• 제목/요약/키워드: Lumped Model

검색결과 531건 처리시간 0.025초

1 차원 Lumped 모델을 이용한 산업용 잉크젯 프린팅 헤드 토출 특성 해석 (Performance Analysis of the Industrial Inkjet Printing Head Using 1D Lumped Model)

  • 심원철;김영재;박창성;유영석;정재우;오용수;박성준
    • 한국정밀공학회지
    • /
    • 제24권11호
    • /
    • pp.101-107
    • /
    • 2007
  • Jettability analysis using one-dimensional(1D) lumped parameter model has been investigated to design the industrial inkjet head with proper drop velocity and drop volume. By simplifying the inkjet head system into an equivalent electrical circuit, lumped model has been developed. Performance of the lumped model is verified by the comparison between measured results of droplet velocity and ejection volume and predicted value. Also, the jetting performance of an inkjet head is characterized by varying the design parameter and driving condition. As a result, simulation results shows good agreement with the experimentally measured value. The developed lumped model enables to easily understand the effect of dimension change and predict the jetting performance.

용접 잔류응력 해석을 위한 Heat Input Model 개발 (Modeling of Welding Heat Input for Residual Stress Analysis)

  • 심용래;이성근
    • Journal of Welding and Joining
    • /
    • 제11권3호
    • /
    • pp.34-47
    • /
    • 1993
  • 용접에서 발생하는 열응력 및 잔류응력을 해석하기 위한 유한요소용 모델을 개발하였다. 여러 가 지 변수의 연구를 통하여 Ramp heat input function과 Lumped모델을 제시하였다. 용접부에 열입 력을 점차적으로 주기 위하여 Ramp heat input을 이용하였으며 Ramp input을 통하여 이차원 모 델에서의 이동열원의 영향을 고려하였고 실험치와 비교에서 최적 ramp시간을 결정하였다. 다층용 접에서는 용접 pass 에 비례하여 계산시간이 증가한다. 따라서 후판용접의 잔류응력계산에는 막 대한 계산시간이 필요하며 이를 줄이기 위하여 Lumped 모델을 개발하였다. 이 Lumped모델에서 는 각 용접층에 들어있는 용접 pass들을 하나의 lumped pass으로 이용하였으며 각 pass를 따로 계산한 모델 및 시험치와의 비교를 통하여 최적 lumped technique을 제시하였다. *****Finite element models were developed for thermal and residual stress analysis for the specific welding problems. They were used to evaluate the effectiveness of the various welding heat input models, such as ramp heat input function and lumped pass models. Through the parametric studies, thermal-mechanical modeling sensitivity to the ramp function and lumping techniques was determined by comparing the predicted results with experimental data. The kinetics for residual stress formation during welding can be developed by iteration of various proposed mechanisms in the parametric study. A ramp heat input function was developed to gradually apply the heat flux with variable amplitude to the model. This model was used to avoid numerical convergence problems due to an instantaneous increase in temperature near the fusion zone. Additionally, it enables the model to include the effect of a moving arc in a two-dimensional plane. The ramp function takes into account the variation in the out of plane energy flow in a 2-D model as the arc approaches, travels across, and departs from each plane under investigation. A lumped pass model was developed to reduce the computation cost in the analysis of multipass welds. Several weld passes were assumed as one lumped pass in this model. Recommendations were provided about ramp lumping techniques and the optimum number of weld passes that can be combined into a single thermal input.

  • PDF

Experimental Validation of Two Simulation Models for Two-Phase Loop Thermosyphons

  • Rhi, Seok-Ho
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • 제11권4호
    • /
    • pp.159-169
    • /
    • 2003
  • Five two-phase closed loop thermosyphons (TLTs) specially designed and constructed for the present study are one small scale loop, two medium scale loops (MSLI and MSLII) and two large scale loops (LSLI and LSLII). Two simulation models based on thermal resistance network, lumped and sectorial, are presented. In the Lumped model, the evaporator section is dealt as one lumped boiling section. Whereas, in the Sectorial model, all possible phenomena which would occur in the evaporator section due to the two-phase boiling process are considered in detail. Flow regimes, the flow transitions between flow regimes and other two-phase parameters involved in two-phase flows are carefully analyzed. In the present study, the results of two different simulation models are compared with experimental results. The comparisons showed that the simulation results by the Lumped model and by the Sectorial model did not show any partiality for the model used for the simulation. The simulation results according to the correlations show the various results in the large different range.

업데이트된 집중질량스틱모델과 진동대실험 지진응답 비교 (Comparison of Seismic Responses of Updated Lumped-Mass Stick Model and Shaking Table Test Results)

  • 선휘창;홍상현;노화성
    • 한국지진공학회논문집
    • /
    • 제23권4호
    • /
    • pp.231-238
    • /
    • 2019
  • A conventional lumped-mass stick model is based on the tributary area method to determine the masses lumped at each node and used in earthquake engineering due to its simplicity in the modeling of structures. However the natural frequencies of the conventional model are normally not identical to those of the actual structure. To solve this problem, recently an updated lumped-mass stick model is developed to provide the natural frequencies identical to actual structure. The present study is to investigate the seismic response accuracy of the updated lumped-mass stick model, comparing with the response results of the shaking table test. For the test, a small size four-story steel frame structure is prepared and tested on shaking table applying five earthquake ground motions. From the comparison with shaking table test results, the updated model shows an average error of 3.65% in the peak displacement response and 9.68% in the peak acceleration response. On the other hand, the conventional model shows an average error of 5.15% and 27.41% for each response.

LUMPED PARAMETER MODELS OF CARDIOVASCULAR CIRCULATION IN NORMAL AND ARRHYTHMIA CASES

  • Jung, Eun-Ok;Lee, Wan-Ho
    • 대한수학회지
    • /
    • 제43권4호
    • /
    • pp.885-897
    • /
    • 2006
  • A new mathematical model of pumping heart coupled to lumped compartments of blood circulation is presented. This lumped pulsatile cardiovascular model consists of eight compartments of the body that include pumping heart, the systemic circulation, and the pulmonary circulation. The governing equations for the pressure and volume in each vascular compartment are derived from the following equations: Ohm's law, conservation of volume, and the definition of compliances. The pumping heart is modeled by the time-dependent linear curves of compliances in the heart. We show that the numerical results in normal case are in agreement with corresponding data found in the literature. We extend the developed lumped model of circulation in normal case into a specific model for arrhythmia. These models provide valuable tools in examining and understanding cardiovascular diseases.

댐의 시간영역 지진응답 해석을 위한 호소의 집중변수모델 (Lumped Parameter Model of Transmitting Boundary for the Time Domain Analysis of Dam-Reservoir Systems)

  • 김재관
    • 한국지진공학회:학술대회논문집
    • /
    • 한국지진공학회 2000년도 추계 학술발표회 논문집 Proceedings of EESK Conference-Fall 2000
    • /
    • pp.143-150
    • /
    • 2000
  • A physical lumped parameter model is proposed for the time domain analysis of dam-reservoir system. The exact solution of transmitting boundary is derived for a semi-infinite 2-D reservoir of constant depth. The characteristics of the solution are examined in both frequency and the domains. Mass and damping coefficient are obtained from asymptotic behavior of the frequency domain solution. Further refinement to the lumped model is made by approximating the kernel function of the convolution integral in the exact solution. Finally a new physical lumped parameter model is proposed that consists of two masses, a spring and two dampers for each mode. It is demonstrated that new lumped parameter model of transmitting boundary can give excellent results.

  • PDF

Lumped Capacitance 방법을 이용한 휜-관 열교환기의 정량적 국소 대류 열전달 해석을 위한 실험적 연구 (An Experimental Study on Quantitative Interpretation of Local Convective Heat Transfer for the Fin and Tube Heat Exchanger Using Lumped Capacitance Method)

  • 김예용;김귀순;정규하
    • 대한기계학회논문집B
    • /
    • 제25권2호
    • /
    • pp.205-215
    • /
    • 2001
  • An experimental study has been performed to investigate the heat transfer characteristics of fin and tube heat exchanger. The existing transient and steady methods are very difficult to apply for the measurements of heat transfer coefficients of a thin heat transfer model. In this study the lumped capacitance method was adopted. The heat transfer coefficients were measured by using the lumped capacitance method based on the liquid crystal thermography. The method is validated through impinging jet and flat plate flow experiments. The two experiments showed that the results of the lumped capacitance method with polycarbonate model showed very good agreements with those of the transient method with acryl model. The lumped capacitance method showed similar results regardless of the thickness of polycarbonate model. The method was also applied for the heat transfer coefficient measurements of a fin and tube heat exchanger. The quantitative heat transfer coefficients of the plate fin were successfully obtained. As the frontal velocity increased, the heat transfer coefficients were increased, but the color-band shape showed similar patterns regardless of frontal velocity.

열 잉크젯 프린트헤드의 채널간 간섭현상의 모델링 (Modeling of Crosstalk Behaviors in Thermal Inkjet Print Heads)

  • 이유섭;손동기;김민수;국건
    • 대한기계학회논문집B
    • /
    • 제31권2호
    • /
    • pp.141-150
    • /
    • 2007
  • This paper presents a lumped model to predict crosstalk characteristics of thermally driven inkjet print heads. Using the lumped R-C model, heating characteristics of the head are predicted to be in agreement with IR temperature measurements. The inter-channel crosstalk is simulated using the lumped R-L network. The values of viscous flow resistance, R and flow inertance, L of connecting channels are adjusted to accord with the 3-D numerical simulation results of three adjacent jets. The crosstalk behaviors of a back shooter head as well as a top shooter head have been investigated. Predictions of the proposed lumped model on the meniscus oscillations are consistent with numerical simulation results. Comparison of the lumped model with experimental results identifies that abnormal two-drop ejection phenomena are related to the increased meniscus oscillations because of the more severe crosstalk effects at higher printing speeds. The degree of crosstalk has been quantified using cross-correlations between neighboring channels and a critical channel dimension for acceptable crosstalk has been proposed and validated with the numerical simulations. Our model can be used as a design tool for a better design of thermal inkjet print heads to minimize crosstalk effects.

성층화 열용량 모델을 이용한 VAV 시스템 급기 제어 시뮬레이션 (Simulation of Supply Air Control in a VAV System Using a Stratified Lumped Thermal Model)

  • 문정우;김서영;김원년;조형희
    • 설비공학논문집
    • /
    • 제12권7호
    • /
    • pp.632-641
    • /
    • 2000
  • The present study concerns the simulation of supply-air control in a variable air volume (VAV) system. A stratified lumped thermal model (multi-zone model) is suggested to predict local thermal response of an air-conditioned space. The effects of various thermal parameters such as the cooling system capacity, the thermal mass of air-conditioned space, the time delay of thermal effect, and the building envelope heat transmission are investigated in detail. Further, the influence of control parameters, PI control factor and the sensor location on a VAV system is quantitatively delineated. The results obtained show that the previous homogeneous lumped thermal model (1-zone model) may predict a significantly different thermal response in the air-conditioned space according to the sensor location.

  • PDF

Performance Analysis of an Industrial Inkjet Printing Head Using the 1D Lumped Model

  • Sim, Won-Chul;Park, Sung-Jun;Joung, Jae-Woo
    • International Journal of Precision Engineering and Manufacturing
    • /
    • 제9권2호
    • /
    • pp.50-53
    • /
    • 2008
  • A design approach using a one-dimensional (1D) lumped model was studied and applied to an industrial inkjet printing head design for micro patterning on printed circuit boards. For an accurate analysis, a three-dimensional piezoelectric-driven actuator model was analyzed and its jetting characteristics were applied to 1Danalysis model. The performance of the 1D lumped model was verified by comparing measured and simulated results. The developed 1D model helped to optimize the design and configuration of the inkjet head and could be implemented in the design of multi-nozzle inkjet printing heads to improve the jetting frequency and minimize crosstalk.