• 제목/요약/키워드: Low voltage cable

검색결과 124건 처리시간 0.026초

RF 수신부를 내장한 GPS 안테나 시스템의 설계 및 제작 (Design and fabrication of the GPS antenna system including RF-stage)

  • 홍성일;이정호;변건식;정만영
    • 전자공학회논문지A
    • /
    • 제33A권6호
    • /
    • pp.99-107
    • /
    • 1996
  • When GPS (global positioning system) is used as synchronous signal in CDMA digital cellular base station system and high speed digital synchronous communication network, antenna cable length is increased, comparing with other GPS application such as positioning or car navigation. In this paper, it is proposed that a type of new GPS antenna system including RF stage for reduction of cable loss in case of long cable.The antenna system with TMPA(truncated-corners microstrip patch antenna) is designed and fabricated because GPS signal has RHCP (right-hand circular polarization), consequently antenna size can be made small size. LNA (low noise amplifier) is designed by using HEMT(high electron mobility transistor)which has lower noise figurae and better AGC characteristics at low voltage than GaAs FET, and we equiped mixer, in GPS antenna unit, which converts from 1575.42MHz to 75.42MHz. As result of comparing between typical system and proposed system when cable length is 60m, 63dB, 55dB and 25dB gain are obtained for RG-316/U, RG-58C/U and RG-213/U, and better characteristics are achieved than typical system as far as cable length is longer.

  • PDF

TFT LCD 검사용 패널링크 디지털 플랫 패널 디스플레이 송신부 구현 (PanelLink Digital Flat Panel Display Transmitter for TFT LCD Test)

  • 이선복;백운성;박창수;홍철호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 추계학술대회 논문집 학회본부 B
    • /
    • pp.621-623
    • /
    • 1998
  • We implemented PanelLlnk digital flat panel display transmitter supporting SXGA($1280{\times}1024$) resolution. It can transmit data through 10m cable at XGA($1024{\times}768$) resolution and through 7m cable at SXGA($1280{\times}1024$). We also found resistor value to get stable display image by low voltage differential signal swing control.

  • PDF

전철 지중배전선로의 충전전류보상에 관한 연구 (A Study of the Charging Current Effect on Underground Distribution Line in Electric Railway)

  • 김양수;장우진
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2008년도 추계학술대회 논문집
    • /
    • pp.214-218
    • /
    • 2008
  • Because on the high-tension underground distribution line of an electric railway high voltage XLPE Cable two or three circuits between railway stations with a standard as receiving transformer facilities are established at a $30km{\sim}50km$ interval, reactive power in which the phase of a current is larger than that of a voltage is supplied when trains are not working, so when there are no loading or low loading as night. Due to the long-distance trend of the underground distribution system on an alternating current railway distribution line, the terminal voltage of a transformer is over the standard voltage, and after all, commercial cycle overvoltage is continued. To solve this problem, the shunt reactor is installed in middle of power distribution lines to maintain receiver voltage meted under the allowance regulation through control of the reactive power. Also, in case that the thickness of single cable is over $60mm^2$ and length of line is about over 30km, a circuit breaker is broken by shorting shunt ability of charging current in excess of shunt current(31.5A.rms). Therefore, this thesis presents installing the location of shunt reactor for quantitative analysis by using optimum algorism for compensation and control of the charging current.

  • PDF

고온초전도 케이블의 절연설계를 위한 적층효과 (Multi-layered Effect for the Insulation Design of a HTS Cable)

  • 곽동순;천현권;김해종;조전욱;정순용;김상현
    • 한국전기전자재료학회논문지
    • /
    • 제18권10호
    • /
    • pp.950-955
    • /
    • 2005
  • For the insulation design of a high temperature superconducting(HTS) cable, three kinds of design method were proposed, which used AC and impulse withstand voltage and partial discharge inception strength. However, the designed insulation thickness by AC and impulse could not be applied to cable fabrication process due to much low electrical breakdown strength. The effect of the multi-layered insulation paper was not considered on the previous insulation design and the insulation thickness by partial discharge inception strength could be applied only. In this paper, the electrical breakdown characteristic, which considered the effect of multi-layered of LPP, was investigated to design the insulation thickness.

고발포 동축케이블에 있어서 감쇄량특성 과 전파속도 (The Properties of Attenuation and Propagation Velocity in the High Foamed Coaxial Cable)

  • 유선규;이창훈;박대희
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 하계학술대회 논문집 D
    • /
    • pp.1484-1486
    • /
    • 1998
  • Recently, extending the local broadcasting and increasing lots of informations, the low-loss communication cable is required in proportion as frequency. The reason of transportation loss causes to using the high frequencies like hundreds of MHz or decades of GHz. For the low transportation loss, it is required the developing-technology of foaming and the high foamed insulator with the dielectric ratio of the nearest to 1. Therefore, there is the purpose of developing the insulating materials for the low dielectric ratio. Also it is important to measure the attenuation, which is one of the important parameters, as the evaluation of transportation characteristic with frequency in the communication cable. In this paper, the result showed that the dielectric ratio(1.4) of the nearest to 1 and low attenuation with high frequency were very related to the transportation and reflection characteristics such as propagation velocity(82.27%), delay time and voltage standing wave ratio(VSWR).

  • PDF

고온 초전도 케이블의 퀜치 보호를 위한 검출기 설계 (Design of quench detector for protection of HTS cable)

  • 최용선;황시돌;임성우;최효상;현옥배
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 하계학술대회 논문집 B
    • /
    • pp.958-960
    • /
    • 2002
  • High Temperature Superconducting (HTS) devices make it possible to operate with no electrical loss by resistance. If, however, the applied current is over its critical current, the phase of HTS devices is changed to normal state, so called, quench. In this case, since resistance of HTS is increased abruptly, it can not be avoidable to damage the whole apparatus. In this study, quench detector to protect HTS devices was proposed. We designed the quench detecting circuit and tested the performance of the circuit. The detecting circuit was consisted of Op-Amp and low pass filter etc, to detect very low voltage around $1{\mu}V$. The circuit detected effectively the low voltage when over current is applied to HTS tapes. At the next step, we are going to apply and test the circuit to protect the prototype HTS cable.

  • PDF

초전도 케이블용 BSCCO의 사고각에 따른 통전특성 분석 (The Analysis of The Transport Current Property Depend on The Fault Angle of BSCCO HTS Cable)

  • 이동혁;두호익;두승규;김민주;김용진;한병성
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2009년도 하계학술대회 논문집
    • /
    • pp.367-368
    • /
    • 2009
  • BSCCO HTS(High Temperature Superconductor) could be applied to superconducting cable, magnet and motor, using its hight critical properties. Especially, superconducting cable has a hight possibility of practical use due to the possibility of low voltage and high capacity transmission caused by its lower power loss than copper cable. In this paper, the transport characteristics of BSCCO superconducting cable, according to the change of BSCCO superconducting cable's accident point at phase $0^{\circ}$ and $45^{\circ}C$, were analyzed and compared each other. Consequently, when the accident was occur the resistance of the HTS was higher at the point phase $0^{\circ}$ than $45^{\circ}$ which means it will cause much higher load on the HTS.

  • PDF

예인 음탐기용 케이블 개발 (Development of Cable for Towed Array Sonar System)

  • 양승윤;김정석;김철민;이진희
    • 한국군사과학기술학회지
    • /
    • 제19권5호
    • /
    • pp.559-566
    • /
    • 2016
  • Cables for Towed Array Sonar System(TASS) were developed. In order to verify the performance of cables, environmental and operational conditions as well as functional requirements were investigated during design stage. Double armored high and low voltage integrated cable for towed body and two kinds of cables, armored and light weight power and optic hybrid cables for towed array sensor system were developed by modeling and simulation. Customized manufacturing process and test method, such as foam extrusion and dynamic fatigue test were applied to this development. In conclusion, underwater towed hybrid cable with high tensile strength and compact structure were developed.

적외선 센서를 이용한 열화상태 무선감시 시스템 개발 (A Development of Wireless Monitoring System for Temperature Monitoring by using IR Sensor)

  • 김지희;김신우;강용수
    • 전자공학회논문지
    • /
    • 제50권1호
    • /
    • pp.239-245
    • /
    • 2013
  • 발전소 내 고압 단자대 및 전력구 케이블 인입부에서 주변 전력기기들의 지속적인 진동 및 순간적인 충격의 발생으로 케이블 단자 또는 접속부 접촉점에 열화가 발생하는 사고가 일어난다. 접촉점에서의 열화 발생은 큰 사고로 이어질 수 있으며 안정적으로 전력을 공급해야 하는 발전소에서는 열화 발생을 예측하기 위한 다양한 연구가 시도되고 있다. 이에 비접촉식 적외선 센서를 이용하여 온도를 측정하는 방식이 있으며 이러한 방식의 궁극적인 목적은 측정하고자 하는 대상체를 최적의 거리에서 감시함으로 접촉점의 열화 발생뿐 아니라 센서 측정범위 내의 열화의 상태도 감시하는 데 있다. 연결부 온도를 측정하고 열화 상태를 실시간 감시하여 사용자에게 가시, 가청 알람을 주어 사용자가 열화사고를 인지하여 미연에 방지할 수 있게 한다. 그러나 이러한 시스템을 구축하기 위해서는 감시 장치를 설치, 운영해야 하는 어려움이 있다. 본 연구에서는 설치 용이성을 고려하여 소출력 배터리 동작모듈로 접속부의 온도를 측정하고 이를 감시할 수 있는 적외선센서를 이용한 무선감시시스템을 개발하였다.

저압케이블용 절연재료의 OIT 특성분석 (Characterization of Insulation Materials of Oxide Induced Time for Low Voltage Cables with $\tau$-Ray Irradiation)

  • 박정기;이우선;한재홍;서용진;김남오;김형곤
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2001년도 춘계학술대회 논문집 반도체재료
    • /
    • pp.57-60
    • /
    • 2001
  • This study describes the effect of $\tau$ -ray irradiation on the properties of insulation materials for low voltage cables in a nuclear power plant. The radiation effects were characterized by measuring OIT, FTIR, electrical properties of the irradiated specimens. As a result, they showed the decrease of OIT and the increase of chemical structural defects with the increase of $\tau$ -ray amount

  • PDF