• 제목/요약/키워드: Low-flow

검색결과 6,297건 처리시간 0.029초

LARGE EDDY SIMULATION OF TURBULENT FLOWS AND DIRECT/DECOUPLED SIMULATIONS OF AEROACOUSTICS - PRESENT STATUS AND FUTURE PROSPECT -

  • Kato, Chisachi
    • 한국전산유체공학회:학술대회논문집
    • /
    • 한국전산유체공학회 2010년 춘계학술대회논문집
    • /
    • pp.2-4
    • /
    • 2010
  • Due to rapid progress in the performance of high-end computers, numerical prediction of fluid flow and flow-induced sound is expected to become a vital tool for aero- and hydro- dynamic design of various flow-related products. This presentation focuses on the applications of large-scale numerical simulations to complex engineering problems with a particular emphasis placed on the low-speed flows. Flow field computations are based on a large eddy simulation that directly computes all active eddies in the flow and models only those eddies responsible for energy dissipations. The sound generated from low-speed turbulent flows are computed either by direct numerical simulation or by decoupled methods, according to whether or not the feedback effects of the generated sound onto the source flow field can be neglected. Several numerical examples are presented in order to elucidate the present status of such computational methods and discussion on the future prospects will also be given.

  • PDF

저마하수 예조건화 기법을 이용한 무양력 전진 비행 로터 주위 유동장 해석 (ANALYSIS OF FLOW FIELD AROUND NON-LIFTING FORWARD FLIGHT ROTOR USING LOW MACH NUMBER PRECONDITIONING)

  • 김지웅;박수형
    • 한국전산유체공학회:학술대회논문집
    • /
    • 한국전산유체공학회 2008년도 학술대회
    • /
    • pp.251-255
    • /
    • 2008
  • Flow field around helicopter involves incompressible flow near the blade root and compressible flow at the blade tip. A problem occurs for low Mach number flow due to the stiffness of the governing equations. Time-derivative preconditioning techniques have been incorporated to reduce the stiffness that occurs at low speed region. The preconditioned form of the compressible Navier-Stokes and Euler equations is used. Computations are performed for the Caradonna-Tung's hovering and non-lifting forward flight case. Computational results are in good agreement with the experimental data.

  • PDF

저마하수 예조건화 기법을 이용한 무양력 전진 비행 로터 주위 유동장 해석 (ANALYSIS OF FLOW FIELD AROUND NON-LIFTING FORWARD FLIGHT ROTOR USING LOW MACH NUMBER PRECONDITIONING)

  • 김지웅;박수형
    • 한국전산유체공학회:학술대회논문집
    • /
    • 한국전산유체공학회 2008년 추계학술대회논문집
    • /
    • pp.251-255
    • /
    • 2008
  • Flow field around helicopter involves incompressible flow near the blade root and compressible flow at the blade tip. A problem occurs for low Mach number flow due to the stiffness of the governing equations. Time-derivative preconditioning techniques have been incorporated to reduce the stiffness that occurs at low speed region. The preconditioned form of the compressible Navier-Stokes and Euler equations is used. Computations are performed for the Caradonna-Tung's hovering and non-lifting forward flight case. Computational results are in good agreement with the experimental data.

  • PDF

비소음 측정을 이용한 저소음 축류홴 설계 (Design of Low Noise Axial Flow Fan Using Specific Sound Presssure Level)

  • 김창준;이동익
    • 소음진동
    • /
    • 제10권5호
    • /
    • pp.873-879
    • /
    • 2000
  • Experimental investigation was conducted to study the effects of pitch angle maximum camber on the performance and noise of an axial-flow fan used in outdoor-unit of air -conditioner. For this study the axial-flow fan whose pitch angle can be varied was made and the Specific sound Pressure Level and other coefficients were measured using the anechoic fan tester. It is found that pitch angle affects more severly than the maximum camber on the fan performance. On the while the maximum camber affects much on the specific sound power level. Present results show that it is important to choose the optimum pitch angle and maximum camber to design the high-performance and low-noise axial-flow fan and specific noise measured in the anechoic fan tester can be sued effectively for the design of low-noise fan.

  • PDF

Nonlinear Characteristics of Low-speed Flow Induced Vibration for the Safety Design of Micro Air Vehicle

  • 장태진;김동현;이인
    • 한국소음진동공학회논문집
    • /
    • 제12권11호
    • /
    • pp.873-881
    • /
    • 2002
  • The fluid induced vibration (FIV) phenomena of an equivalent airfoil system of MAV have been investigated in low Reynolds number flow region. Unsteady flows with viscosity are computed using two-dimensional incompressible Navier-Stokes equations. The present fluid/structure interaction analysis is based on one of the most accurate computational approach with computational fluid dynamics (CFD) and computational structural dynamics (CSD) techniques. The highly nonlinear fluid/structure interaction phenomena due to severe flow separations have been analyzed for the low Reynolds region that has a dominancy of flow viscosity. The effects of Reynolds number and initial angle of attack on the fluid/structure coupled vibration instability are shown and the qualitative trend of FIV phenomenon is investigated.

미소 유량 센서에 관한 실험적 연구 (Experimental Study on a Micro Flow Sensor)

  • 김태훈;김성진
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2004년도 춘계학술대회
    • /
    • pp.1783-1788
    • /
    • 2004
  • In the present paper, a micro flow sensor, which can be used at bio-delivery systems and micro heat pumps, is developed. For this, the micro flow sensor is integrated on a quartz wafer ($SiO_2$) and is manufactured by simple and convenient microfabrication processes. The micro flow sensor aims for measuring mass flow rates in the low range of about $0{\sim}20$ SCCM. The micro flow sensor is composed of temperature sensors, a heater, and a flow microchannel. The temperature sensors and the heater are manufactured by the sputtering processes in this study. In the microfabrication processes, stainless steel masks with different patterns are used to deposit alumel and chromel for temperature sensors and nichrome for the heater on the quartz wafer. The microchannel is made of Polydimethylsiloxane(PDMS) easily. A deposited quartz wafer is bonded to the PDMS microchannel by using the air plasma. Finally, we confirmed the good operation of the present micro flow sensor by measuring flow rate.

  • PDF

Numerical Studies of Flow Across End-to-Side Distal Vascular Bypass Graft Anastomoses

  • Kim, Y.H.;Kim, J.H.;Shin, J.W.
    • 대한의용생체공학회:의공학회지
    • /
    • 제13권4호
    • /
    • pp.339-352
    • /
    • 1992
  • A numerical simulation of the steady and pulsatile flow across the end-to-side anastomosis was performed In order to understand the role of flow dynamics in the preferential bevel opment of distal anastomotic intimal hyperplasla. The finite element technique was employed to solve two-dimensional unsteady pulsatile flow in that region. The results of the steady flow revealed that low shear stresses occur at the proximally occluded host artery and at the recirculation region in the Inner wall just distal to the toe region of the anastomosis. The nor- mal;zed wall shear rate was increased, as was the recirculation zone size in the host artery of the by-pass graft anastomosis, with increased anastomotic junction angle. In order to min imize the size of the low wall shear region which might result in the intimal hyperplasia in the by-pass graft anastomosis, a smaller anastomotic junction angle is recommended. The pulsatile flow simulation revealed flow that regions of low and ascillating mali shear do exist near the anastomosis as In the steady simulation. The shift of stagnation point depends on the pulsation of the flow. As the flow was accelerated at systole, the stagnation point moved downstream, disappered at early diastole and reappeared during late diastole. Low shear stress was also found along both walls of the occluded proximal artery. However, the diastolic flow behavior is quite different from the steady results. The vortex near the occluded artery moved downstream and inwardly during late systole, and disappeared during diastole. Recirculations proximal to the toe and heel regions were significant during diastole. Shear stress oscillation was found along the opposite wall. The results of the present study revealed that tow shear occurs at the proximally occluded host artery aud the recirculation region in the inner wall Just dlstal to the toe region of the anastomosis. The present study suggested that the regions of fluctuated wall shear stress wit flow separation is correlated with the preferential developing regions of anastomosis neointial fibrous hyperplasia.

  • PDF

펌프의 저 유량 운전특성에 관한 실험적 연구 (An Experimental Study on the Pump Operating Characteristics with Low Flow Operation)

  • 오광석;신필권;박종호;심우건;조두연
    • 소음진동
    • /
    • 제9권1호
    • /
    • pp.85-96
    • /
    • 1999
  • For ASME Code pumps in nuclear power plants, inservice test is required to assess the operational readiness in accordance with ASME code and related regulations. The objective of this study therefore, is to develop the technical background of the degradation of pump performances and conditions due to low flow rate operation. In addition. the detection techniques of pump operating conditions are to be developed to enhance the safety and economy of nuclear power plants. A test loop consisted of pump, motor. water tank, flow rate measurements and piping system with flow control devices was established for this study. Two typical pumps, 1-stage volute pump and 3-stage turbine pump, were selected and the test was performed upon two major point of views ; i.e., pump discharge pressure pulsations analysis and pump vibration spectrum analysis. From the test results, it is concluded that (1) the pump vibration affected by the natural frequency of operating pump is significant in the low frequency zone (around 1 Hz) : the vibration amplitude. especially. is an important factor during low flow rate operation. and shall be monitored to ensure that it is within the limit of ASME OM code Part 6, (2) the vibration frequency and pump discharge pressure are affected by vane pass frequency and running speed, (3) the wave phenomena due to the compressiblity of water is anticipated during low flow rate operation. and the pump system shall be designed to prevent it and. finally, (4) the technical background of the degradation of pump performances and conditions due to low flow rate operation is provided.

  • PDF

Performance and Flow Condition of Cross-Flow Wind Turbine with a Symmetrical Casing Having Side Boards

  • Shigemitsu, Toru;Fukutomi, Junichiro;Toyohara, Masaaki
    • International Journal of Fluid Machinery and Systems
    • /
    • 제9권2호
    • /
    • pp.169-174
    • /
    • 2016
  • A cross-flow wind turbine has a high torque coefficient at a low tip speed ratio. Therefore, it is a good candidate for use as a self-starting turbine. Furthermore, it has low noise and excellent stability; therefore, it has attracted attention from the viewpoint of applications as a small wind turbine for an urban district. However, its maximum power coefficient is extremely low (10 %) as compared to that of other small wind turbines. In order to improve the performance and flow condition of the cross-flow rotor, the symmetrical casing with a nozzle and a diffuser are proposed and the experimental research with the symmetrical casing is conducted. The maximum power coefficient is obtained as $C_{pmax}=0.17$ in the case with the casing and $C_{pmax}=0.098$ in the case without the casing. In the present study, the power characteristics of the cross-flow rotor and those of the symmetrical casing with the nozzle and diffuser are investigated. Then, the performance and internal flow patterns of the cross-flow wind turbine with the symmetrical casings are clarified. After that, the effect of the side boards set on the symmetrical casing is discussed on the basis of the analysis results.

유역모형을 이용한 비점배출계수 적용성 평가 (Evaluation of Applicability for Nonpoint Discharge Coefficient using Watershed Model)

  • 이은정;김태근
    • 환경영향평가
    • /
    • 제21권3호
    • /
    • pp.339-352
    • /
    • 2012
  • Total maximum daily load have been implemented and indicated that nonpoint discharge coeffients in flow duration curve were 0.50 of Normal flow duration ($Q_{185}$) and 0.15 of low flow duration($Q_{275}$). By using SWAT, nonpoint discharge coefficients are studied with the conditions of the instream flow and the rainfall in two study areas. The nonpoint discharge coefficient average of BOD and TP for normal flows duration in 3 years are 0.32~0.36 and 0.28~0.31. For the low flow duration, the nonpoint discharge coefficient avergae of BOD and TP were 0.10~0.12 and 0.10~0.11. These are lower than the coefficients of total maximum load regulation. There are big differences between one of regulation and one of SWAT for the normal flow duration. With the consideration of rainfall condition, the nonpoint discharge coefficient of flood flow duration are influenced on the amount of rainfalls. However, the nonpoint discharge coefficients of normal flow duration and low flow duration are not effected by the rainfall condition. Since the spatial distribution and geomorphological characteristics could be considered with SWAT, the estimation of nonpoint discharge coefficient in watershed model is better method than the use of the recommended number in the regulation.