• 제목/요약/키워드: Lowest Resolution

검색결과 120건 처리시간 0.029초

수술실 간호사의 인간관계 만족도와 저해요인에 관한 연구 (A Study on the Job-Santisfacion and Its Depressive Facors in Human Relation Among Operation Room Nurses)

  • 조미자
    • 대한간호
    • /
    • 제32권4호
    • /
    • pp.48-62
    • /
    • 1993
  • This study was done for the purpose of analyzing the job-satisfaction and its depressive factors in human relation of operating room nurses of university hospital. Therfore, it makes an offer the basic data to help the resolution and prevention of the problems in operating room nurses. Furthermore, this study was conducted in order to find out some kinds of scientific data for the better control of depressive factors of job-satisfaction expressed by the operating room nurses. The structred questionaire reports of 246 operating room nurses who were employed in 5 different university hospitals which have over 1, 000 beds located in Seoul, Korea were used, which wer collected from August 24th to August 30th of 1992. The author visited supervisors of operating room in each university hospital and explained the aim of this study. The most of them(90.0%) answered to the questionaires. Analysis of the collected data were done by mean, standard deviation, percentage, t-test, F-test, Q-test, correlation analysis, one-way ANOVA.and stepwise multiple regression analysis. Major findings of this study were as follows: 1. The job of the operating room nurses were remarkably related with the satisfaction in human relation, which was defined as the behavioral job with thoughtful action rather than with mechanical action. However, the degree of satisfaction in human relation with personnel in other departments was found to be the lowest and its the main depressive factors were appeared due to the absence of interaction and uncooperative attitudes. Therefore, it was required that the members of other job need more cooperative attitude to the actual works in the operating room nurses. 2. The depressive factors in the satisfaction degree of human relation with offical seniors wer significantly related with their irresponsibility and partialness. Moreover, the job attitude of the operating room nurses is abundantly required to be improved, 3. The depressive factors in the satisfaction of human relation with medical doctors were significantly related with their insincerity and the class-consciousness. It is clearly suggested that the medical doctors do more cooperative behaviors for the jobs of the operating room without the suggested that the medical doctors do more cooperative behaviors for the jobs of the operating room without the superiority feeling of class-consciousness. 4. There was a significantly positive association between the satisfaction degree of human relation of the nurses with the following charateristics. (1) The registered nurses which had a tendency to be satisfied about the registered nurses' job. (2) The registered nurses which had a tendency to be a technique-aptitued in the motivation of the registered nurses'job. (3) The registered nurses which had a tendency to be satisfied about the total hospital working carrier and the aspects of old ages. Finally, these findings indicated that the operating room nurses should require the professional education courses associated with a high-development techniques and setisfaction in their jobs.

  • PDF

디지털 흉부영상에서 자동노출제어 및 감도변화를 이용한 영상품질의 정량적인 평가 (Quantitative Evaluation of Image Quality using Automatic Exposure Control & Sensitivity in the Digital Chest Image)

  • 이진수;고성진;강세식;김정훈;김동현;김창수
    • 한국콘텐츠학회논문지
    • /
    • 제13권8호
    • /
    • pp.275-283
    • /
    • 2013
  • 자동노출제어장치를 사용하는 흉부 후전 검사는 이온전리조의 선택에 따라 환자가 받는 피폭선량이 달라진다. 본 논문에서는 자동노출제어장치의 이온전리조의 선택에 따른 최적의 진단 영상을 획득하면서 피폭선량을 최소화하는 방안에 대해 연구하였다. 실험방법은 흉부 후전 검사와 동일한 조건으로 자동노출제어장치의 이온전리조 선택과 감도변화에 따라 실험하였다. 이온전리조의 상단 2개, 하단 1개의 센서를 on/off 선택에 따라 7가지의 경우로 나누어 각각 5회씩 측정하여 평균값을 구하고 피폭선량을 산출하였다. 영상평가는 변조전달함수, 최대신호 대 잡음비, 평균제곱근, 신호 대 잡음비, 대조도 대 잡음비, 평균대표준편차비를 각각 측정하여 평가를 시행하였다. 실험결과 피폭선량 평가에서 이온전리조 상단 2개를 선택한 경우가 다른 조합에 비해 가장 낮은 선량을 나타내었고, 해상력 평가결과로는 감도 625(High)에서 상단2개를 선택한 영상이 두 번째로 높은 공간주파수 1.343 lp/mm를 나타내었다. 상단 2개를 선택한 영상의 평균제곱근 결과값이 두 번째로 낮게 나타났으며, 신호 대 잡음비, 대조도 대 잡음비, 평균 대 표준편차비는 두 번째로 높은 결과값을 나타내었다. 그리고 감도가 증가함에 따라 피폭선량은 감소하였으며, 영상품질 측면에서도 보다 우수한 영상을 얻을 수 있었다. 따라서 피폭선량을 최소화하고, 최적의 의료 영상을 얻기 위해서는 감도 625(High)에서 이온전리조 상단 2개를 선택하는 것이 임상적으로 유용할 것으로 사료된다.

KMT-2018-BLG-0029LB: A VERY LOW MASS-RATIO Spitzer MICROLENS PLANET

  • Gould, Andrew;Ryu, Yoon-Hyun;Novati, Sebastiano Calchi;Zang, Weicheng;Albrow, Michael D.;Chung, Sun-Ju;Han, Cheongho;Hwang, Kyu-Ha;Jung, Youn Kil;Shin, In-Gu;Shvartzvald, Yossi;Yee, Jennifer C.;Cha, Sang-Mok;Kim, Dong-Jin;Kim, Hyoun-Woo;Kim, Seung-Lee;Lee, Chung-Uk;Lee, Dong-Joo;Lee, Yongseok;Park, Byeong-Gon;Pogge, Richard W.;Beichman, Charles;Bryden, Geoff;Carey, Sean;Gaudi, B. Scott;Henderson, Calen B.;Zhu, Wei;Fouque, Pascal;Penny, Matthew T.;Petric, Andreea;Burdullis, Todd;Mao, Shude
    • 천문학회지
    • /
    • 제53권1호
    • /
    • pp.9-26
    • /
    • 2020
  • At q = 1.81 ± 0.20 × 10-5, KMT-2018-BLG-0029Lb has the lowest planet-host mass ratio q of any microlensing planet to date by more than a factor of two. Hence, it is the first planet that probes below the apparent "pile-up" at q = 5-10 ×10-5. The event was observed by Spitzer, yielding a microlens-parallax πE measurement. Combined with a measurement of the Einstein radius θE from finite-source effects during the caustic crossings, these measurements imply masses of the host Mhost = 1.14+0.10-0.12 M and planet Mplanet = 7.59+0.75-0.69 M, system distance DL = 3.38+0.22-0.26 kpc and projected separation a = 4.27+0.21-0.23 AU. The blended light, which is substantially brighter than the microlensed source, is plausibly due to the lens and could be observed at high resolution immediately.

Influence of Iodinated Contrast Media and Paramagnetic Contrast Media on Changes in Uptake Counts of 99mTc

  • Cho, Jae-Hwan;Lee, Jin-Hyeok;Park, Cheol-Soo;Lee, Sun-Yeob;Lee, Jin;Moon, Deog-Hwan;Lee, Hae-Kag
    • Journal of Magnetics
    • /
    • 제19권3호
    • /
    • pp.248-254
    • /
    • 2014
  • The purpose of this study is to figure out how uptake counts of technetium ($^{99m}Tc$) among radioisotopes in the human body are affected if computed tomography (CT), magnetic resonance imaging (MRI) and isotope examination are performed consecutively. $^{99m}Tc$ isotope material, iodinated contrast media for CT and paramagnetic contrast media for magnetic resonance (MR) were used as experimental materials. First, $^{99m}Tc$ was added to 4 cc normal saline in a test tube. Then, 2 cc of CT contrast media such as $Iopamidol^{(R)}$ and $Dotarem^{(R)}$ were diluted with 2 cc normal saline, and 2cc of MRI contrast media such as $Primovist^{(R)}$ and $Gadovist^{(R)}$ were diluted with 2 cc normal saline. Each distributed contrast media was a total of 4 cc and included 10m Ci of $^{99m}Tc$. A gamma camera, a LEHR (Low energy high resolution) collimator and a pin-hole collimator were used for image acquisition. Image acquisition was repeated a total of 6 times and 120 frames were obtained and uptake counts of $^{99m}Tc$ were measured (from this procedure). In this study, as a result of measuring the uptake counts of $^{99m}Tc$ using the LEHR collimator, the uptake counts were less measured in all contrast media than normal saline as a reference. In particular, the lowest uptake counts were measured when $Gadovist^{(R)}$, contrast media for MRI, was used. However, the result of measuring the uptake counts of $^{99m}Tc$ using the pin-hole collimator showed higher uptake counts in all contrast media, except for $Iopamidol^{(R)}$, than normal saline as a reference. The highest uptake counts were measured particularly when $Primovist^{(R)}$, contrast media for MRI, was used. In performing the gamma camera examination using contrast media and $^{99m}Tc$, it is considered significant to check the changes in the uptake counts to improve various diagnosis values.

직접 디지탈 방사선 촬영시스템과 Ektaspeed 및 Ektaspeed Plus 필름을 이용한 방사선 사진용 디지탈 영상시스템과의 비교 연구 (COMPARATIVE STUDY OF DIRECT DIGITAL RADIOGRAPHIC SYSTEM WITH FILM-BASED DIGITAL IMAGING SYSTEM USING EKTASPEED AND EKTASPEED PLUS FILM)

  • 도정주;김은경
    • 치과방사선
    • /
    • 제25권1호
    • /
    • pp.51-70
    • /
    • 1995
  • The purpose of this investigation was to compare the direct digital radiographic system with film-based digital imaging system using Ektaspeed and Ektaspeed Plus film with respect to image characteristics and detectability and evaluate the sensor noise with the use of subtraction method. Direct digital radiographic system which used was Sens-A-Ray system(Regam Medical Systems, Sundsvall, Sweden) and film-based digital imaging system was composed of Macintosh II ci computer, high resolution Sony XC-77 CCD camera and intraoral x-ray film(Kodak Ektaspeed film, Kodak Ektaspeed Plus film). Images were taken by using CCD sensor of Sens-A-Ray system, Ektaspeed film and Ektaspeed Plus film with variable exposure time(0.06s, 0.1s, 0.16s, 0.2s, 0.3s, 0.4s, 0.5s, 0.6s, O.8s, LOs), 5 times at each exposure time. And then ektaspeed films and ektaspeed plus films were digitized using CCD camera. Image groups were divided into 3 groups; Sens-A-Ray group(direct digital radiographic system), Ektaspeed group and Ektaspeed Plus group (film-based digital imaging system) They were assessed by the following three aspects; image density, image contrast and detectability and sensor noise of Sens-A-Ray system was also evaluated. The results were as follow : 1. S group showed higher density than E , EP group except at the low exposure time(p<0.01). 2. S group showed higher contrast than E,EP group except at the high exposure time(p<0.01). 3. All groups showed good detectability at the each proper exposure time. Lowest exposure time which shows maximum detectability in S,EP group(0.5s) was lower than that in E group(0.6s). 4. Sensor noise of Sens-A-Ray system generally increased according to exposure time. On the basis of the above results, it was considered that Sens-A-Ray system could show higher speed, higher contrast than Ektaspeed, Ektaspeed Plus film except at too high and low exposure time and the same detectability as the conventional intraoral film.

  • PDF

Evaluation of the KASI Detector Performance Test System Using an Andor iKon M CCD Camera

  • Yu, Young Sam;Kim, Jinsol;Park, Chan;Jeong, Woong-Seob;Kim, Minjin;Choi, Seonghwan;Park, Sung-Joon
    • Journal of Astronomy and Space Sciences
    • /
    • 제35권3호
    • /
    • pp.201-210
    • /
    • 2018
  • The characterization of detectors installed in space- and ground-based instruments is important to evaluate the system performance. We report the development of a detector performance test system for astronomical applications using the Andor iKon M CCD camera. The performance test system consists of a light source, monochromator, integrating sphere, and power meters. We adopted the Czerny-Tuner monochromator with three ruled gratings and one mirror, which covers a spectral range of 200-9,000 nm with a spectral resolution of ~1 nm in the visible region. Various detector characteristics, such as the quantum efficiency, sensitivity, and noise, can be measured in wide wavelength ranges from the visible to mid-infrared regions. We evaluated the Korea Astronomy and Space Science Institute (KASI) detector performance test system by using the performance verification of the Andor iKon-M CCD camera. The test procedure includes measurements of the conversion gain ($2.86e^-/ADU$), full well capacity ($130K\;e^-$), nonlinearity, and pixel defects. We also estimated the read noise, dark current, and quantum efficiency as a function of the temperature. The lowest measured read noise is $12e^-$. The dark current at 223 K was determined to be $7e^-/s/pix$ and its doubling temperature is $5.3^{\circ}C{\pm}0.2^{\circ}C$ at an activation energy of 0.6 eV. The maximum quantum efficiency at 223 K was estimated to be $93%{\pm}2%$. We proved that the quantum efficiency is sensitive to the operating temperature. It varies up to 5 % in the visible region, while the variation increases to 30 % in the near-infrared region. Based on the comparison of our results with the test report by the vendor, we conclude that our performance test results are consistent with those from the vendor considering the test environment. We also confirmed that the KASI detector performance test system is reliable and our measurement method and analysis are accurate.

Detection of Precise Crop Locations under Vinyl Mulch using Non-integral Moving Average Applied to Thermal Distribution

  • Cho, Yongjin;Yun, Yeji;Lee, Kyou-Seung;Lee, Dong-Hoon
    • Journal of Biosystems Engineering
    • /
    • 제42권2호
    • /
    • pp.117-125
    • /
    • 2017
  • Purpose: Damage to pulse crops by wild birds is a serious problem. The damage is to such an extent that the rate of damage during the period between seeding and cotyledon stages reaches 54.6% on an average. In this study, a crop-position detection method was developed wherein infrared (IR) sensors were used to determine the cotyledon position under a vinyl mulch. Methods: IR sensors that helped measure the temperature were used to locate the cotyledons below the vinyl mulch. A single IR sensor module was installed at three locations of the crops (peanut, red lettuce, and crown daisy) in the cotyledon stage. The representative thermal response of a $16{\times}4$ pixel area was detected using this sensor in the case where the distance from the target was 25 cm. A spatial image was applied to the two-dimensional temperature distribution using a non-integral moving-average method. The collected data were first processed by taking the moving average via interpolation to determine the frame where the variance was the lowest for a resolution unit of 1.02 cm. Results: The temperature distribution was plotted corresponding to a distance of 10 cm between the crops. A clear leaf pattern of the crop was visually confirmed. However, the temperature distribution after the normalization was unclear. The image conversion and frequency-conversion graphs were obtained based on the moving average by averaging the points corresponding to a frequency of 40 Hz for 8 pixels. The most optimized resolutions at locations 1, 2, and 3 were found on 3.4, 4.1, and 5.6 Pixels, respectively. Conclusions: In this study, to solve the problem of damage caused by birds to crops in the cotyledon stage after seeding, the vinyl mulch is punched after seeding. The crops in the cotyledon stage could be accurately located using the proposed method. By conducting the experiments using the single IR sensor and a sliding mechanical device with the help of a non-integral interpolation method, the crops in the cotyledon stage could be precisely located.

한국노인과 미국이민 한국노인의 건강증진 생활양식, 자아존중감 및 자기효능감에 관한 연구 (A Comparative study on Health Promoting Lifestyle Patterns, Self-esteem and Self-efficacy between Korean Elderly and Korean-American Elderly)

  • 송경애;조옥희;문정순;정승교
    • 한국보건간호학회지
    • /
    • 제14권2호
    • /
    • pp.355-371
    • /
    • 2000
  • The purpose of this study was to explore and compare health-promoting behaviors and its relationships with associated variables between Korean elderly and Korean-American elderly. Study instruments were questionnaire that consisted of socioeconomic characteristics, health-promoting lifestyle patterns. self-esteem and self-efficacy. Data were collected from convenient sample of 150 Korean elderly and 110 Korean-American elderly recruited from senior centers. Collected data were analyzed by t-test. ANOVA, and Pearson correlation coefficients. The results are followings : 1. In religion, $32.7\%$ of Korean elderly were protestant. while $32.7\%$ of Korean-American. elderly were protestant. $61.3\%$ of Korean elderly were living with their children, and only $17.3\%$ of Korean-American elderly were living with their children. 2. There was no significant difference in the mean HPLP score in two groups. but Korean elderly showed higher practices in health responsibility. exercise. and stress management than that of Korean-American elderly. The subjects showed the highest practices in nutrition(3.14. 3.01), and the lowest practices in exercise (2.14, 1.92). 3. The mean HPLP score of Korean elderly was 2.63, showing significant relationships with age. education and economic status. the score of Korean-American elderly was 2.54, showing significant relationships with education. 4. Self-esteem score of Korean elderly was 2.72 and Korean-American elderly was 2.73. there was no significant difference in two groups. The score of self-esteem of Korean-American elderly was showing significant relationships with presence of spouse. 5. Self-efficacy score of Korean elderly was 3.27 and Korean-American elderly was 3.21. there was no significant difference in two groups. The score of self-efficacy of both groups were showed significant relationships with education. 6. The HPLP of Korean and Korean-American elderly showed(r=.24. r= .49) positive correlations with self-esteem had positive correlations with self-efficacy(r=.42. r=.28). To draw concrete resolution for health promotion of Korean and Korean-American elderly. this study suggests followings for future research : 1. Nursing interventions enhancing exercise and stress management of the elderly must be provided. Especially developing and adopting feasible exercise programs for Korean-American elderly is highly needed. 2. Identifying the influences of culture on their practices of health-promoting lifestyle patterns among Korean. Korean-American and other racial elderly groups.

  • PDF

서울 대기 중 PM2.5 내 OC와 EC로부터 SOC 추정방법의 비교 평가 (Validation for SOC Estimation from OC and EC concentration in PM2.5 measured at Seoul)

  • 유하영;김기애;김용표;정창훈;신혜정;문광주;박승명;이지이
    • 한국입자에어로졸학회지
    • /
    • 제16권1호
    • /
    • pp.19-30
    • /
    • 2020
  • The organic carbon in the ambient particulate matter (PM) is divided into primary organic carbon (POC) and secondary organic carbon (SOC) by their formation way. To regulate PM effectively, the estimation of the amount of POC and SOC separately is one of important consideration. Since SOC cannot be measured directly, previous studies have evaluated determination of SOC by the EC tracer method. The EC tracer method is a method of estimating the SOC value from calculating the POC by determining (OC/EC)pri which is the ratio of the measured values of OC and EC from the primary combustion source. In this study, three different ways were applied to OC and EC concentrations in PM2.5 measured at Seoul for determining (OC/EC)pri: 1) the minimum value of OC/EC ratio during the measurement period; 2) regression analysis of OC vs. EC to select the lower 5-20% OC/EC ratio; 3) determining the OC/EC ratio which has lowest correlation coefficient value (R2) between EC and SOC which is reported as minimum R squared method (MRS). Each (OC/EC)pri ratio of three ways are 0.35, 1.22, and 1.77, respectively from the 1 hourly data. We compared the (OC/EC)pri ratio from 1hourly data with 24 hourly data and revealed that (OC/EC)pri estimated from 24 hourly data had twice larger than 1hourly data due to the low time resolution of sampling. We finally confirmed that the most appropriate value of (OC/EC)pri is that calculated by a regression analysis of 1 hourly data and estimated SOC amounts at PM2.5 of the Seoul atmosphere.

Measurement of Fractional Exhaled Nitric Oxide in Stable Bronchiectasis

  • Cho, Young-Jae;Lim, Hyo-Jeong;Park, Jong Sun;Lee, Jae Ho;Lee, Choon-Taek;Yoon, Ho Il
    • Tuberculosis and Respiratory Diseases
    • /
    • 제74권1호
    • /
    • pp.7-14
    • /
    • 2013
  • Background: Fractional exhaled nitric oxide (FeNO) can be measured easily, rapidly, and noninvasively for the assessment of airway inflammation, particularly mediated by eosinophil, such as asthma. In bronchiectasis (BE), the pathogenesis has been known as chronic airway inflammation and infection with abnormal airway dilatation; however, there are little studies to evaluate the role of FeNO in BE. Methods: From March 2010 to February 2012, 47 patients with BE, diagnosed by high resolution computed tomography (HRCT), performed FeNO, compared with asthma and chronic obstructive pulmonary disease (COPD). All patients carried out a complete blood count including eosinophil count, chemistry, sputum examination, and spirometry, if indicated. A retrospective analysis was performed to elucidate the clinical role of FeNO in BE patients. Results: The mean FeNO levels in patients with BE was $18.8{\pm}1.5$ part per billion (ppb), compared to $48.0{\pm}6.4$ and $31.0{\pm}4.3$ in those with asthma and COPD, respectively (p<0.001). The FeNO levels tended to increase along with the disease severity scores by HRCT; however, it was statistically not significant. FeNO in BE with a co-infection of nontuberculous mycobacteria was the lowest at $17.0{\pm}3.5$ ppb among the study population. Conclusion: FeNO in BE was lower than other chronic inflammatory airway diseases, particularly compared with asthma. For clinical application of FeNO in BE, more large-scaled, prospective studies should be considered.