• 제목/요약/키워드: Lower System

검색결과 11,098건 처리시간 0.043초

도시철도시스템의 요구사항체계 구축에 관한 연구 (A Study on System Requirement Structure of Urban Transit System)

  • 이우동
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2004년도 추계학술대회 논문집
    • /
    • pp.157-161
    • /
    • 2004
  • Urban transit is system that offer target Performance and function because various lower part system such as vehicles, signaling, power supply, rail track is consisted as complex. It is important first of all that describe correctly system requirement until configuration of system, design, manufacture, installation and test verification so that the complicated urban transit system is to act safety and reliable and to display target Performance and function properly. The system requirement assist the system developer to comprehensive the performance and function of system in basic design. Therefore, In this paper wishes to study way to analyze system of system requirement and apply to Urban transit.

  • PDF

A Feasibility Study on In-Vessel Core Debris Cooling through Lower Cavity Flooding

  • Yang, Soo-Hyung;Baek, Won-Pil;Chang, Soon-Heung
    • 한국원자력학회:학술대회논문집
    • /
    • 한국원자력학회 1996년도 추계학술발표회논문집(1)
    • /
    • pp.309-314
    • /
    • 1996
  • Feasibility study has been accomplished to evaluate the effectiveness of the in-vessel core debris cooling through lower cavity flooding using two dimensional finite difference scheme. The volume of cerium pool and decay power rate generated in corium pool were evaluated as important parameters to the temperature distribution on the reactor vessel lower head through previous works. In this study, the corium volume based on the System 80+ core structure and time dependent decay power rate are considered for feasibility evaluation. In addition, preliminary plans for the in-vessel core debris cooling through lower cavity flooding as severe accident management strategy, i.e. flooding timing, method and capacity, are suggested based on the result of the numerical study, international tendency related to in-vessel core debris cooling through lower cavity flooding.

  • PDF

보행 시 발생되는 하지근육의 힘의 변화에 대한 해석 (Analysis of Muscle Force Variation in the Lower Extremity during the Gait)

  • 김영은;전응식
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2000년도 춘계학술대회논문집A
    • /
    • pp.261-267
    • /
    • 2000
  • A mathematical model was developed to calculate the muscle force of lower extremity during the gait. We constructed a model of human locomotion, which includes a muscle-skeletal system with 7 segments and 16 lower limb muscles. Using a optimization technique, muscle forces variation of the lower extremity during the gait were generated and its result was verified by comparing a experimental results of EMG analysis. Moreover. the walking movement of the model could be compared quantitatively with those of experimental studies in human by inverse dynamics.

  • PDF

남성복(男性服)의 치수규격을 위한 하체부(下體部)의 체형분류(II) (Classification of Bodytype of Lower Part on Adult Male for the Apparel Sizing System)

  • 김구자
    • 한국의류학회지
    • /
    • 제17권4호
    • /
    • pp.602-607
    • /
    • 1993
  • Concept of the comfort and fitness becomes a major concern in the basic function of the ready-made clothes. This research was performed to classify and characterize Korean adult males anthropometrically. Sample size was 1290 subjects and their age range was from 19 to 54 years old. Sampling was carried out by the stratified sampling method. 75 variables in total were applied to classify the bodytypes. Data were analyzed by the multivariate method, especially factor and cluster analysis. The high factor loading items extracted by factor analysis were based to determine the variables of the cluster analysis for the similar bodytypes respectively. In the part of the lower body, 14 variables from the data were applied to classify the bodytypes of lower part by Ward's minimum variance method. The group fanning a cluster were subdivided into 5 sets by cross-tabulation extracted by the hierarchical cluster analysis. Type 3 and 4 in lower body were composed of the majority of 53.1% of the subjects. The Korean adult males had relatively well-balanced in lower body.

  • PDF

복합구조물의 하부층수 변화에 따른 비선형 동적응답특성 (Nonlinear Dynamic Response Characteristics with Variations in the Lower Stories of Mixed Building Structures)

  • 강병두;전대한;김재웅
    • 한국전산구조공학회:학술대회논문집
    • /
    • 한국전산구조공학회 2001년도 가을 학술발표회 논문집
    • /
    • pp.443-450
    • /
    • 2001
  • The Mixed building structures can be divided into three partition, namely, upper wall, lower frame, and transfer system which link two partitions. The purpose of this study is to investigate the nonlinear response characteristics of structures, as the stories of lower frame of mixed building structures changes. The recorded earthquake ground motions of EI Centro 1940 NS is adopted, and the maximum ground accelerations are adjusted to 55ga1, 110ga1, 220ga1, 330ga1. The conclusions of this study are the following. 1) The responses of model that the story of lower frame is one were different from those of other models. 2) The process of ductility hinge occurrence of member was ends of coupling beam of upper wall and ends of beam of lower frame in 55ga1, bases of shear wall on pit floor in 110ga1, and bases of column of 1F in 220ga1.

  • PDF

공동주택 구조형태별 층간 공기전달음 차단 성능 (The Performance of Insulation of Noise by Air between Floors According to Structure Systems of Apartment)

  • 이병권
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2007년도 춘계학술대회논문집
    • /
    • pp.1152-1155
    • /
    • 2007
  • Lately concerns about structure have been increased by advantages of floor impact noise, poilitical induction and changeability. Hence, Flat Plate Structure has been constructed increasingly. This study shows the comparison of the performance of sound insulation of Flat Plate Structure System and the existing Wall Structure. For this study, taking the same level organization of Daelim Architectural Environmental Research Center, I found the performance of sound insulation between the upper and lower floors about Wall Structure and Flat Plate Structure. Consequently, the performance of sound insulation between upper and lower floors of Flat Plate Structure was 3-5dB higher was approximately 3-5dB higher than one of Wall Structure. Especially, the performance of sound insulation on the upper floor was 1-3dB higher than on the lower floor. In addition, as the result of comparing radiation sound which radiates from the wall of lower floors with each structure system, Flat Plate Structure was about 4dB higher with Rw than Wall Structure. As we see totally, the performance of sound insulation of Flat Plate Structure is highter than one of the Wall Structure. It is 3-5dB higher and the main reason for this result depends on the existence of the wall which can radiate sound and nonexistence.

  • PDF

OPTIMAL SHAPE DESIGN OF THE FRONT WHEEL LOWER CONTROL ARM CONSIDERING DYNAMIC EFFECTS

  • Kang, B.J.;Sin, H.C.;Kim, J.H.
    • International Journal of Automotive Technology
    • /
    • 제8권3호
    • /
    • pp.309-317
    • /
    • 2007
  • In this study, we conducted a vibration fatigue analysis of the lower control arm in a vehicle suspension system. The vehicle was driven during the tests so that the dynamic effects could be taken into account. The dynamic load of the frequency domain was superimposed on the frequency response analysis. We performed a virtual proving ground test using multi-body dynamics, along with a finite element analysis and fatigue life predictions. Shape optimization was also considered using the design of the experimental approach, and a response surface analysis was performed to improve the durability performance of the lower control arm. We identified the elements that had the most influence on the optimal shape of the finite element model and analyzed the sensitivity of those elements. Then the optimal points that minimized the amount of damage to the areas of interest were determined through a response surface analysis. The results suggested that the fatigue life of the model increased as its mass was not increased excessively, and demonstrated that these design procedures yielded an appropriate optimized lower control arm model.

초고온 온도 측정을 위한 초음파 자왜 센서 시스템 개발 (Development of Ultrasonic Magnetostrictive Sensors System to Measure in Very High Temperatures)

  • 구길모;김상백;박치승;최종호;고덕영
    • 한국음향학회지
    • /
    • 제20권6호
    • /
    • pp.66-74
    • /
    • 2001
  • 본 논문에서는 노심 용융물과 원자로 용기하부 반구내벽 사이의 간격형성 여부 및 간극의 열적 영향을 측정하기 위한LAVA (Lower-plenum arrested vessel attack) 실험에서 초고온상태에 있는 노심 용융물의 온도를 측정할 목적으로 초고온 온도측정 시스템을 개발하였다. 본 연구에서는 제안된 이론의 유용성을 확인할 목적으로 개발한 초음파 자왜 센서 시스템을 이용하여 2300℃까지의 온도를 측정함으로써 실험을 통해 개발된 시스템의 효율성을 증명하였다.

  • PDF

족하수 환자에서의 보행기능 보조를 위한 표피 자극형 전기자극기 개발 (Development of surface electrode type electrical stimulator or supporting walk function in foot drop patients)

  • 임승관;정호춘;김규겸;진달복;박병림
    • 대한의용생체공학회:학술대회논문집
    • /
    • 대한의용생체공학회 1997년도 추계학술대회
    • /
    • pp.9-13
    • /
    • 1997
  • The present study was designed to develop the functional electrical stimulation system in order to restore motor function of paralytic patients. We attempt to establish adequate stimulus parameters for the recovery of work unction in lower limb paralysis patients and to develop the electrical stimulation system, which is effective to protect foot drop in these patients. In our animal and human experiment, adequate stimulus condition for surface electrode on the lower limb were 0.2-0.3ms at the duration and 50 Hz, which contain 600Hz train pulse. This parameter has efficiently prevented the foot drop from lower limb paralysis, decreased muscle fatigue and induced powerful contraction of lower limb muscle.

  • PDF

Mitigating the Urban Heat Island Phenomenon Using a Water-Retentive Artificial Turf System

  • Tebakari, Taichi;Maruyama, Tatsuya;Inui, Masahiro
    • 한국수자원학회:학술대회논문집
    • /
    • 한국수자원학회 2010년도 학술발표회
    • /
    • pp.91-100
    • /
    • 2010
  • To investigate the thermal properties of a water-retentive artificial turf system (W-ATS), we estimated hydrologic parameters including thermal conductivity, heat capacity, and surface albedo for both the W-ATS and natural grass. We used a model experiment to measure surface temperature and evaporation for both the W-ATS and natural grass. We found that the W-ATS had lower thermal conductivity than natural grass did, and it was difficult for the W-ATS to convey radiant heat to the ground. Compared to natural grass, the W-ATS also had lower heat capacity, which contributed to its larger variation in surface temperature: the W-ATS had higher surface temperatures during daytime and lower surface temperatures during nighttime. The albedo of the W-ATS was one-quarter that of natural grass, and reflected shortwave radiation from the W-ATS surface was lower than that from the surface of natural grass. These results indicate that the W-ATS caused the soil temperature to increase. Furthermore, evaporation from the W-ATS was one-quarter the value of evapotranspiration from natural grass.

  • PDF