• 제목/요약/키워드: Lumped Model

검색결과 529건 처리시간 0.03초

750kW 풍력발전기 타워 구조의 진동 특성 (Vibration Characteristics of the Tower Structure of a 750kW Wind Turbine Generator)

  • 김석현;남윤수;은성용
    • 한국소음진동공학회논문집
    • /
    • 제15권2호
    • /
    • pp.219-224
    • /
    • 2005
  • Vibration response of the tower structure of a 750kW wind turbine (W/T) generator is investigated by measurement and analysis. Acceleration response of the W/T tower under various operation condition is monitored in real time by the vibration monitoring system using LabVIEW. Resonance state of the tower structure is diagnosed in the operating speed range. Resonance frequency range of the test model is investigated with the wind speed data of the test site. To predict the tower resonance frequency, tower is modeled as an equivalent beam with a lumped mass and Rayleigh energy method is applied. Calculated tower bending frequency is in good agreement with the measured value and the result shows that the simplified model can be used in the design stage of the W/T tower.

MODELING AND PARAMETER IDENTIFICATION FOR A PASSIVE HYDRAULIC MOUNT

  • Zhang, Y.X.;Zhang, J.W.;Shangguan, W.B.;Feng, Q.Sh.
    • International Journal of Automotive Technology
    • /
    • 제8권2호
    • /
    • pp.233-241
    • /
    • 2007
  • A lumped parameter model is proposed for the analysis of dynamic behaviour of a Passive Hydraulic Engine Mount (PHEM), incorporating inertia track and throttle, which is characterized by effective and efficient vibration isolation behaviour in the range of both low and high frequencies. Most of the model parameters, including volume compliance of the throttle chamber, effective piston area, fluid inertia and resistance of inertia track and throttle are identified by an experimental approach. Numerical predictions are obtained through a finite element method for responses of dynamic stiffness of the rubber spring. The experiments are made for the purpose of PHEM validation. Comparison of numerical results with experimental observations has shown that the present PHEM achieves good performance for vibration isolation.

Properties of Hydrologic Cycle in Catchments in Different Land Use and Runoff Analysis by a Lumped Parametric Model

  • Keiji Takase
    • 한국수자원학회:학술대회논문집
    • /
    • 한국수자원학회 2000년도 학술발표회 논문집
    • /
    • pp.48-56
    • /
    • 2000
  • In this paper, properties of hydrologic cycle in three experimental catchments were compared and different types of a lumped parametric model were applied to understand the hydrologic cycle in the catchments. One of them is a forest catchment and another one includes the reclaimed upland fields and last one does terraces paddy fields. The comparison of hydrologic properties showed that the differences in land use have great influences on the soil properties of surface layer, which changes in hydrologic processes such as evapotranspiration and storm runoff et. al. By the runoff analysis models, good agreements between observed and calculated discharge from the catchments were obtained and it was found that the differences in values of optimized model parameters and water budget components reflect those in the hydrologic cycle among them.

  • PDF

사각 맴돌이 인덕터의 개량된 등가회로 모델 (A Modified Equivalent Element Model for Square Spiral Inductor)

  • 안동식;장동필;오승겹
    • 전자공학회논문지B
    • /
    • 제32B권10호
    • /
    • pp.1286-1293
    • /
    • 1995
  • Modified equivalent lumped element model for square spiral inductors have been derived. This model shows more accurate analysis performance than conventional models, and gives reliable design parameters. And this model is made through comparison among distributed multiple coupled line, numerical analysis and experimental data.

  • PDF

토지이용 변화에 따른 수문 특성의 변화를 추적하기 위한 Lumped모형의 개발 (Development of lumped model to analyze the hydrological effects landuse change)

  • 손일
    • 대한지리학회지
    • /
    • 제29권3호
    • /
    • pp.233-252
    • /
    • 1994
  • 토지이용수문학을 위한 하나의 대안으로, 모형의 단순성, 모형변형의 용이성, 그리 고 모의된 모형으로부터 지속적인 유량 예측 능력을 지닌 Lumped모형을 이용해 토지이용 변화에 따른 수문특성의 변화를 추적하였다. Blackie(1972)의 모형을 근간으로, R1131(11-parameter, 3-storage, l-input option) 모형을 구축하였다. 연구 대상 유역분지는 케냐에 있는 Kimakia Catchement K11이며, 이곳의 토지이용은 3번 변화하였다. 3단계의 토 지이용 기간에 대해 모형을 보정한 결과, 모형유효도는 96.78%, 97.20%, 94.62%이며, 전체유 량오차는 각각 -1.78%, -3.36%, 5.32% 였다. 보정된 모형을 이용해 각 토지이용 단계별로 확장유출량을 발생시키고, 빈도해석을 시도했다. 홍수 규모가 작은 경우 식생변화에 따라 31.3%와 32.1% 정도로 홍수량이 줄어들었으나, 홍수 규모가 커짐에 따라 홍수량의 감소 정 도는 점차 작아지고 있다. 이와 같은 현상은 갈수량의 변화에서도 발견된다. 또한 식생이 어 느 정도까지 성장한 이후에는 계속된 식생 성장에도 불구하고 홍수량과 갈수량은 큰 변화가 없다.

  • PDF

Improving the linear flexibility distribution model to simultaneously account for gravity and lateral loads

  • Habibi, AliReza;Izadpanah, Mehdi
    • Computers and Concrete
    • /
    • 제20권1호
    • /
    • pp.11-22
    • /
    • 2017
  • There are two methods to model the plastification of members comprising lumped and distributed plasticity. When a reinforced concrete member experiences inelastic deformations, cracks tend to spread from the joint interface resulting in a curvature distribution; therefore, the lumped plasticity methods assuming plasticity is concentrated at a zero-length plastic hinge section at the ends of the elements, cannot model the actual behavior of reinforced concrete members. Some spread plasticity models including uniform, linear and recently power have been developed to take extended inelastic zone into account. In the aforementioned models, the extended inelastic zones in proximity of critical sections assumed close to connections are considered. Although the mentioned assumption is proper for the buildings simply imposed lateral loads, it is not appropriate for the gravity load effects. The gravity load effects can influence the inelastic zones in structural elements; therefore, the plasticity models presenting the flexibility distribution along the member merely based on lateral loads apart from the gravity load effects can bring about incorrect stiffness matrix for structure. In this study, the linear flexibility distribution model is improved to account for the distributed plasticity of members subjected to both gravity and lateral load effects. To do so, a new model in which, each member is taken as one structural element into account is proposed. Some numerical examples from previous studies are assessed and outcomes confirm the accuracy of proposed model. Also comparing the results of the proposed model with other spread plasticity models illustrates glaring error produced due to neglecting the gravity load effects.

단순모델을 이용한 막 가습기 열 및 물질 전달 특성 해석 (Mass and Heat Transfer Analysis of Membrane Humidifier with a Simple Lumped Mass Model)

  • 유상석;이영덕;배호준;황준영;안국영
    • 대한기계학회논문집B
    • /
    • 제33권8호
    • /
    • pp.596-603
    • /
    • 2009
  • The performance of proton exchange membrane fuel cell (PEMFC) is seriously changed by the humidification condition which is intrinsic characteristics of the PEMFC. Typically, the humidification of fuel cell is carried out with internal or external humidifier. A membrane humidifier is applied to the external humidification of residential power generation fuel cell due to its convenience and high performance. In this study, a simple static model is constructed to understand the physical phenomena of the membrane humidifier in terms of geometric parameters and operating parameters. The model utilizes the concept of shell and tube heat exchanger but the model is also able to estimate the mass transport through the membrane. Model is constructed with FORTRAN under Matlab/$Simulink^{(R)}$ $\Box$environment to keep consistency with other components model which we already developed. Results shows that the humidity of wet gas and membrane thickness are critical parameters to improve the performance of the humidifier.

전기 집진기의 진동 탈진을 위한 전자기 진동 가진기의 집중매개변수 모델링 및 해석 (Lumped Parameter Modeling and Analysis of Electromagnetic Vibration Exciter for Vibrating Rapper of Electrostatic Precipitator)

  • 김제훈;이정훈;김진호;정상현;한방우
    • 한국자기학회지
    • /
    • 제21권2호
    • /
    • pp.61-66
    • /
    • 2011
  • 도시철도의 대기 중의 오염 물질을 정화하여 공기 질을 개선하기 위해 사용되는 전기 집집기시스템은 터널 내의 제한된 공간내의 설치문제로 인해 소형화가 매우 중요하다. 따라서, 집진 시스템의 탈진 설비 또한 소형화가 매우 중요한 실정이다. 이를 위해, 고효율 소형 전자기 진동 가진기를 이용한 전기 집진기 탈진 설비가 최근 활발히 연구 중에 있다. 유한요소해석은 전자기 진동 가진기의 설계 및 동적성능을 해석을 위해서 가장 널리 이용되고 있는 방법이지만, 해석 시간이 매우 길고, 특히 최적화를 위한 반복 계산에서 많은 시간을 소비한다. 집중매개변수해석은 짧은 시간에 정확하게 반복 계산을 할 수 있는 장점 때문에 유한 요소해석을 대신하여 많이 사용되고 있다. 본 논문에서는 전기 집진기의 진동 탈진을 위한 전자기 진동 가진기의 집중매개변수 모델링을 생성하고 이를 통해 동적 해석을 수행하였다. 또한, 집중매개 변수 해석 결과를 검증하기 위해 유한요소해석을 수행하고 두 해석 결과를 비교 분석하였다.

이중외피 형상에 따른 모델 보정과 local 기상 정보의 필요성 (Calibration of Double-skin Simulation Model Depending on Configuration And Impact of Local Weather Information)

  • 윤경수;김덕우;이건호;박철수
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2009년도 추계학술발표대회 논문집
    • /
    • pp.142-147
    • /
    • 2009
  • In order to achieve performance assessment and optimal control of a double-skin system, an accurate simulation model is required. In the previous study, a lumped simulation model of such system was developed. As a follow-up of the previous research, the first objective of this paper is to investigate how the mathematical model should be calibrated according to system configuration(cavity width, depth, height, airflow pattern, local environment, etc.). And the second objective of this study is to discuss the effect of local weather information. In conclusion, this paper describes that the model should be recalibrated according to configuration. And it is necessary to have local weather information for accurate prediction and optimal control of the system.

  • PDF

Rack/Pinon 방식의 5-Head 라우터 머신 이송 시스템의 진동해석 (Vibration Analysis of a Rack and Pinon Typed Feed Drive System for a 5-Head Router Machine)

  • 최영휴;최응영;장성현;하종식;조용주
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2005년도 춘계학술대회논문집
    • /
    • pp.269-272
    • /
    • 2005
  • In order to prevent a router machine feed drive system from transient operational vibration, this paper presents vibration analysis of a rack and pinion typed feed drive system for a router machine. The feed drive system was mathematically idealized as a 5-degree-of-freedom lumped parameter model. Stiffness parameters of motor-shaft, rack and pinion gears, and machine structure were appropriately considered in the modeling. Computational experiment was carried out to obtain vibrations of the feed drive system during its transient speed operation.

  • PDF