• Title/Summary/Keyword: Low-power laser

Search Result 370, Processing Time 0.024 seconds

Effect on Tenascin Expression of Low Power Generating Laser Irradiation during Wound Healing Process (저출력 레이저가 창상치유과정에서 Tenascin 발현에 미치는 영향)

  • Sang-Bae Kim;Chong-Youl Kim
    • Journal of Oral Medicine and Pain
    • /
    • v.19 no.1
    • /
    • pp.33-43
    • /
    • 1994
  • The purpose of this paper was to observe the influence of Ga-As semiconductor-low power generating laser on she appearance and actions of tenascin, extracellular matrix, as healing process of intentional wound on the experimental animals is taking place. 35 rabbits were divided into control and experimental group. ; and on each, 3mm-long and 2mm-deep, surgical wounds were created on buccal oral mucosa and thoracodorsal portion of skin. Ga-As laser was applied to the experimental group starting a day of the day the wounds were created , the laser was applied for 5 minutes every other day. Tissue samples were taken after the 2, 4, 7, 10, and 14 days after wound formation. Then tile healing process of experimental and control groups were observed and compared, using light microscope. Afterwards, the samples were immunohistochemical stained and again observed tenascin by quantitative measuring. The following results were obtained : 1. Tenascin was observed prevalently on epithelial cells, border area of dermis, and interstitial matrix between connective tissue layers in both experimental and control groups. 2. In oral mucosa, the experimental group showed significant increase in the appearance of tenascin after 4 days compared to the control group, but after 10 days, it decreased to a point which is even less than the control group. 3. In the skin samples, the pattern of appearance of tenascin was the same in both groups, but there was some difference concerning when the peak period was shown, In the experimental group, the peak period of tenascin expression was the 7 days after wound formation in epithelium and connective tissue. In the control group, the peak period was 10 days after. 4. In both the experimental and control groups, tenascin first appeared in the epithelium near the wound area and submucosa, and then spread on the underlying connective tissue. In conclusion, appearance of tenascin is closely related to regeneration of epithelium and development of granulation tissue : therefore, low power laser, which fastnes appearance of tenascin, is sure to faciltate healing process of oral mucosa.

  • PDF

Isotope Selectivity in the CO$_2$Laser Induced Decomposition of Trichloroethylene-H and Trichloroethylene-D

  • Koo Sang Man;Chun Byung Soo;Choo Kwang Yul
    • Bulletin of the Korean Chemical Society
    • /
    • v.10 no.1
    • /
    • pp.96-101
    • /
    • 1989
  • The infrared multiphoton decomposition of trichloroethylene-H(TCE-H) and trichloroehtylene-D(TCE-D) was studied by using the high power $CO_2$ laser. The pressure dependence of TCE-H decomposition showed that the HCl elimination channel to form ClC ≡ CCl was the major step at high pressures, while the HC ≡ CCl formation step became important at low pressures. $Cl_2C$ = CHCl ${\rightarrow}$ (high pressure) ClC ${\equiv}$ CCl + HCl ${\rightarrow}$ (low pressure) HC ${\equiv}$ CCl + 2Cl${\cdot}$($Cl_2$) The IRMPD of TCE-H and TCE-D mixtures with 10P(20) laser line showed that optimum conditions of large isotope selectivity were the low system pressures and high laser powers. The experimentally observed dependence of the branching ratios on the pressure and laser fluence, and the isotope selectivity coefficients were quantitatively explained by using the modified energy grained master equations (EGME) model.

The Clinical Experiences of Laser Therapy of Patients with Pain (치료용 레이저를 이용한 통증치료 경험(II))

  • Chae, Ki-Young
    • The Korean Journal of Pain
    • /
    • v.4 no.2
    • /
    • pp.142-146
    • /
    • 1991
  • One hundred twenty patients with acute and chronic pain treated by a low power laser were divided into several groups by their pathology and evaluated according to their response rate to laser therapy through a follow-up study. 1) The ages of the patients were between the early twenties and late forties (71.7%), and there was no differences between sexes. 2) The spinal pathology group was the most common(52.5%) and the articular pathology group occupied next (14.2%). 3) The average duration of Laser therapy was about 20 days and response to the therapy appeared about the eighth day. 4) The response to the therapy in the spinal pathology group appeared about the eighth day and the average duration of therapy was about 18 days. 5) The response to the therapy in the articular pathology group appeared about the eighth day and the average duration of therapy was about 28 days. 6) The response rate of the spinal pathology group was 81.0%, and remarkable symptom relief was noted when compaired to a 58.7% response rate in the control group, 7) The response rate of the articular pathology group was 82.4%, which was similar to the control group. 8) The response rate of the miscellaneous group was 87.0%, and remarkable symptom relief was noted when compaired to a 66.7A response rate in the control group. 9) The mean response rate of all patients treated by a low power laser was 82.5% and that of the control group was 70.5%. Laser therary proved to be an effective treatment modality for acute and chronic pain.

  • PDF

Comparative Analysis of Photoplethysmography under Pulsed Magnetic Field and Low Level Laser Stimulus: Motivation for Blood Flow Increase using Stimulus on Acupoint LI4 (Hegu)

  • Kim, Young Jin;Yoo, Jun Sang;Hwang, Do Guwn;Lee, Hyun Sook
    • Journal of Magnetics
    • /
    • v.19 no.1
    • /
    • pp.32-36
    • /
    • 2014
  • The purpose of this study was to investigate the effect of pulsed magnetic field (PMF) and low frequency low level laser (LFLLL) stimuli on acupoint LI4 (Hegu) using photoplethysmography (PPG). Our PMF system was designed to generate maximum intensity of 0.20 T at a transition time of 0.16 ms, with pulse intervals of 1 Hz. The diode laser with wavelength of 650 nm and power of 5 mW was also employed. It was observed the change of the pulsating blood volume through measuring PPG signals from both hands. These results imply that stimulating acupoint LI4 with PMF and LFLLL improves the circulation of peripheral vascular system. In particular, PMF stimulation brings a big improvement of the blood flow even with short term stimulation of 3-4 minutes compared to LFLLL stimulus.

Control of Size and Morphology of Particles Using CO2 Laser in a Flame (화염증 CO2 Laser를 이용한 입자의 크기 및 형상 제어)

  • Lee, Donggeun;Lee, Seonjae;Choi, Mansoo
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.23 no.11
    • /
    • pp.1379-1389
    • /
    • 1999
  • A new technique for control of size and shape of flame-made particles is Introduced. The characteristic sintering time can be controlled Independently of collision time by heating the particles with irradiation of laser because the sintering time strongly depends on temperature. A coflow oxy-hydrogen diffusion flame burner was used for $SiCl_4$ conversion to silica particle. Nanometer sized aggregates irradiated by a high power CW $CO_2$ laser beam were rapidly heated up to high temperatures and then were sintered to approach volume-equivalent spheres. The sphere collides much slower than the aggregate, which results in reduction of sizes of particles maintaining spherical shape. Light scattering of Ar ion laser and TEM observation using a local sampling device were used to confirm the above effects. When the $CO_2$ laser was irradiated at low position from the burner surface, particle generation due to gas absorption of laser beam occurred and thus scattering intensity increased with $CO_2$ laser power. At high irradiation position, scattering intensity decreased with $CO_2$ laser power and TEM image showed a clear mark of evaporation and recondensation of particles for high $CO_2$ laser power. When the laser was irradiated between the above two positions where small aggregates exist, average size of spherical particles obviously decreased to 58% of those without $CO_2$ laser irradiation with the spherical shape. Even for increased carrier gas flow rate by a factor of three, TEM photograph also revealed considerable reduction of particle size.

Effect of Laser Acupuncture on Arterial Pulse

  • Cho, Jaekyong;Kang, Dong Hwan
    • Journal of Biomedical Engineering Research
    • /
    • v.36 no.5
    • /
    • pp.191-197
    • /
    • 2015
  • Laser acupuncture is defined as the stimulation of traditional acupuncture points with low-intensity, nonthermal laser irradiation. Possible advantages in using laser acupuncture are the noninvasive, painless and low risks of infection treatment. The purpose of this study is to assess the effect of laser acupuncture on the quality and waveform of arterial pulses. Ten acupuncture points were stimulated repeatedly three times in 30 individuals by laser with emission in the near infrared spectral region (808 nm) using an out power and power density of 45 mW and $143W/cm^2$. The analysis of pulse quality and waveform was performed based on the measurement of arterial pressure of the left and right wrist, using a 3-dimensional blood pressure pulse analyzer. Excess-like pulse quality of subjects before laser acupuncture changed significantly to balanced pulse quality after 10, 20, and 30 minutes of laser acupuncture; coefficient of deficient or excess, $C_{DE}$, decreased significantly from 0.68 before acupuncture to 0.61, 0.55, and 0.55 after 10, 20, 30 minutes of laser acupuncture ($$p{\leq_-}0.006$$), respectively. Other pulse qualities, floating or sinking, slow or rapid, choppy or slippery did not change significantly by laser acupuncture (p > 0.05). Pulse waveform analysis showed that amplitude of main peak (systolic function or aortic compliance, $h_1$) of left and right artery pulse waves decreased significantly after 10, 20, and 30 minutes of laser acupuncture (p < 0.05). Other parameters, duration of one cardiac cycle (T), duration of rapid systolic ejection ($T_1$), duration of the systolic phase ($T_4$), and duration of the diastolic phase ($T_5$) of left and right artery pulses did not change significantly after laser acupuncture (p > 0.05).

Experimental Investigation for Ablation Characteristics of Polyimide Layer and Cu-metal Layer using High Power Nd:YAG UV Laser (고출력 Nd:YAG UV레이저를 이용한 polyimide층과 Cu-metal층의 가공상태에 대한 실험적 고찰)

  • Choi, Kyung-Jin;Lee, Young-Hyun
    • Journal of the Semiconductor & Display Technology
    • /
    • v.8 no.4
    • /
    • pp.31-36
    • /
    • 2009
  • In this paper, the laser cutting characteristics of the flexible PCB using high power Nd:YAG UV laser were investigated. A specific FPCB model was selected for the experiment. Test sheets were made, which had equal materials and layer structure to those of the outline (OL) region and the contact pad (CP) region in the FPCB. The experiment is made up of two stages. In the first stage of the experiment, the laser cutting fluence was found, which is the threshold fluence to cut the test sheets completely. The laser cutting fluence of the OL sheet is $1781.26{\sim}1970.16\;J/cm^2$ and that of the CP sheet is $2109.34{\sim}2134.34\;J/cm^2$. In the second stage, cutting performance and its qualities were analyzed by the experiment. The laser cutting performance remained almost unchanged for all laser and process parameter sets. The average cutting width (top side/bottom side) of the OL sheet was $40.45\;{\mu}m/11.52\;{\mu}m$ and that of the CP sheet was $22.14\;{\mu}m/10.93\;{\mu}m$. However, the laser cutting qualities were different according to the parameters. The adjacent region of the cutting line on the OL sheet was carbonized as the beam speed was low and the overlap coefficient was high. The surface quality around the cutting line of the CP sheet was about the same. Carbonization and debris occurred on the surface of the cutting line. As a result of the experiment, the cutting qualities were better as the overlap coefficient was made low and beam speed high. Therefore, the overlap coefficient 2 or 3 is proper for the FPCB laser cutting.

  • PDF

The Characteristic of TEC Power Consumption of Laser Diode Module (레이저다이오드 모듈 냉각용 TEC 소비전력 특성)

  • Lee Jong Jin;Yu Chong Hee;Kang Hyun Seo;Koh Jai Sang
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.11 no.3 s.32
    • /
    • pp.71-76
    • /
    • 2004
  • The power consumption of TEC for Laser diode cooling was predicted by 3-D FEM simulation and verified by experiment. The operating conditions such as power consumption of Laser diode, set temperature, ambient temperature, resistance of thermal path was considered to estimate the TEC power consumption. Using 3-D FEM simulation, the relation between TEC configuration defined by the pellet dimension and the number and power consumption was investigated for low power consumption scheme. As a result, as the thermal resistance of the pellet increased, the power consumption decreased.

  • PDF

Dynamic characteristics of TbFeCo Magneto-Optical recording media at 680nm wavelength region (680nm 파장에서 TbFeCo 광자기 기록매체의 동특성)

  • Yoon, Doo-Won;Yeon, Cheong;Kim, Myong-Ryeong
    • Electrical & Electronic Materials
    • /
    • v.8 no.5
    • /
    • pp.558-563
    • /
    • 1995
  • Dynamic characteristics of TbFeCo magneto-optical recording media at 680nm wavelength region were studied by means of computer simulation of disc structure and optimization of process variables during sputter deposition. With the slightly reduced Kerr rotation angle due to the reduced wavelength of optical laser source, the improved recording density in TbFeCo magneto optical media showing the CNR greater than 50dB could be achieved by only adjusting the thickness of dielectric and the recording layers when the wavelength of light source is changed from 780nm to 680nm. In addition, the recording power margin of 5mW and the 2mW minimum recording power was realized, It was shown from the present study that the increase in laser power density demonstrated feasibility of low cost and low power laser diode with the reduced optimum recording power.

  • PDF

Implementation of Wireless Multiple Integrated Laser Engagement System using ZigBee-based Persinal Area Network (ZigBee기반 개인영역망을 사용한 무선 다중 통합 레이저 교전 시스템의 구현)

  • Ki, Hyeon-Cheol
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.14 no.4
    • /
    • pp.85-90
    • /
    • 2014
  • We realized a wireless multiple integrated laser engagement system composed of personal area network using Zigbee. The wireless laser detector had function of analog signal processor, decoder and wireless communication. However, it should consume low power and be small and light in order to be attached to a soldier's body. The decoder was realized in software to be small and light. We induced low power consumption as reducing the load of system using a narrow band optical filter. The fabricated wireless laser detector functioned well in optically noisy environment. Although the communication to the player unit through the wireless personal area network was dependent on the attachment place it was perfectly worked with transmission power of -40.2dBm or more.