• 제목/요약/키워드: Lumbosacral pain

검색결과 104건 처리시간 0.027초

대맥(帶脈) 및 그 유주상(流注上) 회합(會合)하는 경혈(經穴)에 대한 문헌적(文獻的) 고찰(考察) (Study on Dai Meridian(帶脈) and Meridian Points(經穴) of Joining with Circulation of Dai Meridian through Literatures of Every Generation)

  • 양승정;진천식;조명래
    • Korean Journal of Acupuncture
    • /
    • 제18권1호
    • /
    • pp.105-116
    • /
    • 2001
  • We examined and referred to some literatures on the meaning, Dai meridian and Meridian points of joining with circulation of Dai meridian through literatures of every generation. And then we came to get a few conclusions as follows. 1. Dai meridian starts below the hypochondriac region. Running obliquely downward, it runs transversely around the waist like a belt. Its function is to bind up all the meridians to circulate in a proper way. 2. The coalescent points of dai meridian are $D\grave{a}im\grave{a}i$(帶脈), $W\check{u}sh\bar{u}$(五樞) and $W\acute{e}id\grave{a}o$(維道). 3. Location of $D\grave{a}im\grave{a}i$(帶脈) is on the lateral side of the abdomen, 1.8 cun below $Zh\bar{a}ngm\grave{e}n$(章門), at the crossing point of vertical line through the free end of the 11th rib and a horizontal line through the umbilicus. Location of $W\check{u}sh\bar{u}$(五樞) is on the lateral side of the abdomen, anterior to the anterosuperior iliac spine, 3 cun below the level of the umbilicus. Location of $W\acute{e}id\grave{a}o$(維道) is on the lateral side of the abdomen, anterior and inferior to the anterosuperior iliac spine, 0.5 cun anterior and inferior to $W\check{u}sh\bar{u}$(五樞). 4. Indication of $D\grave{a}im\grave{a}i$(帶脈) is irregular menstruation, leukorrhea with reddish discharge, hernia, pain in the lumbar and hypochondriac region. Indication of $W\check{u}sh\bar{u}$(五樞) is prolapse of the uterus, leukorrhea with reddish discharge, irregular menstruation, hernia, pain in the lower abdomen, constipation and lumbosacral pain. Indication of $W\acute{e}id\grave{a}o$(維道) is edema, pain in the side of the lower abdomen, prolapse of the uterus, hernia and morbid leukorrhea. 5. The Dai meridian binds all meridians, produces pregnancy, grasps lumbar and abdomen region and controls leukorrhea. 6. Diseases of the Dai meridian manifested as distention and fullness in the lumbar region and abdomen, leukorrhea with reddish discharge, pain the navel, lumbar and spinal regions, flaccidity and hypoactivity of the lower limbs, etc.

  • PDF

Reliability and Validity of the Side-lying Instability and Prone Instability Tests in Patients with Lumbar Segmental Instability

  • Kim, Bo-Eon;Lee, Kwan-Woo;Park, Dae-Sung
    • 대한물리의학회지
    • /
    • 제16권1호
    • /
    • pp.1-7
    • /
    • 2021
  • PURPOSE: The purpose of this study is to conduct inter-rater and intra-rater reliability tests in patients with low back pain (LBP) using the prone instability test (PIT) and side-lying instability test (SIT). We have analyzed the Korean version Oswestry disability index (K-ODI) correlations and radiograph finding (RF) for validity. METHODS: Individuals (n = 51) (mean age of 40.27 ± 13.28) with LBP for at least over a week were recruited, together with two participating physical therapist examiners. The measurement consisted of PIT, PST, K-ODI, and RF. Sensitivity (Sn), specificity (Sp), positive predictive value, negative predictive value, prevalence index, agreement %, Cohen's kappa, and prevalence-adjusted bias-adjusted kappa (PABAK) were calculated. The PIT and SIT were compared with RF for validity analysis, while PIT, SIT, K-ODI, and RF were calculated for the correlation analysis. RESULTS: The intra-rater reliability test measured for the PIT (kappa = .79, PABAK = .88) and SIT (kappa = .73, PABAK = .84), and inter-rater reliability test measured for the SIT (kappa = .80, PABAK = .88) showed good agreements. The PIT (Sn = .65, Sp = .63) and SIT validities (Sn = .68, Sp = .70) were compared with RF, showing a significant correlation in PIT and RF (r = .69), SIT and RF (r = .73), and PIT and K-ODI (r = .53). CONCLUSION: The SIT is a more comfortable position test than the PIT in patients. Both PIT and SIT have acceptable reliability and validity.

백서(白鼠)의 formalin 유발(誘發) 통증(痛症)에 대한 전침자극(電鍼刺戟)과 하행성 진통기전 (Heterotopic electroacupuncture modulates formalin-induced pain via descending inhibition in the rat)

  • 구성태;손인철;김재효
    • Korean Journal of Acupuncture
    • /
    • 제23권3호
    • /
    • pp.55-71
    • /
    • 2006
  • Objectives : The present study was investigated the effect and pathway of heterotopic electroacupuncture (EA) on pain induced by formalin in rats. Methods : Acupoints in the right forepaws, $HT_7$ and $PC_7$, were stimulated with 3 mA, 2 ms, and 10 Hz before subcutaneously formalin injection (5%, $50{\mu}l$) to the left hind paw. Moreover, it was investigated whether the dorsolateral funiculus (DLF), as known to the descending inhibition, mediates analgesia of the heterotopic EA, and an administration of naltrexone blocks the effect of EA. Results : In the immunohistochemistry of cFos-like protein (cFL), there were inhibitory effects of EA on the increased expression of cFL in the lumbar spinal dorsal horn neurons following formalin injection. Especially, EA inhibited the expression of cFL on the superficial laminae than that on the deep laminae at 1 hr after, but that on the deep laminae than that on the superficial laminae at 2 hr after. Also, EA suppressed the increased expression of nitric oxide (NO) and neuronal nitric oxide synthase (nNOS) in the lumbosacral spinal cord after formalin injection, but not Sham-EA. Suppressed expressions of cFL, NO and nNOS in the spinal cord were eliminated after transection of the ipsilateral DLF at $T_{10}{\sim}T_{11}$ levels. However, pretreatment of naltrexone could not prevent the suppressive expressions of cFL, NO and nNOS at the spinal cord. Conclusions : These results suggest that the analgesia of heterotopic EA may be modulated through the DLF constituting the descending inhibition.

  • PDF

초음파 유도하 요추 및 제1천추 신경근 차단술의 타당성 연구 (Feasibility of Ultrasound-Guided Lumbar and S1 Nerve Root Block: A Cadaver Study)

  • 김재원;박혜정;이원일;원선재
    • Clinical Pain
    • /
    • 제18권2호
    • /
    • pp.59-64
    • /
    • 2019
  • Objective: This study evaluated the feasibility of ultrasound-guided lumbar nerve root block (LNRB) and S1 nerve root block by identifying spread patterns via fluoroscopy in cadavers. Method: A total of 48 ultrasound-guided injections were performed in 4 fresh cadavers from L1 to S1 roots. The target point of LNRB was the midpoint between the lower border of the transverse process and the facet joint at each level. The target point of S1 nerve root block was the S1 foramen, which can be visualized between the median sacral crest and the posterior superior iliac spine, below the L5-S1 facet joint. The injection was performed via an in-plane approach under real-time axial view ultrasound guidance. Fluoroscopic validation was performed after the injection of 2 cc of contrast agent. Results: The needle placements were correct in all injections. Fluoroscopy confirmed an intra-foraminal contrast spreading pattern following 41 of the 48 injections (85.4%). The other 7 injections (14.6%) yielded typical neurograms, but also resulted in extra-foraminal patterns that occurred evenly in each nerve root, including S1. Conclusion: Ultrasound-guided injection may be an option for the delivery of injectate into the S1 nerve root, as well as lumbar nerve root area.

흉(胸)·요추압박골절(腰椎壓迫骨折) 환자(患者)의 화타협척혈 침치료(鍼治療)에 대한 임상적 고찰 (The Clinical Study on Hua-Tuo-Jia-Ji-Xue(華佗夾脊穴) Acupuncture Treatment of Patient with Thoracolumbar Compression Fracture)

  • 송원섭;황재연;신영일;이병렬
    • Journal of Acupuncture Research
    • /
    • 제18권4호
    • /
    • pp.55-67
    • /
    • 2001
  • Objective : This study was performed to evaluate result of thoracolumbar compression fracture patient treated with Hua-Tuo-Jia-Ji-Xue(華佗夾脊穴) acupuncture. Methods : This clinical study was carried out 50 cases with thoracolumbar compression fracture, who had been admitted from January, 2000 to February, 2001, in the department of acupuncture and moxibustion, Hanseo University Oriental Medical Hospital. We divided two groups; A group, without using Hua-Tuo-Jia-Ji-Xue(華佗夾脊穴) acupuncture and the other group is B group, by using Hua-Tuo-Jia-Ji-Xue(華佗夾脊穴) acupuncture. Results : 1. The distribution of sex and age, 78% were female, and 84% were most above there sixties. 2. In the duration of symptom, the largest group was over 4 weeks. 3. In the distribution of cause, the largest group was "lifting heavy object"(32%) and the next was "slip down"(26%). 4. In the distribution of injured level was L1 body the most(19.6%) and T12 body was the next. 5. In the distribution of clinical symptoms on the admission, the largest group was lumbosacral pain(18%). 6. The result of treatment due to the duration of admission, 17case(34%) was the most above "Fair" during the 2~3 weeks. 7. The result of treatment, Good and Fair were the same in 24case(48%). 8. The duration of treatment was longer in high grade of clinical symptom. 9. B group discharged above good state 60% higher than A group.

  • PDF

Retethering : A Neurosurgical Viewpoint

  • Lee, Ji Yeoun;Kim, Kyung Hyun;Park, Kwanjin;Wang, Kyu-Chang
    • Journal of Korean Neurosurgical Society
    • /
    • 제63권3호
    • /
    • pp.346-357
    • /
    • 2020
  • During the follow-up period after surgery for spinal dysraphism, a certain portion of patients show neurological deterioration and its secondary phenomena, such as motor, sensory or sphincter changes, foot and spinal deformities, pain, and spasticity. These clinical manifestations are caused by tethering effects on the neural structures at the site of previous operation. The widespread recognition of retethering drew the attention of medical professionals of various specialties because of its incidence, which is not low when surveillance is adequate, and its progressive nature. This article reviews the literature on the incidence and timing of deterioration, predisposing factors for retethering, clinical manifestations, diagnosis, surgical treatment and its complications, clinical outcomes, prognostic factors after retethering surgery and preventive measures of retethering. Current practice and opinions of Seoul National University Children's Hospital team were added in some parts. The literature shows a wide range of data regarding the incidence, rate and degree of surgical complications and long-term outcomes. The method of prevention is still one of the main topics of this entity. Although alternatives such as spinal column shortening were introduced, re-untethering by conventional surgical methods remains the current main management tool. Re-untethering surgery is a much more difficult task than primary untethering surgery. Updated publications include strong skepticism on re-untethering surgery in a certain group of patients, though it is from a minority of research groups. For all of the abovementioned reasons, new information and ideas on the early diagnosis, treatment and prevention of retethering are critically necessary in this era.

척수전근내 구심흥분을 받는 척수신경세포의 생리학적 특성 (Electrophysiological Characteristics of Spinal Neurons Receiving Ventral Root Afferent Inputs in the Cat)

  • 김전;이석호;정순동
    • The Korean Journal of Physiology
    • /
    • 제24권2호
    • /
    • pp.389-402
    • /
    • 1990
  • The physiological characteristics of the neurons receiving the ventral root afferent inputs were investigated in the cat. A total of 70 cells were identified in the lumbosacral spinal cord. All these cells responded only to the C-strength stimulation of the distal stump of cut ventral root and the estimated conduction velocities of the VRA fibers were not faster than 4 m/sec. The majority of them were silent in resting state. For 49 cells, their peripheral receptive fields were characterized. Among them, 25 cells were exclusively excited by VRA inputs, 8 were inhibited and the remaining cells recevied both excitatory and inhibitory VRA inputs. According to the response pattern to the mechanical stimuli applied to their receptive fields, only a fourth of them were typical high threshold cell, a sixth, wide dynamic range cells, while remainings were a rather complex cells. Most of the cells receiving VRA inputs, received only the A ${\delta}-peripheral$ nerve inputs. Intravenous injection of morphine decreased the response of spinal cells to the VRA activation. The responses were abolished completely by counter irritation to the common peroneal nerve with C-strength-low frequency stimuli. These physiological properties of the spinal neurons receiving the VRA inputs are differ in some aspect from the spinal neurons receiving nociceptive inputs from the periphery, but still were consistent with the contention that VRA system might carry nociceptive informations arising from the spinal cord and/or neraby surrounding tissues.

  • PDF

Sciatic nerve neurolymphomatosis as the initial presentation of primary diffuse large B-cell lymphoma: a rare cause of leg weakness

  • Kim, Kyoung Tae;Kim, Se Il;Do, Young Rok;Jung, Hye Ra;Cho, Jang Hyuk
    • Journal of Yeungnam Medical Science
    • /
    • 제38권3호
    • /
    • pp.258-263
    • /
    • 2021
  • Neurolymphomatosis (NL) is defined as the involvement of the peripheral nervous system in lymphocytic invasion. It is a very rare form of lymphoma that may occur as an initial presentation or recurrence. It affects various peripheral nervous structures and can therefore mimic disc-related nerve root pathology or compressive mononeuropathy. NL often occurs in malignant B-cell non-Hodgkin lymphomas. Notwithstanding its aggressiveness or intractability, NL should be discriminated from other neurologic complications of lymphoma. Herein, we present a case of primary NL as the initial presentation of diffuse large B-cell lymphoma (DLBCL) of the sciatic nerve. The patient presented with weakness and pain in his left leg but had no obvious lesion explaining the neurologic deficit on initial lumbosacral and knee magnetic resonance imaging (MRI). NL of the left sciatic nerve at the greater sciatic foramen was diagnosed based on subsequent hip MRI, electrodiagnostic test, positron emission tomography/computed tomography, and nerve biopsy findings. Leg weakness slightly improved after chemotherapy and radiotherapy. We report a case wherein NL, a rare cause of leg weakness, manifested as the initial presentation of primary DLBCL involving the sciatic nerve at the greater sciatic foramen.

Relationship between Spinopelvic Parameters and Hip Function in Patients with Femoroacetabular Impingement at Diagnosis: A Cross-Sectional Study

  • Bernardo Aguilera-Bohorquez;Pablo Corea;Cristina Siguenza;Jochen Gerstner-Saucedo;Alvaro Carvajal;Erika Cantor
    • Hip & pelvis
    • /
    • 제35권1호
    • /
    • pp.6-14
    • /
    • 2023
  • Purpose: The aim of this study was to determine correlation between the spinopelvic parameters in sitting and standing positions (sacral slope [SS], lumbar lordosis [LL], spinopelvic tilt [SPT], pelvic incidence [PI], and pelvic femoral angle [PFA]), with hip function assessed using the modified Harris hip scores (mHHs) in patients with symptomatic femoroacetabular impingement (FAI) at diagnosis. Materials and Methods: A retrospective study of 52 patients diagnosed with symptomatic FAI was conducted. Evaluation of the spinopelvic complex in terms of SS, LL, SPT, PI and PFA was performed using lateral radiographs of the pelvis and lumbosacral spine in standing and sitting positions. Assessment of hip function at diagnosis was performed using the mHHs. Calculation of spinopelvic mobility was based on the difference (Δ) between measurements performed in standing and sitting position. Results: The median time of pain evolution was 11 months (interquartile range [IQR], 5-24 months) with a median mHHs of 66.0 points (IQR, 46.0-73.0) at diagnosis. The mean change of LL, SS, SPT, and PFA was 20.9±11.2°, 14.2±8.6°, 15.5±9.0°, and 70.7±9.5°, respectively. No statistically significant correlation was observed between spinopelvic parameters and the mHHs (P>0.05). Conclusion: Radiological parameters of the spinopelvic complex did not show correlation with hip function at the time of diagnosis in patients with symptomatic FAI. Conduct of further studies will be required in the effort to understand the effect of the spinopelvic complex and its compensatory mechanics, primarily between the hip and spine, in patients with FAI before and after hip arthroscopy.

새롭게 개발한 요천추 보조기의 과제 수행 중 척추의 고정효과와 복부압력 (Immobilization Effect and Abdominal Pressure of Newly-Developed Lumbosacral Spinal Orthosis during Task Performance)

  • 전경수;양희승;장수웅;신희동;이윤경;이영;이슬빛나;안동영;심우섭;조민;조규직;박동범;박관수
    • Clinical Pain
    • /
    • 제19권2호
    • /
    • pp.70-79
    • /
    • 2020
  • Objective: We evaluated the efficacy of a newly-developed spinal orthoses (V-LSO) by comparing the stabilizing effect, abdominal pressure, and comfort of 3 different semirigid LSOs (classic LSO, V-LSO, and Cybertech®) during various body movements. Method: Thirty healthy volunteers (23~47 years, 24 males, 6 females) were selected. A dual inclinometer measured the range of motion (ROM) while the participants performed flexion/extension and lateral flexion of the lumbar spine with 3 LSOs. The LSO's pressure on the abdominal surface was measured using 9 pressure sensors while lying, sitting, standing, flexion/extension, lateral flexion, axial rotation, and lifting a box. Comfort and subjective immobilization were analyzed by a questionnaire. Results: V-LSO had a statistically significant effect on flexion over Cybertech®. No significant differences were noted during extension and lateral flexion between the 3 LSOs. The abdominal pressure showed no significant differences while supine. While sitting, standing, and lifting a box, the mean abdominal pressure for V-LSO were significantly higher than those for Cybertech®. During lumbar flexion, the mean abdominal pressures for classic LSO and V-LSO were significantly higher than that of Cybertech®. For extension, lateral flexion and axial rotation, the abdominal pressure for V-LSO was significantly higher than those of classic LSO and Cybertech®. In the subjective analysis, V-LSO and Cybertech® scored best for comfort. Conclusion: The V-LSO and Cybertech® were more comfortable than the classic LSO, and hence, may have improved compliance with decreased discomfort. V-LSO may be superior to the other LSOs in restricting lumbar movement and increasing intraabdominal pressure.