• 제목/요약/키워드: Luminous color

검색결과 163건 처리시간 0.027초

치과 진료실의 조명에 관한 실태 조사연구 (A STUDY ON THE ILLUMINATION OF DENTAL CLINIC)

  • 최종인;김유리;동진근
    • 대한치과보철학회지
    • /
    • 제44권4호
    • /
    • pp.374-382
    • /
    • 2006
  • Purpose: This study was designed to investigate the present conditions of illumination techniques in dental clinics in order to contribute improvement of operating environment. This study also aimed exploring qualitative and quantitative luminous intensity required for color temperature in dental clinic illumination, which was a critical part of esthetic dentistry. Materials and methods: A total of forty-eight local dental clinics were selected for sampling a) luminous intensity, and b) color temperature. The author measured the luminous intensity and the color temperature with lux meter and color meter respectively between 12pm and 2pm. The dental unit chair placed in the general operation positions were kept the distance 60 cm then all dental units were measured three times and averaged. The author measured the luminous intensity and color temperature with both common dental operating light and then without operating light in different office environments. The study was conducted under three conditions: 1 artificial illumination in clear day light 2. artificial illumination in cloudy day light, and 3. artificial illumination alone. Results : The results obtained were as follows. 1. The average luminous intensity in dental clinic lighting was 425 lux which was not sufficient to produce the optimal shade of the patient's teeth. Furthermore, the average luminous intensity even in full operating lighting was 9532 lux which fell short of the required level of 10,000 lux. 2. The average color temperature of all dental clinics surveyed was 5169 K which met the optimal range. However, only 33.3% fell in the correct region between 5,000-5,500 K as 25% were over 5,500 K and 41.6% were below 5,000 K. As a result, 66.7% were under insufficient color temperature conditions. 3. The dental unit chair placed next to a window, hence exposure to natural lighting, had significantly higher luminous intensity and color temperature compared to the dental unit chair which didn't have a window or natural lighting. 4. The data analysis revealed that only 6.3% of the dental clinic were met the standard of the average luminous intensity and color temperature.

직물색의 지각에 미치는 광원의 영향 (The Influence of Luminous Source Affecting on the Perception of Textile Color)

  • 최나영;양리나;이종숙
    • 복식문화연구
    • /
    • 제15권2호
    • /
    • pp.214-220
    • /
    • 2007
  • The purpose of this study is to derive the use of the luminous source corresponding to the intention and contribute to product display by visually evaluating the relations between luminous source and colors, analyzing and reviewing the subjective perceptions depending on the luminous source, and clarifying the colors of artificial luminous source that look close to natural lights by each color. Hence, the researcher objectified the subjective evaluation for which they used sensory evaluation method with four colors of luminous sources(natural colors, 2800K, 4200K, and 6500K) and five colors of textiles(purple, blue, green, yellow, and red) by quantifying the evaluation. As a result, we could obtain the conclusion as follows. As for the temperature of textile colors under artificial luminous sources that appeared most close to the colors of textiles under natural luminous sources, 6500K was most frequent, and the temperature of the luminous sources that appeared most different was 2800K. However, as there were also 4200K colors that looked most close to the textile colors under natural light source, it was observed that the temperature differs depending on the textile colors. In addition, less glossy textiles exhibited more visual changes by luminous source colors than comparatively more glossy textiles, and it was observed that the most influenced color was purple, as purple has shown the largest difference among colors.

  • PDF

A Study on the Control of Luminous Color in Gas Discharge Tubes

  • Lee, Jong-Chan;Her, In-Sung;Park, Yong-Sung;Masaharu Aono;Park, Dae-Hee
    • KIEE International Transactions on Electrophysics and Applications
    • /
    • 제4C권1호
    • /
    • pp.5-9
    • /
    • 2004
  • In this paper, pulsed discharge is used to control the luminous color in gas discharge tubes. The luminous color of the positive column in gas discharge tubes filled with Hg-Ar-Ne (1: 9, 60[Torr]) and having no phosphor material, varies from red to blue emitted by the Ne and Hg from the pulsed discharge. With changing of pulse-width and frequency, the electron temperature in the transient period affects changes to the residual ion and metastable atom densities. The first metastable atoms containing energy levels of about 16.6 [eV]have a very high probability that a collision will result in the ionization potential of Ar being 15.8 [eV]. The change of locus in the CIE chromaticity diagram with increasing pulse-width and frequency approves the variation of luminous color.

Research about evaluating the spectrum of WOLED

  • Lu, Lili;Chen, Wenbin;Shao, Wanli
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2006년도 6th International Meeting on Information Display
    • /
    • pp.961-965
    • /
    • 2006
  • White organic LED spectrum for lighting and displaying should be designed for high luminous efficiency as well as good chromaticity coordinate, pleasant correlated color temperature and color rendering. A program based on Matlab was made to make these calculations convenient. The chromaticity coordinate and luminous efficiency was calculated according to the CIE 1931 colorimetric system, while the correlated color temperature(CCT) was calculated based on CIE 1960 UCS diagram. The color rendering characteristics were evaluated according to the CIE Color Rendering Index (CRI), using Ra, Ri and ${\bigtriangleup}E$ from the 14 color samples defined in CIE13.3.

  • PDF

Selection of a Remote Phosphor Configuration to Enhance the Color Quality of White LEDs

  • Anh, Nguyen Doan Quoc;Le, Phan Xuan;Lee, Hsiao-Yi
    • Current Optics and Photonics
    • /
    • 제3권1호
    • /
    • pp.78-85
    • /
    • 2019
  • The remote phosphor structure has been proven to bear greater luminous efficiency than both the conformal phosphor and in-cup phosphor structures; however, controlling its color quality is much more challenging. To solve this dilemma, various researchers have proposed dual-layer phosphor and triple-layer phosphor configuration as techniques to enhance the display brightness of white LEDs (WLEDs). Likewise, this study picked one of these configurations to utilize in multichip WLEDs with five distinct color temperatures in the range from 5600 to 8500 K, for the purpose of improving the optical properties of WLEDs, such as color rendering index (CRI), color quality scale (CQS), luminous efficacy (LE), and chromatic homogeneity. According to the results of this research, the triple-layer phosphor configuration has superior performance compared to other configurations in terms of CRI, CQS, and LE, and yields higher chromatic stability for WLEDs.

오징어 채낚기 낚시의 야광이 어획에 미치는 영향 (Influence of luminous jig to catching of squid jigging in the Korean waters)

  • 류경진;김형석
    • 수산해양기술연구
    • /
    • 제55권4호
    • /
    • pp.303-309
    • /
    • 2019
  • This study identified the characteristics of squid jig in korea waters by investigating the effect of color and luminous performance of squid jig on the catch of squid and experimenting the result of jig according to green jig or white jig, and whether using luminous or not were tested in the sea to improve the jig of squid jigging. For this purpose, a total of 13 sea experiments were conducted using T/S No. 2 Galmaegi. As a result, 341 squids were caught. Among them, 221 squids were caught by green jig (64.8%), 64 squids were caught by white jig (18.8%), 41 squids were caught by green luminous jig (13.8%), and nine squids were caught by white luminous jig (2.6%). The green jig commonly used in jigging vessel was most effective, and luminous jig was less effective than that non-luminous jig. The squids caught were Japanese flying squid (Todarodes pacificus), swordtip squid (Loligo edulis) and spear squid (Loligo bleekeri), and no significant characteristics were found according to the color of jig and the presence of luminous.

치과 기공실의 조명에 관한 실태 조사 연구 (A study of illumination of dental laboratories)

  • 이효정;최종인;김성숙;동진근
    • 구강회복응용과학지
    • /
    • 제30권4호
    • /
    • pp.289-298
    • /
    • 2014
  • 목적: 본 연구는 치과 기공실의 조명이 심미 보철을 위한 색조의 분별과 조화, 재현에 적당한지 알아보기 위한 실태 조사이다. 연구 재료 및 방법: 48곳의 치과 기공실을 대상으로 lux meter와 color meter를 이용하여 포세린 작업대(porcelain table) 상판 중심의 조도와 색온도를 측정 하였다. 각각의 기공실을 자연광(day light)과 인공조명(artificial illumination)이 있는 오후 12시 - 2시 사이와 인공조명 만이 있는 오후 7시 - 10시 사이, 2차례 측정하였고, 맑은 날과 흐린 날로 구분하였다. 결과: 1. 전체 기공실의 평균 조도는 1871 lx이었고, 67%의 기공실이 1600 lx를 넘겨 색과 관련한 작업을 하기에 적합한 조도를 갖추었으나 33%의 기공실은 이에 미치지 못하였다. 2. 전체 기공실의 평균 색온도는 6506 K로 색과 관련한 작업을 하기에 부적절하였다. 적정 색온도인 5000 - 5500 K를 만족하는 기공실은 없었다. 3. 전체 기공실의 낮과 밤의 조도(P = 0.73) 및 맑은 날과 흐린 날의 조도(P = 0.89)와 낮과 밤의 색온도(P = 0.17) 및 맑은 날과 흐린 날의 색온도(P = 0.51)는 유의한 차이를 보이지 않았다. 결론: 본 연구에서 조사된 치과 기공실의 조명은 색과 관련한 작업을 하기에 부적절한 경우가 많았다.

Ar Gas 첨가에 따른 칼라 플라즈마 디스플레이 패널의 효율 향상 (The Luminous Efficiency Improvement of Color AC Plasma Display Panel by adding Ar Gas)

  • 신재화;최훈영;이석현
    • 전기학회논문지P
    • /
    • 제51권3호
    • /
    • pp.132-136
    • /
    • 2002
  • In this study, we analyzed the luminous efficiencies of Ne-Xe-Ar and He-Ne-Xe-Ar mixing gas in compared with those of Ne-Xe and He-Ne-Xe mixing gas to improve luminous efficiency by adding a small amount of Ar gas. At the Xe 4%, the brightness of Ne-Xe and He-Ne-Xe mixing gas is higher than others. As the Xe % increases, power consumption decreases. Thus, in the Ne-Xe and He-Ne-Xe mixing gas of Xe 4%, we obtained maxium luminous efficiency. The Ar concentration is varied from 0.1% to 0.7% in this study. The luminous efficiency of the Ne-Xe(4%) mixing gas is improved to 1.16 and 1.13 lm/W by adding an Ar concentration of 0.4% and 0.5%, respectively. The luminous efficiency of the He-Ne-Xe(4%) (He : Ne = 7 : 3) mixing gas is considerably improved by adding an Ar concentration of above 0.3%. The maximum luminous efficiency of this mixing gas is 1.38 lm/W at the condition of adding an Ar concentration of 0.5%.

Ar Gas 첨가에 따른 칼라 플라즈마 디스플레이 패널의 효율 향상 (Color AC Plasma Display Panel of Luminous Efficiency Improvement by adding Ar Gas)

  • 최훈영;민병국;이석현
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 추계학술대회 논문집 학회본부 C
    • /
    • pp.919-921
    • /
    • 1998
  • In Color AC Plasma Display Panel(PDP). Low luminous efficiency is a major problem. We measured luminous efficiency of PDP as a function of the Ar mixing ratio. Our results show that efficiency has improved by $5{\sim}10%$ at the condition of 0.5% Ar mixing ratio, compared with Ne-Xe(4%) or He-Ne-Xe(4%) (He:Ne = 7:3) gas.

  • PDF

SMD형 Y/G/W HB LED의 광특성 비교분식 (Optic Characteristics Comparison and Analysis of SMD Type Y/G/W HB LED)

  • 황명근;허창수;서유진
    • 조명전기설비학회논문지
    • /
    • 제18권4호
    • /
    • pp.15-21
    • /
    • 2004
  • 광속구(integrating sphere photometer), 분광기(monochromator)등을 이용하여 노랑색(Y), 녹색(G), 백색(W)의 SMD(surface mounted device)형태의 HB LED(high brightness light emitting diode)에 대한 광속(luminous flux, LF), 상관 색온도(correlated color temperature, CCT), CIE 색도좌표(chromaticity coordinate CC)등 광특성을 실험하여 그 결과치를 비교 분석하였고, 백색 LED에 대해서는 연색지수를 고찰하였다.