• 제목/요약/키워드: Low-temperature Heat Source

검색결과 280건 처리시간 0.029초

유기랭킨사이클에서 핀치온도차의 변화에 따른 열교환기의 열역학적 성능특성 (Characteristics of Thermodynamic Performance of Heat Exchanger in Organic Rankine Cycle Depending on Pinch Temperature Difference)

  • 김경훈;정영관;박상희
    • 한국수소및신에너지학회논문집
    • /
    • 제26권6호
    • /
    • pp.590-599
    • /
    • 2015
  • In this paper a performance analysis is carried out based on the first and second laws of thermodynamics for heat exchanger in organic Rankine cycle (ORC) for the recovery of low-temperature finite thermal energy source. In the analysis, effects of the selection of working fluid and pinch temperature difference are investigated on the performance of the heat exchanger including the effectiveness of the heat exchanger, exergy destruction, second-law efficiency, number of transfer unit (NTU), and pinch point. The temperature distribution are shown depending on the working fluids and the pinch temperature difference. The results show that the performance of the heat exchanger depends on the pinch temperature difference sensitively. As the pinch temperature increases, the exergy destruction in the evaporator increases but the effectiveness, second law efficiency and NTU decreases.

암모니아-물 랭킨사이클의 증발기에서의 엑서지 및 엔트랜시 성능 특성 해석 (Performance Characteristics Analysis of Evaporator in Ammonia-Water Rankine Cycle Based on Exergy and Entransy)

  • 김경훈;정영관
    • 한국수소및신에너지학회논문집
    • /
    • 제30권6호
    • /
    • pp.621-628
    • /
    • 2019
  • The use of the ammonia-water zeotropic mixture as a working fluid in the power generating system has been considered as a proven technology for efficient recovery of low-grade heat sources. This paper presents a thermodynamic performance analysis for ammonia-water evaporator using low-grade heat source, based on the exergy and entransy which has been recently introduced as a physical quantity to describe the heat transfer ability of an object. In the analysis, effects of the ammonia mass fraction and source temperature of the binary mixture are investigated on the system performance such as heat transfer, effectiveness, exergy destruction, entransy dissipation, and entransy dissipation based thermal resistance. The results show that the ammonia mass concentration and the source temperature have significant effects on the thermodynamic system performance of the ammonia-water evaporator.

액분사 사이클을 이용한 공기 열원 열펌프의 사이클 시뮬레이션 (Cycle Simulation of an Air Source Heat Pump Using Liquid Injection)

  • 김욱중;홍용주;남임우;강원일;공용상
    • 설비공학논문집
    • /
    • 제12권3호
    • /
    • pp.244-250
    • /
    • 2000
  • An air source heat pump using liquid injection technique, which can be applied for very low temperature climate, has been simulated to examine the design options. Comparison between the simulation and experiment has been carried out to validate the simulation method. Effects of various design parameters such as liquid injection rate and injection pressure are Investigated to optimize the performance of the heat pump. Finally, optimal liquid infection rate and injection pressure to maintain sufficient heating capacity and moderate discharge refrigerant temperature are suggested when the heat pump was operated at very low outdoor temperature.

  • PDF

에탄올을 첨가한 TMA 포접화합물의 냉각특성에 대한 연구 (The Study on Cooling Characterics of TMA Clathrate with Ethanol)

  • 김창오;김진흥;정낙규;김석현
    • 설비공학논문집
    • /
    • 제14권8호
    • /
    • pp.634-640
    • /
    • 2002
  • The purpose of this study is to investigate the propriety of TMA clathrate as a cold storage medium. Particularly, this is to examine the extent of subcooling improvement when the additives is added to the TMA clathrate, because water used for cold storage ma terial has low phase change temperature and subcooling. This study has been analyzed and compared pure water with TMA 30 wt% clathrate how phase change temperature, subcooling and specific heat in the various concentrations are changed. This results prove low phase change temperature and subcooling control effect when the ethanol is added to the TMA 30 wt% clathrate than the TMA 30 wt% clathrate. In addition, it results low specific heat when there is added to the TMA 30 wt% clathrate over 0.5 wt% ethanol in the cold heat source temperature under $-7^{\circ}C$. The other side, it results high specific heat when the ethanol is added in it at the cold heat source temperature under $-5^{\circ}C$. Therefore, it is found that the additive must be controlled by available solution limit and study for new additive must be lasted to know its effect.

LNG 냉열을 열싱크로 이용하는 유기랭킨사이클(ORC)의 작동유체에 따른 성능 특성 (Effects of Working Fluids on the Performance Characteristics of Organic Rankine Cycle (ORC) Using LNG Cold Energy as Heat Sink)

  • 김경훈;하종만;김경천
    • 한국수소및신에너지학회논문집
    • /
    • 제25권2호
    • /
    • pp.200-208
    • /
    • 2014
  • This paper presents thermodynamic performance analysis of organic Rankine cycle (ORC) using low temperature heat source in the form of sensible energy and using liquefied natural gas (LNG) as heat sink to recover the cryogenic energy of LNG. LNG is able to condense the working fluid at a very low condensing temperature in a heat exchanger, which leads to an increased power output. Based on the mathematical model, a parametric analysis is conducted to examine the effects of eight different working fluids, the turbine inlet pressure and the condensation temperature on the system performance. The results indicate that the thermodynamic performance of ORC such as net work production or thermal efficiency can be significantly improved by the LNG cold energy.

저온측과 고온측 냉매간 열교환이 열펌프의 성능특성에 미치는 영향 (Effect of the Heat Exchange between Low and High Temperature Refrigerant on the Heat Pump Performance)

  • 이건중;송현갑
    • Journal of Biosystems Engineering
    • /
    • 제24권4호
    • /
    • pp.343-350
    • /
    • 1999
  • The ambient air is commonly used as low-temperature heat source for heat pump operation. However, the coefficient of performance(COP) of the air to water heat pump is decreased with the ambient air temperature drop. In this study to solve this problem, the AVACTHE(Automatic Variable Area Capillary Type Heat Exchanger) with 3 levels of heat exchange area(0, 1,495.4, 1,794.5$\textrm{cm}^2$)was installed in the refrigerant circuit of the heat pump. The AVACTHE effect on the performance of heat pump was tested with the ambient air temperature variation. The COP improvement of the heat pump could be achieved by the AVACTHE installation when below -5$^{\circ}C$ of the ambient air temperature.

  • PDF

열원온도와 작동유체에 따른 초월임계 유기랭킨사이클의 열역학적 성능 특성 (Thermodynamic Performance Characteristics of Transcritical Organic Rankine Cycle Depending on Source Temperature and Working Fluid)

  • 김경훈
    • 대한기계학회논문집B
    • /
    • 제41권11호
    • /
    • pp.699-707
    • /
    • 2017
  • 본 연구에서는 아홉 종류의 작동유체를 고려하여 저온 열원으로 구동되는 아임계 및 초월임계 유기 랭킨 사이클의 열역학적 성능 특성을 비교 해석한다. 터빈입구압력, 열원온도 및 작동유체가 열교환기 내 온도분포와 핀치포인트, 작동유체의 유량, 시스템 출력 및 열효율 등 시스템의 성능에 미치는 영향을 분석한다. 해석 결과는 작동유체의 압력이 아임계 영역에서 초임계 영역으로 높아지면 열교환기에서 열원과 작동유체 사이의 온도 불균일 정도가 감소하면서 시스템 출력이나 열효율 등은 증가하나 시스템의 단위출력당 터빈 크기는 작아짐을 보여준다.

숙박업소 건물의 히트펌프 냉난방 시스템 적용을 위한 시뮬레이션 연구 (Study on the Simulation of Heat Pump Heating and Cooling Systems to Resident Building)

  • 최영돈;한성호;조성환;김두성;엄철준
    • 설비공학논문집
    • /
    • 제20권1호
    • /
    • pp.65-74
    • /
    • 2008
  • In Korea, air source heat pump system is less efficient than conventional heat source facilities, such as ground source, river water, because the air temperature in winter season is so low that COP of air source heat pump system drops below 3.0. Therefore, the study on the application of heat pump heating and cooling systems is crucial for the efficient popularization of heat pump. In this work, we present the dynamic analysis of energy consumption for the large resident building by heat resistance-capacitance method. The system simulation of water storage air source heat pump is additionally performed by changing of sizes and locations of the hospital building. The computed results show that energy cost of water storage air source heat pump is low, so it is more economical than absorption chiller & heater.

디스크의 전기열치료시 수술변수에 관한 연구 (An Investigation on Surgical Parameters for the Treatment of Intervertebral Disc during Electrothermal Therapy)

  • 진의덕;최진승;탁계래;이봉수;이법이
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2006년도 춘계학술대회 논문집
    • /
    • pp.513-514
    • /
    • 2006
  • Recently intradiscal electrothermal therapy is introduced, which is a new and minimally invasive technique fer the treatment of discogenic low back pain. This procedure involves the percutaneous threading of a flexible catheter into the disc under fluoroscopic guidance. The catheter, composed of thermal resistive coil, heats the posterior annulus of the disc, causing contraction of collagen fibers and destruction of afferent nociceptors. This study tries to investigate the effects of the important factors of this procedure such as heat source temperature and heat applying time on the temperature distribution within the intervertebral disc. This study utilized both computer simulation and the experiment for the verification of finite element analysis. FE analysis was carried out with ANSYS v7.0 (ANSYS Inc, USA) using 10,980 number of brick element and 12,551 number of node. The functional spinal units of 5 month old swine were used for the experiment and the temperature was monitored using 10 channel temperature measurement device MV200. Through this study, it was able to analyze the temperature range of inner intervertebral disc by two mechanisms which are known to alleviate pain clinically. The results showed that when the heat source temperature was kept up 80 degree for 1,020 seconds, the temperature of inner annulus reached at 45 degree up to the distance of 15.6mm from heat source, which explains coagulation of inner annulus by heat. When the same heat source was used, the temperature of inner nucleus reached at 60 degree up to the distance of 9mm from heat source, which explains contraction of inner nucleus by heat.

  • PDF

LNG 냉열을 이용하는 암모니아-물 복합 재생 동력 사이클의 성능 특성 (Performance Characteristics of a Combined Regenerative Ammonia-Water Based Power Generation Cycle Using LNG Cold Energy)

  • 김경훈;오재형;정영관
    • 한국수소및신에너지학회논문집
    • /
    • 제24권6호
    • /
    • pp.510-517
    • /
    • 2013
  • The ammonia-water based power generation cycle utilizing liquefied natural gas (LNG) as its heat sink has attracted much attention, since the ammonia-water cycle has many thermodynamic advantages in conversion of low-grade heat source in the form of sensible energy and LNG has a great cold energy. In this paper, we carry out thermodynamic performance analysis of a combined power generation cycle which is consisted of an ammonia-water regenerative Rankine cycle and LNG power generation cycle. LNG is able to condense the ammonia-water mixture at a very low condensing temperature in a heat exchanger, which leads to an increased power output. Based on the thermodynamic models, the effects of the key parameters such as source temperature, ammonia concentration and turbine inlet pressure on the characteristics of system are throughly investigated. The results show that the thermodynamic performance of the ammonia-water power generation cycle can be improved by the LNG cold energy and there exist an optimum ammonia concentration to reach the maximum system net work production.