• 제목/요약/키워드: Low voltage operation

검색결과 1,030건 처리시간 0.03초

Neutralization을 이용한 주파수 변환기 설계 (Design of Mixer using Neutralization Technique)

  • 최문호;최원호;김영석
    • 한국전기전자재료학회논문지
    • /
    • 제21권4호
    • /
    • pp.311-320
    • /
    • 2008
  • In this paper, a 2.4 GHz low-voltage CMOS double-balanced down-conversion mixer using neutralization technique has been proposed and verified by circuit simulations and measurements. The grounded source structure was used for low-voltage operation. The neutralization technique was used to improve a conversion gain. The proposed mixer is fabricated in $0.25{\mu}m$ CMOS process for a 2.4 GHz wireless receiver. The mixer consumes 1.94 mW and gives conversion gain of 5.66 dB, input IP3 of 0.7 dBm and P1dB of -11.2 dBm at 1.5 V power supply. Measured results for the designed mixer show improved conversion gain of 2.86 dB over conventional mixer of grounded source structure.

Advanced Field Weakening Control for Maximum Output Power Operation of Induction Motor in a Limited Environment

  • Seo, Yong-Joo;Go, Hee-Young;Kim, Jang-Mok
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2012년도 추계학술대회 논문집
    • /
    • pp.217-218
    • /
    • 2012
  • A load motor used for warship or submarine is with limited volume and weight, also specific environmental tests like impact, vibration, noise, temperature and EMC/EMI have to be satisfied. Induction motors, synchronous motors, BLDC motor and etc, are used depending on the purpose of using military equipment. Induction Motors are used for a number of military equipment more commonly due to the robust structure and simple maintenance. Domestic and foreign warships have a wide range of voltages as the DC voltage sources with battery are mainly used for them. The ${\Delta}-connection$ operation of the induction motor is required to make the maximum power in a low voltage level. But the elements' temperature of the inverter increases due to high input current when it is in the ${\Delta}-connection$ operation. Therefore, the induction motor must be driven with the Y-connection. The lack of voltage needs to be with the field weakening control. This paper suggests the optimum field weakening control algorithm to drive the induction motor with maximum power in a limited thermal and DC voltage condition.

  • PDF

전압 불평형에서 콘덴서와 리액터의 직렬 연결시의 콘덴서의 특성 분석 (A Study on Condenser Characteristics at the Series Connection of Condenser and Reactor Under Voltage Unbalance)

  • 김일중;김종겸;박영진;김성헌
    • 전기학회논문지P
    • /
    • 제59권3호
    • /
    • pp.325-329
    • /
    • 2010
  • Capacitor has been used principally for the power factor compensation long ago. However now it does as passive filter to reduce harmonics of nonlinear load with reactor. Most of the customer's low-voltage feeder has been designed with approximately balanced and connected at the 3 phase four wire system. But voltage and current unbalance is appeared by the mixing operation of single or three phase load etc. The addition of reactor at the condenser may rise its terminal voltage. Voltage and current values above rating can act on electrical stress on the condenser. In this paper, we calculated and measured that voltage, current and capacity of condenser are changed under the voltage balance. We conclude that magnitude and deviation of phase voltage act on major point of electrical stress.

Pilot 플라즈마 반응기를 이용한 하수 중 미생물의 불활성화 (Inactivation of Microorganisms in Sewage Using a Pilot Plasma Reactor)

  • 김동석;박영식
    • 한국환경보건학회지
    • /
    • 제39권3호
    • /
    • pp.289-299
    • /
    • 2013
  • Objectives: For the field application of the dielectric barrier discharge plasma reactor, scale-up of the plasma reactor is needed. This study investigated the possibility of inactivation of microorganisms in sewage using pilot multi-plasma reactor. We also considered the possibility of degradation of total organic carbon (TOC) and nonbiodegradable matter ($UV_{254}$) in sewage. Methods: The pilot plasma reactor consists of plasma reactor with three plasma modules (discharge electrode and quartz dielectric tube), liquid-gas mixer, high voltage transformers, gas supply equipment and a liquid circulation system. In order to determine the operating conditions of the pilot plasma reactor, we performed experiments on the operation parameters such as gas and liquid flow rate and electric discharge voltage. Results: The experimental results showed that optimum operation conditions for the pilot plasma reactor in batch experiments were 1 L/min air flow rate), 4 L/min liquid circulation rate, and 13 kV electric discharge voltage, respectively. The main operation factor of the pilot plasma process was the high voltage. In continuous operation of the air plasma process, residual microorganisms, $UV_{254}$ absorbance and TOC removal rate at optimal condition of 13 kV were $10^{2.24}$ CFU/mL, 56.5% and 8.6%, respectively, while in oxygen plasma process at 10 kV, residual microorganisms, $UV_{254}$ absorbance and TOC removal rate at optimal conditions were $10^{1.0}$ CFU/mL, 73.3% and 24.4%, respectively. Electric power was increased exponentially with the increase in high voltage ($R^2$ = 0.9964). Electric power = $0.0492{\times}\exp^{(0.6027{\times}lectric\;discharge\;voltage)}$ Conclusions: Inactivation of microorganisms in sewage effluent using the pilot plasma process was done. The performance of oxygen plasma process was superior to air plasma process. The power consumption of oxygen plasma process was less than that of air plasma process. However, it was considered that the final evaluation of air and oxygen plasma must be evaluated by considering low power consumption, high process performance, operating costs and facility expenses of an oxygen generator.

생물학적 축산폐수 처리수 색도제거를 위한 전기화학적 방법의 적용 (Application of Electrochemical Method for Decolorization of Biologically Treated Animal Wastewater Effluent)

  • 윤성준;신종서;라창식
    • Journal of Animal Science and Technology
    • /
    • 제48권2호
    • /
    • pp.315-324
    • /
    • 2006
  • This research was conducted to clarify the characteristics of electrochemical decolorization of effluent discharged from a biological animal wastewater treatment process and to finally establish parameters or mode for optimum operation of electrolysis system. Average color unit of wastewater was about 1,200 and DSA(Dimensionally Stable Anode) was used as electrode. Experiments were performed with two different operation conditions or modes, fixed voltage-free current(Run A) and free voltage-fixed current(Run B). Color removal rate was proportional to the electrode area and electrical conductivity, and an equation subject to them at a condition of fixed voltage was derived as follows; Ct=C0ekt, k=[{0.0121×a(dm2)× c(mS/cm)}+0.0288], [where, C0: initial color, Ct: color unit after treatment for t, k: reaction coefficient, t: time(min.), a: electrode area, c: conductivity]. From the study on the effects of current density on color removal, it was revealed that the removal efficiency of color was function of the current density, showing direct proportion. However, when considered energy consumption rate, maintenance of low current density was an economical way. Based on the obtained results, it was concluded that supplementation of electrolyte is not necessary for the removal of color from the effluent of secondary treatment process and operation with the mode of free voltage-fixed current, rather than operation with fixed voltage-free current mode, would be an efficient way to increase the removal performance and capacity per consumed energy.

Organic Thin Film Transistors with Gate Dielectrics of Plasma Polymerized Styrene and Vinyl Acetate Thin Films

  • Lim, Jae-Sung;Shin, Paik-Kyun;Lee, Boong-Joo
    • Transactions on Electrical and Electronic Materials
    • /
    • 제16권2호
    • /
    • pp.95-98
    • /
    • 2015
  • Organic polymer dielectric thin films of styrene and vinyl acetate were prepared by the plasma polymerization deposition technique and applied for the fabrication of an organic thin film transistor device. The structural properties of the plasma polymerized thin films were characterized by Fourier-transform infrared spectroscopy, X-ray diffraction, atomic force microscopy, and contact angle measurement. Investigation of the electrical properties of the plasma polymerized thin films was carried out by capacitance-voltage and current-voltage measurements. The organic thin film transistor device with gate dielectric of the plasma polymerized thin film revealed a low operation voltage of −10V and a low threshold voltage of −3V. It was confirmed that plasma polymerized thin films of styrene and vinyl acetate could be applied to functional organic thin film transistor devices as the gate dielectric.

Power Flow Study of Low-Voltage DC Micro-Grid and Control of Energy Storage System in the Grid

  • Kim, Dong-Eok
    • Journal of Electrical Engineering and Technology
    • /
    • 제12권2호
    • /
    • pp.549-558
    • /
    • 2017
  • DC distribution has several differences compared to AC distribution. DC distribution has a higher efficiency than AC distribution when distributing electricity at the same voltage level. Accordingly, power can be transferred further with low-voltage DC. In addition, power flow in a DC grid system is produced by only a voltage difference in magnitude. Owing to these differences, operation of a DC grid system significantly differs from that of an AC system. In this paper, the power flow problem in a bipolar-type DC grid with unbalanced load conditions is organized and solved. Control strategy of energy storage system on a slow time scale with power references obtained by solving an optimization problem regarding the DC grid is then proposed. The proposed strategy is verified with computer simulations.

높은 승압비를 가진 공진형 소프트 스위칭 부스트 컨버터 (A Soft Switching Boost Converter with High Voltage Gain Using a Single Switch)

  • 박건욱;정두용;이수원;정용채;원충연;서광덕
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2009년도 정기총회 및 추계학술대회 논문집
    • /
    • pp.173-175
    • /
    • 2009
  • A dc/dc converter for low voltage of battery application and fuel cell system is required to step up and regulate the low and widely variable voltage. In this paper, we have proposed a soft switching boost converter with high voltage gain using a single switch. Through the theoretical analysis and experimental result, operation modes and characteristics of the proposed topology is verified.

  • PDF

저전압 스트레스를 갖는 AT 포워드 다중 공진형 컨버터 (AT forward MRC with a low voltage stress)

  • 황치면;김희준;김창선;김영태
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 하계학술대회 논문집 F
    • /
    • pp.2042-2044
    • /
    • 1998
  • In this paper, we proposed the alternated forward multi-resonant converter. It can reduce the voltage stress due to the operation of two multi resonant switches and also provides a high frequency applications. The proposed circuit is verified through the PSpice simulation and the 50W experimental set with 2MHz maximum frequency. The measured voltage stress is up to 170V of 2.9 times the input voltage and the efficiency is about 81.66% at low line.

  • PDF

Implementation of PDP Driving Circuit for AC-Type

  • Jang, Yun-Seok;Choi, Jin-Ho
    • Journal of information and communication convergence engineering
    • /
    • 제5권3호
    • /
    • pp.285-288
    • /
    • 2007
  • PDP(Plasma Display Panel) driving circuit requires switching devices and capacitors to stand up high voltages over 150volts. Thereby the power consumption and the cost of a PDP driving circuit increase. In this paper, a PDP driving circuit is proposed that can be operated with a lower supply voltage than the supply voltage of conventional driving circuit. The operation of the proposed driving circuit is verified by the computer simulation and experiments. PSPICE simulation and experiments results show that the output signal can drive PDP cells when the supply voltage is higher than 40volts.