• Title/Summary/Keyword: Lower complete denture

Search Result 50, Processing Time 0.024 seconds

A CLINICAL STUDY ON THE SATISFACTION OF COMPLETE DENTURE PATIENTS (총의치 환자의 만족도에 대한 연구)

  • Kim, Hyung-Woo;Kim, Chang-Whe;Kim, Yung-Soo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.33 no.3
    • /
    • pp.440-452
    • /
    • 1995
  • A success of complete denture prosthesis can be determined by the satisfaction degree of the dentist and the patient. There are many factors influencing on the satisfaction of the complete denture patients. The purpose of this study is to analyze the correlation between the masticatory satisfaction and clinical evaluation, and the speech satisfaction and clinical evaluation in complete denture patients. 79 patients(total 119 complete dentures) were examined in this study who were treated in Seoul National University Dental Hospital. Through clinical evaluation, 2 examiners evaluated sex, age, edentulous period, the years of having used present complete denture, the number of the previous dentures, the state of the opposite arch, retention, stability, support, occlusion, vertical dimension of the complete denture and the condition of the residual alveolar ridge. Through questionnaires concerned with mastication and speech, examiners evaluate the satisfaction degree of the patients. This study led to the conclusion that : 1. The satisfaction degree of the mastication was lower in older patients(p<0.001) and in patients whose present complete denture period was shorter(p<0.05). The satisfaction degree of the mastication in male was higher than in female patients(p<0.01). 2. The satisfaction degree of the mastication was high when the retention of the complete denture was good(p<0.05), and when the condition of the residual alveolar ridge was good(p<0.05). 3. The satisfacion degree of the speech was high when the retention of the complete denture was good(p<0.01). 4. The satisfaction degree of the mastication was higher in patients with upper and lower complete denture than in patients with single complete denture whose oppsite arch was unilateral partial denture(p<0.05).

  • PDF

THREE DIMENSIONAL FINITE ELEMENT ANALYSIS OF MANDIBULAR STRESSES OF COMPLETE DENTURE OCCLUSION (하악 총의치 교합형태에 따른 하부조직에 미치는 교합력 양태의 3차원적 유합요소법 해석)

  • Lee Young-Soo;Yoo Kwang-Hee
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.30 no.2
    • /
    • pp.286-318
    • /
    • 1992
  • The objective of preventive dentistry is the maintenance of a healthy dentition for the life of a patient. Unfortunately, if an individual has not received the benefit of a comprehensive program of preventive dentistry and has finally reached the edentulous state, as a consequence, he receives a set of complete denture. Dentures are mechanical devices and subject to the principles of mechanics. In some cases, the general health and nutritional status of the patient are felt to be the causative factors. But, the most important thing in residual ridge resorption is felt to be caused by the unequal distribution of functional forces. This study was to analyze mandibular stresses of complete denture occlusion by three dimensional finite element method. The results were as follows ; 1. As deformation and stress distribution of the complete denture of the mandible were concentrated on the upper lingual side of the mandible, alveolar ridge resorption of the mandible occurred from lingual side to labio-buccal side. 2. Analyzing by three dimensional F. E. M., the mandible is a very effective form for tolerating stress and deformation biomechanically. 3. According to the concentration of stress distibution in the upper buccal side of the lower posteriors, buccal shelf area must be a primary stress bearing area in the lower complete denture. 4. Lower complete denture moved horizontally to the balancing side under lateral occlusal force. 5. Bilateral balanced occlusion should be constructed in the complete denture for denture stability, especially in the protrusive movement. 6. Physical property of the denture base material was as important for stress distribution in the denture base as or even more than that in the mandible. 7. Impression technique is very important because of most of stress was concentrated between them due to close contact of the mandible and the denture base.

  • PDF

Evaluation of fitness according to application of glass fiber reinforcement for lower jaw complete denture (하악 총의치 전용의 유리섬유 보강재 적용에 따른 적합도 비교 분석)

  • Kim, Dong-Yeon;Park, Jin-Young;Bae, So-Yeon;Kang, Hoo-Won;Kim, Ji-hwan;Kim, Woong-Chul
    • Journal of Technologic Dentistry
    • /
    • v.40 no.4
    • /
    • pp.201-207
    • /
    • 2018
  • Purpose: The purpose of this study is to evaluate the fitness of lower jaw compete denture with glass fiber. Methods: Lower jaw edentulous model was selected as the master model. Ten study models were produced using Type IV stone(n=10). Lower jaw trial dentures were produced by the wax denture base and artificial teeth. Conventional complete denture (CD) group was fabricated by excluding glass fiber reinforcement (n=5). Glass fiber complete denture (GD) group was fabricated with glass fiber reinforcement (n=5). The lower jaw trial complete denture was invested using a plaster. PMMA resin was injected and curing was performed. The CD and GD groups measured the fit using silicone replica technology. The measured data was verified by t-test. Results: The anterior area of the CD group showed the smallest value. There was a statistically significant difference in the anterior area of the CD group and the GD group (p<0.05), but there was no statistically significant difference in the posterior area (p>0.05). Conclusion : Complete denture with glass fiber showed low fitness and further study is needed to apply it clinically.

PSYCHOLOGICAL ASPECT OF PATIENT SATISFACTION AND ACCEPTANCE OF COMPLETE DENTURES (총의치 환자 만족도에 대한 정신의학적 측면)

  • Chung, Moon-Kyu;Lee, Suk-Won
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.37 no.4
    • /
    • pp.494-505
    • /
    • 1999
  • In spite of the progress in techniques and materials of the prosthodontic rehabilitation of patients with complete edentulous arches, prosthodontists still face patients' complaints about dissatisfaction and discomfort from their dentures. In the past several decades, prosthodontists tried to find the factors that influence the patient's satisfaction with dentures. However the results are contraversial especially with the psychological factor. In this study using 'patient denture satisfaction questionnaire' and Hopkins Symptom Checklist, we tried to find the correlation between the patient's denture satisfaction and the patient's psychological aspects. 23 complete edentulous patients who have visited the Department of Prosthodontics, Yonsei University Dental Hospital from September 1998 to June 1999 for complete denture treatment were asked to complete the questionnaires 4 to 6 weeks after the upper and lower complete delivery. After the measurement of validity of the questionnaires, correlations between the patient's general satisfaction with their new upper and lower complete dentures and the other satisfaction questions including the satisfactions with esthetics, retention, mastication, speech, comfort and other people's opinion and between the patient's general satisfaction with their new upper and lower complete dentures and the 5 symptoms of Hopkins Symptoms Checklist including somatic, obsessive-compulsive, interpersonal sensitivity, depression and anxiety were analyzed. Among the several satisfaction questionnaire items, comfort with the lower denture showed highest relation to the patient's general satisfaction with dentures. However, only the anxiety scale of Hopkins Symptoms Checklist among the other symptom scales was related to the patient's general satisfaction with dentures. The two questionaires used in this study turned out to be valid means of analyzing patient's denture satisfaction and psychological status before and after the complete denture treatment.

  • PDF

Factors influencing the frequency of denture adjustments after delivery of complete denture: a retrospective study (총의치 장착 후 의치 조정 횟수에 영향을 미치는 요인에 관한 후향적 연구)

  • Lee, Seungwon;Yoon, Joon-Ho;Yoo, Jin-Joo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.60 no.3
    • /
    • pp.239-245
    • /
    • 2022
  • Purpose. The purpose of this study was to analyze the frequency and duration of adjustments after delivery of complete denture according to age, sex, arch with complete denture, insurance coverage of a denture, type of antagonist, the experience of wearing denture, the period of edentulism, and the type of denture base. Materials and methods. For 5 years, medical records of patients aged 65 or older who had treated full dentures were assessed for the frequency and duration of follow-up visits after complete denture delivery. Statistical analysis was performed at the 5% level of significance to analyze the correlation between the frequency and duration of follow-up according to sex, insurance coverage, arch with the complete denture, type of denture base, type of antagonist, experience of wearing a denture, age, and healing period. Results. 247 complete dentures were included in this study. The median frequency of follow-up visits was 3, and the median duration of follow-up was 36 days. Lower dentures had significantly higher frequency of follow-up visits than upper dentures (P = .036). According to the type of antagonist, dentures opposing a complete denture had a significantly higher frequency of follow-up visits than dentures opposing a removable partial denture (P = .016). There was no statistically significant difference in the frequency and duration of adjustments after delivery of complete denture by age, sex, insurance coverage, healing period, the experience of wearing a denture, and type of denture base. Conclusion. Within the limitations of the present study, lower complete dentures or dentures opposing a complete denture had an increased frequency of follow-up visits.

Evaluation of trueness of maxillary and mandibular denture bases produced with a DLP printer by immersion in a constant temperature water bath (DLP 프린터로 제작한 상악 및 하악 의치상의 항온수조 침적에 따른 진실도(trueness) 평가)

  • Dong-Yeon Kim;Gwang-Young Lee
    • Journal of Technologic Dentistry
    • /
    • v.46 no.2
    • /
    • pp.28-35
    • /
    • 2024
  • Purpose: To evaluate the three-dimensional trueness of upper and lower denture bases produced using a digital light processing (DLP) printer and immersed in a constant-temperature water bath. Methods: An edentulous model was prepared and fitted with denture bases and occlusal rims manufactured using base plate wax. After scanning the model, denture bases, and occlusal rims, complete denture designs were created. Using the designs and a DLP printer, 10 upper and 10 lower complete dentures were manufactured. Each denture was scanned before (impression surface of upper denture base before constant temperature water bath [UBC] and impression surface of lower denture base before constant temperature water bath [LBC] groups) and after (impression surface of upper denture base after constant temperature water bath [UAC] and impression surface of lower denture base after constant temperature water bath [LAC] groups) immersion in the constant-temperature water bath. Scanned files were analyzed by comparing reference and scanned data, with statistical analysis conducted using the Kruskal-Wallis test (α=0.05). Results: Statistical analysis revealed no significant differences between the UBC and LBC groups, nor between the UAC and LAC groups (p>0.05). However, significant differences were observed between the UBC and UAC groups and between the LBC and LAC groups, i.e., before and after the constant-temperature water bath for both maxillary and mandibular denture bases (p<0.05). Conclusion: Denture bases not immersed in the constant-temperature water bath (UBC and LBC groups) exhibited error values within 100 ㎛, whereas those immersed in the water bath (UAC and LAC groups) showed error values exceeding 100 ㎛.

Three dimensional deformation of dry-stored complete denture base at room temperature

  • Lim, Seo-Ryeon;Lee, Joon-Seok
    • The Journal of Advanced Prosthodontics
    • /
    • v.8 no.4
    • /
    • pp.296-303
    • /
    • 2016
  • PURPOSE. The aim of this study was to evaluate whether there is any typical deformation pattern existing in complete denture when it was dried by using the 3D scanner and surface matching program. MATERIALS AND METHODS. A total of 28 denture bases were fabricated with heat curing acrylic resin (each 14 upper and lower denture bases), and 14 denture bases (each 7 upper and lower denture bases) were stored in the water bottle (water stored), and another 14 denture bases were stored in the air (dry stored). Each specimen was scanned at $1^{st}$ day after deflasking, $14^{th}$ day after deflasking, and $28^{th}$ day after deflasking, and digitalized. Three dimensional deformation patterns were acquired by comparison of the data within storage group using surface matching program. For evaluating differences between groups, these data were compared statisticallyusing Kruskal Wallis and Mann Whitney-U test (${\alpha}$=.05). RESULTS. When evaluating 3D deformation of denture base, obvious deformations were not found in maxillary and mandibular water storage group. However, in dry stored group, typical deformation pattern was detected as storage time passes. It occurred mostly in first two weeks. Major deformations were found in the bilateral posterior area in both maxillary and mandibular group. In maxillary dry stored group, a statistical significance was found. CONCLUSION. It was proved that in both upper and lower denture bases, dry storage caused more dimensional deformation than water storage with typical pattern.

Acoustic Characteristics of Patients with Maxillary Complete Dentures (상악 총의치 장착 환자 언어의 음향학적 특성 연구)

  • Ko, Sok-Min;Hwang, Byung-Nam
    • Speech Sciences
    • /
    • v.8 no.4
    • /
    • pp.139-156
    • /
    • 2001
  • Speech intelligibility in patients with complete dentures is an important clinical problem depending on the material used. The objective of this study was to investigate the speech of two edentulous subjects fitted with a complete maxillary prosthesis made of two different palatal materials: chrome-cobalt alloy and acrylic resin. Three patients with complete dentures in the experiment group and ten people in the controls groups participated in the experiment. CSL, Visi-Pitch were used to measure speech characteristics. The test words consisted of a simple vowel /e/, meaningless three syllabic words containing fricative, affricated and stops sounds, and sustained fricative sounds /s/ and /$\int$/. The analysis speech parameters were vowel and lateral formants, VOT, sound durations, sound pressure level and fricative frequency. Data analysis was conducted by a series of paired T-test. The findings like the following: (1) Vowel formant one of patients with complete denture is higher than that of the control group (p<0.05), while lateral formant three of patients with complete denture is lower than that of the control group (p<0.0l). (2) Patients with complete denture produced lower speech intelligibility with low fricative frequency (/$\int$/) than control group (p<0.0). The speech intelligibility of patients with metal prosthesis was higher than that of those with resin prosthesis (p<0.05). (3) Fricative, lateral and stop sound durations of patients with complete denture were longer than those of the control group (p<0.01 and p<0.05), respectively. Total sound durations of patients with metal prosthesis were similar to that of the control group (p<0.05), while those with resin prosthesis had a shorter duration (p<0.01). This implied that those with metal prosthesis had higher speech intelligibility than those with resin prosthesis. (4) Patients with complete denture had higher sound pressure levels /t/ and /c/ than the control group (p<0.01). However, sound pressure levels for /c/ of patients with metal prosthesis or resin prosthesis was similar to the control group (p<0.05). (5) Patients with complete denture had higher fundamental frequency than the control group (p<0.01).

  • PDF

Maxillary Resorption under Complete Dentures Opposing Mandibular Implant Supported Fixed Prosthesis: A Literature Review and Case Report (하악 임플란트 고정성 보철에 대합되는 상악 총의치 하방의 골흡수에 대한 고찰 및 증례보고)

  • Kim, Bo-Kuk;Kim, Yu-Lee
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.29 no.4
    • /
    • pp.426-433
    • /
    • 2013
  • When restoring edentulous patients with lower complete denture, the smaller supportive and retentive area of mandible can lead to poor support and stability, denture dislodgement and pain resulting discomfort. In this situation, implant prosthesis can improve esthetics, stability and occlusal force. Whereas, patients with a upper complete denture can adjust more easier because of palate. Therefore, it is suggested to rehabilitate fully edentulous patients with lower implant-supported, upper complete denture as one of the treatment options. So, we are going to report the case and literature review about how the lower implant prosthesis opposing to upper complete denture affects the bone resorption of maxillary residual ridge.

A COMPARATIVE ELECTROMYOGRAPHIC STUDY OF THE MASSETER AND ANTERIOR TEMPORAL MUSCLES DURING MASTICATORY FUNCTION OF SUBJECTS WITH NATURAL TEETH AND COMPLETE DENTURE WEARERS (유치악자와 총의치 장착자의 저작운동시 교근과 측두근의 근할성도에 관한 비교연구)

  • Choi, Seung-Hyun;Choi, Boo-Byung;Choi, Dae-Gyun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.29 no.1
    • /
    • pp.53-71
    • /
    • 1991
  • This study was performed to investigate the muscular activity of the complete denture wearers compare with subjects with natural teeth. For the study, 10 subjects with natural dentition and 18 upper and lower complete denture wearers selected and the Bio-electric Processor EM2(Myo-tronics Reaserch, Inc., U.S.A.) with the surface electrodes was used to record electromyographic activity from the right and left middle of masseter and anterior temporal muscles of each subject during mandibular postural rest position, tapping of teeth from postural rest position, maximal clench, and right and left gum and raw carrow chewing. This results of this study were as follows : 1. In mandibular postural rest position, the denture wearers produces high muscular activity in contrast to natural objects(P<0.05) but, there was no difference between the state of denture removal and insertion, and the muscle activity of the anterior temporal muscle was high than the middle of masseter muscle in natural objects and denture wearers. 2. In tapping of teeth, there was no difference in muscle activity between natural objects and the state of denture removal of denture wearers. 3. In maximal clench, there was markedly lower denture wearers than natural objects in muscle activity, and the ratio of mean voltages was about 36 percentages. 4. In gum and raw carrow chewing, the activity was lower than natural object, the ratio was about 59 percentages. 5. In chewing, the mean voltages of the middle of masster muscle on the chewing side was highest, followed by the anterior temporal on the chewing side, the anterior temporal and masster muscles on the non-chewing side.

  • PDF