• Title/Summary/Keyword: Low voltage cable

Search Result 124, Processing Time 0.029 seconds

Design and fabrication of the GPS antenna system including RF-stage (RF 수신부를 내장한 GPS 안테나 시스템의 설계 및 제작)

  • 홍성일;이정호;변건식;정만영
    • Journal of the Korean Institute of Telematics and Electronics A
    • /
    • v.33A no.6
    • /
    • pp.99-107
    • /
    • 1996
  • When GPS (global positioning system) is used as synchronous signal in CDMA digital cellular base station system and high speed digital synchronous communication network, antenna cable length is increased, comparing with other GPS application such as positioning or car navigation. In this paper, it is proposed that a type of new GPS antenna system including RF stage for reduction of cable loss in case of long cable.The antenna system with TMPA(truncated-corners microstrip patch antenna) is designed and fabricated because GPS signal has RHCP (right-hand circular polarization), consequently antenna size can be made small size. LNA (low noise amplifier) is designed by using HEMT(high electron mobility transistor)which has lower noise figurae and better AGC characteristics at low voltage than GaAs FET, and we equiped mixer, in GPS antenna unit, which converts from 1575.42MHz to 75.42MHz. As result of comparing between typical system and proposed system when cable length is 60m, 63dB, 55dB and 25dB gain are obtained for RG-316/U, RG-58C/U and RG-213/U, and better characteristics are achieved than typical system as far as cable length is longer.

  • PDF

PanelLink Digital Flat Panel Display Transmitter for TFT LCD Test (TFT LCD 검사용 패널링크 디지털 플랫 패널 디스플레이 송신부 구현)

  • Lee, Seon-Bok;Baek, Woon-Sung;Park, Chang-Soo;Hong, Cheol-Ho
    • Proceedings of the KIEE Conference
    • /
    • 1998.11b
    • /
    • pp.621-623
    • /
    • 1998
  • We implemented PanelLlnk digital flat panel display transmitter supporting SXGA($1280{\times}1024$) resolution. It can transmit data through 10m cable at XGA($1024{\times}768$) resolution and through 7m cable at SXGA($1280{\times}1024$). We also found resistor value to get stable display image by low voltage differential signal swing control.

  • PDF

A Study of the Charging Current Effect on Underground Distribution Line in Electric Railway (전철 지중배전선로의 충전전류보상에 관한 연구)

  • Kim, Yang-Su;Jang, Woo-Jin
    • Proceedings of the KSR Conference
    • /
    • 2008.11b
    • /
    • pp.214-218
    • /
    • 2008
  • Because on the high-tension underground distribution line of an electric railway high voltage XLPE Cable two or three circuits between railway stations with a standard as receiving transformer facilities are established at a $30km{\sim}50km$ interval, reactive power in which the phase of a current is larger than that of a voltage is supplied when trains are not working, so when there are no loading or low loading as night. Due to the long-distance trend of the underground distribution system on an alternating current railway distribution line, the terminal voltage of a transformer is over the standard voltage, and after all, commercial cycle overvoltage is continued. To solve this problem, the shunt reactor is installed in middle of power distribution lines to maintain receiver voltage meted under the allowance regulation through control of the reactive power. Also, in case that the thickness of single cable is over $60mm^2$ and length of line is about over 30km, a circuit breaker is broken by shorting shunt ability of charging current in excess of shunt current(31.5A.rms). Therefore, this thesis presents installing the location of shunt reactor for quantitative analysis by using optimum algorism for compensation and control of the charging current.

  • PDF

Multi-layered Effect for the Insulation Design of a HTS Cable (고온초전도 케이블의 절연설계를 위한 적층효과)

  • Kwag, Dong-Soon;Cheon, Hyeon-Gweon;Kim, Hae-Jong;Cho, Jeon-Wook;Chung, Soon-Yong;Kim, Sang-Hyun
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.18 no.10
    • /
    • pp.950-955
    • /
    • 2005
  • For the insulation design of a high temperature superconducting(HTS) cable, three kinds of design method were proposed, which used AC and impulse withstand voltage and partial discharge inception strength. However, the designed insulation thickness by AC and impulse could not be applied to cable fabrication process due to much low electrical breakdown strength. The effect of the multi-layered insulation paper was not considered on the previous insulation design and the insulation thickness by partial discharge inception strength could be applied only. In this paper, the electrical breakdown characteristic, which considered the effect of multi-layered of LPP, was investigated to design the insulation thickness.

The Properties of Attenuation and Propagation Velocity in the High Foamed Coaxial Cable (고발포 동축케이블에 있어서 감쇄량특성 과 전파속도)

  • Yu, Seon-Kyu;Lee, Chang-Hun;Park, Dae-Hee
    • Proceedings of the KIEE Conference
    • /
    • 1998.07d
    • /
    • pp.1484-1486
    • /
    • 1998
  • Recently, extending the local broadcasting and increasing lots of informations, the low-loss communication cable is required in proportion as frequency. The reason of transportation loss causes to using the high frequencies like hundreds of MHz or decades of GHz. For the low transportation loss, it is required the developing-technology of foaming and the high foamed insulator with the dielectric ratio of the nearest to 1. Therefore, there is the purpose of developing the insulating materials for the low dielectric ratio. Also it is important to measure the attenuation, which is one of the important parameters, as the evaluation of transportation characteristic with frequency in the communication cable. In this paper, the result showed that the dielectric ratio(1.4) of the nearest to 1 and low attenuation with high frequency were very related to the transportation and reflection characteristics such as propagation velocity(82.27%), delay time and voltage standing wave ratio(VSWR).

  • PDF

Design of quench detector for protection of HTS cable (고온 초전도 케이블의 퀜치 보호를 위한 검출기 설계)

  • Choi, Yong-Sun;Hwang, Si-Dole;Yim, Seong-Woo;Choi, Hyo-Sang;Hyun, Ok-Bea
    • Proceedings of the KIEE Conference
    • /
    • 2002.07b
    • /
    • pp.958-960
    • /
    • 2002
  • High Temperature Superconducting (HTS) devices make it possible to operate with no electrical loss by resistance. If, however, the applied current is over its critical current, the phase of HTS devices is changed to normal state, so called, quench. In this case, since resistance of HTS is increased abruptly, it can not be avoidable to damage the whole apparatus. In this study, quench detector to protect HTS devices was proposed. We designed the quench detecting circuit and tested the performance of the circuit. The detecting circuit was consisted of Op-Amp and low pass filter etc, to detect very low voltage around $1{\mu}V$. The circuit detected effectively the low voltage when over current is applied to HTS tapes. At the next step, we are going to apply and test the circuit to protect the prototype HTS cable.

  • PDF

The Analysis of The Transport Current Property Depend on The Fault Angle of BSCCO HTS Cable (초전도 케이블용 BSCCO의 사고각에 따른 통전특성 분석)

  • Lee, Dong-Hyeok;Du, Ho-Ik;Doo, Seung-Gyu;Kim, Min-Ju;Kim, Yong-Jin;Han, Byoung-Sung
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2009.06a
    • /
    • pp.367-368
    • /
    • 2009
  • BSCCO HTS(High Temperature Superconductor) could be applied to superconducting cable, magnet and motor, using its hight critical properties. Especially, superconducting cable has a hight possibility of practical use due to the possibility of low voltage and high capacity transmission caused by its lower power loss than copper cable. In this paper, the transport characteristics of BSCCO superconducting cable, according to the change of BSCCO superconducting cable's accident point at phase $0^{\circ}$ and $45^{\circ}C$, were analyzed and compared each other. Consequently, when the accident was occur the resistance of the HTS was higher at the point phase $0^{\circ}$ than $45^{\circ}$ which means it will cause much higher load on the HTS.

  • PDF

Development of Cable for Towed Array Sonar System (예인 음탐기용 케이블 개발)

  • Yang, Seung-Yun;Kim, Jung-Suk;Kim, Chul-Min;Lee, Jin-Hee
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.19 no.5
    • /
    • pp.559-566
    • /
    • 2016
  • Cables for Towed Array Sonar System(TASS) were developed. In order to verify the performance of cables, environmental and operational conditions as well as functional requirements were investigated during design stage. Double armored high and low voltage integrated cable for towed body and two kinds of cables, armored and light weight power and optic hybrid cables for towed array sensor system were developed by modeling and simulation. Customized manufacturing process and test method, such as foam extrusion and dynamic fatigue test were applied to this development. In conclusion, underwater towed hybrid cable with high tensile strength and compact structure were developed.

A Development of Wireless Monitoring System for Temperature Monitoring by using IR Sensor (적외선 센서를 이용한 열화상태 무선감시 시스템 개발)

  • Kim, Jihee;Kim, Sinwoo;Kang, Yongsoo
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.50 no.1
    • /
    • pp.239-245
    • /
    • 2013
  • The temperature monitoring of power cable and cable junction point is the necessary link of the safe and reliable operation of the power system. Many kinds of cables and high voltage junction points are easy to exposed continuous vibrations and momentary impulse in industry field especially power plant industries. This system can predict the overheating of the electric cable interface and the possibility of all kinds of accident, and it helps for eliminating the hazards of electric cable interface and provides the effective guarantee for the safety operation. In order to avoid the faults of the inconvenience of installation and maintenance and the high cost of application, this system used small and contactless IR sensor module. The low power consumption is used in the system. The goal of this study is the low cost and on-line reliable monitoring of power cable and junction point temperature.

Characterization of Insulation Materials of Oxide Induced Time for Low Voltage Cables with $\tau$-Ray Irradiation (저압케이블용 절연재료의 OIT 특성분석)

  • Park, Jeong-Ki;Lee, Woo-Sun;Lee, Jae Hong;Seo, Yong-Jin;Kim, Nam-Oh;Kim, Hyung-Gon
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2001.05b
    • /
    • pp.57-60
    • /
    • 2001
  • This study describes the effect of $\tau$ -ray irradiation on the properties of insulation materials for low voltage cables in a nuclear power plant. The radiation effects were characterized by measuring OIT, FTIR, electrical properties of the irradiated specimens. As a result, they showed the decrease of OIT and the increase of chemical structural defects with the increase of $\tau$ -ray amount

  • PDF