the new renewable energy sources. The study measured the distribution of air currents and power generation according to the usage factor of exhaust pipes in the kitchen and bathroom and identified the elements to consider when applying a wind power generation system to buildings in order to use outdoor air on the rooftop increasing according to the height and the indoor ventilation produced in the facility vertical shafts inside the buildings by installing a wind power generation system on the rooftop. (1) The study measured the ventilation velocity of the kitchen hood and bathroom ventilation fan by changing the zone areas by the households according to the usage factor of [${\alpha}$]=33~100%. As a result, the kitchen ventilation pipe generated the ventilation wind of 3.0m/s or more at the usage factor of [${\alpha}$] 66% or higher, and the bathroom ventilation pipe generated ventilation velocity lower than 3.0m/s, the blade velocity of the wind power generator, even after the usage factor rose to [${\alpha}$]=100%. (2) As the old bathroom ventilation pipe generated the ventilation velocity of 3.0m/s, the blade velocity of the wind power generator, even with the rising usage factor [${\alpha}$], the application of an outdoor air induction module increased the ventilation velocity by 2.9m/s at the usage factor of [${\alpha}$]=33%, 3.8m/s at the usage factor of [${\alpha}$]=66%, and 3.6m/s at the usage factor of [${\alpha}$]=100%. Thus the ventilation velocity of 3.0m/s, the blade velocity of the wind power generator, or higher was secured. (3) The findings prove that the applicability of a wind power generation system using outdoor air on the rooftop and indoor ventilation is excellent, which raises a need for various efforts to increase the possibility of its commercialization such as securing its structural stability according to momentary gusts on the rooftop and typhoons in summer and making the structure light to react to the wind directions of outdoor air on the rooftop according to the seasons.

Development of Seoul Environmental Information System (서울시 환경정보시스템 구축방안)

  • 김윤종;조용현;원종석;김경민
    • Spatial Information Research
    • /
    • v.7 no.1
    • /
    • pp.13-27
    • /
    • 1999
  • This is a pilot study to develop an environmental information system, that is a compute. system for managing various urban environments data of S.M.C(Seoul Metropolitar City), and is also supporting the environmental policy decision-making for the city government. With 2 times of business analysis, the present status of environmental information management in S.M.C. and the major business processes and the data required to computerization were produced. As a result of this study, the model of S.E.I.S.(Seoul Environmental Information System) was developed, which includes the purpose of system, basic system components, and functions of subsystems. Finally a comprehensive strategy for developing the S.E.I.S which includes action plans and annual plans, organizaions for operation, and for project management was provided.

  • PDF

The Analysis of the M/M/1 Queue with Impatient Customers

  • Lee, EuiYong;Lim, Kyung Eun
    • Communications for Statistical Applications and Methods
    • /
    • v.7 no.2
    • /
    • pp.489-497
    • /
    • 2000
  • The M/M/1 queue with impatient customers is studied. Impatient customers wait for service only for limited time K/0 and leave the system if their services do not start during that time. Notice that in the analysis of virtual waiting time, the impatient customer can be considered as the customer who enters the system only when his/her waiting time does not exceed K. In this paper, we apply martingale methods to the virtual waiting time and obtain the expected period from origin to the point where the virtual waiting time crosses over K or reaches 0, and the variance of this period. With this results, we obtain the expected busy period of the queue, the distribution, expectation and variance of the number of times the virtual waiting time exceeding level K during a busy period, and the probability of there being no impatient customers in a busy period.

  • PDF

Cooling System Design of PM Synchronous Generator for KBP-2000M (KBP-2000M 풍력발전기용 영구자석형 동기발전기의 냉각시스템 설계)

  • Lee, H.G.;Kim, D.E.;Suh, H.S.;Han, H.S.;Jung, Y.G.;Lee, W.W.;Park, K.H.;Chung, C.W.
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2006.06a
    • /
    • pp.315-318
    • /
    • 2006
  • 포항풍력에너지연구소에서는 에너지 관리공단의 지원으로 2004년부터 풍력터빈 KBP-2000M에 사용될 발전기를 개발해 오고 있다. KBP-2000M에 사용되는 발전기는 기어비가 24인 기어박스를 가진 가변속도형식의 발전기이다. 발전기의 직경은 1.87m 이고 축 방향의 길이는 1.288m 로 영구자석을 사용하여 여자하는 형식으로 설계되었다. 이러한 설계는 풍력발전기에서 요구하는 주요 요구조건인 고효율, 고 신뢰성을 만족시키기 위해서 매우 중요하다 이 보고에서는 발전기의 물리설계에서 얻어진 사양을 기준으로 하여 열 해석에서 얻어진 열 손실을 이용하여 냉각시스템 설계를 하였으며 펌프 및 라디에이터 선정에 관해서 논의한다.

  • PDF