• 제목/요약/키워드: Low-Temperature

검색결과 17,506건 처리시간 0.047초

분리형 에어컨용 2중 열교환 배관 특성에 관한 실험적 연구 (Experimental Study of Characteristics on Double Heat Exchange Pipe Used Separation Type Air-Conditioner)

  • 김재돌
    • 동력기계공학회지
    • /
    • 제10권4호
    • /
    • pp.31-37
    • /
    • 2006
  • In this study, the ability for the function of double pipe inserted liquid pipe with small diameter in the gas pipe with large diameter for the circulating of liquid of high temperature and high pressure and low temperature and low pressure at the same time is presented. And in this double pipe, liquid pipe of high temperature and pressure is used to connect condenser and expansion valve and gas pipe of low temperature is used to connect evaporator and compressor. Also, when liquid refrigerant of high temperature and gas refrigerant of low temperature is circulated by reversed flow in the double pipe. The contribution of liquid gas heat exchange pipe is studied by comparison of the effect of heat transfer by temperature difference when liquid pipe and gas pipe is installed separately.

  • PDF

극저온 물성을 고러한 콘크리트 구조물의 비선형 해석 (Nonlinear Analysis of Concrete Structure at Extremely Low Temperature)

  • 곽효경;송종영;이병국;이광모
    • 한국전산구조공학회:학술대회논문집
    • /
    • 한국전산구조공학회 2000년도 가을 학술발표회논문집
    • /
    • pp.174-181
    • /
    • 2000
  • A brief review of previous studies on the behaviour of concrete at extremely low temperature is presented in this paper. In addition, to describe temperature dependent behaviour of concrete, simple piecewise linear stress-strain relation is introduced. The proposed curve shows good agreement with experimental stress-strain curves at various temperature conditions. Moreover, numerical analyses for two PC beams are conducted to verify the influence of extremely low temperature to the structural behaviour.

  • PDF

저온잠열축열을 위한 TMA-물계 포접화합물의 냉각특성 (TMA-Water Clathrate Compound of Cooling Characteristics for Low Temperature Latent Heat Storage)

  • 김창오;정현호;정낙규
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2009년도 춘계학술발표대회 논문집
    • /
    • pp.296-301
    • /
    • 2009
  • The ice storage system uses water for low temperature latent heat storage. However, a refrigerator capacity is increased and COP is decreased due to supercooling of water in the course of phase change from solid to liquid. This study investigates the cooling characteristics of the TMA-water clathrate compound including TMA (Tri-methyl-amine, $(CH_3)_3N)$ of $20{\sim}25wt%$ as a low temperature latent heat storage material. The results showed that the phase change temperature and the specific heat is increased and the supercooling degree is decreased as the weight concentration of TMA increased. Especially, the clathrate compound containing TMA 25wt% has the average phase change temperature of $5.8^{\circ}C$, the supercooling degree of $8.0^{\circ}C$ and the specific heat of 3.499 kJ/kgK in the cooling process. This can lead to reduction of operation time of refrigerator in low temperature latent heat storage system and efficiency improvement of refrigerator COP and overall system. Therefore, energy saving and improvement of utilization efficiency are expected.

  • PDF

활어수송용 저온 컨테이너 시스템 연구 (Study of the temperature container system for a live fish transportation)

  • 윤석만;김종보;조영제;허병기
    • 설비공학논문집
    • /
    • 제10권3호
    • /
    • pp.343-347
    • /
    • 1998
  • The objective of this study is to manufacture the low temperature waterless container that is compact and low cost for a live fish transportation. Using the low temperature water container, it makes observations on the optimal conditions such as the amount of dissolved oxygen, total ammonia and nitrite in seawater for determining the survival rate of live fish in short and long-term transportation. Using a sole as a live fish, the temperatures of $0^{\circ}C$, 3$^{\circ}C$, 5$^{\circ}C$, 7$^{\circ}C$, 15$^{\circ}C$ were controled for there effects. The results of this investigation show that as the seawater temperature increased, the amount of oxygen decreased and there was a low temperature shock below 3$^{\circ}C$. It was observed that the fish was died with 30$m\ell/\ell$of ammonia. The optimal temperature is about 5$^{\circ}C$ for live fish transportation to maintain best survival rate.

  • PDF

저염 건식절임법으로 제조한 오이지의 저온저장 중 이화학적$\cdot$미생물학적 품질특성 (Physicochemical and Microbial Characteristics of Oiji Prepared with Dry Salting Methods during Low Temperature Storage)

  • 권오윤;양윤형;박완수;김미리
    • 한국식품조리과학회지
    • /
    • 제21권4호
    • /
    • pp.545-555
    • /
    • 2005
  • The physicochemical and microbial characteristics of Oiji prepared with dry salting method, which has been used industrially for industry, were investigated. Low salting and low storage temperature were employed:extremely low salting extremely low temperature; ESET $(5\%,\;0^{\circ}C)$, very low salting extremely low temperature;VSET $(10\%,\;0^{\circ}C)$, extremely low salting very low temperature; ESVT$(5\%,\;5^{\circ}C)$, low salting very low temperature; VSVT$(10\%,\;5^{\circ}C)$ and high salting low temperature;HSLT$(30\%,\;10^{\circ}C)$ for control. Acidity was lower, and pH was higher in VSET, in of which the fermentation pattern was similar with that of HSLT The time required to reach the optimum acidity ($0.3\%$ lactic acid) was longer delayed for VSET (168 days), than for compared to ESVT (51 days). During storage of Oiji, greenness (-a) as measured with of the Hunter color system wasshowed the highest in VSET, and the lowest while in ESVT, the lowest. Total microbial and lactic acid bacteria counts number were the lowest in HSLT and VSET and were the lowest than in other groups, while the highest in ESVT. Yeast was not detected in HSLT, but was the highest while in VSVT. E coli coliform and listeria were detected in the $5\%$ salting groups, although Salmonella was not detected in any of the all groups. Texture profile analysis demonstrated exhibited that fracturability and hardness were highest in HSLT and VSET, compared to the other groups. Scores of over-all preference for ESVT and HSLT were higher atwith 6.3 and 6.2, respectively, compared to the other products. Based on these results, lower saltiness less than $10\%$ and lower storage temperature (less than $5^{\circ}C$) condition was optimum for maximizing the better for good quality of industrial Oiji preparation in industry.

극저온 하에서의 일정 온도유지가 콘크리트의 열화에 미치는 영향 (The Influence of Storage at Very Low Temperatures on the Deterioration of Concrete)

  • 한상묵;조명석;송영철
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2002년도 가을 학술발표회 논문집
    • /
    • pp.667-672
    • /
    • 2002
  • Concrete cooled to very low temperature cyclically is deteriorated by ice formation in micro-pores. Although the factors to the deterioration are various, storage at very low temperature is mentioned as one of the factors. In practice, storage of cryogenic structure is kept at very low temperatures, and as such, it is important to take into consideration the influence of storage at such low temperature on the deterioration of concrete. Thus, in this study, the influence of storage on the deterioration of concrete at minimum temperatures taking into consideration the different W/C and air content.

  • PDF

중저온 열원에 의한 메탄 수증기 개질의 형상 인자에 따른 특성 (Geometric Characteristics of Methane Steam Reforming with Low Temperature Heat Source)

  • 신가희;윤진원;유상석
    • 대한기계학회논문집B
    • /
    • 제40권12호
    • /
    • pp.793-799
    • /
    • 2016
  • 폐열을 열원으로 사용하는 저온형 개질기는 하이브리드 연료전지 시스템의 효율향상을 위해 사용되고 있다. 저온형 개질기의 경우 저온의 열적상태에서 높은 열전달 효율을 내는 것이 중요하며, 이를 위한 형상 최적화의 과정이 필요하다. 본 연구에서는 제한된 열공급 상황에서 개질기의 형상인자 변화에 따른 온도 및 반응특성을 전산해석을 통하여 알아보고자 하였다. 해석결과 저온형 개질기의 반응이 활발히 일어나는 영역은 온도가 높은 후단에 제한되는 현상을 보여 고온형 개질기와의 차이를 나타내었다. 또한 개질기의 기체공간속도(Gas hourly space velocity, GHSV)를 감소시키거나 열전달 면적을 증대시킴으로써 효율을 향상 시킬 수 있음을 확인하였고 종횡비에 따른 해석을 실시한 결과 저온형 개질기의 경우 길이방향보다는 반경방향의 열전달을 증대시키는 방법이 효과적임을 확인하였다.

전부도재 수복을 위한 무색지르코니아 세라믹의 저온열화에 따른 굴곡강도 변화 (The flexural strength Changes by the Low Temperature Degradation of Uncolored zirconia Ceramic for All Ceramic Restoration)

  • 김정숙
    • 대한치과기공학회지
    • /
    • 제31권2호
    • /
    • pp.39-44
    • /
    • 2009
  • In the orthopedic field which firstly used zirconia as artificial joints, researchers had studied the reasons for collapsing zirconia used as restorative material by accumulated inner cracks in several years and they found out Low Temperature Degradation is one of the reasons. In the dentistry field, it has not been too long since they used zirconia as the cores of all-ceramic restoration; however, the study is needed as prophylactic measure against Low Temperature Degradation which can be caused by saliva wetting the mouth all the time and frictional forces such as bite pressure and masticatory pressure. Artificial aging by autoclaving is used because there are difficulties of testing in the patient's mouth. To study the changes in the material properties, the flexural strength of dental zirconia ceramic is measured before and after the test. The following are the result of the test. 1) The zirconia blocks in the autoclaves at $130^{\circ}C$ and $200^{\circ}C$ are phase-shifted tetragonal to monoclinic by Low Temperature Degradation. 2)The non-autoclaved specimens have the average fractural strength of 1346.4MPa, the specimens autoclaved at $130^{\circ}C$ have 1226.4Mpa and the specimens autoclaved at $200^{\circ}C$ have 1024.1MPa. The tests show that as the temperature increases, the flexural strength tend to decrease and the differences are noticeable(p<0.001). 3)Through the Duncan's post-hoc test, the differences in flexural strength of the 3 groups were listed in order of strength like normal temperature>at $130^{\circ}C$ autoclave low temperature degradation> at $200^{\circ}C$ autoclave low temperature degradation.

  • PDF

Effect of the Neutral Beam Energy on Low Temperature Silicon Oxide Thin Film Grown by Neutral Beam Assisted Chemical Vapor Deposition

  • So, Hyun-Wook;Lee, Dong-Hyeok;Jang, Jin-Nyoung;Hong, Mun-Pyo
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2012년도 제43회 하계 정기 학술대회 초록집
    • /
    • pp.253-253
    • /
    • 2012
  • Low temperature SiOx film process has being required for both silicon and oxide (IGZO) based low temperature thin film transistor (TFT) for application of flexible display. In recent decades, from low density and high pressure such as capacitively coupled plasma (CCP) type plasma enhanced chemical vapor deposition (PECVD) to the high density plasma and low pressure such as inductively coupled plasma (ICP) and electron cyclotron resonance (ECR) have been used to researching to obtain high quality silicon oxide (SiOx) thin film at low temperature. However, these plasma deposition devices have limitation of controllability of process condition because process parameters of plasma deposition such as RF power, working pressure and gas ratio influence each other on plasma conditions which non-leanly influence depositing thin film. In compared to these plasma deposition devices, neutral beam assisted chemical vapor deposition (NBaCVD) has advantage of independence of control parameters. The energy of neutral beam (NB) can be controlled independently of other process conditions. In this manner, we obtained NB dependent high crystallized intrinsic and doped silicon thin film at low temperature in our another papers. We examine the properties of the low temperature processed silicon oxide thin films which are fabricated by the NBaCVD. NBaCVD deposition system consists of the internal inductively coupled plasma (ICP) antenna and the reflector. Internal ICP antenna generates high density plasma and reflector generates NB by auger recombination of ions at the surface of metal reflector. During deposition of silicon oxide thin film by using the NBaCVD process with a tungsten reflector, the energetic Neutral Beam (NB) that controlled by the reflector bias believed to help surface reaction. Electrical and structural properties of the silicon oxide are changed by the reflector bias, effectively. We measured the breakdown field and structure property of the Si oxide thin film by analysis of I-V, C-V and FTIR measurement.

  • PDF

AC PDP의 온도에 따른 방전 특성 연구 (A Study on the Temperature-Dependent Discharge Characteristics in Alternating Current Plasma Display Panel)

  • 이석현;김지용
    • 전기학회논문지
    • /
    • 제56권3호
    • /
    • pp.577-582
    • /
    • 2007
  • The plasma display panel is an image expression display using gas discharge plasma. However, gas discharge characteristics vary with temperature as gas discharge is sensitive to temperature. The discharge time lag extends a lot in low temperature and it is known as the cause which hinders high speed addressing which is essential for the size enlargement of the panel. Accordingly this research aims at identifying the temperature-dependent discharge characteristic. The lower temperature becomes, the longer addressing discharge time lag becomes. Particularly the statistical time lag extends much in low temperature. The increasing of electric field shortens discharge time lag in low temperature. Also, when priming particles are sufficiently supplied, stable discharge can be performed regardless of the influence of temperature.