• Title/Summary/Keyword: M&S system

Search Result 10,213, Processing Time 0.037 seconds

A Robust EWMA Control Chart (로버스트 지수가중 이동평균(EWMA) 관리도)

  • Nam, Ho-Soo;Lee, Byung-Gun;Joo, Cheol-Min
    • Journal of the Korean Data and Information Science Society
    • /
    • v.10 no.1
    • /
    • pp.233-241
    • /
    • 1999
  • Control chart is a very extensively used tool in testing whether a process is in a state of statistical control or not. In this paper, we propose a robust EWMA(exponentially weighted moving averages) control chart for variables, which is based on the Huber's M-estimator. The Huber's M-estimator is a well-known robust estimator in sense of distributional robustness. In the proposed chart, the estimation of the process deviation is modified to have a s table level and high power. To compare the performances of the proposed control chart with other charts, some Monte Carlo simulations we performed. The simulation results show that the robust EWMA control chart has good performance.

  • PDF

The Development of An Environmentally Friendly Constructed Wetland System (친환경형 식물 정화조 시스템 개발)

  • Lee, Eun-Heui;Rhee, In-Sook;Jung, Dong-Sun
    • Journal of the Korean Society of Environmental Restoration Technology
    • /
    • v.7 no.4
    • /
    • pp.61-68
    • /
    • 2004
  • The purpose of this study was to develop environmentally friendly constructed wetland system in order to improve the environment. This system was constructed with two constructed wetlands andone pond. The size of the first and second wetland was 2.5m in length, 2.5m in width and 0.7m in depth for the first wetland and 0.6m in depth for the second wetland. Those were filled with pebbles with about 16~32mm in diameter from bottom to 20cm depth and onto the pebbles with about 0.5 mm in diameter sand in depth 40cm. The first constructed Wetland was planted with pragmites communis. The second was planted with Iris pseudoacorus and Acorus calamus var. aneustatus.A vertical flow system was used in the first constructed wetland and a horizontal flow system in the second. The water of outflow from the second wetland flowed into the pond. This system was installed in Yangpyeong, Kyunggi Province. The Quality of inflow and outflow were analyzed at the first time from May 20 to May 30, 2002 and at second time from June 10 to July 18, 2002. At the second period wetland was implanted with microbes in order to improve the efficiency of constructed wetlands. Following standard methods for wastewater, BOD, COD, SS, T-N and T-P were analyzed. This system was effective in reducing COD, BOD, SS, T-N and T-P level. The result shows that wastewater was purified through constructed wetland system with plants and highly purified with microbes especially in T-P. The Average total phosphorous concentration of influent and effluent in constructed wetland with microbes was 2.8mg/${\ell}$ L and 0.21mg/${\ell}$ respectively. This system can be used in rural community because this is not only effective on purification of sewage but also is harmonized with the surrounding nature.

Research on System Architecture and Simulation Environment for Cyber Warrior Training (사이버전사의 훈련을 위한 시스템 구축 방안 연구)

  • Ahn, Myung Kil;Kim, Yong Hyun
    • Journal of the Korea Institute of Information Security & Cryptology
    • /
    • v.26 no.2
    • /
    • pp.533-540
    • /
    • 2016
  • It is important to establish the environment for cyber warrior training, testing support and effectiveness analysis in order to cope with sharply increasing cyber threat. However, those practices cannot be easily performed in real world and are followed with many constraints. In this paper, we propose a live/virtual M&S-based system for training/testing and constructive M&S-based system for effectiveness analysis to provide an environment similar to real world. These can be utilized to strengthen the capability to carry out cyber war and analyze the impact of cyber threat under the large-scale networks.

A Study on Position of Six-Degrees-of-Freedom of vibration Model and Orientation Decision by Adaptive Control Method (6자유도 진동모댈의 위치 및 자세결정을 위한 적응제어기법의 적용에 관한 연구)

  • Kim, J.Y.;Song, S.K.;Han, J.H.;Oh, Y.H.;Cho, S.H.
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.2 no.6
    • /
    • pp.94-101
    • /
    • 1994
  • About vibration model of Six-degrees-of-freedom(DOF), in mass load, examined results for knowing dynamic interference and response variation is as follows; In case of putting mass load upon the object, experimented results on two-degrees-of-freedom of the translation-1 direction and the rotation-1 direction at open-loop-control system, about 0.19 arcsed in input of the translation-$0.1{\mu}m$ and $0.022{\mu}m$ on input of the rotation-0.5 arcsec, the justicse of motion equation is acknowledged as confirming the appearance of the interference-$0.022{\mu}m$. In establishing calculation of transformation matrix by using analogue circuit, as simulating results that used incomplete differentiation, interference is $1.7{\times}10^{-3}$ arcsec on input of the translation-$0.1{\mu}m$ and $1.4{\times}10^{4}{\mu}m$ on input of the rotation-0.5 arcsec in open-loop-control system. Also it is $4.2{\times}10^{-4}$ arcsec on input of the translation-$0.1{\mu}m$ and $5.6{\times}10^{-5}{\mu}m$ on input of the rotation-0.5 arcesc in closed-loop-control system. As closed-loop-control system is better than open-loop-control system, equivalent accordance is confirmed on original response. Finally, fundamental validity of this theory is acknowledged.

  • PDF

Swimming Performance Evaluation of Four Freshwater Fish Species from the South Korea (국내에 서식하는 담수어류 4종에 대한 유영능력 평가)

  • Misheel, Bold;Kim, Kyu-Jin;Min, Kun-Woo;Jang, Min-Ho
    • Korean Journal of Ecology and Environment
    • /
    • v.52 no.2
    • /
    • pp.118-125
    • /
    • 2019
  • Swimming performance of fish is an important factor in the survival of fish. Also, swimming performance of fish is used in the form of habitat, or as a condition to consider when creating a fish ladder. However in Korea, researches in swimming performance of Korean freshwater fish were scarce and inadequate in some part, thus fish ladders were installed without considering their swimming performance. Therefore, in this study, we measured swimming performance of 4 Korean freshwater fish species to consider importance of swimming performance test. The fish used in this study were Carassius auratus, Zacco koreanus, Gnathopogon strigatus, Acheilognathus lanceolata intermedia species which was collected during October to November, 2018 at Geum River, and measurement for swimming speed of each fish was done by using $Loligo^{(R)}$ System, swim tunnel respirometer in January to February of 2019. The average value of the burst critical swimming speed ($U_{crit}$) for each species was $0.8{\pm}0.04m\;s^{-1}$ for C. auratus, $0.77{\pm}0.04m\;s^{-1}$ for Z. koreanus, $0.95{\pm}0.04m\;s^{-1}$ for G. strigatus, $0.73{\pm}0.03m\;s^{-1}$ for A. lanceolata intermedia and the average value of prolonged critical swimming speed was $0.54m\;s^{-1}$ for C. auratus, $0.67m\;s^{-1}$ for Z. koreanus, $0.7m\;s^{-1}$ for G. strigatus, $0.54m\;s^{-1}$ for A. lanceolata intermedia. Since the fish used in this experiment were collected from a small part of the water system in Korea and there were only 4 species, they were not enough to represent the species that inhabit the entire Korean water system. It will be necessary to continue evaluating the swimming performance of other freshwater species in Korea.

An experimental study on the performance of the separate type heat pipe in accordance with the refrigerant charge (냉매 충진량에 따른 분리형 히트파이프 성능에 관한 실험적 연구)

  • Jeon, Sung-Taek;Cho, Jin-Pyo
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.3
    • /
    • pp.1600-1604
    • /
    • 2015
  • As modern houses are constructed with high-density and high-insulation, there is benefit to reduce energy consumption, but there are many side effects raised from polluted air. To solve the problem, a ventilation system is used to improve a indoor air quality. In this research, we experimentally estimate ventilation performance of HRV(heat recovery ventilator) with heat-pipe according to working fluid filling quantity and ventilation. Heat-pipe used in this study was designated separately to be applied to a ventilation system. The working fluid was R22, which was filled from 40 to 55 (%vol.) by 5(%vol.). Ventilation based on the front velocity was measured from 0.3 m/s to 1.5 m/s by 0.3 m/s intervals. Refrigerant filling quantity with the highest efficiency was found to depend on the ventilation. From this study the optimal refrigerant filling quantity in accordance with the ventilation of the detachable heat pipes was found experimentally.

Radioiodination-IV & V-Study on the radioiodination of organic compounds by a hydrogen peroxide procedure (방사성요오드화반응-IV,V보-과산화수소를 이용한 요오드표지 합성법의 검토)

  • You sun Kim;Tae young Kim
    • Journal of the Korean Chemical Society
    • /
    • v.14 no.2
    • /
    • pp.169-177
    • /
    • 1970
  • A study was made on the radioiodination of organic compounds in presence of hydrogen peroxide both in aqueous and organic solvent systems. In case of the reaction of rosebengal, Hippuran, and 5-iodo-uracil the aqueous reaction system could give high labelling yield within a relatively short reaction time. Labelling yield of average 50% could be obtained within 30 minutes of reaction sequence. In cases of organic solvent systems (D.M.S.O., D.M.F., and Dioxane) the solvent system of D.M.S.O. could give better yield for neutral organic compounds, where as D.M.F. and Dioxane gave better labelling result for acidic materials. Especially, o-iodobenzoic acid, o-iodotoluene, and pentachlorophenol could be labelled better in organic solvent system.

  • PDF

The characteristic of penetration on the 800Mpa class high-tensile steel using remote welding system by $CO_2$ laser ($CO_2$ 레이저 원격 용접시스템을 이용한 800Mpa급 고장력강의 용입특성)

  • Song, M.J.;Lee, Y.J.;Song, Y.C.;Jung, S.M.;Jung, B.H.;Lee, M.Y.
    • Proceedings of the Korean Society of Laser Processing Conference
    • /
    • 2006.11a
    • /
    • pp.17-20
    • /
    • 2006
  • In the remote welding system using $CO_2$ laser, laser beam is rapidly deflected by moving mirrors of scanner system and has focusable distance over 1000mm from workpiece. From such arrangement, various advantages and disadvantages arise. Remote welding is a highly efficient laser process. As the mirrors of the scanner system allow positioning speeds exceeding 700m/s, it becomes possible to reduce the welding cycle time. On the other hand, as there no the provision of shielding gas which is normally required for beam powers exceeding 3kW, may become difficult task. Therefore, In this study, the influence of the various penetration of back bead by the different laser welding speed on the weld seam formation without shielding gas was investigated.

  • PDF

Effects of Field Configuration Shielding Area and Changing of Density and Sensitivity on Tube Current and Image Quality in Automatic Exposure Control System (자동노출제어장치의 채광창 차폐정도와 농도, 감도의 변화가 관전류량과 영상품질에 미치는 영향)

  • Jeong, Min-Gyu;Seoung, Youl-Hun
    • Journal of the Korean Society of Radiology
    • /
    • v.14 no.5
    • /
    • pp.635-642
    • /
    • 2020
  • The purpose of this study was to analysis the effects of shielding area of field configuration with changing of sensitivity and density on tube current (milliampere-seconds, mAs) and image quality in automatic exposure control (AEC) system. The equipment used a digital radiography device (Digital Diagnost, Philips, Netherlands), which has a integral type with an X-ray tube and an indirect digital detector. The AEC system conditions were consisted of 9 setting environments, that mode changing of the sensitivity (S200, S400, S800) and the density (+2.5, 0, -2.5). The tube current evaluated automatically exposed mAs under 81 combination conditions crossed by AEC conditions in fixed at 40 kVp. The image quality evaluated the radiographic images that selected valid images by visual assessment the radiographic images of the self-produced conical pyramid phantom and then measured their signal to noise ratio (SNR). As a result, the maximum tube current was 60.0 mAs that automatically exposed conditions were the 100% of shielding area and the sensitivity of S200 and the density of +2.5. The minimum tube current was 0.9 mAs with non-shielding area and the sensitivity of S800 and the density of -2.5. When the shielded area 0% with the sensitivity of S200 and the density of +2.5, the maximum SNR was the highest as 25.2. But when the shielded area 25% with the sensitivity of S800 and the density of -2.5, the minimum SNR was the lowest as 4.7.

PTCR Effects in Molten Salt System Synthesized Semiconductive $BaTiO_3$ (용융염 합성법에 의한 반도성 $BaTiO_3$의 PTCR 효과)

  • 윤기현;오기영
    • Journal of the Korean Ceramic Society
    • /
    • v.22 no.3
    • /
    • pp.13-18
    • /
    • 1985
  • Semiconductive $Ba_{0.9}Sr_{0.1}TiO_3$ was prepared by both the Calcining of mixed Oxides (C. M. O) and the Molten Salt Synthesis(M.S.S) methods to investigate the PTCR effects. In the Molten Salt Synthesis method the temperature of calcination for Synthesis of $BaTiO_3$ could be lowered from 110$0^{\circ}C$ to 80$0^{\circ}C$. The M.S.S Specimens had smaller grain size and more homogeneous size distribution at the same sintering temperature as compared with the C. M. O specimens. The M. S. S. specimens showed greater PTCR effects and current variations in the time vs. current charac-teristics than those of C. M. O Specimens.

  • PDF