• Title/Summary/Keyword: Luminance ratio

Search Result 190, Processing Time 0.026 seconds

Preliminary Field Test on Daylighting Performance of Perpendicular Light Pipe System (수직형 라이트파이프의 채광성능에 관한 예비평가)

  • Shin, Hae Mi;Park, Hoon;Kim, Jeong Tai
    • KIEAE Journal
    • /
    • v.8 no.1
    • /
    • pp.53-60
    • /
    • 2008
  • The daylighting affects on the human biological cycles and physiological alterations. Daylighting is also an important element in visual comfort and it sometimes influences the quality of vision. Therefore the absence of natural light during the day brings contradictory result. To solve the problems of natural light lack and provide sufficient daylight in interior spaces, it might be necessary to apply some daylighting systems. One of these systems, light pipe system, which is simple, cheep and easily constructed, is very useful to apply for small buildings. The light pipe is simple means of directing daylighting (diffuse and direct lighting)into interior space. In order to application of light pipe system in Korea, it is necessary to optical data of light pipe system. This study aims to evaluate preliminary experiment of the daylighting environment of light pipe system. Light pipe system, that aspect ratio is 1:2(diameter and length), was installed in a windowless mock-up with $27m^2$. The mock-up model was constructed as a prototype of Korean office surface. Illuminance was measured with a Topcon IM-5 Luxmeter to evaluate the distribution of the illuminance on a floor. The indoor and outdoor illuminance and the internal/external illuminance ratio are compared to discuss with in the graphs. Luminance was measured with Radiant imaging Promertric 1400 that is digital photometer to evaluate the distribution of luminance on interior surface. The contrast of luminance is discussed with table and graphs.

Effects of Cell Structure on the Contrast Ratio in AC PDP

  • Park, Chung-Hoo;Moon, Young-Seop;Lee, Sung-Hyun;Kim, Goon-Ho;Kim, Dong-Hyun;Lee, Ho-Jun
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2002.08a
    • /
    • pp.613-616
    • /
    • 2002
  • Luminance and contrast ratio is one of the most fundamental and important parameters of plasma display panel. Understanding the effects of cell design parameters on the display and background luminance is inevitable for improving the contrast ratio. We report the experimental results on the relationships between cell parameters and contrast ratio of the ac PDP driven by ADS scheme. It was found that the contrast ratio is the most significantly affected by rib height and optimum range of the rib height simultaneously affects the facing discharge during the reset periods, diffusion loss of plasma and shadowing of the visible light emitted from phosphor.

  • PDF

Comparison of Safety Level between Driver's Ages by Threshold Zone Luminance Level of Vehicular Traffic Tunnel (터널 경계부 휘도수준에 따른 운전자 연령대별 안전수준 비교)

  • Cho, Won Bum;Jeong, Jun Hwa;Kim, Do Gyeong;Park, Won Il
    • International Journal of Highway Engineering
    • /
    • v.17 no.1
    • /
    • pp.129-142
    • /
    • 2015
  • PURPOSES : The purpose of this study is to suggest a basis for setting appropriate safety goals specifically related to the threshold zone luminance in a vehicular traffic tunnel. METHODS : In the test, drivers were divided into two groups. One group consisted of all drivers (average drivers) group with an age ratio of drivers holding domestic driver's license and driver group by age to produce threshold zone luminance in the tunnel. The threshold zone luminance produced as a result was used to analyze how it affects the safety level of each driver group and provide a basis for setting an appropriate safety criterion that can be used to determine threshold zone luminance. We used test equipment, test conditions, and ananalysis of threshold zone luminance identical to that reported by ChoandJung(2014) but the values of adaptation luminance in our analys is were expanded to range from100 to $10,000cd/m^2$. RESULTS : Adaptation luminance and threshold zone luminance are found to be related by a quadratic function. The threshold zone luminance needed by older drivers to ensure a certain safety level is significantly higher than that for drivers of other age brackets when adaptation luminance increases. 56% of older drivers are at an increased risk of an accident at the same luminance for which the safety level of average drivers is 75%. The safety level that can be achieved for older drivers increases to above 60% when threshold zone luminance level is set with the goal of attaining a safety level of more than 85% for average drivers. The safety level that can be attained for average drivers is above 90% when the threshold zone luminance is high enough to ensure over 75% in the safety level of older drivers. Results of this study are applicable to highways and others whose designed speed is 100 km/h. CONCLUSIONS : Threshold zone luminance determined on the basis of drivers having average visual ability is of limited value as a performance standard for ensuring the safety of older drivers. Hence, safety level for older drivers should be considered separately from safety levels for drivers with an average ability to avoid risk. Upward adjustment of older drivers' safety level in the process of determining appropriate threshold zone luminance in a vehicular traffic tunnel may bring both tangible and intangible benefit as a result of reducing accidents. However, there is an associated dollar cost arising from installing and operating lights. As a result, the economic impact of these trade-offs should also be considered.

Brightness Function on TV Viewing Condition (TV 시청 조건에서의 Brightness Function)

  • 최성호;김희철;장수욱;김은수;한찬호;송규익
    • Proceedings of the IEEK Conference
    • /
    • 2003.07e
    • /
    • pp.2403-2406
    • /
    • 2003
  • When viewing images, the relative luminance of the surround has a profound impact on the apparent contrast of the image. The dark surround causes the image elements to appear lighter than those viewed in an illuminated surround. For this reason, it is worthwhile to briefly review the general results of brightness sealing under a various viewing condition. Two of the most often cited parers on the topic of brightness scaling are Stevens-stevens and Bartleson-Breneman's function. There are, however, significant differences between the perceptual functions for simple-field and complex-field viewing. In this paper, we research the relationship between Steven's power law and Bartleson-Breneman's function. We present an appropriate brightness perception function due to TV system viewing conditions. Highlight luminance peak and absolute brightness threshold value in various adaptation levels are obtained from the proposed brightness function . Also, the luminance value of black level to produce the same contrast ratio with variety of display highlight luminance peak is obtained from the proposed brightness function.

  • PDF

Luminance Correction for Stereo Images using Histogram Interval Calibration (히스토그램 구간 교정을 이용한 스테레오 영상의 휘도 보정)

  • Kim, Seaho;Kim, Hiseok
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.50 no.12
    • /
    • pp.159-167
    • /
    • 2013
  • In stereo-view system, variations of target camera position or lighting conditions cause discrepancies on the luminance and chrominance components of stereo views. These discrepancies lead to inaccurate frame view prediction and low quality of 3 D video coding. In this paper, an efficient histogram interval calibration method is proposed for stereo-view coding, so as to compensate for the luminance component of target view. First the proposed method is analyzed by the histogram of the target image frame. Then, it divide two sections of histogram of that frame to correct the color discrepancies. Secondly, each section of the target frame is corrected the luminance component by identify the maximum matching region between the reference frame and the target frame. We have verified our proposed histogram matching method in comparison with the other color correction ones. Experimental results show that it can correct better luminance calibration results of PSNR(Peak Signal to Noise Ratio) and has less computation time.

Evaluation of daylighting performance of bar-type mirror reflector system in tunnel (터널 적용 바형식 반사거울시스템의 채광성능 평가)

  • Lee, Beom-Seok;Joo, Jae-Sung;Jeong, In-Young;Kim, Min-Sung
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.14 no.1
    • /
    • pp.93-105
    • /
    • 2012
  • The basic study was preceded for reducing maintenance and power cost of lighting fixture applying daylighting because most of the tunnel lighting depend on the artificial lighting. This study aims to evaluate the daylighting performance of daylighting performance of bar-type mirror reflector system in tunnel. Illuminance and luminance was measured. As a result of horizontal illuminance measurements, it was satisfied in tunnel recommended illuminance (KSA 3703) that total average was 1,170 lx increased 6.5 times more than this system was not used. Also, as a result of evaluating driver's glare on the opposite lane, glare did not occur and the luminance ratio was 3.01 which satisfies the luminance ratio standard 10.

A study on the influence of luminecent center on luminance in SrS:Ce electroluminescent devices (SrS:Ce EL소자에 있어서 발광중심이 휘도에 미치는 영향에 관한 연구)

  • Lee, Sang-tae
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2001.10a
    • /
    • pp.613-616
    • /
    • 2001
  • The effect of codopants on the electroluminescent properties for SrS-Ce based thin films was studied. The active layer was deposited by electron beam with sulfur The wavelength of eletroluminecence shifted with codopants and their concentrations. The intensity ratio of blue to green were found In the CeP-doped device, but the highest total intensity of luminance showed about 850cd/$m^2$ in the CeCl$_3$+KCL-doped device, which indicates that codopants are playing an important role of luminance. At any device, the luminance was the strongest at 0.2 mol% concentration among the concentration studied, suggesting the existence of optimum concentration. By post-annealing Luminance of most devices was improved, but the shift of wavelength was not observed.

  • PDF

A Study on the Improvement of Optical Characteristics for Cellular Phone LGP Considering Replication ratio (전사성을 고려한 휴대폰용 도광판의 광특성 향상에 관한 연구)

  • Do, Y.S.;Kim, J.S.;Hwang, C.J.;Yoon, K.H.
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 2008.05a
    • /
    • pp.269-272
    • /
    • 2008
  • LGP is a key component of LCD back light unit because it determines the brightness and sharpness of display image. Usually, it has optical patterns fabricated on the bottom surface. In the present paper the LiGA-reflow method was applied to fabricate the LGP mold. Furthermore, the optical simulation considering the replication ratio of pattern height was applied to the pattern design. The optical simulation through systematic correction scheme helped find the optimum distribution of pattern density. Finally, the stamper fabricated by this method was installed in the mold and LGP was produced by injection molding. As a result of luminance measurement for the final product, the average luminance and luminance uniformity was measured 3,180 nit and 84%, respectively. Consequently, the mold fabrication method using the LiGA-reflow and optical simulation(CAE) can save the expense and time compared with the existing fabrication methods(laser ablation and chemical etching).

  • PDF

The development of improve the compression ratio through the variance of the luminance component of the intra macroblock (인트라 매크로블록의 휘도성분 분산을 이용한 압축률 향상)

  • Kim, June;Kim, Youngseop
    • Journal of the Semiconductor & Display Technology
    • /
    • v.12 no.1
    • /
    • pp.35-39
    • /
    • 2013
  • H.264/AVC is an authoritative international video coding standard which shows code and efficiency more improved than the existing video standards. Above all, the parameter block mode of H.264/AVC significantly contributes much to high compression efficiency. However, as the occasion demands, users tend to pass while overlooking the part that can produce a little higher compression efficiency. We, taking notice of this point, are designed to bring in much higher compression efficiency by gathering up the overlooked parts. This paper suggests the algorithm that produces efficient performance improvement by using the histogram of luminance in the pixel unit (Macroblock) of respective prediction block and applying specific thresholds. The experimental results proves that the technique proposed by this paper increases the compression efficiency of the existing H.264/AVC algorithm by 0.4% without any increase in the whole encoding time and PSNR complexity.

White LED Local Dimming Backlight for Aggressive Power Saving and Artifact Minimizing

  • Yeo, Dong-Min;Kwon, Yong-Hoon;Kang, Eui-Jeong;Park, Se-Ki;Yang, Byung-Choon;Kim, Gi-Cherl;Jang, Tae-Seok
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2008.10a
    • /
    • pp.1156-1159
    • /
    • 2008
  • Local dimming driving has advantages in reducing power consumption and improving contrast ratio(CR). In an LED backlight unit(BLU), many small LED blocks are implemented in 2-dimmensional space, and luminance of the blocks is controlled by a local dimming algorithm. However, such a BLU can induce various recognizable artifacts. A new novel algorithm is proposed for exact block luminance calculation to correct local dimming artifacts. Also we discuss modified low-gray-level dimming to achieve much aggressive power saving in a local dimming BLU system.

  • PDF