• Title/Summary/Keyword: Low-k

Search Result 67,667, Processing Time 0.077 seconds

The Low-Radiation Dosimetry Application of "tris" Lyoluminescence using Electron Paramagnetic Resonance at Low Temperature

  • Son, Phil-Kook;Choi, Suk-Won;Kim, Sung-Soo;Gwag, Jin-Seog
    • Journal of Magnetics
    • /
    • v.17 no.3
    • /
    • pp.172-175
    • /
    • 2012
  • We present a method for detecting very weak radiation by analyzing the inner structure of irradiated tris (lyoluminescence) materials using electron paramagnetic resonance (EPR) at low temperature. Organic materials have been looked into for use in emergency dosimetry of inhabitants around radiation accidents. However, this technology has never been applied to imperceptible radiation doses (< 0.5 Gy) because there is no proper method for detecting the change of inner structure of the subject bombed by very weak radiation at room temperature. Our results show that tris materials can be applied as a radiation detectors of very small radiation doses below 0.05 Gray, if EPR is used at low temperature (130 K ${\leq}$ T ${\leq}$ 270 K). The EPR signal intensity from the irradiated-tris sample had barely faded at all after 1 year.

Properties of Sunglass Lenses by Non-Destructive Test for the Sunglass Standards (비파괴식 검사를 통한 선글라스의 품질에 관한 연구)

  • Lim, Yong-Moo;Shim, Moon-Sik;Sim, Hyun-Seog;Kim, Sang-Moon
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.6 no.1
    • /
    • pp.125-131
    • /
    • 2001
  • In this study, we compared the properties of 23 high and 55 low price sunglass lenses with the standards in the ordinary optical properties, materials, coloration, UV, IR and luminous transmittance, color acceptance for traffic signal, chromaticity and contrast sensitivity. The ordinary optical properties of the lenses met comparatively the requirements of the KS standard. The HIGH-type and LOW-type lenses were primarily made by glass and acrylate, respectively. In the coloration, HIGH-type was in group around neutral color but LOW-type was distributed widely on the line between 570 nm and 485 nm. There are fails in 7% of HIGH-type and 18% of LOW-type in the stimulus purity of the luminous transmittance. Wavelength of the UV/VIS cut-off was over 350 nm for HIGH-type but 6% of LOW-type was under 350 nm. In the erythemal UV, all HIGH-type met the needs of standards but 5 LOW-type failed with DIN standard In the near UV, KS standard worked in stringency, and HIGH-type showed more failure than LOW-type. The characteristics of the IR transmittance of HIGH-type was better than that of LOW-type. In the color acceptance of traffic signal, all HIGH-type met the needs of ANSI standards but 21.8% of LOW-type failed with the standard. In the contrast sensitivity tested with various coloured sunglasses, the value increased with increasing of Land decreasing of test distance. In view of the results so far, HIGH-type met with excellent properties as compared with LOW-type.

  • PDF

Degrees of Low Back Pain, Knowledge of and Educational Needs for Low Back Pain in Patients with Chronic Low Back Pain (만성 요통 환자의 통증, 지식 및 교육 요구)

  • Kim, Seong Kyong;Kim, Hee Seung;Chung, Sung Soo
    • Journal of muscle and joint health
    • /
    • v.24 no.1
    • /
    • pp.56-65
    • /
    • 2017
  • Purpose: The purposes of this study were to identify degrees of low back pain, knowledge of and educational needs for low back pain of patients with chronic low back pain and to investigate their relationships. Methods: Data were collected from questionnaires distributed to 83 patients with chronic low back pain at a hospital. Results: The low back pain score was $4.70{\pm}2.22$ out of 10. The degree of low back pain was a statistically significant difference according to gender, smoking, radiating pain and frequency and duration, daily life disturbance degree, sleep disturbance and depression. The knowledge score was 8.29 out of 13. The knowledge was a statistically significant difference according to smoking and degree of sleep disturbance. The educational needs score was 39.83 out of 50. The educational needs was a statistically significant difference according to age, duration of disease, radiating pain, standing time, depression, pain treatment experience, and treatment institutions. As the low back pain increased, the educational needs increased (r=.254, p=.021). There were no correlations between low back pain and knowledge (r=-.040, p=.720) and knowledge and educational needs (r=.061, p=.581). Conclusion: It is important to focus on items with statistically significant differences in pain, knowledge, and educational needs, and to select low knowledge and high educational needs items to develop a systematic education plan.

The Effect of Pilates and Taping on Flexibility and Muscle Strength of Low Back (필라테스와 테이핑이 허리의 유연성과 근력에 미치는 영향)

  • Suk, Bokyung;Oh, Jaewook;Lee, Sojeong;Baek, Jongyoung;Kim, Euijeong;Kim, Hyoungsu
    • Journal of The Korean Society of Integrative Medicine
    • /
    • v.1 no.1
    • /
    • pp.23-31
    • /
    • 2013
  • Purpose : This study was to investigate effects of pilates and taping on flexibility and muscular strength of low back. Methods : A total of 29 healthy over 20 years old college students(men = 6, women = 23) who were participated in this. We selected randomly for lo people of pilates, taping, and 9 people of control group. For the past six weeks, pilates worked out twice aweek for 40 minuates and taping stuck once a week for 24 hours and then we compared before and after muscle strength and flexibility of low back. Results : 1. The sesult compared of flexibility of low back have found no significant diffrences between pilates and taping groups.(P>.05) 2. The result compared of experimental groups have found significant diffrences between before and after flexibility of low back.(P<.05) 3. The result compared of muscle strength of low back have found no significant diffrences between pilates and taping groups.(P>.05) 4. The result compared of experimental groups have found significant diffrences between before and after muscle strength of low back.(P<.05) Conclusion : In conclusion there were not differences between pilates and taping on muscle strength and flexibility of low back. Those were increased in comparison with control group.

Evaluation of the effective dose and image quality of low-dose multi-detector CT for orthodontic treatment planning (3차원 안모분석을 위한 저선량 Multi-detector CT 영상의 유효선량 및 화질 평가)

  • Chung, Gi-Chung;Han, Won-Jeong;Kim, Eun-Kyung
    • Imaging Science in Dentistry
    • /
    • v.40 no.1
    • /
    • pp.15-23
    • /
    • 2010
  • Purpose : This study was designed to compare the effective doses from low-dose and standard-dose multi-detector CT (MDCT) scanning protocols and evaluate the image quality and the spatial resolution of the low-dose MDCT protocols for clinical use. Materials and Methods : 6-channel MDCT scanner (Siemens Medical System, Forschheim, Germany), was used for this study. Protocol of the standard-dose MDCT for the orthodontic analysis was 130 kV, 35 mAs, 1.25 mm slice width, 0.8 pitch. Those of the low-dose MDCT for orthodontic analysis and orthodontic surgery were 110 kV, 30 mAs, 1.25 mm slice width, 0.85 pitch and 110 kV, 45 mAs, 2.5 mm slice width, 0.85 pitch. Thermoluminescent dosimeters (TLDs) were placed at 31 sites throughout the levels of adult female ART head and neck phantom. Effective doses were calculated according to ICRP 1990 and 2007 recommendations. A formalin-fixed cadaver and AAPM CT performance phantom were scanned for the evaluation of subjective image quality and spatial resolution. Results : Effective doses in ${\mu}Sv$ ($E_{2007}$) were 699.1, 429.4 and 603.1 for standard-dose CT of orthodontic treatment, low-dose CT of orthodontic analysis, and low-dose CT of orthodontic surgery, respectively. The image quality from the low-dose protocol were not worse than those from the standard-dose protocol. The spatial resolutions of both standard-dose and low-dose CT images were acceptable. Conclusion : From the above results, it can be concluded that the low-dose MDCT protocol is preferable in obtaining CT images for orthodontic analysis and orthodontic surgery.

The Double Balance Mixer Design with the Characteristics of Low Intermodulation Distortion, and Wide Dynamic Range with Low LO-power using InGaP/GaAs HBT Process (InGaP/GaAs HBT공정을 이용하여 낮은 LO파워로 동작하고 낮은 IMD와 광대역 특성을 갖는 이중평형 믹서설계)

  • S. H. Lee;S. S. Choi;J. Y. Lee;J. C. Lee;B. Lee;J. H. Kim;N. Y. Kim;Y. H. Lee;S. H. Jeon
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.14 no.9
    • /
    • pp.944-949
    • /
    • 2003
  • In this paper, the double balance mixer(DBM) for Ku-band LNB using InGaP/GaAs HBT process is suggested for the characteristics of low DC power consumption, low noise figure, low intermodulation distortion and wide dynamic range. The 5 dB conversion gain, 14 dB NF, bandwidth 17.9 GHz and 50.34 dBc IMD are obtained under RF input power of -23 dBm, with bias condition as 3 V and 16 mA. The linearity of InGaP/GaAs HBT, the broad band input matching scheme and the optimization of bias point result in the low IMD, the broad bandwidth and the low power consumption characteristics.

Comparative Analysis on Positive Bias Stress-Induced Instability under High VGS/Low VDS and Low VGS/High VDS in Amorphous InGaZnO Thin-Film Transistors

  • Kang, Hara;Jang, Jun Tae;Kim, Jonghwa;Choi, Sung-Jin;Kim, Dong Myong;Kim, Dae Hwan
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.15 no.5
    • /
    • pp.519-525
    • /
    • 2015
  • Positive bias stress-induced instability in amorphous indium-gallium-zinc-oxide (a-IGZO) bottom-gate thin-film transistors (TFTs) was investigated under high $V_{GS}$/low $V_{DS}$ and low $V_{GS}$/high $V_{DS}$ stress conditions through incorporating a forward/reverse $V_{GS}$ sweep and a low/high $V_{DS}$ read-out conditions. Our results showed that the electron trapping into the gate insulator dominantly occurs when high $V_{GS}$/low $V_{DS}$ stress is applied. On the other hand, when low $V_{GS}$/high $V_{DS}$ stress is applied, it was found that holes are uniformly trapped into the etch stopper and electrons are locally trapped into the gate insulator simultaneously. During a recovery after the high $V_{GS}$/low $V_{DS}$ stress, the trapped electrons were detrapped from the gate insulator. In the case of recovery after the low $V_{GS}$/high $V_{DS}$ stress, it was observed that the electrons in the gate insulator diffuse to a direction toward the source electrode and the holes were detrapped to out of the etch stopper. Also, we found that the potential profile in the a-IGZO bottom-gate TFT becomes complicatedly modulated during the positive $V_{GS}/V_{DS}$ stress and the recovery causing various threshold voltages and subthreshold swings under various read-out conditions, and this modulation needs to be fully considered in the design of oxide TFT-based active matrix organic light emitting diode display backplane.

A Study on the Relationship between Tensile and Low Cycle Fatigue Properties of High Strength Material (고강도 소재의 인장과 저주기피로 물성치의 연관성에 관한 연구)

  • Park, M.K.;Suh, C.H.
    • Transactions of Materials Processing
    • /
    • v.23 no.2
    • /
    • pp.110-115
    • /
    • 2014
  • Low cycle fatigue characteristics are very important in the development of automobile suspension parts. Fatigue properties using the strain life approach are usually obtained from low cycle fatigue tests. However, low cycle fatigue testing requires a lot of time and cost. In the current study, an attempt to estimate low cycle fatigue properties of high strength steel sheet from tensile test and tensile simulations is performed. In addition, low cycle fatigue testing was conducted to compare the fatigue properties obtained from tensile testing and simulations. In conclusion, the results effectively predict the low cycle fatigue properties. However, some deviations still exist.

A Low Close-in Phase Noise 2.4 GHz RF Hybrid Oscillator using a Frequency Multiplier

  • Moon, Hyunwon
    • Journal of Korea Society of Industrial Information Systems
    • /
    • v.20 no.1
    • /
    • pp.49-55
    • /
    • 2015
  • This paper proposes a 2.4 GHz RF oscillator with a very low close-in phase noise performance. This is composed of a low frequency crystal oscillator and three frequency multipliers such as two doubler (X2) and one tripler (X3). The proposed oscillator is implemented as a hybrid type circuit design using a discrete silicon bipolar transistor. The measurement results of the proposed oscillator structure show -115 dBc/Hz close-in phase noise at 10 kHz offset frequency, while only dissipating 5 mW from a 1-V supply. Its close-in phase noise level is very close to that of a low frequency crystal oscillator with little degradation of noise performance. The proposed structure which is consisted of a low frequency crystal oscillator and a frequency multiplier provides new method to implement a low power low close-in phase noise RF local oscillator.

A Novel Algorithm for Face Recognition From Very Low Resolution Images

  • Senthilsingh, C.;Manikandan, M.
    • Journal of Electrical Engineering and Technology
    • /
    • v.10 no.2
    • /
    • pp.659-669
    • /
    • 2015
  • Face Recognition assumes much significance in the context of security based application. Normally, high resolution images offer more details about the image and recognizing a face from a reasonably high resolution image would be easier when compared to recognizing images from very low resolution images. This paper addresses the problem of recognizing faces from a very low resolution image whose size is as low as $8{\times}8$. With the use of CCTV(Closed Circuit Television) and with other surveillance camera-based application for security purposes, the need to overcome the shortcomings with very low resolution images has been on the rise. The present day face recognition algorithms could not provide adequate performance when employed to recognize images from VLR images. Existing methods use super-resolution (SR) methods and Relation Based Super Resolution methods to construct from very low resolution images. This paper uses a learning based super resolution method to extract and construct images from very low resolution images. Experimental results show that the proposed SR algorithm based on relationship learning outperforms the existing algorithms in public face databases.