방사선조사에 따른 원전 저압케이블용 절연재료의 특성분석 (Characterization of Insulation Materials for Low Voltage Cables in a Nuclear Power Plant with ${\gamma}$-Ray Irradiation)

  • 박정기;이우선;한재홍
    • 한국전기전자재료학회논문지
    • /
    • 제14권5호
    • /
    • pp.397-404
    • /
    • 2001
  • This study describes the effect of γ-ray irradiation on the properties of insulation materials for low voltage cables in a nuclear power plant. The radiation effects were characterized by measuring OIT, FTIR, electrical properties of the irradiated specimens. As a result, they showed the decrease of OIT and the increase of chemical structural defects with the increase of γ-ray amount. Also, the electrical properties such as dielectrical constant, tan $\delta$ and current were changed by aging. These changes may come from the increase of chemical structural defects by $\delta$-ray irradiation.

  • PDF

인버터 스위칭전압 파형에 의한 전동기 권선 영향 해석 (Analysis of Motor Winding impact by inverter Switching Voltage Waveforms)

  • 김종겸
    • 조명전기설비학회논문지
    • /
    • 제13권1호
    • /
    • pp.94-101
    • /
    • 1999
  • 본 논문은 PWM인버터 장치의 스위칭 서지에 관한 문제를 분석한 것이다. 교류 전동기의 효율적인 속도제어를 위한 가변속 구동 장치의 적용이 증가함에 따라 전동기와 가변속 구동장치에 관련된 고장이 발생한다. 산업용 전동기 설비에 PWM 드라이브의 도입은 때때로 높은 과도전압 피크에 의한 상권선 사이 절연파괴를 낳을 수 있다. 높은 스위칭 주파수와 결합한 전동기 케이블 길이는 적?한 드라이브 동작을 위한 매우 민감한 문제가 된다. 케이블 길이와 높은 스위칭주파수의 결과는 전동기와 인버터에 영향을 미칠 수 있다. 전동기 권선 절연레벨이 낮을 때, 높은 피크전압과 빠른 전압상승시간에 의해 생겨난 고장 확률은 높다. 전압반사는 전동기 용량, 여러 가변속 구동장치와 상승시간에 대해 계산하였으며 이를 도식적으로 나타내었다. 인버터 구동 교류 전동기 시스템에서 전동기 단자 과전압과 전압상승률을 줄이기 위한 필터효과도 언급하였다. 연구결과 전동기 용량과 전동기 절연정격 레벨이 낮을수록 그리고 스위칭 시간과 케이블 길이가 짧을수록 절연파괴의 가능성이 높아짐을 알 수 있었다.

  • PDF

22.9kV 초전도케이블 시스템의 신뢰성 평가 (Reliability Assesment of 22.9kV High Temperature Superconducting Cable System)

  • 손송호;임지현;성태현;류희석;양형석;김동락;황시돌
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2007년도 하계학술대회 논문집 Vol.8
    • /
    • pp.248-248
    • /
    • 2007
  • Demands for electricity are growing, whereas the rate of electricity infrastructure's construction declines gradually. To keep the balance of the demand and supply, the share of underground transmission line will be increased from 8.3% to 10.5% in 2020 but it will be accompanied with enormous public expenses. A great concern in high capacity transmission is on the increase so as to maximize the spacial efficiency. High Temperature Superconducting (HTS) cable is in the lime light which has the merits of environment-friendly, low transmission loss and high transmission with low voltage, but the reliability verification as a power system is yet to be solved. KEPCO completed the installation and acceptance of $3{\phi}$, 22.9kV, 1250A class HTS cable system in 2006 and the long term test is in progress. The test results focusing on long term reliability are presented in this paper.

  • PDF

Analysis on the Switching Surge Characteristics of a High-Voltage Induction Motor Fed by PWM Inverter Using EMTP

  • Kim Jae-Chul;Song Seung-Yeop;Lee Do-Hoon
    • KIEE International Transactions on Power Engineering
    • /
    • 제5A권1호
    • /
    • pp.22-30
    • /
    • 2005
  • The PWM inverter drive may cause an over voltage at the motor terminal, which imposes severe electric stresses on the inter-turn insulation of motor windings. Unlike low-voltage induction motors, high-voltage induction motors have a stator type of form-wound coil for insulation and are insulated to the slot and the coil. So, this paper presents a PWM 3-level inverter, H-Bridge cascaded 7-level inverter and High-voltage induction motor model. It then analyzes the voltage that generates at the input terminal of the high-voltage induction motor fed by each inverter. Also, in order to examine a factor that influences the switching surge voltage, this paper proposes the system equivalent model and performs the case studies using EMTP.

A Decentralized Optimal Load Current Sharing Method for Power Line Loss Minimization in MT-HVDC Systems

  • Liu, Yiqi;Song, Wenlong;Li, Ningning;Bai, Linquan;Ji, Yanchao
    • Journal of Power Electronics
    • /
    • 제16권6호
    • /
    • pp.2315-2326
    • /
    • 2016
  • This paper discusses the elimination of DC voltage deviation and the enhancement of load current sharing accuracy in multi-terminal high voltage direct current (MT-HVDC) systems. In order to minimize the power line losses in different parallel network topologies and to insure the stable operation of systems, a decentralized control method based on a modified droop control is presented in this paper. Averaging the DC output voltage and averaging the output current of two neighboring converters are employed to reduce the congestion of the communication network in a control system, and the decentralized control method is implemented. By minimizing the power loss of the cable, the optimal load current sharing proportion is derived in order to achieve rational current sharing among different converters. The validity of the proposed method using a low bandwidth communication (LBC) network for different topologies is verified. The influence of the parameters of the power cable on the control system stability is analyzed in detail. Finally, transient response simulations and experiments are performed to demonstrate the feasibility of the proposed control strategy for a MT-HVDC system.

뇌격전류 측정의 정확도에 영향을 미치는 요인 (Factors Affected the Accuracy of Lightning Current Measuring System)

  • 이복희;장근철;강성만;엄주홍;정길조;심응보;우정욱
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 하계학술대회 논문집 C
    • /
    • pp.1674-1676
    • /
    • 2003
  • The factors affecting the accuracy of lightning current measuring system are figured out the materials and length of down-conductor, and impedance matching between grounding resistance and characteristic impedance of cable. The cable with the low characteristic impedance used to transfer the lightning current from the top of the tower is too long to measure the waveform of lightning current, exactly. Especially, the height of the tower can cause the change of front time and magnitude of lightning stroke current. Basically, in this experiment. It was found that the magnitude and rise time of the lightning current are extremely dependant in the length of down-conductor in lightning current measuring system.

  • PDF

전력케이블 진단을 위한 부분방전 검출장치의 설계 및 제작 (Design and Fabrication of a PD Detector for Power Cable Diagnosis)

  • 송재용;서황동;길경석;한문섭;장동욱
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2005년도 추계학술대회 논문집
    • /
    • pp.777-782
    • /
    • 2005
  • In this paper, we designed and fabricated a partial discharge (PD) detector to diagnose the soundness of CNCV cables by analyzing PD pulses and to predict discharge locations. The PD detector is consisted of a coupling network with a discharge free capacitor and a detection impedance, a voltage follower and a low noise amplifier. Lower cut-off frequency of the detector is adjusted at 175kHz to block AC voltage and to pass discharge pulse only. The discharge location could be obtained by the time of arrival method using travelling wave propagation theory. In a laboratory test on an eighty meter CV cable, we could position the discharge location within a two meter error.

  • PDF

멀티레벨 인버터 구동 고압유도전동기에서 발생하는 과도과전압 저감을 위한 RC필터의 효과분석 (Analysis on the effect of RC filter to mitigate transient overvoltage on the high voltage induction motor fed by Multi level inverter)

  • 권영목;김재철;김용성;이양진
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2005년도 학술대회 논문집
    • /
    • pp.399-403
    • /
    • 2005
  • In this paper, we analyze on the effect of RC filter to mitigate transient overvoltage on the high voltage induction motor fed by H-bridge cascaded 7-level inverter. The switching surge voltage becomes the major cause to occur the insulation failure by serious voltage stress in the stator winding of high voltage induction motor. The effect of switching surge appears more serious in high voltage induction motor than low voltage induction motor. Consequently, we demonstrated that the RC filter connected to the motor terminals greatly reduces the transient voltage stress md ringing. The results of simulation show the suppression of transient overvoltage at the motor end of a long cable. using EMTP

  • PDF

저압 간선의 설계기법에 관한 연구 (A Study on the Designed Method of Low Voltage Feeder)

  • 조계술;고만석;신강욱;원진희;최홍규
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2001년도 학술대회논문집
    • /
    • pp.167-172
    • /
    • 2001
  • 본 연구는 저압간선의 굵기 산정에 있어서 체계적인 설계 흐름도를 분석하였고 Cable size별로 온도변화에 따른 직류 저항값 대비 교류 임피던스값의 변화에 대하여 전압강하를 고려한 간선의 선정기법을 제시 하였다.

  • PDF

지상파 및 케이블 디지털 TV 튜너를 위한 RF 프런트 엔드 (An RF Front-end for Terrestrial and Cable Digital TV Tuners)

  • 최치훈;임동구;남일구
    • 전자공학회논문지
    • /
    • 제49권12호
    • /
    • pp.242-246
    • /
    • 2012
  • 본 논문에서는 지상파 및 케이블 디지털 TV를 위한 더블 컨버전 (double-conversion) zero-IF 튜너에 적합한 저잡음 고선형 광대역 RF 프런트 엔드를 제안한다. 저잡음 증폭기는 전류 증폭 기반의 잡음 제거 기법을 적용하여 저잡음과 고선형성 특성을 갖는다. 상향 변환 믹서와 SAW 필터 버퍼는 3차 intermodulation 제거 기법을 적용하여 고선형성 특성을 갖는다. 제안한 RF 프런트 엔드는 $0.18{\mu}m$ CMOS 공정을 사용하여 설계하였고, 전원 전압 1.8 V에서 60 mA의 전류를 소모하면서 48 MHz에서 862Hz의 디지털 TV 밴드에서 30 dB의 전압 이득, 4.2 dB의 single side-band 잡음 지수, 40 dBm의 IIP2, -4.5 dBm의 IIP3의 성능을 보인다.