• Title/Summary/Keyword: Low-voltage

Search Result 6,397, Processing Time 0.033 seconds

An Early Experience of Electroejaculation in Anejaculatory Men with Spinal Cord Injury (척수손상 환자에 대한 전기자극 인공사정의 초기 경험)

  • Kang, Il-Gyu;Cho, Myoung-Kwan;Oh, Chung-Hwan;Moon, Young-Tae;Kim, Sae-Chul;Choi, Jong-Han
    • Clinical and Experimental Reproductive Medicine
    • /
    • v.19 no.1
    • /
    • pp.87-94
    • /
    • 1992
  • From December 1991 to March 1992, 34 anejacuratory patients with spinal cord injury underwent 90 of electric stimulations with Seager NRH model 12. The average patient age was 43.5 years with a range of 23 to 48 years. The level of cord injury was cervical in 7, thoracic in 6, lumbar in 11, lumbosacral in 7 and conus medullaris in 3. The average number of electric stimulation per a patient was 2.65 with a range of 1 to 4. The average voltage and amplitude per a stimulation were 17.72 volts and 309. 89 mAmp with ranges of 5 to 25 volts and 50 to 500 mAmp. The total and motile sperm number were evaluated microscopically and analyzed statistically by paired t-test according to the frequency of electroejaculation, level of cord injury and voiding pattern. The results were obtained as follows. 1. An overall success rate of electroejaculation was 85.3% among 34 patients and 82.2% among 90 electric stimulations. 2. The total and motile sperm number per a stimulation were not correlated the frequency of electric stimulation, level of cord injury and voiding pattern. 3. Complications occured in 10 cases; severe low abdominal pain in 5, hypertension in 2, sweating in 1, headache in 1 and neck stiffness in 1. All the copmlications subsided spontaneously within 5 to 10 minutes after transient interruption of the electric stimulation. In summary, rectal probe electroejaculation is an accepted safe means of procuring sperm from spinal cord injury patients with ejaculatory incompetence. However very poor sperm motility was found and it was not related with the frequency of electroejaculation, level of cord injury and voiding pattern. Further investigation would be needed to conclude and to identify the reasons for impaired sperm motility.

  • PDF

Characteristics and Fabrication of Complementary Electrochromic Device ( I ) (상보형 일렉트로크로믹 소자의 제조 및 특성 ( I ))

  • Lee, S.Y.;Seo, D.K.;Kim, Y.H.;Cho, T.Y.;Chun, H.G.
    • Journal of Sensor Science and Technology
    • /
    • v.6 no.1
    • /
    • pp.24-34
    • /
    • 1997
  • In this study, two different types of complementary electrochromic devices using amorphous $WO_{3}$ films as a working electrode, $V_{2}O_{5}$ film and NiO film as counter electrodes respectively were investigated. For the devices using amorphous and crystalline $V_{2}O_{5}$ films of $100{\sim}150nm$ thickness with $ITO/WO_{3}/LiClO_{4}-PC/V_{2}O_{5}/ITO$ structure, an optical modulation of $50{\sim}60%$ were obtained at a potential range of $1{\sim}2V$. It has been shown that transmittance and reflectance of light could be electrically controlled by low applied voltage. For the devices with $ITO/WO_{3}/LiClO_{4}-PC/NiO/ITO$ structure in which NiO film was deposited by a RF reactive sputtering, the optical modulation in visible light region (${\lambda}=550nm$) and in near infrared light region (${\lambda}=850nm$) were 25% and 30%, respectively.

  • PDF

Design and Fabrication of on Oscillator with Low Phase Noise Characteristic using a Phase Locked Loop (위상고정루프를 이용한 낮은 위상 잡음 특성을 갖는 발진기 설계 및 제작)

  • Park, Chang-Hyun;Kim, Jang-Gu;Choi, Byung-Ha
    • Journal of Navigation and Port Research
    • /
    • v.30 no.10 s.116
    • /
    • pp.847-853
    • /
    • 2006
  • In this paper, we designed VCO(voltage controlled oscillator} that is composed of a dielectric resonator and a varactor diode, and the PLDRO(phase locked dielectric resonator oscillator) that is combined with the sampling phase detector and loop filter. The results at 12.05 GHz show the output power is 13.54 dBm frequency tuning range approximately +/- 7.5 MHz, and power variation over the tuning range less than 0.2 dB, respectively. The phase noise which effects on bits error rate in digital communication is obtained with -114.5 dBc/Hz at 100 kHz offset from carrier, and The second harmonic suppression is less than -41.49 dBc. These measured results are found to be more improved than those of VCO without adopting PLL, and the phase noise and power variation performance characteristics show the better performances than those of conventional PLL.

A Design of Fire-Command Synchronous Satellite Pyrotechnic Circuit (점화 명령에 동조된 인공위성 파이로테크닉 회로 설계)

  • Koo, Ja Chun;Ra, Sung Woong
    • Journal of Korea Society of Industrial Information Systems
    • /
    • v.18 no.5
    • /
    • pp.81-92
    • /
    • 2013
  • The satellite includes many release mechanisms such as solar array deployment, antenna deployment, cover to protect contamination in scientific equipment, pyro value of the propulsion subsytem, and bypass device in Li-Ion cell module. A drive the initiators is a critical to the successful mission because the initiators of release mechanism driving by the pyrotechnic circuit is operated in single short. The pyrotechnic circuit has to provide switching network for safety. A typical switching network has defect consisting of high current rating fire switch to handle switching transient current during fire the initiator. The pyrotechnic circuit is required some form of power conditioning to reduce the peak power demanded from the bus if the initiators are to be fired from the main bus. This paper design a pyrotechnic circuit synchronized to the fire-command to activate the fire switch to overcome use high current rating fire switch to handle switching transient current during fire the initiator. The pyrotechnic circuit provides a current limited widow pulse for fire current synchronized to the fire-command to insure that fire switch will only carry the current but never switch it. The current limited widow pulse for fire current can be possible to use low current rating and light mass switch in switching network. The current limit function in the pyrotechnic circuit reduces supply voltage to initiator and provides the effect of power conditioning function to reduce peak bus power. The pyrotechnic circuit to apply satellite development on geostationary orbit is verified the function by test in development model.

Evaluation of the Stability of Oxidation-Reduced Potential (ORP) Using the Filter of the Alkaline Water (알칼리 환원수 필터의 산화환원전위 안정화 평가)

  • Nam, Sangyep;Kwon, Yunjung
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.53 no.8
    • /
    • pp.129-135
    • /
    • 2016
  • This study is about ionic water generator filter Recently, a lot of people feel deep interest in health and drinking water. Evaluation of the stability of oxidation-reduced potential (ORP) using the filter of the alkaline water. This study utilizes the three filter of activated carbon, UF, carbon block in alkaline reduced water equipment. Passing the water to the filter is evaluated that the OPR values are stability in accordance with the change of the volume in the bucket. Alkaline reduced water equipment is a system that has the function of making the water reduction. This system is the values of the human body beneficial minerals and ORP are made in the functional water has a very low value than general water. Which has passed through the filter the water in the water negative ions and positive ions through the electrolytic. After electrolysis, the cathode side by water, including $Ca^+$, $K^+$, $Mg^+$, $Na^+$ water gets Alkaline Reduced Water containing the minerals beneficial to the human body. A positive electrode side is made of the organic materials that have an anion such as chlorine (Cl), phosphorus (P), sulfur(S). This experiment uses the Alkaline Reduced Water to adjust the magnitude of the voltage of the electrolysis in the Alkaline Reduced Water. That is 1st step(pH8) 2nd step (pH8.5) 3th step (pH9), 4th step (pH9.5) in the Alkaline Reduced Water and -1st step (pH6.0), -2nd step (pH5.0) used as the acidic oxidation water. When the water passes through the three filter in this system was evaluated whether the ORP values are changed and stabilized. When about 100 liters of water passing through the filter was confirmed that the ORP values are stability and evaluation.

Low Phase Noise VCO Using Novel Harmonic Control Circuit Based on Composite Right/Left-Handed Transmission Line (혼합 우좌향 전송 선로 기반의 새로운 고조파 조절 회로를 이용한 저위상 잡음 전압 제어 발진기)

  • Choi, Jae-Won;Seo, Chul-Hun
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.47 no.1
    • /
    • pp.84-90
    • /
    • 2010
  • In this paper, a novel voltage-controlled oscillator (VCO) using the harmonic control circuit based on the composite right/left-handed (CRLH) transmission lines (TLs) is presented to reduce the phase noise without the reduction of the frequency tuning range and miniaturize the circuit size. The phase noise is reduced by the novel harmonic control circuit having the short impedances for the second- and third-harmonic components. The proposed harmonic control circuit is designed by using the CRLH TLs with the dual-band characteristic by the frequency offset and phase slope of the CRLH TLs. The high-Q resonator has been used to reduce the phase noise, but has the problem of the frequency tuning range reduction. However, the frequency tuning range of the proposed VCO has not been reduced because the phase noise has been reduced without the high-Q resonator. The miniaturization of the circuit size is achieved by using the CRLH TLs instead of the conventional right-handed (RH) TLs. The phase noise of VCO is -119.17 ~ -117.50 dBc/Hz at 100 kHz in the tuning range of 5.731 ~ 5.938 GHz.

Low Phase Noise VCO using Microstrip Square Open Loop Multiple Split Ring Resonator (마이크로스트립 사각 개방 루프 다중 SRR(Split Ring Resonator)를 이용한 저위상 잡음 전압 제어 발진기)

  • Choi, Jae-Won;Seo, Chul-Hun
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.44 no.11
    • /
    • pp.60-66
    • /
    • 2007
  • In this paper, a novel voltage-controlled oscillator (VCO) using the microstrip square open loop multiple split ring resonator (OLMSRR) is presented for reducing the phase noise property. The square-shaped multiple split ring resonator (MSRR) having the form of the microstrip square open loop is investigated to realize this property. Compared with the microstrip square open loop resonator and the microstrip square open loop split ring resonator (OLSRR) as well as the conventional microstrip line resonator, the microstrip square OLMSRR has the larger coupling coefficient value, which makes a higher Q value, and has reduced the phase noise of VCO. The VCO with 1.7V power suppIy has the phase noise of $-124.5\;{\sim}\;-122.0\;dBc/Hz$ @ 100 kHz in the tuning range, $5.746\;{\sim}\;5.84\;GHz$. The figure of merit (FOM) of this VCO is $-203.96\;{\sim}\;-201.6\;dBc/Hz$ @ 100 kHz in the same tuning range. Compared with VCO using the conventional microstrip line resonator, VCO using the microstrip square open loop resonator and VCO using microstrip square OLSRR, the phase noise property of VCO using the proposed resonator has been improved in 25.66 dB, 8.34 dB, and 4.5 dB, respectively.

A Design of Power Management IC for CCD Image Sensor (CCD 이미지 센서용 Power Management IC 설계)

  • Koo, Yong-Seo;Lee, Kang-Yoon;Ha, Jae-Hwan;Yang, Yil-Suk
    • Journal of IKEEE
    • /
    • v.13 no.4
    • /
    • pp.63-68
    • /
    • 2009
  • The power management integrated circuit(PMIC) for CCD image sensor is presented in this study. A CCD image sensor is very sensitive against temperature. The temperature, that is heat, is generally generated by the PMIC with low efficiency. Since the generated heat influences performance of CCD image sensor, it should be minimized by using a PMIC which has a high efficiency. In order to develop the PMIC with high efficiency, the input stage is designed with synchronous type step down DC-DC converter. The operating range of the converter is from 5V to 15V and the converter is controlled using PWM method. The PWM control circuit consists of a saw-tooth generator, a band-gap reference circuit, an error amplifier and a comparator circuit. The saw-tooth generator is designed with 1.2MHz oscillation frequency. The comparator is designed with the two stages OP Amp. And the error amplifier has 40dB DC gain and $77^{\circ}$ phase margin. The output of the step down converter is connected to input stage of the charge pump. The output of the charge pump is connected to input of the LDO which is the output stage of the PMIC. Finally, the PMIC, based on the PWM control circuit and the charge pump and the LDO, has output voltage of 15V, -7.5V, 3.3V and 5V. The PMIC is designed with a 0.35um process.

  • PDF

A Study on the Characteristics Assessment and Fabrication of Distribution Board according to KEMC Standards (KEMC 규정에 의한 분전반의 제작 및 특성 평가에 관한 연구)

  • Lee, Byung-Seol;Choi, Chung-Seog
    • Fire Science and Engineering
    • /
    • v.31 no.3
    • /
    • pp.63-72
    • /
    • 2017
  • This study fabricated a low-voltage 10 circuit distribution board based on the KEMC (Korea Electrical Manufacturers Cooperative) 2102-610 standard and performed a characteristics assessment of the developed 10 circuit distribution board to secure product stability. The developed 10 circuit distribution board is designed to have the characteristics of insulation materials, as well as resistance to corrosion ultraviolet radiation and mechanical impact. The developed distribution board is fabricated to have an appropriate protection class of enclosure, electric shock prevention and protection circuits, switchgear and its components, internal electrical circuits and connectors, external conduct terminal, insulation characteristics, temperature rise test, heat resistance, etc. The developed 10 circuit distribution board consists of a single phase circuit and 3-phase circuits. It is possible to measure in real time the leakage current generated from the load distribution line by installing a sensor module at the load side of each of the branched switchgears. In addition, it is possible to increase a circuit according to the use and purpose of the load and to also manage and check the load in real time. Temperature rise tests were performed on the developed 10 circuit distribution board at 18 places including the inlet connection, main circuit and distribution circuit bus bars and bus bar supports, etc. The highest temperature of $65.3^{\circ}C$ was measured at the R-Phase of the connection of the MCCB power supply for the branch circuit bus bar and a temperature rise of $61.6^{\circ}C$ was measured at the T-Phase of the load side. When applying thermal stress to an MCCB for 6 hours at $180^{\circ}C$ using a heat resistant experimental device, it was found that the actuator lever was transformed and moved in the tripped state.

A Study on Poisoning of the Reforming Catalysts on the Position of Anode in the Direct Internal Reforming Molten Carbonate Fuel Cell (직접 내부개질형 용융탄산염 연료전지의 음극판 위치에 따른 개질 촉매 피독에 관한 연구)

  • Wee, Jung Ho;Chun, Hai Soo
    • Applied Chemistry for Engineering
    • /
    • v.10 no.5
    • /
    • pp.652-659
    • /
    • 1999
  • The trend of poisoning of reforming catalyst along with the position of anodic catalyst bed was studied. Keeping the conditions that steam to carbon ratio was 2.5, operating voltage was 0.75 V, current density was $140mA/cm^2$, the unit cell was operated during 24 hrs at a steady state. And then the cell was stopped, the catalysts packed in the position of inlet, middle and outlet were sampled individually and then the amount of carbon, Li and K poisoned were analysed. After 100 hrs operated, the catalysts at the same positions were analysed at the same manner. The result of this experiment was as followings. After 24 hrs operated, the poisoning amounts of Li and K in the catalyst were 0.27 wt% at inlet, 0.23 wt% at middle and the highest value 1.59 wt% at outlet. After 100 hrs, the amount of poisoning is the highest in the catalyst packed at the inlet of unit cell. The performance simulation of unit cell explained these trends of poisoning catalysts. The simulation told that the catalyst in the region of the inlet of unit cell treated the 90% of initial methane flow rate and the highest electrochemical reaction happened in this region. So the catalysts of this region were the most poisoned with carbon, Li and K and also the rate of poisoning is faster than that of the catalyst at other regions. The temperature at the region of outlet of unit cell was $30^{\circ}C$ higher than that of other regions, so more Li, and K vaporized than at other regions and little reforming reaction at this region made the catalysts poisoning rate low.

  • PDF