• Title/Summary/Keyword: Low-Interaction

Search Result 2,192, Processing Time 0.03 seconds

The Increment Of The Local Scour Depth At Piers By Constructing The Bridge Between Existing Bridges

  • Choi, Gye-Woon;Kim, Gee-Hyoung
    • Water Engineering Research
    • /
    • v.1 no.2
    • /
    • pp.159-168
    • /
    • 2000
  • In this paper, the increment of the local scour depth at piers by constructing the bridge between existing bridges is examined through the experiments in which 5 piers in the non-cohesive bed material in the experimental flume were installed. In the experiments the maximum distance of 25 times of the pier length and the maximum distortion width of 8 times of the pier width were utilized. Through the experimental studies, it was indicated that low flow, which can be characterized as the flow having low Froude numbers, the maximum bed configuration change is obtained when the piers are installed in the straight line in the flor direction without any distortion. However, In the high flow, which can be characterized as the flow having high Froude numbers, the maximum bed configuration change is obtained when the piers are installed with some distortion from the flow direction. The influence of the bed configuration by interaction between bridge piers is changed depending upon the Froude numbers, the distance between piers, and the distortion width between adjacent bridge piers. Also, because the scour patterns are affected by the bed configuration, the maximum scour should be increased by about 60% compared to that in a single pier if the interaction between bridge piers exists. It can be suggested that the maximum scour depth at bridge piers predicted by applying the existing equations should be increased if the interaction between bridge piers exist. Those cases are found when new bridges are constructed successively in the river in the urban area.

  • PDF

정익과 동익의 상호작용에 의한 비정상 천이 경계층 유동의 수치해석에 관한 연구 1

  • Kang, Dong-Jin;Lakshminarayana, Budugur
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.22 no.6
    • /
    • pp.757-770
    • /
    • 1998
  • A Navier-Stokes code with a low Reynolds number k-.epsilon. turbulence model was tested to investigate its predictability for the unsteady transitional boundary layer flow due to rotor-stator interaction. A preliminary calculation with three different numbers of time steps 300, 600, and 1000 for a rotor wake passing period was carried out to see the effects of time steps on the unsteady flow and pressure fields due to rotor-stator interaction. Numerical solutions showed that unsteady pressure was much more sensitive to the number of time steps and over 600 time steps should be used to get a numerical solution independent of the number of time steps for a rotor wake passing period. The original low Reynolds number k-.epsilon. turbulence model showed very poor prediction of the unsteady transitional boundary layer flow due to rotor-stator interaction. This was due to the excessive production of turbulent kinetic energy near the leading edge. A modification suggested by Launder was incorporated and the modified model captured well the wake induced transitional strip. Present solutions also showed improved prediction over previous Euler/boundary layer solution in terms of the onset of unsteady transition and its extent.

Numerical Prediction of Unsteady Transitional Boundary Layer Flows due to Rotor-Stator Interaction(II)-Characteristics of Unsteady Transitional Boundary Layer Flow- (정익과 동익의 상호작용에 의한 비정상 천이 경계층 유동의 수치해석에 관한 연구 (II))

  • Kang, Dong-Jin;Lakshminarayana, Budugur
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.22 no.6
    • /
    • pp.771-787
    • /
    • 1998
  • A Navier-Stokes code with a modified low Reynolds number k-.epsilon. turbulence model was used to study the unsteady transitional boundary layer flow due to rotor-stator interaction. The modification, proposed by Launder, to improve prediction of stagnation flows was incorporated to the low Reynolds number k-.epsilon. turbulence model by Fan-Lakshminarayana-Barnett. Numerical solution is shown to capture well the calmed laminar flow as well as the wake induced transitional strip due to rotor-stator interaction and shows improvement, in terms of onset of transition and its length, over previous Euler/boundary layer solution. The turbulent kinetic energy shows local maximum along the upstream rotor wake in the wake induced transitional strip and this characteristics is observed untill the end of transition. The wake induced strip also shown apparent even in the laminar sublayer as the upstream rotor wake penetrates inside the boundary layer.

Effect of Heterogeneous Variance by Sex and Genotypes by Sex Interaction on EBVs of Postweaning Daily Gain of Angus Calves

  • Oikawa, T.;Hammond, K.;Tier, B.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.12 no.6
    • /
    • pp.850-853
    • /
    • 1999
  • Angus postweaning daily gain (PWDG) was analyzed to investigate effects of the heterogeneous variance and the genotypes by sex interaction on prediction of EBVs with data sets of various environmental levels. A whole data (16,239 records) was divided into six data sets according to averages of the best linear unbiased estimator (BLUE) of herd environment. The results comparing prediction models showed that single-trait model is adequate for most of the data sets except for the data set of poor environment for both of the bulls and the heifers where the heterogeneity of variance and the genotypes by sex interaction exists. In the prediction with the data set of the low environment level, the bull's EBVs by single-trait models had high product moment correlations with male EBVs of the bulls by the multitrait model. Whereas the heifer's EBVs had moderate correlations with female EBVs by the multitrait model. This moderate correlation seems to be resulted by the heterogeneity of variance and low heritability of the heifer's PWDG. The prediction models with heterogeneity of variance had little effect on the prediction of EBVs for the data sets with moderate to high genetic correlations.

Electrical Transport Properties of La0.5Sr0.5CrO3 Ceramics (La0.5Sr0.5CrO3 세라믹스의 전기전도특성)

  • Jung, Woo-Hwan
    • Korean Journal of Materials Research
    • /
    • v.26 no.1
    • /
    • pp.35-41
    • /
    • 2016
  • The electrical transport properties of $La_{0.5}Sr_{0.5}CrO_3$ below room temperatures were investigated by dielectric, dc resistivity, magnetic properties and thermoelectric power. Below $T_c$, $La_{0.5}Sr_{0.5}CrO_3$ contains a dielectric relaxation process in the tangent loss and electric modulus. The $La_{0.5}Sr_{0.5}CrO_3$ involves the transition from high temperature thermal activated conduction process to low temperature one. The transition temperature corresponds well to the Curie point. The relaxation mechanism has been discussed in the frame of electric modulus spectra. The scaling behavior of the modulus suggests that the relaxation mechanism describes the same mechanism at various temperatures. The low temperature conduction and relaxation takes place in the ferromagnetic phase. The ferromagnetic state in $La_{0.5}Sr_{0.5}CrO_3$ indicates that the electron - magnon interaction occurs, and drives the carriers towards localization in tandem with the electron - lattice interaction even at temperature above the Curie temperature.

A Study on the Life Prediction Method using Artificial Neural Network under Creep-Fatigue Interaction (인공 신경망을 이용한 크리프-피로 상호작용시 수명예측기법에 관한 연구)

  • 권영일;김범준;임병수
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.9 no.6
    • /
    • pp.135-142
    • /
    • 2001
  • The effect of tensile hold time on the creep-fatigue interaction in AISI 316 stainless steel was investigated. To study the fatigue characteristics of the material, strain controlled low cycle fatigue(LCF) tests were carried out under the continuous triangular waveshape with three different total strain ranges of 1.0%, 1.5% and 2.0%. To study the creep-fatigue interaction, 5min., 10min., and 30min. of tensile hold times were applied to the continuous triangular waveshape with the same three total strain ranges. The creep-fatigue life was found to be the longest when the 5min. tensile hold time was applied and was the shortest when the 30min. tensile hold time was applied. The cause fur the shortest creep-fatigue life under the 30min. tensile hold time is believed to be the effect of the increased creep damage per cycle as the hold time increases. The creep-fatigue life prediction using artificial neural network(ANN) showed closer prediction values to the experimental values than by the modified Coffin-Manson method.

  • PDF

Study on the Output Current for Electrochemical Low-energy Neutrino Detector with Regards to Oxygen Concentration

  • Suda, Shoya;Ishibashi, Kenji;Riyana, Eka Sapta;Aida, Yani Nur;Nakamura, Shohei;Imahayashi, Yoichi
    • Journal of Radiation Protection and Research
    • /
    • v.41 no.4
    • /
    • pp.373-377
    • /
    • 2016
  • Background: Experiments with small electrochemical apparatus were previously carried out for detecting low-energy neutrinos under irradiation of reactor neutrinos and under natural neutrino environment. The experimental result indicated that the output current of reactor-neutrino irradiated detector was appreciably larger than that of natural environmental one. Usual interaction cross-sections of neutrinos are quite small, so that they do not explain the experimental result at all. Materials and Methods: To understand the experimental data, we propose that some biological products may generate AV-type scalar field B0, leading to a large interaction cross-section. The output current generation is ascribed to an electrochemical process that may be assisted by weak interaction phenomena. Dissolved oxygen concentrations in the detector solution were measured in this study, for the purpose of understanding the mechanism of the detector output current generation. Results and Discussion: It was found that the time evolution of experimental output current was mostly reproduced in simulation calculation on the basis of the measured dissolved oxygen concentration. Conclusion: We mostly explained the variation of experimental data by using the electrochemical half-cell analysis model based on the DO concentration that is consistent to the experiment.

The Effects of Swiping Orientation on Preference and Willingness to Pay: The Interaction Between Touch Interface and Need-For-Touch

  • Ren, Han;Kang, Hyunmin;Ryu, Soohyun;Han, Kwanghee
    • Science of Emotion and Sensibility
    • /
    • v.20 no.4
    • /
    • pp.65-78
    • /
    • 2017
  • The current study examined the influence of individual trait such as Need-For-Touch level (NFT; high vs. low) and swiping orientation (vertical vs. horizontal) on product evaluation and preference when using touch-screen interface like a smart phone and a tablet. Swiping is one of the most common interaction techniques for changing pages or searching some aligned pictures on touch-screen interface and it can be used in vertical and horizontal orientations. The experiment revealed a significant interaction between swiping orientation and NFT on preference, however the interaction on change-in-price of given products was only marginally significant. To be specific, high NFT participants reported higher preference for horizontal-swipe than vertical-swipe products, but such difference did not occur with low NFT participants. The current study illustrates the influence of swiping orientation and NFT on product preference and it provides a new perspective of design principles especially for online shopping websites.

Magnetic Interaction Effect on Activation Volume and Area of CoPt Magnetic Films (자성막 CoPt의 자기상호작용이 활성화 부피와 면적에 미치는 영향)

  • Kim, Hyeon Soo;Jeong, Soon Young;Suh, Su Jeong
    • Journal of the Korean Magnetics Society
    • /
    • v.23 no.6
    • /
    • pp.188-192
    • /
    • 2013
  • The magnetic interaction effect on the magnetic activation volume and area of electrodeposited CoPt magnetic films was investigated. The dipolar interaction was predominant interaction mechanism for all samples. And the interaction strength was increased with decreasing current density and increased with increasing sample thickness. Although the activation volumes of the samples fabricated at low current density were larger than those of the high current density samples, the sample thickness seemed to have little influence on the variation of activation volume. But it was found that the activation area was apparently affected by the magnetic interaction strength as well as the current density.

2-D Inviscid Analysis of Flow in One Stage of Axial Compressor (1단 축류압축기 내부 유동의 2차원 비점성 해석)

  • Kim HyunIl;Park JunYoung;Baek JeHyun;Jung HeeTaek
    • Journal of computational fluids engineering
    • /
    • v.5 no.2
    • /
    • pp.38-46
    • /
    • 2000
  • It has been indicated that the rotor/stator interaction has distinct causes of unsteadiness, such as the viscous vortex shedding, wake/stator interaction and potential rotor/stator interaction. In this paper, the mechanism of unsteady potential interaction in one stage axial compressor is numerically investigated for blade row ratio 1:1 and 2:3 at design point and for blade row ratio 2:3 at off-design point in two-dimensional view point. The numerical technique used is the upwind scheme of Van-Leer's Flux Vector Splitting(FVS) and Cubic spline interpolation is applied on zonal interface. In this study the flow unsteadiness due to potential interaction are found to be larger in blade row ratio 2:3 than in 1:1. The total pressure rise in blade row ratio 2:3 is closer to the real value in design point than that in 1:1. The change of unsteady pressure amplitude according to the variation of stator exit pressure is very small.

  • PDF