• Title/Summary/Keyword: Lubricating Pipe

Search Result 11, Processing Time 0.025 seconds

A Study on the Flow Characteristic of Lubrication Oil System in Manual Transmission System for Large Commercial Vehicle (대형 상용차용 수동변속기내 윤활시스템의 유동특성에 관한 연구)

  • Yi, Chung-Seob;Suh, Jeong-Se;Song, Chul-Ki;Shin, Yoo-In;Yun, Ji-Hun;Chung, Kyung-Taek
    • The KSFM Journal of Fluid Machinery
    • /
    • v.13 no.6
    • /
    • pp.77-82
    • /
    • 2010
  • This study has conducted numerical analysis for lubrication system of transmission for commercial vehicle. The lubrication oil system in transmission can be applied to a large scale commercial vehicle which is over 15tons. The flow rate of lubricating oil has been obtained for each of branch port from the lubrication pipe. The results from numerical simulation are mainly suggested for the mass flow rate of lubrication oil in the rotating main shaft of transmission system. It has been found that the mass flow rate from oil hole increased with an rotating rate of main shaft. The flow characteristic from oil hole has been presented for the lubricating system in the manual transmission.

A new method to estimate rheological properties of lubricating layer for prediction of concrete pumping

  • Jang, Kyong Pil;Kim, Woo Jae;Choi, Myoung Sung;Kwon, Seung Hee
    • Advances in concrete construction
    • /
    • v.6 no.5
    • /
    • pp.465-483
    • /
    • 2018
  • The most crucial factor determining the pumping performance of concrete is the characteristics of the lubricating layer formed between the pipe wall and the inner concrete. Thus, it is important to accurately identify the rheological properties of the lubricating layer to predict the pumping of concrete. In this study, a new method is proposed for measuring the rheological properties of the lubricating layer with improved convenience. To verify the new method, a pumping test was conducted with 337 m-long horizontal piping. The rheological properties of the lubricating layer were assessed by a previously verified method and the new method proposed in this study for a total of four concrete mixtures with design strength ranging from 27 MPa to 60 MPa. The correlation between the existing method and the new method in relation to the viscosity of the lubricating layer was determined, and it was possible to predict the pumping performance with an accuracy of about 88.5% using the viscosity of the lubricating layer obtained from this correlation.

Vibration Characteristics and its Countermeasure of Orifice Pipe for Reduction Gear Lubrication of Azimuth Thruster (아지무스 추진기의 감속 기어 윤활용 오리피스 파이프 진동특성과 방진대책)

  • Eam, Gitak;Barro, Ronald D.;Lee, Donchool
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2013.04a
    • /
    • pp.555-558
    • /
    • 2013
  • A type of electric propulsion employed by specialized purpose vessels or offshore is the azimuth thruster. Azimuth thruster application had been increasing recently and resulted to excellent vessel maneuverability. However, this system is very complex and some of its major component being exposed under the seawater level presents difficulty in sealing design. For Polar class icebreaker operating in extreme sea condition, this requires a high level of reliability and safety. In this study, the characteristics of lubricating orifice pipe structural vibration installed at the lower reduction gear were investigated and analyzed through beam analysis theory and comparison of experiments. Propeller excitation and the resonant modes of vibration causing excessive vibration and suitable countermeasures to prevent damage due to vibration fatigue on the pipe are presented.

  • PDF

Analysis of Discharged Oil Using Visualization Technique for Upper Part and Discharging Pipe of Rotary Compressor (로터리 압축기 상부 및 토출관 가시화에 의한 토유 오일 분석)

  • Cho, Pil-Jae;Sung, Chun-Mo;Shin, Chang-Joo;Ko, Han-Seo
    • Proceedings of the SAREK Conference
    • /
    • 2005.11a
    • /
    • pp.570-575
    • /
    • 2005
  • An efficiency of a refrigeration cycle and a reliability of a compressor can be reduced if a refrigerant including excessive lubricating oil is exhausted from a rotary compressor. Thus, the oil behavior inside the compressor should be analyzed to improve the efficiency. A tested rotary compressor has been manufactured with visualization windows at upper parts in this study to investigate the oil behavior using developed visualization techniques. Discharge pipe with level gage has been visualized to investigate discharged oil amount. The oil behaviors inside the compressor and discharging pipe at various operating conditions have been analyzed. The results of the visualization for the discharging pipe have been compared with those of the upper part to confirm the accuracy.

  • PDF

A Study on the Prevention of Spill of Fuel Oils and Lubricating Oils for Sunken Ships

  • Han, Won-Heui;Ju, Hae-Ji
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.21 no.3
    • /
    • pp.309-314
    • /
    • 2015
  • A sunken ship often involves an oil spill. This paper was carried out to minimize environmental and cost damages stemming from oil spil of sunken shipl. Through the analysis of both the standards of the oil tank system and installation, we have identified potential oil spill sites and proposed a remedy of prevention. The result of study, the air pipes of the oil tank are a vulnerable point for oil spill. Also, the remote control devices of emergency shut-off valve have poor accessibility at abandon ship, making it difficult to shut off the emergency shut-off valve. Thus, we propose the addition of a remote quick closing valve in the air pipe and the building of a central control system.

Experimental Quality Characteristics for Water Removal in Inner Flushing Oil in Process Piping of Offshore Plant (해양플랜트 프로세스 배관 내경 플러싱 오일속에서 수분제거를 위한 실험적 품질 특성)

  • Park, Chang-Soo;Sung, Ki-Young;Han, Seong Jong
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.22 no.6
    • /
    • pp.797-805
    • /
    • 2019
  • An important problem of offshore plant process piping is equipment accidents due to the removal of fine metal debris and foreign substances in the pipes that deliver fluids such as hydraulic oil, lubricating oil and thermal oil. Temporary flushing equipment to remove debris uses fluid equipment of centrifugal pump and gear pump to prevent equipment accident of offshore platform. The equipment manufacturer requires the shipyard to have a cleanliness rating inside the pipe to meet the international standards ISO4406 and NAS1638 quality levels to prevent damage to the equipment sold. The quality of the internal flushing of pipes conforms to the regulations suggested by the equipment manufacturer. In this paper, three types of electric heater capacity, which is a method of evaporating and removing water inside a pipe during an oil flushing process, were compared. In addition, the study was conducted to remove the flushing oil in the pipe and to improve oil quality.

Development of concrete pumping technology for construction of high-rise building using electromagnetic field (전자기장을 활용한 초고층 건축물 콘크리트 압송기술개발)

  • Kim, Woo-Jea;Kwon, Seung-Hee
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2018.05a
    • /
    • pp.4-5
    • /
    • 2018
  • Recently, high-strength concrete used for shortening the construction time of high-rise building construction, Concrete pumping technology is emerging as the core technology of high-rise buildings. In this paper, we have started to study the use of electromagnetic field as a method to increase the efficiency of the lubricating layer between the inside of the pipe and concrete, which has been established as the most important factor determining the pumping performance. The pumping performance improvement effect of concrete strength was verified and basic research was carried out to utilize it as a method to increase the efficiency of pumping in field application. In the related work, the effect of the electromagnetic field was verified by conducting a mock-up performance evaluation (horizontal 300 m) of the pumping force by the concrete strength.

  • PDF

A Phenomenological Study on the Flame Spread of Air Conditioner Indoor unit by Fire Tests (화재 실험을 통한 에어컨 실내기의 화염확산에 관한 현상학적 연구)

  • Choi, Seung-Bok;Lee, Seung-Hun;Choi, Min-Ki;Choi, Don-Mook
    • Fire Science and Engineering
    • /
    • v.27 no.6
    • /
    • pp.89-96
    • /
    • 2013
  • The purpose of this study is to check the fire origin and cause of the fire by observing the shape of the flame propagation in air-conditioner indoor unit through the fire tests. We supposed that the flame is spread from the surroundings to the top of the air-conditioner and ignited on top of the air-conditioner with n-heptane. And then repeated this experiment twice under the same conditions. After the ignition, refrigerant filled in air-conditioner and lubricating oil exploded with large explosion and flame having high temperature and pressure belched out rapidly due to bursting refrigerant pipe linked air-conditioner between 734 seconds and 559 seconds. After result of checking the combustion residue we found that almost all of that was lost except a part of the evaporator, motor and metal. The position of short-circuit traces of wiring for the air-conditioner ignited itself is similar to that of fire damage by external flame. Therefore, we verified that it is not certain to determine the ignition cause and point by only the shape of the combustion residues.

The quality improvement study on the crack of heat exchanger lubricating oil port in military aircraft (군용항공기 열교환기 윤활유 유입포트 균열개선 연구)

  • Park, Sung-Jae;Choi, Jae-Ho;Choi, Gil-Gyu;Lee, Dong-Ki
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.4
    • /
    • pp.164-172
    • /
    • 2020
  • The fuel oil/heat exchanger installed in military aircraft is a device that cools the lubricant oil supplied to other devices, such as an AMAD, and a hydraulic pump using the low temperature of the fuel is cracked at the AMAD lubricant inlet port. If a crack in the heat exchanger occurs, the lubricant oil supplied to other equipment is not cooled. Therefore, the flight can no longer be performed. In this study, non-destructive inspection and microscopic examination of the fracture surface of the oil port were performed to analyze the crack tendency. The oil pipe connected to the oil port is a titanium pipe, which is fastened with over torque and has been identified as the leading cause of heat exchanger oil port cracks. In addition, it was verified as the main reason for cracking by finite element analysis. The material and diameter of the pipe were changed to improve this defect, and the applied torque was adjusted. In addition, the bending value of the pipe was adjusted to minimize the fatigue accumulation due to pulsating pressure. As a result, no cracks occurred on the heat exchanger via the ground test after the installation of an improved pipe under the same conditions.

Effects of Co-Existent Additives and the Role of Reacted Surface Film on the Friction with an Organo-Molybdenum Compound

  • Kim, Young-Hwan
    • Tribology and Lubricants
    • /
    • v.10 no.4
    • /
    • pp.43-50
    • /
    • 1994
  • In order to elucidate the effects of co-existing additives (S$_{8}$, TBP: Tri butyl phosphate, ZnDTP: Zinc-dialkyl dithiophosphate) and the role of reacted surface film on the friction behavior of MoDTP (molybdenum dialkyl dithiophosphate), a friction experiment using a dual circular pipe edge surface type friction tester and XPS (X-ray photoelectronic spectrum) surface analysis were conducted. Friction reduction with MoDTP lubricant was proved to be greatly influenced by co-existing additive species. It was dependent on the properties of the film formed through the reaction between the additive and the surface. Phosphate film reduced the friction coefficient of MoDTP through suppression of diffusion of Mo compounds towards the metal substrate. On the other hand, sulfate film, which is inherently rich in lattice defects, did not lead to any appreciable friction reduction with MoDTP since the diffusion of the Mo compound towards the metal substrate was not effectively suppressed. With ZnDTP additive, the sulfide film formed through decomposition greatly influenced the lubricating performance of MoDTP. As such, properties of surface films formed from additives were proved to yield significant influence on the lubrication performance of MoDTP.