• Title/Summary/Keyword: Lower distortion

Search Result 282, Processing Time 0.025 seconds

A New Steganographic Method with Minimum Distortion (최소 왜곡을 위한 새로운 스테가노그래피 방법)

  • Zhang, Rongyue;Md, Amiruzzaman;Kim, Hyoung-Joong
    • 한국정보통신설비학회:학술대회논문집
    • /
    • 2008.08a
    • /
    • pp.201-204
    • /
    • 2008
  • In this paper a new steganographic method is presented with minimum distortion. This paper focused on DCT rounding error and optimized that in a very easy way, resulting stego image has less distortion than other existing methods. The proposed method compared with F5 steganography algorithm, and the proposed method achieved better performance. This paper considered the DCT rounding error for lower distortion with possibly higher embedding capacity.

  • PDF

Analysis of Amplitude Distortion in Super Wide-Band AM Signal Transmission (초광대역 AM 신호전송에서의 진폭왜율해석)

  • 이충웅
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.8 no.3
    • /
    • pp.27-32
    • /
    • 1971
  • This paper presents the analysis of the amplitude distortion occurring in the transmission of super wideband AM signal when the amplitude and phase variations of the upper and lower sidebands of the AM signal are symmetrical, and odd symmetrical with respect to the carrier. It is shown that the case where the amplitude variations of the upper and lower sidebands of AM signal are symmetrical with respect to the carrier while the phase variations of the upper and lower sidebands are odd symmetrical with respect to the carrier induce, no amplitude distortion in AM signal transmission.

  • PDF

A RADIOGRAPHIC METHOD FOR DETERMINING THE ACTUAL TOOTH LENGTH (치아장경 측정을 위한 방사선학적 방법)

  • Nah Kyung-Soo;Cho Bong-Hae
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.25 no.2
    • /
    • pp.281-286
    • /
    • 1995
  • Tooth length determination is a crucial step in endodontic treatment. Traditionally, radiographs are used to confirm working length of the root length. This study was performed to evaluate the radiographic distortion(magnification) and calculate correction coefficients for the object-film distance. Ninty-six radiographs were made of eight extracted teeth(two upper first premolars, two lower first premolars, two upper first molars, and two lower first molars) by using the 16 inch long cone paralelling techniques with 1mm interval from 5 to 16mm tooth-film distance. The results were as follows. 1. The least mean radiographic distortion from 5 to 16mm tooth-film distance was 2.42±0.68%(the length of mesiobuccal cusp-mesial root of lower first molars), the greatest distortion was 4.74±1.36%(the length of mesiobuccal cusp-mesiobuccal root of upper first molars). 2. The greatest correction coefficient was 0.986(the mesiobuccal cusp-mesial root of lower first molars, the lowest one was 0.937(the mesiobuccal cusp-mesiobuccal root of upper first molars).

  • PDF

Securitization and Monitoring Incentives (자산유동화와 모니터링 유인간의 관계)

  • Han, Jae-Joon
    • Journal of the Korean Operations Research and Management Science Society
    • /
    • v.37 no.2
    • /
    • pp.17-29
    • /
    • 2012
  • We examine a mortgage bank's incentive distortion problem when the bank sells its existing loan through MBS(Mortgage-Backed Security), considering the mortgage market structure and varying investors' risk attitude. Main findings in our comparative statics are the followings. The bank's monitoring incentive on the loan sold is distorted downwards when the deposit interest rate is lower than the coupon rate of MBS. Credit enhancement associated with the loan sale may mitigate the incentive distortion problem. However, the downward distortion of monitoring incentive does not disappear unless the credit enhancement, a loan guarantee, is provided up to 100%. Finally as the investors' risk preference changes from risk-neutral to risk-averse type, the incentive distortion problem becomes more severe. At the end, we recommend the introduction of covered bond in order to mitigate the incentive distortion problem, which is inevitable to current pass-through MBS.

The Effect of Inlet Distortion on a Centrifugal Compressor (입구 불균일 유동에 의한 원심압축기 스톨에 관한 실험적 연구)

  • Park, Jae-Hyoung;Kang, Shin-Hyoung
    • 유체기계공업학회:학술대회논문집
    • /
    • 2003.12a
    • /
    • pp.476-481
    • /
    • 2003
  • In this paper, the effect of circumferential inlet distortion on performance and stall has been experimentally investigated in a high-speed centrifugal compressor, comparing distorted cases with undistorted one. The performance of compressor was slightly deteriorated by defect of inlet static pressure which is caused by the circumferential inlet distortion. As stall was fully developed the inlet distortion did not affect the number of stall cell and the propagation velocity. It also did not affect stall inception at 40,000 and 50,000 rpm. However stall occurred at the lower flow rate for distorted flow at 60,000 rpm. For 50,000 rpm a unexpected phenomenon occurred : stall occurred first and then it disappeared.

  • PDF

High Performance Piezoelectric Microspeakers and Thin Speaker Array System

  • Kim, Hye-Jin;Koo, Kun-Mo;Lee, Sung-Q;Park, Kang-Ho;Kim, Jong-Dae
    • ETRI Journal
    • /
    • v.31 no.6
    • /
    • pp.680-687
    • /
    • 2009
  • This paper reports on an improved piezoelectric microspeaker with a high sound pressure level of 90 dB, a total harmonic distortion of less than 15%, and coherence higher than 0.9. The fabricated Pb(Zr,Ti)$O_3$ (PZT) microspeakers have a thickness of only 1 mm including the speaker frame and an active area of 18 mm${\times}$20 mm. To achieve higher sound pressure and lower distortion, the PZT piezoelectric microspeaker has a well-designed speaker frame and a piezoelectric diaphragm consisting of a tilted PZT membrane and silicone buffer layer. From the simulation and measurement results, we confirmed that the silicon buffer layer can lower the first resonant frequency, which enhances the microspeaker's sound pressure at a low frequency range and can also reduce useless distortion generated by the harmonics. The fabricated PZT piezoelectric microspeakers are implemented on a multichannel speaker array system for personal acoustical space generation. The output sound pressure at a 30 cm distance away from the center of the speaker line array is 15 dB higher than the sound pressure at the neighboring region 30 degrees from the vertical axis.

A Study on Image Distortion Correction for Gobo Lighting Optical System (고보 조명 광학계의 이미지 왜곡 보정에 관한 연구)

  • Gyu-Ha Kim;Ji-Hwan Lee;Chang-Hun Lee;Mee-Suk Jung
    • Korean Journal of Optics and Photonics
    • /
    • v.34 no.2
    • /
    • pp.61-65
    • /
    • 2023
  • This paper studies a method of applying pre-distortion to the image mask of the gobo illumination optical system to correct an irradiated image and irradiate a clear image. In the case of the gobo illumination optical system, since it is generally irradiated with a tilt, distortion in the upper and lower directions occurs severely in the image. To solve this problem, the correction coordinates of the image were derived using a proportional equation, and the distortion was corrected by applying them to the image mask. As a result, it was confirmed that the distortion was reduced by 64.5% compared to the case of using the existing image mask.

Scheme to Improve the Line Current Distortion of PFC Using a Predictive Control Algorithm

  • Kim, Dae Joong;Park, Jin-Hyuk;Lee, Kyo-Beum
    • Journal of Power Electronics
    • /
    • v.15 no.5
    • /
    • pp.1168-1177
    • /
    • 2015
  • This paper presents a scheme to improve the line current distortion of power factor corrector (PFC) topology at the zero crossing point using a predictive control algorithm in both the continuous conduction mode (CCM) and discontinuous conduction mode (DCM). The line current in single-phase PFC topology is distorted at the zero crossing point of the input AC voltage because of the characteristic of the general proportional integral (PI) current controller. This distortion degrades the line current quality, such as the total harmonic distortion (THD) and the power factor (PF). Given the optimal duty cycle calculated by estimating the next state current in both the CCM and DCM, the proposed predictive control algorithm has a fast dynamic response and accuracy unlike the conventional PI current control method. These advantages of the proposed algorithm lower the line current distortion of PFC topology. The proposed method is verified through PSIM simulations and experimental results with 1.5 kW bridgeless PFC (BLPFC) topology.

The Effect of Inlet Distorted Flow on Steady and Unsteady Performance of a Centrifugal Compressor (입구 비 균일 유동이 원심압축기의 정상 및 비정상 성능에 미치는 영향)

  • Kang Shin-Hyoung;Park Jae-Hyoung
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.29 no.9 s.240
    • /
    • pp.971-978
    • /
    • 2005
  • Effects of inlet distorted flow on performance, stall and surge are experimentally investigated for a high-speed centrifugal compressor. Tested results for the distorted inlet flow cases are compared with the result of the undistorted one. The performance of compressor is slightly deteriorated due to the inlet distortion. The inlet distortion does not affect the number of stall cell and the propagation velocity. It also does not change stall inception flow rate. However, as the distortion increases, stall starts at the higher flow rate for low speed and at the lower flow rate for high speed. For 50,000 rpm stall occurrs as the flow rate decreases, however disappears fur the smaller flow rate. This is due to the interaction of surge and stall. After the stall and surge interact, the number of stall cell decreases.

Analysis of Total Harmonic Distortion in Microspeaker Considering Coupling Effect (연성 효과를 고려한 마이크로스피커 왜율분석)

  • Kwon, Joong-Hak;Kim, Kwang-Suk;Bang, Ki-Chang;Hwang, Sang-Moon
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.18 no.4
    • /
    • pp.473-479
    • /
    • 2008
  • With the advent of mobile phone, digital multimedia broadcasting(DMB) service is to be realized for multimedia data communication. For an acoustic part, a smaller and lighter microspeaker is also soon to be realized as an MP3 song player and a speakerphone. Sound quality in the microspeaker is becoming more important in mobile phones. It is evaluated by total harmonic distortion(THD). THD is the proportion of higher order frequencies output response to sinusoidal input signal. It is affected by uneven magnetic distribution and nonlinear response of diaphragm. In this paper, harmonic distortion is analyzed by considering magnetic and mechanical coupling effects. Simulated results of THD are compared with experimental data. Results show that THD in lower frequency range is higher due to high displace on voice coil and high mechanical response of high order frequency.