• 제목/요약/키워드: Luminance contrast

검색결과 164건 처리시간 0.031초

저휘도 환경에서 태블릿 PC를 이용한 장시간 독서시 문자대비가 가독성과 피로감에 미치는 영향 (Effect of Luminance Contrast Ratio of Character on Readability and Visual Fatigue during Long-term Reading Using Tablet PC in Low Luminance Environment)

  • 유하늬;아키타 타케시
    • 대한건축학회논문집:구조계
    • /
    • 제35권5호
    • /
    • pp.191-202
    • /
    • 2019
  • This study examines the effect of luminance contrast ratio of character on readability and visual fatigue during an hour-long reading session while using a tablet PC in ambient environments having low luminance limited to $25cd/m^2$. Experiments were conducted with four patterns of the tablet's luminance contrast ratio of characters, namely 1:2.5, 1:4.5, 1:6.5, and 1:8.5, in low ambient luminance of $9cd/m^2$ and $25cd/m^2$. The obtained results show that the characters can be easily read at the luminance contrast ratio of character of 1:8.5 under surface luminance of $25cd/m^2$. Visual fatigue was evaluated through a subjective survey of symptoms. Physical, psychological, and visual fatigue were observed at a surface luminance of $9cd/m^2$, whereas solely visual fatigue was felt at a surface luminance of $25cd/m^2$. By assessing the physical fatigue using the value, it has been found that smaller the luminance contrast ratio of character, greater is the CFF variation rate. Furthermore, readability is poor and visual fatigue can be observed when the surface luminance is lower than the ambient luminance. However, readability can be improved by increasing the luminance contrast ratio of character to a value of 1:8.5. Thus, in low luminance environments, luminance contrast ratio of characters can affect readability and fatigue. Consider providing the full form of "CFF" so that the acronym can be used unambiguously throughout the manuscript.

휘도대비가 가독성에 미치는 영향에 대한 실험 연구 - 화면 크기와 가독량을 고려한 휘도대비 가이드라인 - (An Experimental Study on the Impacts of Luminance Contrast Upon Readability in VDT Environments)

  • 이수진;김진우
    • 대한인간공학회지
    • /
    • 제26권2호
    • /
    • pp.21-33
    • /
    • 2007
  • The study investigates the effects of luminance contrast, which is the contrast between text color and background color, on readability in VDT environments. Our research goals are to prove that the relationship between luminance contrast and readability is not linear and to explore the best luminance contrast level for optimal readability. We conducted two pretests before the main experiment to determine the operational readability and luminance contrast levels. We also conducted a controlled main experiment, in which luminance contrast, reading amount and screen size were tested in terms of its relation with readability. The results of the main experiment indicate that the readability has a non-linear relation with luminance contrast, and the optimal readability is obtained when the contrast is equal to 0.951. Furthermore, the non-linear function and optional point stay constant regardless of screen size and reading amount. The paper ends with implications of the results that maximal contrast does not always mean the optimal readability.

Spatial Luminance Contrast Sensitivity: Effects of Surround

  • Kim, Youn-Jin;Kim, Hong-Suk
    • Journal of the Optical Society of Korea
    • /
    • 제14권2호
    • /
    • pp.152-162
    • /
    • 2010
  • This study examined the effects of surround luminance on the shape of the spatial luminance contrast sensitivity function (CSF). The reduction in brightness of uniform neutral patches shown on a computer controlled display screen is also assessed to explain the change of CSF shape. Consequently, a large amount of reduction in contrast sensitivity at middle spatial frequencies can be observed; however, the reduction is relatively small for low spatial frequencies. In general, the effect of surround luminance on the CSF appears similar to that of mean luminance. Reduced CSF responses result in less power of the filtered image; therefore, the stimulus should appear dimmer with a higher surround luminance.

Perceived Image Contrast under a Wide Range of Surround Luminance

  • Baek, Ye-Seul;Kim, A-Ri;Kim, Youn-Jin;Kim, Hong-Suk;Park, Seung-Ok
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2009년도 9th International Meeting on Information Display
    • /
    • pp.1160-1163
    • /
    • 2009
  • Many researches showed that perceived image contrast increases as the relative surround luminance increases. However, most experiments were conducted under limited surround conditions. In this research, a psychophysical experiment was conducted to investigate the change in perceived image contrast under wide range of surround luminance up to 1820 cd/$m^2$. A large area illuminator was used as a backlight. It consists of 23 dimmable fluorescent lamps and a sheet of diffuser. The luminance could be adjusted to 7 different surround ratios: 0, 0.3, 0.56, 0.96, 2.24, 5.81, and 9.99. Results showed that perceived image contrast changes as a typical band-pass shape and the maximum contrast is found near $S_R$=1.

  • PDF

명소시 상태에서 휘도 감소에 따른 대비감도 변화 (Changes of Contrast Sensitivity with Decreasing Luminance in Photopic Conditions)

  • 이은진;윤문주;김수현;양계탁;정주현;김현정;김현일;최은정
    • 한국안광학회지
    • /
    • 제17권4호
    • /
    • pp.411-417
    • /
    • 2012
  • 목적: 명소시 상태에서 휘도의 감소에 따른 대비감도 변화에 대하여 조사하였다. 방법: FACT 시표를 이용하여 명소시 5단계의 휘도 하에서 63명의 대학생에 대한 대비감도를 조사하였다. 결과: 측정된 대비감도는 모두 정상범위 내에 있었다. $40~10cd/m^2$에서 대비감도의 정점이 6 cpd에서 3 cpd로 이동하는 것으로 관측되었고, 6 cpd와 3 cpd에 대한 가상적인 두 대비감도 직선들의 교점으로부터 정점은 약 $25cd/m^2$일때 6 cpd에서 3 cpd로 이동하는 것으로 평가되었다. 휘도가 $120cd/m^2$에서 $10cd/m^2$으로 감소하는 동안, 6 cpd에서 대비감도 손실이 가장 컸지만, 1.5 cpd에서의 대비감도는 큰 변화가 없었다. 근사적으로 평가된 $25cd/m^2$ 이상의 휘도에서 대비감도는 18<12<1.5<3<6 cpd의 순으로 높았지만, $25cd/m^2$이하의 휘도에서는 18<12<1.5<6<3 cpd의 순으로 높았다. 휘도의 감소에 따른 대비감도의 손실을 대비감도 감소량 및 감소율로도 평가하였다. 대비감도 감소량은 6 cpd에서 가장 컸지만, 감소율은 18 cpd에서 가장 컸다. 결론: 본 연구에서 활용된 평가법이 대비감도 변화를 평가하는 또 다른 방법으로 활용될 수 있음을 제안한다.

시각장애인 점자블록의 휘도대비 기준에 대한 연구 (A Study on Luminance Contrast Criteria for Tactile Walking Surface Indicators)

  • 신동홍;박광재;김상운
    • 의료ㆍ복지 건축 : 한국의료복지건축학회 논문집
    • /
    • 제22권1호
    • /
    • pp.7-15
    • /
    • 2016
  • Purpose: There are the number of color tactile walking surface indicators installed in Korea, because of indefinite regulation in blind and vision-impaired persons' tactile walking surface indicators. In case of yellow tactile walking surface indicators, it shows a deviation severe color. In this study, the researchers suggested color and brightness reference for helping blind and vision-impaired persons' walking through analyzing the color references of tactile walking surface indicators and the color luminance between tactile walking surface indicators and sidewalk currently used. Method: Reasonable luminance contrast criteria is suggested by examining ways of improving the recognition and recognition of objects according to color contrast visually impaired through literature review and analyzing standards of tactile walking surface indicators and the Europe, Japan and Australia of color and luminance contrast criteria. And by examining the color of the tactile walking surface indicators reported in Korea currently used to derive the problem presented by the luminance contrast in the reference and comparison. Finally, the visually impaired tactile walking surface indicators is set for color selection criteria for the recognition rate improves. Results: In order to improve the recognition rate to be tactile walking surface indicators of the contrast of the visually impaired and the environment than the color of the tactile walking surface indicators itself to secure always a certain level or more of brightness contrast values in the set of the color of the tactile walking surface indicators so important. Implication: In order to set the blind tactile walking surface indicators color recognition based on the verification of the real pedestrian based on the results presented in this paper it is required. It is to be understood as an element of the barrier free configuration for securing the walking pedestrian safety.

도로터널의 경계부 순응휘도 측정 및 분석 (Measurement and Analysis of Adaptation Luminance in the Threshold Zone of the Road Tunnel)

  • 한종성;이민욱;김훈
    • 조명전기설비학회논문지
    • /
    • 제26권1호
    • /
    • pp.1-7
    • /
    • 2012
  • As the standard lighting required in the threshold zone of a road tunnel is determined by the enough contrast. Lighting design, therefore, must be determined by the calculation method of threshold luminance based on the adaptation luminance of the driver approaching the tunnel. The veiling luminance and the luminance in the access zone were measured at different time and in different weather using the veiling luminance method, a kind of perceived contrast methods, and the L20 method when the range of vision was 20 degrees. On the basis of the measured data each threshold luminance was calculated and its results were analyzed.

Determination of the Perceived Contrast Compensation Ratio for a Wide Range of Surround Luminance

  • Baek, Ye Seul;Kim, Hong-Suk;Park, Seung-Ok
    • Journal of the Optical Society of Korea
    • /
    • 제18권1호
    • /
    • pp.89-94
    • /
    • 2014
  • It is established that the perceived image contrast is affected by surround luminance. In order to get the same perceived image contrast, the optimum surround compensation ratios for those surround conditions is needed. Much research has been performed for dark, dim, and average surrounds. In this study, a wide range of surround luminance from dark up to $2087cd/m^2$ was considered. Using magnitude estimation method, the change in perceived brightness of six test stimuli was measured under seven surround conditions; dark, dim, 2 levels of average, bright, and 2 levels of over-bright surrounds. To drive the perceived image contrast from the perceived brightness, two different definitions of contrast were tested. Their calculated results were compared with the visual data of our previous work. And to conclude, the perceived contrast compensation ratios were 1:1.11:1.2 for average, dim and dark surrounds. These were close to CIECAM02 model (1:1.17:1.31). Besides, for average, bright, over-bright1 and over-bright2 surrounds the ratios 1:1.17:1.42:1.69 were determined. For intermediate or more extreme surround conditions, the compensation ratio was obtained from the linear interpolation or extrapolation.

편광을 이용한 눈의 공간주파수-대비민감도 함수 측정기구 설계 (Contrast Sensitivity as a function of spatial frequency by using polarization)

  • 김용근
    • 한국안광학회지
    • /
    • 제5권1호
    • /
    • pp.43-48
    • /
    • 2000
  • Polarizer와 Analyzer의 Rotation 각에 의해 광의 luminance를 조절할 수 있다. Contrast Sensitivity에 대응한 luminance 값 $L_{max}$, $L_{min}$은 평균 luminance($L_m$)의 회전각 ${\theta}_m$ 최대 진폭과 최소 진폭에 대응하는 회전각 (${\theta}_{max}$, ${\theta}_{min}$)로 부터 구할 수 있다. $$L_{max}=I(0)e^{-2at}{\cdot}cos^2{\theta}_m(1+C_s^{-1})$$ $$L_{min}=I(0)e^{-2at}{\cdot}cos^2{\theta}_m(1-C_s^{-1})$$ 평균 luminance($L_m$)의 회전각 ${\theta}_m$과 측정할 Contrast Sensitivity($C_s$)로부터 polarizer와 analyzer의 회전각(${\theta}_{max}$, ${\theta}_{min}$)을 얻었다. $${\theta}_{max}=cos^{-1}[cos{\theta}_m{\cdot}(1+C_s^{-1})^{1/2}]$$ $${\theta}_{min}=cos^{-1}[cos{\theta}_m{\cdot}(1-C_s^{-1})^{1/2}]$$.

  • PDF

창호의 차양 조절에 따른 실내 글레어 평가 (Evaluating Interior Glare Base on Shading Adjustments)

  • 임상훈
    • 한국생활환경학회지
    • /
    • 제20권2호
    • /
    • pp.233-237
    • /
    • 2013
  • Daylighting affects the luminous environment and provides comfortable environment to the occupants. However, excessive daylighting might have negative influences on the visual comfort. Skylight, light intensity and distribution, and insolation could cause glare effects on the occupants. This study analyzed the effect of fenestration on the interior glare effects, and verified luminous environment adjustability through mock up test of conventional fenestration and 'Convergence Window System' by analyzation of luminance, luminance contrast, and glare effect. Consequently, room installed Convergence Window System was improved luminance contrast and PGSV Level.