• Title/Summary/Keyword: Low-intensity ultrasound

Search Result 64, Processing Time 0.023 seconds

Nattokinase Crude Extract Inhibits Hepatocellular Carcinoma Growth in Mice

  • Yan, Yongmin;Wang, Yanjing;Qian, Jiali;Wu, Sihui;Ji, Yi;Liu, Yanxiao;Zeng, Jian;Gong, Aihua
    • Journal of Microbiology and Biotechnology
    • /
    • v.29 no.8
    • /
    • pp.1281-1287
    • /
    • 2019
  • Nattokinase (NK, E.C. 3.4.21.62) is a serine protease produced by Bacillus subtilis natto that shows promise for the treatment of thrombotic disease. In this study, we assessed the effects of NK on the development of hepatocellular carcinoma (HCC), a principal malignancy of the liver that causes morbidity and mortality worldwide. Crude extracts of NK (NCE) were isolated from fermentation medium by centrifugation and separated into three fractions (<10 K, 100~30 K and >30K). Orthotopic HCC mouse models were established and NCE was administered by oral gavage. H&E staining was performed to examine the pathology of HCC livers. Immunohistochemistry and immunofluorescence were used to evaluate FOXM1, CD31, CD44 and vimentin expression in the liver. Compared to PBS groups, NCE increased the survival rates of HCC-bearing mice to 31% and decreased ascites. Low-intensity ultrasound imaging showed that the hypoechoic mass area was lower in NCE-treated mice and that tumor growth significantly decreased. IHC staining showed that the expression of FOXM1 was inhibited by NCE treatment. Immunofluorescence results revealed lower levels of CD31, CD44 and vimentin in the NCE groups. Taken together, these data demonstrate that NCE from Bacillus subtilis natto improves survival and inhibits tumor growth in HCC mice.

The Impact of Bladder Volume on Acute Urinary Toxicity during Radiation Therapy for Prostate Cancer (전립선암의 방사선치료시 방광 부피가 비뇨기계 부작용에 미치는 영향)

  • Lee, Ji-Hae;Suh, Hyun-Suk;Lee, Kyung-Ja;Lee, Re-Na;Kim, Myung-Soo
    • Radiation Oncology Journal
    • /
    • v.26 no.4
    • /
    • pp.237-246
    • /
    • 2008
  • Purpose: Three-dimensional conformal radiation therapy (3DCRT) and intensity-modulated radiation therapy (IMRT) were found to reduce the incidence of acute and late rectal toxicity compared with conventional radiation therapy (RT), although acute and late urinary toxicities were not reduced significantly. Acute urinary toxicity, even at a low-grade, not only has an impact on a patient's quality of life, but also can be used as a predictor for chronic urinary toxicity. With bladder filling, part of the bladder moves away from the radiation field, resulting in a small irradiated bladder volume; hence, urinary toxicity can be decreased. The purpose of this study is to evaluate the impact of bladder volume on acute urinary toxicity during RT in patients with prostate cancer. Materials and Methods: Forty two patients diagnosed with prostate cancer were treated by 3DCRT and of these, 21 patients made up a control group treated without any instruction to control the bladder volume. The remaining 21 patients in the experimental group were treated with a full bladder after drinking 450 mL of water an hour before treatment. We measured the bladder volume by CT and ultrasound at simulation to validate the accuracy of ultrasound. During the treatment period, we measured bladder volume weekly by ultrasound, for the experimental group, to evaluate the variation of the bladder volume. Results: A significant correlation between the bladder volume measured by CT and ultrasound was observed. The bladder volume in the experimental group varied with each patient despite drinking the same amount of water. Although weekly variations of the bladder volume were very high, larger initial CT volumes were associated with larger mean weekly bladder volumes. The mean bladder volume was $299{\pm}155\;mL$ in the experimental group, as opposed to $187{\pm}155\;mL$ in the control group. Patients in experimental group experienced less acute urinary toxicities than in control group, but the difference was not statistically significant. A trend of reduced toxicity was observed with the increase of CT bladder volume. In patients with bladder volumes greater than 150 mL at simulation, toxicity rates of all grades were significantly lower than in patients with bladder volume less than 150 mL. Also, patients with a mean bladder volume larger than 100 mL during treatment showed a slightly reduced Grade 1 urinary toxicity rate compared to patients with a mean bladder volume smaller than 100 mL. Conclusion: Despite the large variability in bladder volume during the treatment period, treating patients with a full bladder reduced acute urinary toxicities in patients with prostate cancer. We recommend that patients with prostate cancer undergo treatment with a full bladder.

Syntheses of Disubstituted Polysilanes (Ⅱ): Sonochemical Study (폴리실란의 합성 (Ⅱ): 초음파 화학적 연구)

  • 이규환;전태하
    • Journal of the Korean Chemical Society
    • /
    • v.43 no.1
    • /
    • pp.28-42
    • /
    • 1999
  • Polysilanes with sterically bulky substituents, -[2-( $R^1R^2$-phenyl)propyl]Si[$R^3$]-, such as poly(2-phenylpropyl)(n-hexyl)silane [$R^1=R^2$=H, $R^3$=n-hexyl] were prepared by Wurtz-type coupling reactions with Na using a sonochemical method. The high-intensity ultrasound provided the formation of high quality Na dispersion in toluene and its active surface which was important for the synthesis of polysilanes in Wurtz-type coupling reaction was freshly and continuously regenerated during the process. The polysilanes products were mixtures of high molecular weight polymers with $\={M}_W$ of ∼$10^6$ and low molecular weight polymers with $\={M}_W$ of ∼$10^3$. It was found that the formation of high molecular weight polymerr was greatly influenced by the substituents $R^3$, directly attached to Si. On the contrary, changes on substituents ($R^1, R^2$) gave no influences at all. Overall yields for polysilanes were 75-99% in general but high molecular weight polysilanes were obtained as a major product when substituent $R^3$ is n-hexyl group and low molecular weight polysilanes were obtained as a major product when substituent $R^3$ is cyclohexyl and 2-phenylethyl groups. Effects of reaction conditions to polysilane yields were investigated.

  • PDF

Developed an output device for high-frequency cosmetic medical equipment using micro multi-needle (마이크로 멀티니들을 이용한 고주파 피부미용 의료기기를 위한 출력 장치 개발)

  • Kim, Jun-tae;Joo, Kyu-tai;Cha, Eun Jong;Kim, Myung-mi;Jeong, Jin-hyoung
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.14 no.5
    • /
    • pp.394-402
    • /
    • 2021
  • The entry of an aging society and the extension of human life expectancy, the increasing interest in women's social advancement and men's appearance, and the natural interest in K-culture through media media, while receiving worldwide attention, Focus on K-Bueaty. Recently, looking at the occupation of the medical tourism field, in the case of aesthetic medicine tourism such as molding and dermatology, it has gained popularity not only in Asia such as China and Japan, but also in North America and Europe. The first external confirmation of human aging is the wrinkles on the skin of the face. Clean, wrinkle-free, elastic and healthy skin is a desire of most people. Skin condition and condition such as focused ultrasonic stimulation (HIFU: High Intensity Focused Utrasound) and low frequency, high frequency (RF: Radio Frequency), galvanic therapy using microcurrent, cryotherapy using rapid cooling, etc. Depending on the method of management, the effect of the treatment differs depending on the output and the stimulation site, etc., even in the treatment of medical equipment and beauty equipment using the same mechanism. In this research, in order to develop invasive high-frequency dermatological devices using a large number of beauty medical devices and microneedles of beauty devices, the international standards IEC 60601-2 (standards for individual medical devices) and MFDS (Ministry of) We designed and developed a high-frequency output device in compliance with the high-frequency stimulation standard announced in the Food and Drug Safety (Ministry of Food and Drug Safety). The circuit design consists of an amplifier (AMP: Amplifier) using Class-A Topology and a power supply device using Half-Bridge Topology. As a result of measuring the developed high-frequency output device, an average efficiency of 63.86% was obtained, and the maximum output was measured at 116.7W and 50.67dBm.