• Title/Summary/Keyword: Low-temperature

Search Result 17,556, Processing Time 0.045 seconds

Novel deposition technology for nano-crystalline silicon thin film at low temperature by hyper-thermal neutral beam assisted CVD system

  • Jang, Jin-Nyoung;Song, Byoung-Chul;Oh, Kyoung-Suk;Yoo, Suk-Jae;Lee, Bon-Ju;Choi, Soung-Woong;Park, Young-Chun;Hong, Mun-Pyo
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2009.10a
    • /
    • pp.1025-1027
    • /
    • 2009
  • Novel low temperature deposition process for nano-crystalline Si thin film is developed with the hyper-thermal neutral beam (HNB) technology. By our HNB assisted CVD system, the reactive particles can induce crystalline phase in Si thin films and effectively combine with heating effect on substrate. At low deposition temperature under $80^{\circ}C$, the HNB with proper incident energy controlled by the reflector bias can effectively enhance the nano-crystalline formation in Si thin film without any additional process. The electrical properties of Si thin films can be varied from a-Si to nc-Si according to change of HNB energy and substrate temperature. Characterization of these thin films with conductivity reveal that crystalline of Si thin film can increase by assist of HNB with appropriate energy during low temperature deposition. And low temperature prcoessed nc-Si TFT performance has on-off ratio as order 5.

  • PDF

Analysis of O-J-I-P Transients from Four Subtropical Plant Species for Screening of Stress Indicators under Low Temperature (저온스트레스 지표 선발을 위한 아열대성 식물 4종의 O-J-I-P곡선 분석)

  • Oh Soonja;Koh Seok Chan
    • Journal of Environmental Science International
    • /
    • v.14 no.4
    • /
    • pp.389-395
    • /
    • 2005
  • The changes of O-J-I-P transients were investigated using leaves of four subtropical plant species (Crinum asiaticum var. japonicum, Osmanthus insularis, Chloranthus glaber and Asplenium antiquum) under the natural conditions in winter, in order to select the stress indicators for diagnosing physiological states of plants under low temperature. In the O-J-I-P transients of these species, the fluorescence intensity was found to be higher in O-step and lower in P-step in winter than in summer. Particularly, the fluorescence intensity of the P-step in Crinum asiaticum var. japonicum was lower than those of other three plant species, indicating that Crinum asiaticum var. japonicum is the most sensitive to low temperature. Of the chlorophyll fluorescence parameters derived from O-J-I-P transients of four subtropical plants, Fm, Fv/Fo, ABS/CS, TRo/CS, $\phi_{po}$ and $\phi_{po}/(1-\phi_{po})$ decreased significantly with the increase of Fo, Sm, N, EToICS, ETo/RC and $\psi_o/(1-\psi_o)$ depending on temperature drop in winter. Therefore, these parameters could be used as indicators for estimating low temperature stress and diagnosing physiological states of plants under the natural conditions in winter.

Study on the Vinyl House Heating by Warm Air (농업용 비닐하우스의 온풍난방에 관한 기초적 연구)

  • 조진구;이근후
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.19 no.3
    • /
    • pp.4483-4491
    • /
    • 1977
  • The results obtained are as follows; 1. The variation of the temperature in a vinyl house without heating system is similar to that of air temperature in a day. The difference of maximum temperature and minimum one in a day is 27$^{\circ}C$ which is two times greater than the daily difference of air temperature. 2. When the length of the duct is increased, the high temperature zone is built up in the direction of warm air discharge from the duct, and the low temperature zone is built up in the opposite direction of warm air discharge. But, in case of the duct length is short (0.05 L), the temperature distrubution in a vinyl house become uniform. It is concluded that the shorter length of the duct, the better the distribution of the temperature in a vinyl house is. 3. When the duct is installed at high position, the high temperature zone is built up in the upper zone of the vinyl house and the low temperature zone is built up in the lower zone. And when the position of the duct is low, the rate of temperature variation along the vertical direction become high, and the direct contact of warm air with the plant in the house is occured. It is concluded that the duct should be installed at the position of slightly higher than the plant height. 4. When the fuel consumption rate is fixed at the 101/hr, the lowest temperature warming rate in the vinyl house is 5$^{\circ}C$ without regard to the air temperature.

  • PDF

Analyzing Impact of the Effect of Greenbelts on the Land Surface Temperature in Seoul Metropolitan Area (수도권 그린벨트가 지표면 온도에 미치는 영향 분석)

  • Kim, Hee-Jae
    • Journal of Urban Science
    • /
    • v.9 no.1
    • /
    • pp.17-31
    • /
    • 2020
  • This study aims to analyze the relations among greenbelt, urban land surface temperature empirically in order to assess the environmental effects of the greenbelt in the Seoul metropolitan area, objectively. For this purpose, this study conducts an empirical analysis of impacts of greenbelt on urban land surface temperature using a multiple-regression model. The main data employed in the analysis include real-time air pollution data, Landsat 8-OLI Landsat imagery data, KLIS data and Jip-gye-gu data. The major findings are summarized as follows. NDVI has a negative (-) correlation with the land surface temperature, and the urban temperature is high in areas with poor vegetation. The land surface temperature is low in residential or commercial areas, while the temperature is high in industrial areas. The temperature is low in green fields, open spaces, and river areas. it is found that the urban land surface temperature is low in the greenbelt zone. In the greenbelt zone, there is an effect that reduces the land surface temperature by 1% on average, as compared to that at the center of the Seoul metropolitan area. Especially, the center of the Seoul metropolitan area, in a range from 0.6% to 1.9% of the average temperature, the temperature gets lower up to approximately 3km from the greenbelt boundary.

A Basic Study on Burr Formation of Micro Cutting Process with the Ferrous Metal at tow Temperature (철계 금속 마이크로 절삭 가공시 저온 환경에서의 버 발생에 관한 기초연구)

  • Kim, G.H.;Kim, D.J.;Sohn, J.I.;Yoon, G.S.;Heo, Y.M.;Cho, M.W.
    • Transactions of Materials Processing
    • /
    • v.18 no.2
    • /
    • pp.166-171
    • /
    • 2009
  • In this paper, a basic study on micro cutting process with SM20C at low temperature environment was performed. In macro cutting fields, the cryogenic cutting process has been applied to cut the refractory metal but, the serious problem may be generated in micro cutting fields by the cryogenic environment. However, if the proper low temperature is applied to micro cutting area, the cooling effect of cutting heat is expected. Such effect can make the reduction of tool wear and burr formation. For verifying this possibility, the micro cutting experiment at low temperature was performed and SEM images were analyzed.

Electrical Characteristics of Piezoelectric Transformer using Low Temperature Sintering PCW-PMN-PZT Ceramics (저온소결 PCW-PMN-PZT 세라믹스를 적용한 압전변압기의 전기적 특성)

  • Chung, Kwang-Hyun;Yoo, Ju-Hyun
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.19 no.4
    • /
    • pp.350-356
    • /
    • 2006
  • In this study, piezoelectric transformer was manufactured at the sintering temperature of $950^{\circ}C$, and then the feasibility of application to low temperature sintering piezoelectric transformers was investigated by evaluating the electrical characteristics of it. The voltage ratio of piezoelectric transformer showed the maximum value at the resonant frequency of input part, and increased according to the increase of load resistance. The output power and efficiency of piezoelectric transformer showed the superior properties when the output impedance of it coincides with the load resistance. Piezoelectric transformer manufactured at the low temperature of $950^{\circ}C$ showed the heat generation less than $20^{\circ}C$ at the output power of 30 W, and stable driving characteristics.

Self-Cleaning and Photocatalytic Performance of TiO2 Coating Films Prepared by Peroxo Titanic Acid

  • Yadav, Hemraj M.;Kim, Jung-Sik
    • Korean Journal of Materials Research
    • /
    • v.27 no.11
    • /
    • pp.577-582
    • /
    • 2017
  • Self-cleaning and photocatalytic $TiO_2$ thin films were prepared by a facile sol-gel method followed by spin coating using peroxo titanic acid as a precursor. The as-prepared thin films were heated at low temperature($110^{\circ}C$) and high temperature ($400^{\circ}C$). Thin films were characterized by X-ray diffraction(XRD), Field-emission scanning electron microscopy(FESEM), UV-Visible spectroscopy and water contact angle measurement. XRD analysis confirms the low crystallinity of thin films prepared at low temperature, while crystalline anatase phase was found the for high temperature thin film. The photocatalytic activity of thin films was studied by the photocatalytic degradation of methylene blue dye solution. Self-cleaning and photocatalytic performance of both low and high temperature thin films were compared.

A Study on the Strengths of Polyurethane Morthar Cured under Low Temperature Condition (저온양생한 폴리우레탄 모르타르의 강도특성에 관한 연구)

  • 오종석;정효석;박홍신;조영국;소양섭
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1999.04a
    • /
    • pp.337-342
    • /
    • 1999
  • The Purpose of this study is to evaluate the strength characteristics of polyurethane(PUR) mortar cured under low temperature condition. PUR mortars are prepared with various catalyst content, methylene chloride(MC) content as a viscosity reducing agent, and curing age at low temperature condition of $0^{\circ}C$, -5$^{\circ}C$ and -1$0^{\circ}C$, tested for working life, compressive and flexural strengths. From the test results, the catalyst and MC contents affect the degree of hardening and blowing of PUR mortar. Strengths increase with an increasing catalyst content at low temperature. Flexural and compressive strength of PUR mortar are about 177kgf/$\textrm{cm}^2$ and 490kgf/$\textrm{cm}^2$ respectively at curing temperature of -1$0^{\circ}C$ with catalyst content of 0.4%. Therefore, it is apparent that this PUR mortars have a sufficient strengths for repair of concrete structures.

  • PDF

On Cutting Characteristics Change of Low Temperature Cooling Tool(1st Report) - Cutting Characteristics of Cage Motor Rotor - (저온냉각공구의 절삭특성 변화 (제1보) -모터 회전자의 절삭특성)

  • 김순채;김희남
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1994.10a
    • /
    • pp.44-48
    • /
    • 1994
  • The cutting process of cage motor rotor require high precision and good roughness. The surface roughness of cutting face is very important factor with effect on the magnetic flux density of cage motor rotor. The paper describes a cause of decrease in the cutting force and roughness on low temperature cooling tool by means of analysis on the mechanism of force system at cutting confition and experimental findings. The main results as compared with the room temperature cutting are as follow : 1) The cutting resistance decreased due to low temperature cooling tool. 2) The surface roughness decreased due to low temperature cooling tool.

  • PDF

A study on the Tailoring of Environmental Requirements for XKT-1T Aircraft (XKT-1T 항공기 환경 요구사항 적합화 연구)

  • Kim, Jin Seog
    • Journal of the Korean Society of Systems Engineering
    • /
    • v.17 no.1
    • /
    • pp.97-106
    • /
    • 2021
  • The purpose of the study on the tailoring of environmental requirements for KT-1 Export Version(XKT-1T) aircraft is not only based on meeting the compliance of the environmental reliability, customer satisfaction, but also for the expansion of its export. This paper proposes the environmental requirements tailoring processes and High/Low temperature conditions, test procedures, and the results of test profiles for the aircraft. Amongst many existing environmental requirements, the temperature requirements are considered as the most basic and the most important environmental requirements. The High/Low temperature tests are considered and tailored to the high and low temperature methods of MIL-STD-810.