• Title/Summary/Keyword: Luminance Measurements

Search Result 41, Processing Time 0.023 seconds

Fast Measurement of Eyebox and Field of View (FOV) of Virtual and Augmented Reality Devices Using the Ray Trajectories Extending from Positions on Virtual Image

  • Hong, Hyungki
    • Current Optics and Photonics
    • /
    • v.4 no.4
    • /
    • pp.336-344
    • /
    • 2020
  • Exact optical characterization of virtual and augmented reality devices using conventional luminance measuring methods is a time-consuming process. A new measurement method is proposed to estimate in a relatively short time the boundary of ray trajectories emitting from a specific position on a virtual images. It is assumed that the virtual image can be modeled to be formed in front of one's eyes and seen through some optical aperture (field stop) that limits the field of view. Circular and rectangular shaped virtual images were investigated. From the estimated ray boundary, optical characteristics, such as the viewing direction and three dimensional range inside which a eye can observe the specified positions of the virtual image, were derived. The proposed method can provide useful data for avoiding the unnecessary measurements required for the previously reported method. Therefore, this method can be complementary to the previously reported method for reducing the whole measurement time of optical characteristics.

A Large Sky Simulator : A Reproduction of CIE Sky Condition and Daylighting Evaluation using Scale Model

  • Yu, In-Hye;Ahn, Hyun-Tae;Kim, Jeong-Tai
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.21 no.4
    • /
    • pp.1-10
    • /
    • 2007
  • KH University has developed a large sky simulator which is its scale suits international standard. To verify the reliability of the sky simulator, the luminance of 36 points on the inner sky surface was measured and compared with the CIE standard overcast sky model. It was found that the sky simulator can reproduce the CIE standard overcast sky condition with 1.8[%] of mean difference. To identify the differences of daylighting performance, scale model measurements were taken under a real sky and in a sky simulator. Under overcast sky conditions, two kinds of scale model experiments were conducted by using the photometric sensor Li-cor. Firstly, a 1/20 scale model of a side-lit office room 4.9[m] wide, 7.2[m] long, and 2.6[m] high was created. Five measurement points were set at 1.2[m], 2.4[m], 3.6[m], 4.8[m], and 6.0[m] from the window. The mean difference of the light factor between the sky simulator and real sky was 7.1[%]. Secondly, a 1/30 scale model of a top-lit atrium 15[m] wide, 15[m] long, and 15[m] high was created. The measurement point was set at center of the room and the well indexes of the model were set in 5 types. The mean difference of the light factor between the sky simulator and real sky was 1.7[%]. This proved that the sky simulator is fully accurate and usable for daylighting research.

A Study on Production and Its Usefulness of AAPM TG18 Guiding Instrument for Diagnostic Monitor QC (영상의학 검사 판독용 모니터 정도관리 Guiding Instrument 제작과 유용성 고찰)

  • Son, Gi-Gyeong;Sung, Dong-Wook;Jeong, Jae-Ho;Kang, Hui-Doo;Ryu, Kyung-Nam
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.10 no.1
    • /
    • pp.21-28
    • /
    • 2008
  • Diagnostic display monitor QA according to AAPM TG18 is usually performed by PACS administrator, product manager and reading doctor, and for acceptance testing and periodic quality control evaluation, a combination of visual and quantitative tests can be used, as outlined in sections 5 and 6 of 'assessment of display performance for medical imaging systems'. Although many display tests can be performed visually, a more objective and quantitative evaluation of display performance requires special test tools. The required instruments vary in their complexity and cost, depending on the context of the evaluation(research, acceptance testing, or quality control) and how thorough the evaluation needs to be. Objective and reliable assessment of many display characteristics can be performed with relatively inexpensive equipment, So, we made 'AAPM TG18 guiding instrument' to ues variable purpose of the evaluation of 'geometrical distortions(quantitative"', 'veiling glare(visual)' and 'sensor calibration'. The spatial measurements for the quantitative evaluation of geometric distortions, and the measurement of the veling-glare ring response function which provides information regarding the spatial extent of the luminance spread, can be performed using the TG18 guiding instrument can be used to sensor calibration to standardize the basic rate of 0% luminance when periodic calibration.

  • PDF

A study on the application of dichroic mirror for the improvement of luminance and luminous efficacy in an AC Plasma Display Panel (AC-PDP의 휘도와 효율 향상을 위한 Dichroic Mirror의 응용에 관한 연구)

  • 송병무;김중균;황만수;황기웅
    • Journal of the Korean Vacuum Society
    • /
    • v.10 no.1
    • /
    • pp.98-103
    • /
    • 2001
  • A new application of dirchroic mirror for the improvement of luminance and luminous efficacy in an AC-Plasma Display Panel (PDP) is suggested. Only about half of the Vacuum Ultraviolet (VUV) generated in the reflective PDP cell is used for the excitation of the phosphor. We are suggesting an idea of adopting a dichroic mirror which can reflect the VUV toward the phosphor which otherwise is absorbed by the front panel. The optical constants of the thin films of dirhroic mirror were determined from the photometric measurements through an iteration process of matching calculated and measured values of the reflectance and transmittance in the VUV wavelength region. From these results, we could design such a filter whose high reflection zone is centered at 147nm by a computer simulation accurately. The 147nm VUV is radiated from Xenon 3Pl state which is dominantly used to activate the phosphor in the PDP cell. The dichroic mirror was made with an electronbeam evaporator and its reflectance was measured by a reflectometer. We confirmed the usefulness of the dichroic mirror for the improvement of efficiency with experiments done by test panels. The panel with mirror shows improved luminance and luminous efficacy by 20∼30%.

  • PDF

The Analysis of the Correlation between the Sustain-Electrode Gap of an AC-PDP and Address Discharge Characteristics (AC-PDP의 유지방전 전극사이의 간격과 어드레스 방전 특성과의 상관성 분석)

  • Lee, Young-Jun;Choi, Su-Sam;Park, Se-Kwang;Kim, Yong-Duk
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.55 no.5
    • /
    • pp.239-244
    • /
    • 2006
  • To drive the high-image quality plasma displays of XGA and/or full-HD, we must effectively improve the driving waveform, which get the reset period for the stabilized control of wall charges, the address period to select discharge or non-discharge, and sustain period for luminance in 1 TV-frame, and also the display quality. To accomplish them, the development of the technology for the fast address discharge is required. In this paper, the correlation between the sustain-electrode gap and address discharge characteristics for the high-speed addressing was analyzed using the measurements of dynamic voltage margins. Results showed that the narrower the gap between the sustain electrodes, the narrower the with of the scan pulse became and a dynamic margin of data voltage of 29.2 V was obtained at scan pulse width of $1.0{\mu}s\;and\;V_{ramp}$ of 240 V for driving 4-inch test penal, which the gap between sustain electrodes was $65{\mu}m$.

ACHIEVING CONSISTENCY IN LIGHTING SCHEMES FOR CONSTRUCTION WORK ZONES THROUGH LIGHTING SIMULATION

  • Khaled Nassar;Soo-Young Kim
    • International conference on construction engineering and project management
    • /
    • 2007.03a
    • /
    • pp.269-278
    • /
    • 2007
  • Nighttime construction is being adopted by many state DOT's as a way to mitigate the impact of construction operations on the traveling public. Although a number of states have developed standard specifications for nighttime lighting, these standards are usually in the form of generic requirement statements that only specify minimum illuminance levels. The lighting standards do not include specific ways to achieve this illuminance level such as lighting arrangements and configurations for various work zone plans and construction operations. This leaves confusion between the traffic engineers and the contractors and does not guarantee consistency in those plans, thus affecting productivity and safety (lighting conditions account for 18% to 28% of work zone accidents). The main objective of this study is to utilize three dimensional animation and lighting analysis software to study and model lighting conditions of a construction site. This is expected to increase the safety and productivity of construction operations by achieving consistency in work zone lighting schemes. A computerized model was developed, called Nitelite. Various lighting schemes can be studied using the software to provide for typical applications including lighting fixture's locations, luminance, mounting height, tilt angle, and fixture type. The results from the developed software tool were validated through comparisons with previous research conducted using field measurements.

  • PDF

Use of Self Assembled Monolayer in the Cathode/Organic Interface of Organic Light Emitting Devices for Enhancement of Electron Injection

  • Manna, U.;Kim, H.M.;Gowtham, M.;Yi, J.;Sohn, Sun-young;Jung, Dong-Geun
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2005.07b
    • /
    • pp.1343-1346
    • /
    • 2005
  • Self assembled monolayers (SAM) are generally used at the anode/organic interface to enhance the carrier injection in organic light emitting devices, which improves the electroluminescence performance of organic devices. This paper reports the use of SAM of 1-decanethiol (H-S(CH2)9CH3) at the cathode/organic interface to enhance the electron injection process for organic light emitting devices. Aluminum (Al), tris-(8-hydroxyquionoline) aluminum (Alq3), N,N'-diphenyl-N,N'-bis(3 -methylphenyl)-1,1'- diphenyl-4,4'-diamine (TPD) and indium-tin-oxide (ITO) were used as bottom cathode, an emitting layer (EML), a hole-transporting layer (HTL) and a top anode, respectively. The results of the capacitancevoltage (C-V), current density -voltage (J-V) and brightness-voltage (B-V), luminance and quantum efficiency measurements show a considerable improvement of the device performance. The dipole moment associated with the SAM layer decreases the electron schottky barrier between the Al and the organic interface, which enhances the electron injection into the organic layer from Al cathode and a considerable improvement of the device performance is observed. The turn-on voltage of the fabricated device with SAM layer was reduced by 6V, the brightness of the device was increased by 5 times and the external quantum efficiency is increased by 0.051%.

  • PDF

Electrical and Luminescent Properties of OLEDs by Nickel Oxide Buffer Layer with Controlled Thickness (NiO 완충층 두께 조절에 의한 OLEDs 전기-광학적 특성)

  • Choi, Gyu-Chae;Chung, Kook-Chae;Kim, Young-Kuk;Cho, Young-Sang;Choi, Chul-Jin;Kim, Yang-Do
    • Korean Journal of Metals and Materials
    • /
    • v.49 no.10
    • /
    • pp.811-817
    • /
    • 2011
  • In this study, we have investigated the role of a metal oxide hole injection layer (HIL) between an Indium Tin Oxide (ITO) electrode and an organic hole transporting layer (HTL) in organic light emitting diodes (OLEDs). Nickel Oxide films were deposited at different deposition times of 0 to 60 seconds, thus leading to a thickness from 0 to 15 nm on ITO/glass substrates. To study the influence of NiO film thickness on the properties of OLEDs, the relationships between NiO/ITO morphology and surface properties have been studied by UV-visible spectroscopy measurements and AFM microscopy. The dependences of the I-V-L properties on the thickness of the NiO layers were examined. Comparing these with devices without an NiO buffer layer, turn-on voltage and luminance have been obviously improved by using the NiO buffer layer with a thickness smaller than 10 nm in OLEDs. Moreover, the efficiency of the device ITO/NiO (< 5 nm)/NPB/$Alq_3$/ LiF/Al has increased two times at the same operation voltage (8V). Insertion of a thin NiO layer between the ITO and HTL enhances the hole injection, which can increase the device efficiency and decrease the turn-on voltage, while also decreasing the interface roughness.

Development of Wireless Healthcare System for Emergency Treatment (응급상황을 대비한 무선의료관리시스템 개발)

  • Park, Sung-Chul;Moon, Byung-Hyun;Lim, Byung-Hyun;Hwang, Bum-Suk;Choi, Sang-Min
    • Journal of Korea Society of Industrial Information Systems
    • /
    • v.14 no.5
    • /
    • pp.125-130
    • /
    • 2009
  • Today, the handicapped or old people require continuous care, but there are a lot of practical difficulties. In this paper, the system measuring health conditions of the handicapped or old people (pulse and temperature) is developed. If urgent health conditions occur, measurement values are delivered to doctors or close family members using SMS (Short Message Service) of cellular phone. In the developed system, Pulse rate is measured by sensing bloodstream using high luminance LED and CdS illumination sensors. Body temperature is also measured by contactless temperature sensor. Also, the measured values are transmitted to a server computer using Zigbee communications. Also, the measured values the average of measurements and the time are saved. The wireless healthcare system is designed to help the emergency for the handicapped and old people by using SMS.

Development of Thermoluminescence and Optical Stimulated Luminescence Measurements System (열자극발광 및 광자극발광 측정장치의 개발)

  • Park, Chang-Young;Chung, Ki-Soo;Lee, Jong-Duk;Chang, In-Su;Lee, Jungil;Kim, Jang-Lyul
    • Journal of Radiation Protection and Research
    • /
    • v.40 no.1
    • /
    • pp.46-54
    • /
    • 2015
  • The thermoluminescence (TL) and optically stimulated luminescence (OSL) are commonly used to measure and record the expose of individuals to ionization radiation. Design and performance test results of a newly developed TL and OSL measurement system are presented in this paper. For this purpose, the temperature of the TL material can be controlled precisely in the range of $1{\sim}1.5^{\circ}C$ by using high-frequency (35 kHz) heating system. This high-frequency power supply was made of transformer with ferrite core. For optical stimulation, we have completed an optimal combination of the filters with the arrangement of GG420 filter for filtering the stimulating light source and a UG11 filter at the detecting window (PMT). By using a high luminance blue LED (Luxeon V), sufficient luminous intensity could be obtained for optical stimulation. By using various control boards, the TL/OSL reader device was successfully interfaced with a personal computer. A software based on LabView program (National Instruments, Inc.) was also developed to control the TL/OSL reader system. In this study, a multi-functional TL/OSL dosimeter was developed and the performance testing of the system was carried out to confirm its reliability and reproducibility.