Current Harmonics Rejection and Improvement of Inverter-Side Current Control for the LCL Filters in Grid-Connected Applications

  • Xu, Jinming;Xie, Shaojun;Zhang, Binfeng
    • Journal of Power Electronics
    • /
    • v.17 no.6
    • /
    • pp.1672-1682
    • /
    • 2017
  • For grid-connected LCL-filtered inverters, the inverter-side current can be used as the control object with one current sensor for both LCL resonance damping and over-current protection, while the grid-voltage feedforward or harmonic resonant compensator is used for suppressing low-order grid current harmonics. However, it was found that the grid current harmonics were high and often beyond the standard limitations with this control. The limitations of the inverter-side current control in suppressing low-order grid current harmonics are analyzed through inverter output impedance modeling. No matter which compensator is used, the maximum magnitudes of the inverter output impedance at lower frequencies are closely related to the LCL parameters and are decreased by increasing the control delay. Then, to improve the grid current quality without complicating the control or design, this study proposes designing the filter capacitance considering the current harmonic constraint and using a PWM mode with a short control delay. Test results have confirmed the limitation and verified the performance of the improved approaches.

A High Voltage, High Side Current Sensing Boost Converter

  • Choi, Moonho;Kim, Jaewoon
    • Proceedings of the KIPE Conference
    • /
    • 2013.07a
    • /
    • pp.36-37
    • /
    • 2013
  • This paper presents high voltage operation sensing boost converter with high side current. Proposed topology has three functions which are high voltage driving, high side current sensing and low voltage boost controller. High voltage gate driving block provides LED dimming function and switch function such as a load switch of LED driver. To protect abnormal fault and burn out of LED bar, it is applied high side current sensing method with high voltage driver. This proposed configuration of boost converter shows the effectiveness capability to LED driver through measurement results.

  • PDF

New current source inverter with load-side energy recovery circuit (부하측에 에너지 회생회로를 갖는 전류원 인버터)

  • Chung, Y.H.;Cho, G.H.
    • Proceedings of the KIEE Conference
    • /
    • 1988.07a
    • /
    • pp.117-120
    • /
    • 1988
  • A new current source inverter (CSl) with dc-side commutation and load-side energy recovery circuit is proposed with analysis and explanation of the circuit operation. Proposed inverter overcomes the most drawbacks of the conventional CSI's - high device voltage stress, low operating frequency range, large commutation capacitance, etc. - by employing simultaneous recovery and commutation concept. The new CSI employs only one commutation capacitor and it can be built with considerably low cost. The commutation energies are temporarily stored into a large dc capacitor and recovered to the load side, thus the device voltage stress is low and the efficiency is high in the proposed inverter. Computer simulation results are given at the steady state, and a guideline determining the commutation circuit is given.

  • PDF

A ZVT applied SRM converter (ZVT 방식을 적용한 SRM 구동용 컨버터)

  • 김원호;조정구;김종수;임근희
    • Journal of the Korean Institute of Telematics and Electronics B
    • /
    • v.33B no.12
    • /
    • pp.106-112
    • /
    • 1996
  • A ZVT (zero voltage transition) converter for SRM (switched reluctance motor) drives is proposed in this study. By adding a ZVT-chopping switch in the front-end, all switches in the machine side converter can be operated without any chopping to regulate phase current. This allows the use of low-cost and slow-switching devices for the machine side converter. The ZVT circuitry allows high frequency operation of th echopping switch, which enhnaces the system dynamcis and phase-current ripples. High efficiency of th eintegrated converter is obtained due to low switching losses.

  • PDF

Protection coordination between residual current device and surge protective devices in low-voltage consumer's installations (저압 수용가 설비에서 누전차단기와 서지방호장치 사이의 보호협조)

  • Lee, Bok-Hee;Kim, Hoe-Gu;Park, Hee-Yeoul;Ahn, Chang-Hwan
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.27 no.6
    • /
    • pp.75-81
    • /
    • 2013
  • In this paper, protection coordination between residual current devices and surge protective devices in low-voltage consumer's distribution systems are presented. In the case that a surge protrctive device(SPD) is located on the load side of an residual current device(RCD), when the surge is injected from the source side of the RCD, most of injected surge currents are split into the RCD and the protection coordination between the SPD and RCD is improper, three of 6 specimens experience unintended operation due to test impulse currents. Also when the surges is injected from the load side, a lot of the surge currents is split into the SPD, but a half of test specimens causes nuisance trip. Coordination between SPD and RCD is not valid. When installing SPD, it is important to select SPD after due consideration of the protection voltage level of metal oxide varistor embedded in RCD. It is expected that the results obtained from this work could be useful to improve the protection effects of SPD in low-voltage distribution systems.

A Low-Computation Indirect Model Predictive Control for Modular Multilevel Converters

  • Ma, Wenzhong;Sun, Peng;Zhou, Guanyu;Sailijiang, Gulipali;Zhang, Ziang;Liu, Yong
    • Journal of Power Electronics
    • /
    • v.19 no.2
    • /
    • pp.529-539
    • /
    • 2019
  • The modular multilevel converter (MMC) has become a promising topology for high-voltage direct current (HVDC) transmission systems. To control a MMC system properly, the ac-side current, circulating current and submodule (SM) capacitor voltage are taken into consideration. This paper proposes a low-computation indirect model predictive control (IMPC) strategy that takes advantages of the conventional MPC and has no weighting factors. The cost function and duty cycle are introduced to minimize the tracking error of the ac-side current and to eliminate the circulating current. An optimized merge sort (OMS) algorithm is applied to keep the SM capacitor voltages balanced. The proposed IMPC strategy effectively reduces the controller complexity and computational burden. In this paper, a discrete-time mathematical model of a MMC system is developed and the duty ratio of switching state is designed. In addition, a simulation of an eleven-level MMC system based on MATLAB/Simulink and a five-level experimental setup are built to evaluate the feasibility and performance of the proposed low-computation IMPC strategy.

Bi-directional DC-DC Converter Design and Control for step-up/step-down (승강압용 양방향 DC-DC컨버터 설계 및 제어)

  • Won, Chung-Yuen;Jang, Su-Jin;Lee, Tae-Won;Lee, Byoung-Kuk;Kim, Soo-Suck
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.20 no.5
    • /
    • pp.49-56
    • /
    • 2006
  • The bi-directional converter interfaces the low voltage battery to the inverter do link of FC generation system. When power flows from the low voltage side(battery: 48[V]) to the high voltage side(dc link: 380[V]), the circuit works in discharge mode (boost) to power the high voltage side load; otherwise, it works in charge mode (buck) to charge the low voltage side battery. In this paper, the 1.5[kW] active clamp current-fed full bridge converter employing MOSFETs is operated to discharge the battery whereas a voltage-fed half bridge converter employing IGBTs is operated to charge the battery.

A Study on High Current Rectifier Systems with Mitigated Time-Varying Magnetic Field Generation

  • Kim, Chang-Woo;Suh, Yong-Sug
    • Proceedings of the KIPE Conference
    • /
    • 2010.07a
    • /
    • pp.232-233
    • /
    • 2010
  • This paper investigates occupational exposure to time-varying magnetic field generation in high power rectifier systems. Two different kinds of high power rectifier systems of 25kA are modeled and analyzed. The performance is compared and evaluated on the basis of exposure guidelines from ICNIRP. In order to focus on the qualitative effect of rectifier operation, the mechanical structure of current carrying conductors is simplified as infinite long bus-bar model and low frequency harmonic contents up to 65kHz are considered. Thyristor rectifier generates a significant amount of low frequency magnetic field harmonic contents both at ac and dc side of rectifier infringing the limit from ICNIRP. The multilevel rectifier-IGCT type has almost negligible field generation from ac input side and smaller harmonic contents in dc load side complying with ICNIRP guideline. This remarkable advantage of multilevel rectifier-IGCT type can lead to very simple site layout design for installation and cost-effective compliance to guideline of occupational exposure against magnetic field.

  • PDF

Analysis and Design of a DC-Side Symmetrical Class-D ZCS Rectifier for the PFC of Lighting Applications

  • Ekkaravarodome, Chainarin;Thounthong, Phatiphat;Jirasereeamornkul, Kamon;Higuchi, Kohji
    • Journal of Power Electronics
    • /
    • v.15 no.3
    • /
    • pp.621-633
    • /
    • 2015
  • This paper proposes the analysis and design of a DC-side symmetrical zero-current-switching (ZCS) Class-D current-source driven resonant rectifier to improve the low power-factor and high line current harmonic distortion of lighting applications. An analysis of the junction capacitance effect of Class-D ZCS rectifier diodes, which has a significant impact on line current harmonic distortion, is discussed in this paper. The design procedure is based on the principle of the symmetrical Class-D ZCS rectifier, which ensures more accurate results and provides a more systematic and feasible analysis methodology. Improvement in the power quality is achieved by using the output characteristics of the DC-side Class-D ZCS rectifier, which is inserted between the front-end bridge-rectifier and the bulk-filter capacitor. By using this symmetrical topology, the conduction angle of the bridge-rectifier diode current is increased and the low line harmonic distortion and power-factor near unity were naturally achieved. The peak and ripple values of the line current are also reduced, which allows for a reduced filter-inductor volume of the electromagnetic interference (EMI) filter. In addition, low-cost standard-recovery diodes can be employed as a bridge-rectifier. The validity of the theoretical analysis is confirmed by simulation and experimental results.

Mathematical Analysis of LLC Series Resonant Converter with Current Doubler Rectifier using Coupled Inductor (Coupled Inductor를 활용한 배전류 정류 회로를 적용한 LLC 직렬 공진 컨버터의 수식화 해석)

  • Shin, Jung-Yoon;Hwang, Soon-Sang;Yoon, Byung-Chul;Kim, Hag-Wone;Cho, Kwan-Yuhl
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.19 no.5
    • /
    • pp.440-449
    • /
    • 2014
  • This study proposes an LLC series resonant converter with a current doubler using a coupled inductor as a rectification circuit for the secondary side. The current doubler circuit is generally used for a high-voltage input and low-voltage output circuit to obtain high efficiency with small transformer turn ratio. However, an inductive circuit is not generally used in the secondary side of an LLC series resonant converter. If inductive components exist on the secondary side, the resonant characteristics are changed through the secondary inductive circuit. Mathematical analysis shows that the secondary-side current doubler with coupled inductor is not affected by the resonant characteristic of the primary LLC if leakage inductance occurs in the coupled inductor. Results of the analysis are proven by simulation; an experiment is also conducted for the proposed circuit.