• 제목/요약/키워드: Luminous flux

검색결과 97건 처리시간 0.023초

사용자 요구 조도 보장 에너지 효율적 실내 조명 시스템 조명 방향 및 광속 제어 기법 (A Lighting direction and Luminous Flux Control for Energy-efficiency under Illuminance Requirements in Indoor Lighting Systems)

  • 김훈
    • 조명전기설비학회논문지
    • /
    • 제29권5호
    • /
    • pp.19-25
    • /
    • 2015
  • The management of energy resources for efficient utilization of the energy resources while reducing the system costs is a critical technical issue. Among many kinds of the energy resource management, the energy reduction for indoor lighting systems is getting much concern as a large portion of energy consumption has been made for indoor lightings. In this paper, an energy-efficient lighting control scheme for indoor lighting systems in order to reduce the energy consumption by controlling the luminous flux and the lighting direction under the illuminance constraints is proposed. With the use of the user location information for the luminaire which is closely located to the user, the proposed scheme firstly sets the light direction of the luminaire to be aligned to the user location. Then, an optimization problem to find the luminous flux of each luminaire is formulated in order to minimize the luminous flux sum of the luminaires with the constraints for the dynamic ragne of the luminous flux, and the light flux for each luminaire is determined by the solution of the problem. Simulation results show that the proposed scheme outperforms the luminaire control scheme with only the luminous flux control in the evaluation of satisfaction of the required illuminance level.

형광등 Positive column에 대한 자장인가 효과 (Magnetic field effect on the positive column of fluorescent lamp)

  • 지철근;김창종
    • 전기의세계
    • /
    • 제31권3호
    • /
    • pp.197-203
    • /
    • 1982
  • The effects on the characteristics of 20-W fluorescent lamp were studied when applying magnetic field to its positive column. First, when the direction of the magnetic field is axial, i.e., along the lamp, if the magnitude of the field is stronger than the critical field, lamp voltage is increased, lamp current decreased, luminous flux increased, starting voltage decreased, as increasing the applied magnetic field. At the magnetic flux density is 130 gauss, luminous flux is increased to about 6 percents and starting voltage is increased to about 45 percents. Second, when the direction of the magnetic field is transverse to the lamp axis, as increasing the applied magnetic field, lamp voltage is increased, lamp current decreased, luminous flux increased and starting voltage is nearly constant, but the rates of increase or decrease of this case is different from those of the first. At the magnetic flux density is 300 gauss, luminous flux is increased about 45 percents. In both cases, electric power dissipated by lamps is the same as that of the lamp which magnetic field is not applied to.

  • PDF

확산형 LED램프와 백열램프의 각도별 광속에 관한 비교연구 (A Comparative Study on the Luminous Flux by Degree of Non-directional LED Lamps and Incandescent lamp)

  • 박창용;서정현
    • 조명전기설비학회논문지
    • /
    • 제28권8호
    • /
    • pp.32-39
    • /
    • 2014
  • In general, non-directional LED lamps including high transmittance cover are more advantageous than directional LED lamps, which are efficient enough to improve luminous efficacy and obtain certification, allowing wide manufacture, sale, and distribution. Although KS C 7651(Self-ballasted LED lamps-Safety and performance requirements) was revised in July 2013, however, many companies are having a lot of difficulties in keeping the certification and product development for the lack of the photometric analysis for non-directional LED lamps. In this paper, through the measurement of the angular distribution of luminous flux of incandescent lamp and non-directional LED lamps, we examined the reasonability of non-directional LED lamps' standards as suggested in KS C 7651. According to the results, even if non-directional LED lamps satisfy KS C 7651, when compared to an incandescent lamp, they showed less diffusive than the incandescent lamp and the distribution of the luminous flux depending on the angle fluctuated greatly even among LED lamps. Judging by the result, the current standard of the non-directional LED lamps, KS C 7651, has been comprehended that the angular distribution of the luminous flux needs to be presented after being much more thoroughly standardized.

전자장내 플라즈마의 전류 및 광속에 대한 변화식 유도 (The Derivation of Variation Equations for the Discharge Current and the Luminous Flux of Flourescent Lamp Plasma in a Transverse Magnetic Field.)

  • 지철근;여인선;박왕렬
    • 대한전기학회논문지
    • /
    • 제34권10호
    • /
    • pp.384-388
    • /
    • 1985
  • In this paper, an attempt is made to derive the variation equatios of the discharge current and the luminous flux for flourescent lamp subjected to a transverse magnetic field. As the field increases, so do the electric field, the electron temperature, and the luminous flux, while the current decreases. The theory is in a reasonable agreement with the experimental results, taking account of many approximations and restrictions.

  • PDF

보정계수 산출에 의한 신광원용 표준램프 광속의 검증 (The verification of Luminous flux of Reference illuminant for New light source by the calculated correction factor)

  • 황명근;신상욱;이진우
    • 전기학회논문지
    • /
    • 제58권2호
    • /
    • pp.369-372
    • /
    • 2009
  • When measuring the luminous flux of a light source at the integrating sphere photometer, it can know the luminous flux to compare the standard lamp with the specimen lamp at the same location. But in case of PLS(plasma lighting system, microwave discharged lamp), that two lamps are cannot be the same location. If the reference illuminant and specimen lamp are cannot measure identical location, we should measure the variation of the luminous flux. For the outcome we can turn out a correction factor to revise and reflect it. But the better way is calibrate the specimen lamp locate the identical location of reference illuminant measured. In this thesis, we've test to find the correction factor for consider that change the measuring location. And it turns out the correction factor. From this, it presents the result to make a select for the reference illuminant which is against the illuminant type for newly produce.

광원주위의 3차원 광선속 측정 및 평가 (Measurement and Characterization of Three Dimensional Luminous Flux)

  • 최종운;유문종
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제52권7호
    • /
    • pp.314-318
    • /
    • 2003
  • This paper describes the construction, measurement, and characterization of an instrument for the distribution of luminous flux. This is done by measuring the flux around a light source while a detector and a source is rotating, and integrating it over an entire imaginary surface surrounding the source. We make a gonio radiometer to realize the scales of total luminous flux and geometrically integrate to get total spectral flux from standards of irradiance and illuminance. The uncertainties of a total flux in the gonioradiometry are 1.3%, and 0.4% below the standard lamps of NIST and NIM for each other.

Plasma Jet의 동축평행 자계에 의한 영향에 관한 연구 ( 1 ) (A Study on the Influence of Coaxial Parallel Magnetic Field upon Plasma Jet)

  • 전춘생
    • 전기의세계
    • /
    • 제22권2호
    • /
    • pp.57-69
    • /
    • 1973
  • The aim of this study was to investigate the behaviors of plasma jet under coaxial magnetic field in paralled with it for controlling optical characteristics and input power of plasma jet without impurity and instability of arc plasma column. Because the discharge characteristics of plasma jet were so distinctively different according to the existence or non-existence of magnetic field, the input power, luminous intensity of plasma jet and thermal efficiency were comparatively studied in respect of such variables as arc current, gap of electrode, quantity of argon flow, magnetic flux density, diameter and length of nozzle, with the use of several materials which were different in diameter and length of nozzel. The results were as follows; 1) The voltage tends to show a drooping characteristic at law current and then rises gradually. The luminous intensity of plasma jet increases exponentially with arc current. 2) Arc voltage increases and luminous intensity tends to decrease gradually as gap of electrode increases. 3) Arc voltage and luminous intensity tends to decrease gradually as gap of electrode increases. 3) Arc voltage and luminous intensity increase in accordance with the quantity of argon flow. 4) At first step, arc voltage increases to maximum value with the growth of flux density and then tends to show a gradual decrease. Luminous intensity decreases with the growth flux density. 5) Arc voltage decreases as the constriction length of nozzle increases, maximum decrease is shown at the constriction length of 20(mm) and it increases beyond that value. The luminous intensity decreases as the constriction length grows. 6) Arc voltage and luminous in tensity increase with the growth of diameters of nozzle. 7) Thermal efficiency has values between 50% and 75%, being influenced by arc current, the quantity of argon flow, flux density, the length of electrode gap and the constriction length of nozzle.

  • PDF

전광선속 측정을 위한 고니오광도계 제작 (A gonioradiometer for total flux measurements)

  • 김용완;신동주;이인원;최종운
    • 한국광학회지
    • /
    • 제15권2호
    • /
    • pp.137-141
    • /
    • 2004
  • 조도단위계로부터 전광선속의 단위계를 실현하기 위해서 전광선속 측정장치를 제작하여 광도측정의 단위계를 복사선 측정의 기준으로 변환하였다. 제작된 전광선속 측정장치는 광원으로부터 전 방향으로 발산하는 광속을 측정하고, 광원 주위의 가상구면을 적분함으로서 전광선속을 측정하였다. 광검출기로 LMT사의 조명도계를 사용하여 광원의 중심과 조명도 기준면까지의 거리가 약 1.693 m인 가상의 구면의 조명도를 측정하였다. 제작된 고니오광도계의 전광선속은 95% 신뢰수준에서 측정불확도는 1%이다.

Design and Analysis of Diffractive Grating Imprinted Light-guide Plate for LCD Illumination

  • Choi, Hwan-Young;Park, Young-Pil
    • Journal of Information Display
    • /
    • 제5권1호
    • /
    • pp.7-15
    • /
    • 2004
  • A highly simplified backlight unit mainly composed of diffractive grating in sub-micron order imprinted light-guide plate (LGP) is proposed for edge-lit backlight unit. Optical characteristics of the imprinted LGP are examined by RCWA and the performance is verified through Monte Carlo simulation. Results show that the diffraction efficiency, luminous flux and its uniformity over the area are significantly affected by the angle of incident ray. Consequently couples of design considerations are additionally proposed to enhance luminous flux. In terms of peak luminance and out-coupling luminous flux, the experimental results are agreed well with the performance simulation. Finally, compared with optical characteristics of conventional backlight unit, we could conclude that the proposed simplified backlight unit made of diffractive grating imprinted light-guide plate is a good substitute for the conventional backlight unit.

적분구를 이용한 PLS 광속측정의 보정계수 산출 및 적용 (Calculation of correction factor in PLS luminous flux measurement with integrating sphere)

  • 이정욱;박경훈;유재규
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2006년도 춘계학술대회 논문집
    • /
    • pp.13-15
    • /
    • 2006
  • This paper describes the problem generated in PLS luminous flux measurement with integrating sphere. In RS case, we don't use the center position of the sphere but side position for flux test The difference of the lamp position makes the luminous flux difference of same light source. We confirmed the phenomenon with three other kinds of lamps and ensured the repeatability and reliability of this work at two laboratories. finally, the correction factor which should be applied for the PLS test at Side position was calculated.

  • PDF