• Title/Summary/Keyword: Low-Code

Search Result 1,645, Processing Time 0.047 seconds

Development of $^{166}Ho$-Stent for the Treatment of Esophageal Cancer (식도암 치료용 $^{166}Ho$-Stent 개발)

  • Park, Kyung-Bae;Kim, Young-Mi;Kim, Kyung-Hwa;Shin, Byung-Chul;Park, Woong-Woo;Han, Kwang-Hee;Chung, Young-Ju;Choi, Sang-Mu;Lee, Jong-Doo
    • The Korean Journal of Nuclear Medicine
    • /
    • v.34 no.1
    • /
    • pp.62-73
    • /
    • 2000
  • Purpose: Esophageal cancer patients have a difficulty in the intake of meals through the blocked esophageal lumen, which is caused by an ingrowth of cancer cells and largely influences on the prognosis. It is reported that esophageal cancer has a very low survival rate due to the lack of nourishment and immunity as the result of this. In this study a new radioactive stent, which prevents tumor ingrowth and restenosis by additional radiation treatment, has been developed. Materials and Methods: Using ${\ulcorner}HANARO{\lrcorner}$ research reactor, the radioactive stent assembly ($^{166}Ho$-SA) was prepared by covering the metallic stent with a radioactive sleeve by means of a post-irradiation and pre-irradiation methods. Results: Scanning electron microscopy and autoradiography exhibited that the distribution of $^{165/166}Ho\;(NO_3)$ compounds in polyurethane matrix was homogeneous. A geometrical model of the esophagus considering its structural properties, was developed for the computer simulation of energy deposition to the esophageal wall. The dose distributions of $^{166}Ho$-stent were calculated by means of the EGS4 code system. The sources are considered to be distributed uniformly on the surface in the form of a cylinder with a diameter of 20 mm and length of 40 mm. As an animal experiment, when radioactive stent developed in this study was inserted into the esophagus of a Mongrel dog, tissue destruction and widening of the esophageal lumen were observed. Conclusion: We have developed a new radioactive stent comprising of a radioactive tubular sleeve covering the metallic stent, which emits homogeneous radiation. If it is inserted into the blocked or narrowed lumen, it can lead to local destruction of the tumor due to irradiation effect with dilatation resulting from self-expansion of the metallic property. Accordingly, it is expected that restenosis esophageal lumen by the continuous ingrowth and infiltration of cancer after insertion of our radioactive stent will be decreased remarkably.

  • PDF

Cumulative Risk Assessment of Organophosphorus Pesticides in the Diet (식품을 통한 유기인계농약류의 동시노출위해성평가)

  • 이효민;한지연;윤은경;김효미;황인균;최동미;이강봉;원경풍;송인상
    • Journal of Food Hygiene and Safety
    • /
    • v.16 no.1
    • /
    • pp.21-26
    • /
    • 2001
  • Risk assessment traditionally are conducted on individual chemicals; however, humans are exposed to multiple chemicals in daily life. The organophosphorus (OP) pesticides are considered in a single risk assessment because they act by a common mechanism of toxicity, and there is likely to be expose to multiple OP pesticides simultaneously or sequentially. The OP pesticides act by inhibiting the enzyme acetylcholinesterasc (AChE) and have available extensive database. AChE is widely distributed throughout the body, most importantly in the nervous system. Inhibition of AChE results in accumulation of acetylcholine in the nervous system that results in clinical signs of cholinergic toxicity, including increased salivation and lacrimation, nausea and vomiting, muscle fasciculation, lethargy and fatigue, among others. To conduct an exposure assessment for pesticides in the diet, we need to know the food consumption patterns of the populations, and the pesticide residue levels in the foods that are consumed. This study was conducted to identify cumulative dietary risk due to multiple OP pesticides that can be exposed through various foods. Total 22 food samples including cereals, vegetables and fruits were collected randomly two times from food markets in several sites (4 cities). The subjected foods were selected by regarding of highly consumed foods to general Korean people. The 12 OP pesticides including Acephate, Azinphos-methyl, Chlorpyrifos, and Diazinon were monitored. For the exposure assessment, general adult group of 60 kg body weight was regarded as target population and food consumption data suggested by Lee et al. (2000) were used as consumed value of individual food. Analyses of samples for OP pesticides have been carried out according to the multiclass multiresidue analysis method and acephate and methamidophos analysis method of Korea Food Code. In general the levels of OP pesticides found in the food samples were very low or not detected.

  • PDF

Exploratory Case Study for Key Successful Factors of Producy Service System (Product-Service System(PSS) 성공과 실패요인에 관한 탐색적 사례 연구)

  • Park, A-Rum;Jin, Dong-Su;Lee, Kyoung-Jun
    • Journal of Intelligence and Information Systems
    • /
    • v.17 no.4
    • /
    • pp.255-277
    • /
    • 2011
  • Product Service System(PSS), which is an integrated combination of product and service, provides new value to customer and makes companies sustainable as well. The objective of this paper draws Critical Successful Factors(CSF) of PSS through multiple case study. First, we review various concepts and types in PSS and Platform business literature currently available on this topic. Second, after investigating various cases with the characteristics of PSS and platform business, we select four cases of 'iPod of Apple', 'Kindle of Amazon', 'Zune of Microsoft', and 'e-book reader of Sony'. Then, the four cases are categorized as successful and failed cases according to criteria of case selection and PSS classification. We consider two methodologies for the case selection, i.e., 'Strategies for the Selection of Samples and Cases' proposed by Bent(2006) and the seven case selection procedures proposed by Jason and John(2008). For case selection, 'Stratified sample and Paradigmatic cases' is adopted as one of several options for sampling. Then, we use the seven case selection procedures such as 'typical', 'diverse', 'extreme', 'deviant', 'influential', 'most-similar', and 'mostdifferent' and among them only three procedures of 'diverse', 'most?similar', and 'most-different' are applied for the case selection. For PSS classification, the eight PSS types, suggested by Tukker(2004), of 'product related', 'advice and consulancy', 'product lease', 'product renting/sharing', 'product pooling', 'activity management', 'pay per service unit', 'functional result' are utilized. We categorize the four selected cases as a product oriented group because the cases not only sell a product, but also offer service needed during the use phase of the product. Then, we analyze the four cases by using cross-case pattern that Eisenhardt(1991) suggested. Eisenhardt(1991) argued that three processes are required for avoiding reaching premature or even false conclusion. The fist step includes selecting categories of dimensions and finding within-group similarities coupled with intergroup difference. In the second process, pairs of cases are selected and listed. The second step forces researchers to find the subtle similarities and differences between cases. The third process is to divide the data by data source. The result of cross-case pattern indicates that the similarities of iPod and Kindle as successful cases are convenient user interface, successful plarform strategy, and rich contents. The differences between the successful cases are that, wheares iPod has been recognized as the culture code, Kindle has implemented a low price as its main strategy. Meanwhile, the similarities of Zune and PRS series as failed cases are lack of sufficient applications and contents. The differences between the failed cases are that, wheares Zune adopted an undifferentiated strategy, PRS series conducted high-price strategy. From the analysis of the cases, we generate three hypotheses. The first hypothesis assumes that a successful PSS system requires convenient user interface. The second hypothesis assumes that a successful PSS system requires a reciprocal(win/win) business model. The third hypothesis assumes that a successful PSS system requires sufficient quantities of applications and contents. To verify the hypotheses, we uses the cross-matching (or pattern matching) methodology. The methodology matches three key words (user interface, reciprocal business model, contents) of the hypotheses to the previous papers related to PSS, digital contents, and Information System (IS). Finally, this paper suggests the three implications from analyzed results. A successful PSS system needs to provide differentiated value for customers such as convenient user interface, e.g., the simple design of iTunes (iPod) and the provision of connection to Kindle Store without any charge. A successful PSS system also requires a mutually benefitable business model as Apple and Amazon implement a policy that provides a reasonable proft sharing for third party. A successful PSS system requires sufficient quantities of applications and contents.

Standardization of the Method of Measuring Average Glandular Dose (AGD) and Evaluation of the Breast Composition and Thickness for AGD (평균 유선선량 측정방법의 표준화 및 유방 두께, 실질양상과의 상관관계 분석)

  • Park, Hye-Suk;Kim, Hee-Joung;Lee, Chang-Lae;Cho, Hyo-Min;Yu, A-Ram
    • Progress in Medical Physics
    • /
    • v.20 no.1
    • /
    • pp.21-29
    • /
    • 2009
  • Breast cancer is the most common form of cancer among korean woman. Therefore, the early detection activities of breast cancer such as breast self-examinations, clinical breast examinations, mammography are important. A yearly mammography examination has been recommended for women aged 40 and older for the early detection of breast cancer in asymptomatic periods. However, the glandular tissue of breast is the most radiation-sensitive tissue, and the determination of average glandular dose (AGD) forms an important part of the quality control of the mammographic systems. Because of the difficulty of estimating AGD directly, it is often estimated from the measurements of the incident air kerma and by applying the appropriate conversion factors. The primary objective of this study was to standardize the method of measuring AGD. The secondary objective was to evaluate the relationships between AGD per various composition and thickness of the breast using Monte Carlo simulations. As a result, we standardized the method of measuring AGD according to International Atomic Energy Agency (IAEA) guidelines (CoP: an international code of practice). Overall, AGD for mammographic practice in Korea was less than 3.0 mGy recommended by the Korea Food and Drug Adminstration (KFDA) protocol, and Korean Institute for Accreditation of Medical Image (KIAMI). The measured and simulated AGD for a given condition were calculated as 1.7 and 1.6 mGy, respectively. For the AGDs obtained, there was no significant difference between them. The simulated AGD was dependent on the fraction of glandular tissue of the breast. The AGD increases with increasing of the breast glandularity due to increasing absorption of low energy photons. The AGD also increases as a function of breast thickness. In conclusion, the results of this study could be used as a baseline to establish a reference level of radiation dose in mammography.

  • PDF

Ship's Hull Fouling Management and In-Water Cleaning Techniques (선체부착생물관리와 수중제거기술)

  • Hyun, Bonggil;Jang, Pung-Guk;Shin, Kyoungsoon;Kang, Jung-Hoon;Jang, Min-Chul
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.24 no.6
    • /
    • pp.785-795
    • /
    • 2018
  • The International Maritime Organization (IMO) has recognized the risk of hull fouling and announced '2011 Guidelines for the control and management of ship's biofouling to minimize the transfer of invasive aquatic species'and is planning international regulations to enforce them in the future. In this study, to effectively respond to future international regulation, we introduce the case of leading countries related to management of hull fouling and also investigate environmental risk assessment techniques for in-water cleaning. Australia and New Zealand, the leading countries in hull fouling management, have established hull fouling regulations through biological and chemical risk assessment based on in-water cleaning scenarios. Most European countries without their government regulation have been found to perform in-water cleaning in accordance with the IMO's hull fouling regulations. In the Republic of Korea, there is no domestic law for hull fouling organisms, and only approximately 17 species of marine ecological disturbance organisms, are designated and managed under the Marine Ecosystem Law. Since in-water cleaning is accompanied by diffusion of alien species and release of chemical substances into aquatic environments, results from biological as well as chemical risk assessment are performed separately, and then evaluation of in-water cleaning permission is judged by combining these two results. Biological risk assessment created 40 codes of in-water cleaning scenarios, and calculated Risk Priority Number (RPN) scores based on key factors that affect intrusion of alien species during in-water cleaning. Chemical risk assessment was performed using the MAMPEC (Marine Antifoulant Model to Predict Environmental Concentrations), to determine PEC and PNEC values based on copper concentration released during in-water cleaning. Finally, if the PEC/PNEC ratio is >1, it means that chemical risk is high. Based on the assumption that the R/V EARDO ship performs in-water cleaning at Busan's Gamcheon Port, biological risk was estimated to be low due to the RPN value was <10,000, but the PEC/PNEC ratio was higher than 1, it was evaluated as impossible for in-water cleaning. Therefore, it will be necessary for the Republic of Korea to develop the in-water cleaning technology by referring to the case of leading countries and to establish domestic law of ship's hull fouling management, suitable for domestic harbors.

Extending the Shelf-life of Yukwa Using Secondary Packaging (이차포장을 통한 유과의 저장성 연장)

  • Jung, Jun-Jae;Lee, Keun-Taik
    • Korean Journal of Food Science and Technology
    • /
    • v.42 no.4
    • /
    • pp.452-458
    • /
    • 2010
  • This study aimed at improving the packaging technology of Yukwa to improve the quality and extend the shelflife using secondary packaging. After packaging the Yukwa using an OPP film, P2, P3, and P4 packaging materials were applied secondarily. Various films including (1) P1: OPP (oriented polypropylene), (2) P2: P1+OPP/LLDPE (linear low density polyethylene), (3) P3: P1+PET (polyethylene terephthalate)/NY (nylon)/CPP (cast polypropylene) and (4) P4: P1+PET/AL (aluminum)/NY/CPP (P4) were used for packaging Yukwa. The experiment was conducted at $25^{\circ}C$ for 12 weeks. P1 showed the highest acid value score (1.26 mg KOH/g), and P3 had the highest peroxide value score (32.91 meq/kg) among all packaging groups. Nevertheless, these values did not exceed the guideline values of 2.0 g KOH/g and 40 meq/kg specified in the Korean food code. The overall color difference showed a tendency for decreasing Hunter 'L' values and increasing 'a' and 'b' values; however, no noticeable difference in the outer appearance was observed in any of the packaging treatments except in the P1 for greater than 10 weeks of storage. Some texture defects were observed in the Yukwa when the moisture contents dropped below 5%. The P4 packaging treatment had the lowest moisture permeability and showed the least rheological deterioration change, followed by P3 and P2. In conclusion, the use of a secondary packaging with less gas and moisture permeability was more effective for maintaining the quality and extending the shelf-life of Yukwa than other types of packaging material.

Preliminary Post-closure Safety Assessment of Disposal Options for Disused Sealed Radioactive Source (폐밀봉선원 처분방식별 폐쇄후 예비안전성평가)

  • Lee, Seunghee;Kim, Juyoul;Kim, Sukhoon
    • Economic and Environmental Geology
    • /
    • v.49 no.4
    • /
    • pp.301-314
    • /
    • 2016
  • Disused Sealed Radioactive Sources (DSRSs) are stored temporally in the centralized storage facility of Korea Radioactive Waste Agency (KORAD) and planned to be disposed in the low- and intermediate-level radioactive waste (LILW) disposal facility in Gyeongju city. In this study, preliminary post-closure safety assessment was performed for DSRSs in order to draw up an optimum disposal plan. Two types of disposal options were considered, i.e. engineered vault type disposal and rock cavern type disposal which were planned to be constructed and operated respectively in LILW disposal facility in Gyeongju city. Assessment end-point was individual effective dose of critical group and calculated by using GoldSim code. In normal scenario, the maximum dose was estimated to be approximately $1{\times}10^{-7}mSv/yr$ for both disposal options. It meant that both options had sufficient safety margin when compared with regulatory limit (0.1 mSv/yr). Otherwise, in well scenario, the maximum dose exceeded regulatory limit of 1 mSv/yr in engineered vault type disposal and the exposure dose was mainly contributed by $^{226}Ra$, $^{210}Pb$ (daughter nuclide of $^{226}Ra$) and $^{237}Np$ (daughter nuclide of $^{241}Am$). For rock cavern type disposal, even though the peak dose satisfied regulatory limit, the exposure doses by $^{14}C$ and $^{237}Np$ were relatively high above 10% of regulatory limit. Therefore, it is necessary to exclude $^{14}C$, $^{226}Ra$ and $^{241}Am$ for two type of disposal options and additional management such as long-term storage and development of disposal container for those radionuclides should be performed before permanent disposal for conservative safety and security.

Verifying the Classification Accuracy for Korea's Standardized Classification System of Research F&E by using LDA(Linear Discriminant Analysis) (선형판별분석(LDA)기법을 적용한 국가연구시설장비 표준분류체계의 분류 정확도 검증)

  • Joung, Seokin;Sawng, Yeongwha;Jeong, Euhduck
    • Management & Information Systems Review
    • /
    • v.39 no.1
    • /
    • pp.35-57
    • /
    • 2020
  • Recently, research F&E(Facilities and Equipment) have become very important as tools and means to lead the development of science and technology. The government has been continuously expanding investment budgets for R&D and research F&E, and the need for efficient operation and systematic management of research F&E built up nationwide has increased. In December 2010, The government developed and completed a standardized classification system for national research F&E. However, accuracy and trust of information classification are suspected because information is collected by a method in which a user(researcher) directly selects and registers a classification code in NTIS. Therefore, in the study, we analyzed linearly using linear discriminant analysis(LDA) and analysis of variance(ANOVA), to measure the classification accuracy for the standardized classification system(8 major-classes, 54 sub-classes, 410 small-classes) of the national research facilities and equipment established in 2010, and revised in 2015. For the analysis, we collected and used the information data(50,271 cases) cumulatively registered in NTIS(National Science and Technology Service) for the past 10 years. This is the first case of scientifically verifying the standardized classification system of the national research facilities and equipment, which is based on information of similar classification systems and a few expert reviews in the in-outside of the country. As a result of this study, the discriminant accuracy of major-classes organized hierarchically by sub-classes and small-classes was 92.2 %, which was very high. However, in post hoc verification through analysis of variance, the discrimination power of two classes out of eight major-classes was rather low. It is expected that the standardized classification system of the national research facilities and equipment will be improved through this study.

Flexural Test of H-Shape Members Fabricated of High-Strength Steel with Considering Local Buckling (국부좌굴을 고려한 고강도 조립 H형강 부재의 휨성능 실험)

  • Lee, Cheol-Ho;Han, Kyu-Hong;Park, Chang-Hee;Kim, Jin-Ho;Lee, Seung-Eun;Ha, Tae-Hyu
    • Journal of Korean Society of Steel Construction
    • /
    • v.23 no.4
    • /
    • pp.417-428
    • /
    • 2011
  • Depending on the plastic deformation capacity required, structural steel design under the current codes can be classified into three categories: elastic, plastic, and seismic design. Most of the current steel codes explicitly forbid the use of a steel material with a yield strength higher than 450 MPa in the plastic design because of the concerns about its low plastic deformation capacity as well as the lack of test data on local and lateral torsional buckling behavior. In this study, flexural tests on full-scale H-shape members built with SM490A (ordinary steel or benchmark material) and HSB800 (high-strength steel) were carried out. The primary objective was to investigate the appropriateness of extrapolating the local buckling criterion of the current codes, which was originally developed for normal-strength steel, to the case of high-strength steel. All the SM490A specimens performed consistently with the current code criteria and exhibited sufficient strength and ductility. The performance of the HSB800 specimens was also very satisfactory from the strength perspective; even the specimens with a noncompact and slender flange developed the plastic moment capacity. The HSB800 specimens, however, showed an inferior plastic rotation capacity due to the premature tensile fracture of the beam bottom flange beneath the vertical stiffener at the loading point. The plastic rotation capacity that was achieved was less than 3 (or the minimum level required for a plastic design). Although the test results in this study indicate that the extrapolation of the current flange local-buckling criterion to the case of high-strength steel is conservative from the elastic design perspective, further testing together with an associated analytical study is required to identify the causes of the tensile fracture and to establish a flange slenderness criterion that is more appropriate for high-strength steel.

Antigenic localities in the tissued of Metagonimus yokogawai observed by immunogoldlabeling method (면역황금 표식법을 이용한 요꼬가와흡충의 조직내 항원성 부위에 관한 연구)

  • Ahn, Hyuk;Rim, Han-Jong;Kim, Soo-Jin
    • Parasites, Hosts and Diseases
    • /
    • v.29 no.3
    • /
    • pp.245-258
    • /
    • 1991
  • In order to determine the antigenic localization in the tissues of the adult Metagonimus yokegawai, immunogoldlabeling method was applied using serum immunoglobulins (IgG) of cats which were infected with isolated metacercariae from Plecoglossus altivelis. The sectioned worm tissue was embedded in Lowicryl HM 20 medium and stained with infected serum IgG and protein A gold complex (particle size: 12 nm) , It was observed by electron microscopy at each tissue of the worm. The gold particles were observed on the tegumental syncytium as well as cytoplasm of tegumental cells and epithelial lamella of the caecum. The gold particles were not observed on the basal lamina of the tegument, interstitial matrix of the parenchyma, the muscle tissue and mitochondria of the tegument. The gold particles were specifically labeled in the secretory granules in the vitelline cells. They were also labeled on the lumen of bladder and egg shell. The above findings showed that antigenic materials in the tissue of adult worms were specifically concentrated on the tegumental syncytium as well as cytoplasm of tegumental cells and epithelial lamella of the caecum.

  • PDF