• 제목/요약/키워드: Low-energy Building

검색결과 538건 처리시간 0.026초

국내 친환경 건축 모델하우스에 대한 비교 연구 (The Comparative Study for Green Building model house design in Korea)

  • 강연주;김문덕
    • 한국실내디자인학회논문집
    • /
    • 제21권6호
    • /
    • pp.212-223
    • /
    • 2012
  • The "Eco-friendly", "Green" concepts was began around 1992 after the Rio Environmental Summit, and the need for sustainable development globally widespread. The green building certification system was began around 2000 and the concept of green building was started in the late 1990s. The green building, which welcomes a period of radical change, is for the survival of the Earth "climate change" and reducing energy consumption in building sector. In this architecture of eco-friendly concept, the green building is rapidly expanding and existing as a ecological environment preservation. Moreover, the realization of zero energy house is to mandate for new buildings in 2025. The aim of further eco-friendly is through the prior ecosystems to restore and product energy for the 9 Green Building model houses in this paper. Building in the concept of ecology is to show about change into 7R's from the 3R's. The "Reduce", "Reuse", "Recycle" consisting of "3R's" is correlated with the traditional to the present Green Building Design. U.S. NCARB (National Council of Architectural Registration Boards) change into the concept of 7R's as "Receive", "Restore", "Respect" and "Remember", added to "3R's". In this paper, the 9 Green Building model houses do not meet the criteria of 7R's. But, the Green Tomorrow of Samsung C & T Corporation meet the 6 criteria for 7R's. This company is most comfortable at low carbon Green Building model houses. Conclusionally, introduction of eco-friendly technologies and amenities for the health of human and natural community life is to advance eco-friendly construction and enhance brand value of housing. By the way, The problem of eco-friendly architecture is initial investment and maintenance. Therefore, eco-friendly architecture and government has to try solving of this difficulty.

  • PDF

Aspects Of Architectural Design Using BIM Technologies

  • Tikhonova, Oleksandra;Selikhova, Yana;Donenko, Vasyl;Kulik, Mykhailo;Frolov, Denys;Iasechko, Maksym
    • International Journal of Computer Science & Network Security
    • /
    • 제22권1호
    • /
    • pp.85-92
    • /
    • 2022
  • In this article, we look at the application of BIM (Building Information Modeling) in sustainable infrastructures. In response to global warming, energy shortages, and environmental degradation, people are trying to build eco-friendly, low-carbon cities and promote eco-friendly homes. A "green" building is the entire life cycle of a building that includes maximizing the conservation of resources (energy, water, land, and materials), protecting the environment, reducing pollution, providing people with healthy, comfortable, and efficient use of space, and establishing harmony between nature and architecture. In the field of ecological and sustainable buildings, BIM modeling can be integrated into buildings with analog energy, air flow analysis, and solar building ecosystems. Using BIM technologies, you can reduce the amount of waste and improve the quality of construction. These technologies create "visualization" of digital building models through multidimensional digital design solutions that provide" modeling and analysis "of Scientific Collaboration Platforms for designers, architects, utility engineers, developers, and even end users. Moreover, BIM helps them use three-dimensional digital models in project design and construction and operational management.

공동주택 세대내 발코니 유형별 창호의 냉난방 에너지 성능분석 연구 (A Study on the Energy Performance Evaluation of Window System with the Balcony Types of Apartments)

  • 윤종호;안영섭;김병수;황상근
    • 한국태양에너지학회 논문집
    • /
    • 제27권1호
    • /
    • pp.83-90
    • /
    • 2007
  • Apartment balcony has been indiscreetly remodeled since the government permitted remodeling on January 2006. But remodeled balcony has a few problems such as increase of heating energy, surface condensation and cold draft. The reason of thermal problem is mainly caused by the window system in a extended balcony. The purpose of this study is to analyze heating and cooling energy and propose the efficient window types for the extended balcony area of a apartment building. 4 types of window system which have fairly high U value in Korea are investigated as follows ; double clear glass, double low-e glass, triple clear glass and triple low-e glass. Comparing double clear 91ass with double low-e glass, triple clear glass and triple low-e glass, simulation results show that 10%, 7% and 15% saving of total primary energy can be expected.

학교시설의 녹색건축 활성화를 위한 인증현황 분석 연구 - 경기도 학교시설을 중심으로 - (An Analysis on Current Status of Certification for Green Building Revitalization in School - Focused on the School Located in Gyeonggi-do Province -)

  • 김장영;김성중;이승민
    • 교육녹색환경연구
    • /
    • 제14권3호
    • /
    • pp.9-17
    • /
    • 2015
  • 본 논문에서는 경기지역을 대상으로 학교시설의 녹색건축 활성화를 위한 검증 기준인 녹색건축인증, 건축물 에너지효율등급, 에너지절약계획에 대한 항목별 적용 여부 및 계획수준을 분석하였다. 분석결과 녹색건축인증은 항목 채택 시 추가 비용이 들어가는 항목 및 유지관리가 어려운 항목은 채택비율이 낮은 것으로 분석되었다. 또한, 에너지효율등급은 학교시설 특성상 비교적 단순한 형태와 일정한 규모로 계획되고 고효율기자재 사용비율이 높아 다른 용도의 건축물에 비해 높은 등급을 보였다. 그리고 에너지성능지표(EPI)의 경우 지역별로 부문별 취득 점수에 차이가 있는 것으로 분석되었다. 특히, 경기지역의 경우 타 부문 대비 건축부문에 대한 적용점수가 낮은 것으로 나타나 단열성능 강화 시 보다 높은 점수를 취득할 수 있을 것으로 사료된다. 3가지 기준에 대한 분석결과, 다수의 시설이 학교가 취득해야 하는 의무 획득 기준에만 맞춘 형식적인 계획으로 인해 건물별 특성을 고려하지 않고 기존 획득 항목에만 맞춰 최소한의 기준만 만족하여 계획하는 패턴을 보였다. 그러나 학교시설은 녹색건축물의 확대라는 목표와 더불어 학생들의 녹색교육을 위한 토대가 되어야 하는 의무를 지닌 상징적인 건축물이다. 따라서 시설의 특성을 파악하고 건축물을 기획하는 단계부터 다양하고 합리적인 평가항목 적용이 이루어지도록 고려한 계획이 필요할 것으로 판단된다.

도시계획단계에서의 에너지 플랜트 선정을 위한 평가방안 제시 및 적용 (The Suggestion and application of the Evaluation Method for Selecting Energy Plant on City Planning Step)

  • 박진영;박률;이정재
    • 한국태양에너지학회 논문집
    • /
    • 제32권4호
    • /
    • pp.34-42
    • /
    • 2012
  • The forecasted energy shortage tends to encourage to develop the next generation energy to countermove the energy problems and the climatic change all over the world. Korean government is pushing ahead with the policy for 'Low Carbon Green Growth' to deal with climate changes and to overcome energy problems. And many studies for low carbon green city or zero carbon city have been progressed. In this study, energy plants and energy scenarios are selected by energy supply suited features of city at city plan. The method to evaluate energy scenario can be proposed to apply various energy plants for energy demand on city planning step and evaluation method can be systematized to be used by users. Also the calculated values are changed into index for comparison according to each energy scenario.

An Analytical Study on Indoor Thermal Comfort Performance According to the Automatic Control of Internal-External Blind

  • Lee, Do-Hyung;Kim, Tae-Woo;Yoon, Jong-Ho
    • KIEAE Journal
    • /
    • 제14권3호
    • /
    • pp.31-38
    • /
    • 2014
  • The purpose of this study is to analyse PMV (Predicted Mean Vote) and PPD (Predicted Percentage of dissatisfied) by automatic control of slat-type vertical blind. EnergyPlus, a building energy analysis software has been used for this study. The energy model is calibrated in Energy Plus using measured zone temperature and glass surface temperature data for one day and thermal comfort performance inside the building analysis was carried out. The calibrated data has the MBE of 4% and Cv(RMSE) of 10%. The result was that, for better zone thermal comfort, installation of blind on the outside is more appropriate than inside or no blind case. Additionally, different glazing types were compared and it was found that Triple Low-e glass is the most favorable.

건물에너지 효율등급 제도를 이용한 시나리오별 목표 온실가스 저감방안에 관한 연구 (A Study on Finding Ways to Reduce the Emission of Target Greenhouse Gases for Various Scenarios Utilizing the Building Energy Efficiency Rating)

  • 방영현;강아람;박효순;서승직
    • KIEAE Journal
    • /
    • 제12권3호
    • /
    • pp.89-94
    • /
    • 2012
  • The international community is paying close attention to the climatic changes caused by the meteorological anomalies. In response to such phenomena, after the adoption of the United Nations Framework Convention on Climate Change in 1992, efforts to actively respond to the meteorological changes are proliferating all over the world; even in the Republic of Korea, the issue to tackle the meteorological changes has emerged as a top-priority national agenda. In the year of 2008, after the declaration of the low-carbon, green-growth paradigm by the government, the UNFCCC COP15 has announced a 30% reduction target of the emission of the greenhouse gases by 2020 as compared to the "Business As Usual, BAU" and has also confirmed, as a commitment plan to achieve reduction in the emission of greenhouse gases, the reduction target of greenhouse gases for all sectors, industries and years. (26.9% for buildings) Since the construction of the new apartment houses in the year of 2001, the "Building Energy Efficiency Rating", has been applied to newly constructed building complexes, built in 2010; the accumulated emission reduction has been evaluated at around 450,000toe and the accumulated carbon dioxide emission reduction is at $826,000tCO_2$ And through the prediction of these values under various scenarios (New construction, new construction / expansion of existing uses, when transferred to 1stgrade), the effects on the degree of reduction of greenhouse gases by the increased certification of the Building Energy Efficiency Rating are an alyzed and it is our aim to express the importance of the certification system capable of carrying out a quantitative evaluation of the building energy in order to establish the strategy to reduce the emission of carbon dioxide.

옥상 뜬바닥 구조공법의 접착제 최적 배합비 산정을 위한 부착성능 실험 (Bond Performance Test for Optimum Mixing Ratio Calculation of the Floatig Floor Method on Roof-top)

  • 서유현;박준모;김옥규;정일기
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2016년도 춘계 학술논문 발표대회
    • /
    • pp.111-112
    • /
    • 2016
  • Waterproofing methods for applying to roof-top in the building are various, but it is not enough to development, which are simplified and low-cost method for old building. Especially, these buildings have not only a low insulation, but a disadvantage for energy. A floating floor method is necessary for this. This study performs an experimentt about bonding capacity of complex panel for waterproofing and heat insulation. The bond strength experiment is based on KS F 4716, and it is considered by bond mix proportion about panel and slab.

  • PDF

The Energy Analysis and Evaluation of the NEO-Hanok

  • Han, Sang Hee;Park, So Yeon;Park, Hyo Soon
    • KIEAE Journal
    • /
    • 제14권2호
    • /
    • pp.77-86
    • /
    • 2014
  • Plenty of efforts have been made in the traditional architecture of Korea, Hanok, to develop various elements such as restoration, the introduction of new design, and energy-saving while systemic setups on standard and evaluation of eco-friendly energy design of Hanok are lacking. If we evaluate energy performance based on current standards without reflecting unique features of Hanok on the system, Hanok will be included in the very low grade among the residential buildings being included in the approval system of eco-friendly architecture or the unique features will be modified and the burden of increased construction cost. Therefore, this study is to prepare the basic reference for the introductory evaluation system by evaluating the energy performance level of NEO-Hanok based on the current building energy rating system. The result for NEO-Hanok based on the building energy rating system, we propose the rating standard with scorecard elements of NEO-Hanok by considering the necessity of identity and standard for NEO-Hanok. As a result of infiltration test to check the tightness, it was measured as 10.81 times/h (50 ACH). As we switch from the main insulation for the wall from the glass wool 64k(0.035W/mk) to rigid polyurethane foam first class first unit (0.024W/mk), the result was slightly increased from the first demand quantity rating yield $249.8kWh/m^2{\cdot}yr$ to $235.0kWh/m^2{\cdot}yr$. Current certificate system is focused more on the heating load than the cooling load, it is disadvantageous for Hanok, which has less cooling energy consumption in summer. The rating result from the target building study is level 4.

노후 초등학교 건물에너지 절감을 위한 요소기술의 성능 비교 (Comparing Performances of Factors for Reducing Energy at Deteriorated Elementary School Buildings)

  • 이상춘;최영준;김현기;최율
    • KIEAE Journal
    • /
    • 제12권2호
    • /
    • pp.111-116
    • /
    • 2012
  • Faced with the international issue of environmental problems from global warming and energy consumption, the Korean Government has made many efforts on reducing energy and $CO_2$ emission under the motto of "Low-Carbon Green Growth". In order to reduce energy in the building sector, severe design standards and regulations on saving energy in new buildings have been established. Now, it is necessary to focus on deteriorated buildings where applications of energy saving designs and techniques have been insufficient, for maximizing energy saving in the building sector. Specially, it is very important to reduce energy through the remodeling process at deteriorated school buildings which were built over 20 years ago and sharply changed into the excessive energy consumption structure from new educational curricula. Thus, this paper examined the effects of potential factors to reduce energy at deteriorated elementary school buildings using the energy simulation on the Visual DOE 4.0 program. Among applied factors of insulations, southern louver, window's SHGC, indoor setup temperature, and system efficiency, all factors except window's SHGC turned out contribute to reduce energy at the deteriorated elementary school buildings, compared with the baseline energy performance.