• 제목/요약/키워드: M&C

검색결과 39,934건 처리시간 0.066초

$28 A/cm^2~ 940 A/cm^2$의 임계전류밀도 범위로 제작된 $Nb/Al-AlO_x/Nb$ 터널접합의 전기적 특성 (Electrical Characteristics of $Nb/Al-AlO_x/Nb$ Tunnel Junction fabricated with $I_c$ Values in the Range of $28 A/cm^2~ 940 A/cm^2$)

  • 홍현권;김규태;박세일;김구현;남두우
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제4권1호
    • /
    • pp.4-7
    • /
    • 2002
  • Samples of $Nb/Al-AlO_x/Nb$ tunnel junction with the size of $50 ${\mu}{\textrm}{m}$ {\times} 50 ${\mu}{\textrm}{m}$$ were fabricated by using self-aligning and reactive ion etching technique In the high quality samples, the $V_m$ value (the product of the critical current and subgap resistance measured at 2 mV) was 34 mV at the critical current density of $J_c: 500 A/cm^2 and the V_g$ value (the gap voltage) was 2.8 mV. For the higher $J_c$ sample, voltage fluctuation at the gap voltage was observed. The $V_m and J_c$ values for this sample were 8 mV and 900 A/cm$^2$, respectively. Also, the relationship between critical current density $J_c$ and specific normal conductance $G_s$ of the junctions with $J_c$ in the range of 28 A/cm$^2$~940 A/cm$^2$was investigated.

냉방과 난방 부하 감소를 위한 지하피트의 이용 가능성 (The Possibility on Utilization of Underground Pit for Reduction of Cooling and Heating Load)

  • 조성우
    • 설비공학논문집
    • /
    • 제18권2호
    • /
    • pp.144-150
    • /
    • 2006
  • The purpose of this study is to predict outlet temperature and humidity through underground pit for the reduction of cooling load and heating load. Commonly, the underground temperature is lower than outdoor in summer but the reverse happens in winter. When the outdoor average air temperature is $25.7^{\circ}C$ during cooling periods, the average outlet air temperature through underground pit is $23.6^{\circ}C$ with 3 m-depth and 60m-length and is $22.2^{\circ}C$ with 3 m-depth and 150 m-length. When the outdoor average air temperature is $4.9^{\circ}C$ during heating periods, the average outlet air temperature through underground pit is $7.7^{\circ}C$ with 3m-depth and 60 m-length and is $10.8^{\circ}C$ with 3 m-depth and 150 m-length. The outlet air temperature is affected by more length than depth of underground pit. The diffusion ratio of outdoor humidity is $-7.7\times10^{-8}kg/s$ in cooling periods and $9.29\times10^{-7}kg/s$ in heating periods.

한국산 집박쥐의 성적 이형 및 형태학적 특징에 관한 연구 (Sexual Dimorphism and Morphological Characteristics of Pipistrellus abramus (Chiroptera: Vespertilionidae) in Korea)

  • 김성철;전영신;정철운
    • 한국환경과학회지
    • /
    • 제32권4호
    • /
    • pp.277-284
    • /
    • 2023
  • Seventy Pipistrellus abramus samples were caught to analyze their sexual dimorphism and mophological characteristics. The mean HB and FA were 50.86 mm and 34.93 mm, respectively, based on external measurements and skull shape. The length of the TL, Hfcu, and Tra were approximately 70%, 55.6%, and 38% of the HB, Tib, and E, respectively. Both the lambdoid crest and the sagittal crest were well developed and the H.BC was approximately 84% of the W.BC. P2 was inside the toothrow and metacone of canine was clearly visible. According to the analysis of sexual dimorphism, the following characteristics were different in between males and females: WS, C-M3, C-C, M3-M3, LOM, LUC, and i-m3. The WS, C-M3, C-C, M3-M3, LOM, and i-m3 were bigger in females than males, whereas the LUC was bigger in males.

페이퍼드레인 공법에 의한 연약지반의 압밀거동 (Consolidation Behavior of Soft Ground by Prefabricated Vertical Drains)

  • 이달원;강예묵;김성완;지인택
    • 농업과학연구
    • /
    • 제24권2호
    • /
    • pp.145-155
    • /
    • 1997
  • 본 연구는 현재 시공중인 사업부지를 선정하여 시험시공중에 있는 연약지반에서 페이퍼 드레인 공법에 의하여 처리한 지반에서 드레인의 타입간격별 침하거동을 파악하고, 실내시험과 현장계측치로부터 구한 압축지수와 압밀계수를 비교분석하여 배수성능의 우수성을 평가한 것으로 그결과를 요약하면 다음과 같다. 1. 실측침하량($S_m$)과 설계침하량($S_t$)의 관계 및 실측압밀도($U_m$)와 설계압밀도($U_t$)와의 관계는 드레인 타입간격 1.0m에서는 $S_m=(1.0{\sim}1.1)S_t$, $U_m=(1.13{\sim}1.17)U_t$로 나타났고, 드레인 타입간격 1.5m에서는 $S_m=(0.7{\sim}0.8)S_t$, $U_m=0.92{\sim}0.99)U_t$의 범위로 나타났다. 2. 현장압축지수($Cc_{Field}$)와 처녀압축지수($V_{CC_{lab.}}$)와의 관계는 $Cc_{Field}=(1.0{\sim}1.2)V_{CC_{lab.}}$로 나타났으나, 처녀압축지수의 결정밥법과 최종예상 침하량의 적용방법에 따른 오차를 감안하면 거의 동일한 것으로 판단된다. 3. 계측치로부터 역산한 현장압밀계수는 실내시험에서 구한 압밀계수보다 크게 나타났고, 압밀계수비($C_h/C_v$)는 드레인 타입간격 1.0m에서는 $C_h=(2.4{\sim}3.0)C_v$, 드레인 타입간격 1.5m에서는 $C_h=(3.5{\sim}4.3)C_v$의 범위로 타입간격이 넓을수록 크게 나타났다. 4 드레인 타입간격에 따른 드레인 자재별 배수성능 평가기준을 압밀계수비의 결과를 기초로 판단하여 보면, 드레인 타입간격 1.0m에서는 Mebra 드레인, 드레인 타입간격 1.5m에서는 Amer드레인이 약간 우수한 것으로 나타났으나, 동일한 타입간격에서는 재질간의 큰차이가 발생되지 않아 모두 동일한 배수성능을 갖는 것으로 판단된다.

  • PDF

옥외 자립형 PANEL에 적용한 전자냉각장치 고찰 (The consideration of the electronic cooling device for outside panel)

  • 옥연호;임재일;박지군;곽원구;이재흥;김병기
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2008년도 제39회 하계학술대회
    • /
    • pp.353-354
    • /
    • 2008
  • 옥외 현장에 설치되어 있는 PANEL은 하절기에 내부 온도가 높아져 PANEL 내부에 설치되어 있는 제어장치의 정상 동작을 방해 할 수 있다. 실제로 하절기 오후 $2{\sim}3$시경 PANEL 내부의 온도는 약 $60{\sim}75^{\circ}C$ 정도의 고온을 유지한다. 근래에는 현장 PANEL 내부에 PLC 및 컨트롤러등 전자화된 제어 장치의 설치 비중이 증가하고 있고 대부분의 컨트롤러 사용 온도는 약 $0{\sim}55^{\circ}C$ 이므로 하절기 고온 상태에서 정상적인 동작을 기대하기는 어렵다. 본 논문에서는 옥외 자립형 PANEL의 냉각 장치를 개발하여 운영하고 그 효과를 분석, 검토함으로써 하절기 고온 상태에서도 안정적으로 설비가 정상 동작하기 위한 방안 제시를 주요 목적으로 한다.

  • PDF

Hydroxy Propyl Methyl Cellulose 분진의 습도와 온도에 대한 영향성 연구 (A Study on The Effect of Humidity and Temperature of Hydroxy Propyl Methyl Cellulose Dust)

  • 임우섭;목연수;최재욱
    • 한국안전학회지
    • /
    • 제19권3호
    • /
    • pp.65-69
    • /
    • 2004
  • This study was performed with Hartmann type dust explosion apparatus and Godbert-Greenwald furnace apparatus in order to research the effect of temperature and humidity affecting LEL, minimum ignition temperature of Hydroxy Propyl Methyl Cellulose. The experimental determinations in the range between $20^{\circ}C\;and\;60^{\circ}C$ of temperature was not affected $LEL(180g/m^3)$ but LEL showed $200g/m^3\;and\;250g/m^3\;at\;80^{|circ}C\;and\;100^{\circ}C$. As the change of humidity LEL was $180g/m^3\;for\;50\%,\;200g/m^3\;for\;60\%\;and\;250g/m^3\;for\;70\%$ but dust explosion didn't occur over $80\%$. The ignition temperature of HPMC dust clouds was increased as increasing of humidity. So, the minimum ignition temperatures at $50\%,\;60\%,\;70\%\;80\%$ of humidity was $363^{\circ}C,\;375^{\circ}C,\;397^{\circ}C,\;405^{\circ}C$.

Studies on the interaction of Azo dyes with cationic surfactant(1)

  • Cho, Yung-Mee;Lee, Wang-Kyu;Kim, Bak-Kwang
    • Archives of Pharmacal Research
    • /
    • 제4권2호
    • /
    • pp.75-84
    • /
    • 1981
  • As the cetyltrimenthy ammonium bromide (CTAB) concentration increases to $2{\times}10^{-4}$/M the absorption maximum of ethyl orange (EO) makes a blue shift from 475 mm to 395 mm. At higher concentration of CTAB than $2{\times}10^{-4}$ / M the absorption maximum shifts to higher wavelength than 395 nm. A new peak at 395 nm is shown to result from the mixed micelle due to dye stacking interaction rather than from a change in dye geometry. Because Raman spectra of EO on interaction with varying amount of CTAB are similar to that of EO in water. EO retains trans azo type on interaction with CTAB. There is a change of c.m.c.s. of CTAB for the mixed micelle in the presence of salt. The effect of added salt on C. M. C. of CTAB for the mixed micelle is given that the logarithm of the c. m. c. is a linear function of the logarithm of the sum of the c. m. c. and the concentration of added salt.

  • PDF

1,2,3-트리아졸 폴리머의 상호계수 χ의 결정 (Determination of Interaction Parameter χ of the 1,2,3-Triazole Crosslinked Polymer)

  • 이동훈;이수경;김경태;백현종;전흥배;민병선;김원호
    • Elastomers and Composites
    • /
    • 제48권2호
    • /
    • pp.148-155
    • /
    • 2013
  • 폴리머의 가교밀도는 팽윤 실험 데이터를 이용한 Flory-Rehner 식에 의하여 정량적으로 계산할 수 있는데, Flory-Rehner 식에서 상호계수 (${\chi}$) 항에 있는 lattice constant ${\beta}_1$ 값은 주의해서 선정되어야 한다. 이 ${\beta}_1$ 값은 경험에 의한 실험값으로 연구자에 따라 조금씩 다른 값이 선택되어 사용되고 있다. 일반적으로 Mooney-Rivlin 식에서 가교점 사이의 평균 분자량 $M_c$ 값은 Flory-Rehner 식에서의 $M_c$ 값과 동일한 의미를 가지며 Mooney-Rivlin 식으로부터 $M_c$ 값을 구하면 Flory-Rehner 식에서 ${\beta}_1$ 값을 구할 수 있다. 따라서 본 연구에서는 먼저 Flory-Rehner 식의 상호계수 (${\chi}$) 항의 ${\beta}_1$ (=0.34) 과 1,2,3-트리아졸 폴리머의 팽윤 실험 데이터를 적용하여 $M_c$ 값을 계산하고, 두 번째로 인장 실험 데이터를 이용한 Mooney-Rivlin 식을 이용하여 $M_c$ 값을 계산 후 비교하였다. 결과적으로 두 개의 $M_c$ 값이 거의 유사하여 Flory-Rehner 식의 상호계수 (${\chi}$) 를 위해 선정한 ${\beta}_1$ (=0.34) 값이 적절함을 증명하였다.

반응표면분석에 의한 옥수수유 유래 monoacylglycerol과 diacylglycerol 합성 조건의 최적화 (Optimization for the Production of Mono- and Di-acylglycerols from Corn Oil by Enzymic Glycerolysis Using Response Surface Methodology)

  • 박래균;최상원;이기택
    • 한국식품과학회지
    • /
    • 제36권5호
    • /
    • pp.717-722
    • /
    • 2004
  • Lipozyme RM IM 효소적 촉매를 사용한 glycerolysis에 의한 옥수수유로부터 $1,3-DAG(Y_1),\;1,2-DAG(Y_2)$, 총 $DAG(Y_3),\;MAG (Y_4)$, 및 총 DAG + MAG 의 합성 양$(Y_5)$의 생성 최적화를 반응 표면분석을 이용하여 모니터링 하였으며 반응온도$(35-75^{\circ}C,\;X_1)$, 반응시간$(1-11시간,\;X_2)$ 및 hexane 의 혼합 양$(0-2mL,\;X_3)$을 변수로 한 중심합성계획으로 최적화 실험하였다. 1,3-DAG는 반응온도$(44.92^{\circ}C)$, 반응시간(10.24시간) 및 hexane 첨가량(1.16mL) 조건에서 20.43 area%로 최대값을 나타내었으며 1,2-DAG는 $56.32^{\circ}C$, 6.95시간 및 1.04mL 조건에서 26.78 area% 로 최대값을 예측할 수 있었다. 총 DAC는 $53.82^{\circ}C$, 8.03시간 및 1.08mL 실험 조건에서 45.09 area% 최대값을 보였다. 또한 MAG 생산 최적조건은 $64.14^{\circ}C$, 7.00시간 및 0.13mL에서 최대값 9.57 area%로 예측되었으며 총 DAG+MAG 생산 최적조건은 $54.07^{\circ}C$, 7.98시간, 1.02mL이었으며 이때 예측된 값은 53.54 area%이었다.

태백(太白) 산간지방(山間地方)에서의 기온체감율(氣溫遞減率)과 수도(水稻) 안전작기설정(安全作期設定) (Lapse Rate of Air Temperature and Optimizing Rice Cultivation Period in the Taebaek Mountainous Area)

  • 이양수;정영상;이정택
    • 한국토양비료학회지
    • /
    • 제17권3호
    • /
    • pp.307-313
    • /
    • 1984
  • 우리나라 중북부(中北部) 산간지방(山間地方)의 표고별(標高別) 온도(溫度) 체감율(遞減率)을 밝히기 위(爲)하여, 강원도(江原道) 평창군내(平昌郡內) 표고(標高)가 다른 3개지점(個地点)에서 측정(測定)된 최고기온(最高氣溫), 최저기온(最低氣溫)의 6개년(個年) 평균치(平年値)(1977~1982年) 기상자료(氣象資料)를 이용(利用)하여 표고(標高) 상승(上昇)에 따른 평균기온(平均氣溫) 체감율(遞減率)을 밝히고, 그 이용방안(利用方案)으로 일평균(月平均) 기온(氣溫)을 추정(推定)하여 표고별(標高別)로 이론적(理論的) 수도재배(水稻栽培) 기간(期間)을 설정(設定)한 결과(結果)는 아래와 같다. (1) 표고(標高)가 상승(上昇)함에 따라 월평균기온(月平均氣瑥)은 일정(一定)한 비율(比率)은 체감(遞減)하여, 표고(標高) 100m 상승(上昇)함에 따라 $0.53^{\circ}C{\sim}1.02^{\circ}C$의 범위(範圍)에서 평균기온(平均氣溫)이 체감(遞減)하였으며, 연평균체감율(年平均遞減率)은 $0.69^{\circ}C/100m$이었다. (2) 표고(標高)가 l00m 상승(上昇)함에 따라 약 7~8일(日)의 수도재배(水稻栽培) 가능기간(可能期間)이 짧아지는 것으로 나타났다. (3) 소요적산온도(所要積算溫度) $1,800^{\circ}C$ 되는 품종(品種)은 표고(標高) 300m까지, $1,400^{\circ}C$ 이하(以下) 품종(品種)은 500m, $1,200^{\circ}C$ 정도(程度)의 극조생종품종(極早生種品種)은 표고(標高) 600m까지 재배가능(栽培可能)한 것으로 나타났다. (4) 표고별(標高別) 출수기(出穗期) 만한일(晩限日)은 표고(標高) 300m에서 8월(月) 15일(月)이었으며 100m 상승(上昇)함에 따라 4~5일(日)씩 앞당겨지는 경향(傾向)이었다.

  • PDF