• Title/Summary/Keyword: Low voltage DSP

Search Result 98, Processing Time 0.035 seconds

Development of the 300kVA Large Capacity IGBT UPS (IGBT를 적용한 300kVA급 대용량 무정전전원장치 개발)

  • Byun, Y.B.;Kim, T.J.;Joe, K.Y.;Park, S.J.;Kim, C.U.
    • Proceedings of the KIEE Conference
    • /
    • 1998.07f
    • /
    • pp.2057-2059
    • /
    • 1998
  • In order to maintain a high quality output voltage, conventional UPS systems use complex filters with large passive components. To overcome this drawback, real time feedback control schemes have been invested. However, these techniques require a high inverter switching frequency to dynamically adapt to changing load conditions reduce harmonics of the output voltage, thereby rendering the system inadequate for high power applications. This paper presents real time digital signal processor(DSP) control of a large capacity UPS system feeding nonlinear loads to provide a sinusoidal inverter output voltage, unity input power factor, low bus voltage ripple, and excellent transient response.

  • PDF

Comparison of Multilevel Inverters Employing DC Voltage Sources Scaled in the Power of Three

  • Hyun, Seok-Hwan;Kwon, Cheol-Soon;Kim, Kwang-Soo;Kang, Feel-Soon
    • Journal of international Conference on Electrical Machines and Systems
    • /
    • v.1 no.4
    • /
    • pp.457-463
    • /
    • 2012
  • Cascaded H-bridge multilevel inverters shows a useful circuit configuration to increase the number of output voltage levels to obtain high quality output voltage. By applying the concept of the power of three to dc voltage sources, it can increase the number of output voltage levels effectively. To realize this concept, two approaches may be considered. One is to use independent dc voltage sources pre-scaled in the power of three, and the other is to use instantaneous dc voltage sources generated from a cascaded transformer, which has the secondary turn-ratios scaled in the power of three in sequence. A common feature in both approaches is to use the concept of the power of three for dc voltage sources, and a point of difference is whether it adopts a low frequency transformer or not, and where the transformer is located. According to the difference, application areas are limited and show different characteristics on THD of output voltages. We compare and analyze both approaches for their circuit configurations, voltage level generating method, THD characteristics of output voltage, efficiency, application areas, limitations, and other characteristics by experiments using 500 [W] prototypes when they generate a 27-level output voltage.

Current to Voltage Converter for Low power OFDM modem (저전력 OFDM 모뎀 구현을 위한 IVC설계)

  • Kim, Seong-Kweon
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.3 no.2
    • /
    • pp.86-92
    • /
    • 2008
  • Othogonal Frequency Division Multiplexing(OFDM) has been taken notice of 4th generation communication method because it has a merit of high data rate(HDR). To realize HDR communication, The OFDM a s high efficient Fast-Fourier-Transform (FFT)/Inversion FFT (IFFT) processor. Currently OFDM is realized by Digital Signal Processor(DSP) but it consumes a lot of Power. Therefore, current-mode FFT LSI has been proposed for compensation of this demerit. In this paper, we propose IVC for current-mode FFT LSI. From the simulation result, the output value of IVC is more than 3V when the value of FFT Block output is more than $7.35{\mu}A$. The output value of IVC is lower than 0.5V when the value of FFT Block output is lower than $0.97{\mu}A$. Designed IVC Low-power Current mode FFT LSI will contribute to the operation of current-mode FFT LSI and the development of next generation wireless communication systems.

  • PDF

A Study on the High Performance PWM Technique for a Propulsion System of Railway (철도차량용 추진제어장치의 고능률 PWM기법에 관한 연구)

  • Min, Byoung-Gwon;Seo, Kwang-Duk;Won, Chung-Yuen
    • Journal of the Korean Institute of Telematics and Electronics S
    • /
    • v.35S no.10
    • /
    • pp.186-192
    • /
    • 1998
  • This paper presents a high performance low switching PWM technique or the propulsion system of railway such as subway and high speed train. In order to achieve the continuous voltage control to six-step and s low harmonics with low switching frequency under 500Hz, the synchronous technique is combined with a space vector overmodulation and implemented by using DSP. Improved performance and a validation of proposed method are showed by the digital simulation and the experimental results using a 1.65MVA IGBT VVVF inverter and inertia load equivalent to 160 tons railway cars.

  • PDF

Compensation of low Frequency Resonance in Current Driven Loudspeakers using DSP (DSP를 이용한 전류구동 스피커의 저주파 공진 보상)

  • Park, Jong-phil;Eun, Changsoo
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2021.05a
    • /
    • pp.584-588
    • /
    • 2021
  • The impedance of the speaker is likely to be recognized as a fixed value. However, speaker impedance continues to vary with frequency variation, especially larger in resonant frequency region. The sound pressure level of loudspeakers is determined by the current flowing throughout the coil that consists loudspeakers. If loudspeakers are driven by voltage, sound pressure level of the loudspeaker is distorted by the variation of loudspeaker impedance. Current-drive of loudspeakers can solve this problem, but distortion of sound pressure level occurs in low frequencies due to resonance. The distortion can degrade the sound quality of the sound system. So to solve this problem, In this paper, we propose a resonance compensation circuit using DSP. we simulates audio systems using an equivalent model of loudspeakers to verify distortion of sound pressure level due to impedance variation and propose a circuit to compensate it. The proposed circuit is configured using a state variable filter and it can adjust the center frequency and output, so it will be used various sound systems.

  • PDF

Development of the Surge Measurement System for Low Voltage Power Line of Industrial Plants (산업플랜트용 서지 측정 분석 장치 개발)

  • Kim, Y.J.;Kim, J.H.;Chang, S.H.
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.1698-1699
    • /
    • 2007
  • This paper deals with the surge measurement system for low voltage power line of industrial plants. It consists of a capacitive divider, A/D conversion part, signal processing and control part. A FPGA and a DSP board were designed to fast signal processing and control. Also, in order to measure lightning surge and switching surge for a long time, data backup device was applied by using SD memory. A performance of the measurement system was verified through evaluation test using impulse calibration generator.

  • PDF

Advanced Field Weakening Control for Maximum Output Power Operation of Seawater Cooling Pump Induction Motor in a Limited Environment (제한된 환경에서의 해수냉각펌프용 유도전동기 최대출력 운전을 위한 약계자 제어)

  • Son, Yung-Deug;Seo, Yong-Joo;Jung, Jun-Hyung;Kim, Jang-Mok
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.18 no.6
    • /
    • pp.540-546
    • /
    • 2013
  • The induction motor is used for driving the special equipments such as warship and submarine pump due to robust structure and simple maintenance. Domestic and foreign warships use a wide range of voltages and the DC voltage sources mainly from battery. In the low voltage level, the ${\Delta}$-connection operation of induction motor can be used for the maximum power. However, the temperature of the inverter increases because of the high input current. On the other hand, Y-connection operation of the induction motor does not cause a problem of temperature because of the low input current compared to the ${\Delta}$-connection. But the lack of the supply voltage can not be avoided. Therefore, this paper suggests the algorithm of the optimum field weakening control to extend the operating range of the induction motor with maximum power in a limited thermal and DC voltage condition.

A Design of Full-Digitalized IM Controller Using Sliding Mode Control Algorithm (슬라이딩 모드 제어기법을 이용한 유도 전동기의 완전 디지털 제어기 설계)

  • Kang, M.H.;Kim, N.J.;Yoo, J.Y.;Park, G.T.
    • Proceedings of the KIEE Conference
    • /
    • 1994.07a
    • /
    • pp.360-362
    • /
    • 1994
  • This paper presents a design and implementation of DSP-based full-digitalized sliding mode controller(SMC) for an induction motor(IM) fed by voltage source inverter(VSI) with intelligent power module(IPM). By using SMC with load torque observer, we can obtain improved control performances, i.e., robustness, high precision and low chattering. Furthermore, this paper emploies space vector modulation (SVM) method which is implemented to minimize hard ware configuration and to obtain modulation flexibility along with only DSP software operation.

  • PDF

A fully digitized Vector Control of PMSM using 80296SA (80296SA를 이용한 영구자석 동기전동기 벡터제어의 완전 디지털화)

  • 안영식;배정용;이홍희
    • Proceedings of the KIPE Conference
    • /
    • 1998.11a
    • /
    • pp.5-8
    • /
    • 1998
  • The adaptation to vector control theory is so generalized that it is widely used for implementing the high-performance of AC machine. Nowadays, One-Chip microprocessors or DSP chips are being well-used to implement Vector Control algorithm. DSP Chip have less flexibility for memory decoding and I/O rather than One-Chip microprocessor so that is requires more additional circuit and high cost. And the past One-Chip micro processors have difficult of implementation the complex algorithm because of small memory capacity and low arithmetic performance. Therefore we implemented the vector control algorithm of PMSM(Permanent Magnetic Synchronous Motors) using 80296SA form intel , which have many features as 6M memory space, 500MHz clock frequency, including memory decoding circuit and general I/O, Special I/O(EPA, Interrupt controller, Timer/Count, PWM generator) which is proper controller for the complex algorithm or operation program requiring so much memory capacity, So in this paper we fully digitized the vector control of PMSM included SVPWM Voltage controller using the intel 80296SA

  • PDF

Development of Surface EMG Sensor Prototype and Its Application for Human Elbow Joint Angle Extraction (표면 근전도 센서 프로토타입 개발 및 인간의 팔꿈치 관절 각도 추출 응용)

  • Yu, Hyeon-Jae;Lee, Hyun-Chul;Choi, Young-Jin
    • The Journal of Korea Robotics Society
    • /
    • v.2 no.3
    • /
    • pp.205-211
    • /
    • 2007
  • In this paper, the prototype of surface EMG (ElectroMyoGram) sensor is developed for the robotic rehabilitation applications, and the developed sensor is composed of the electrodes, analog signal amplifiers, analog filters, ADC (analog to digital converter), and DSP (digital signal processor) for coding the application example. Since the raw EMG signal is very low voltage, it is amplified by about one thousand times. The artifacts of amplified EMG signal are removed by using the band-pass filter. Also, the processed analog EMG signal is converted into the digital form by using ADC embedded in DSP. The developed sensor shows approximately the linear characteristics between the amplitude values of the sensor signals measured from the biceps brachii of human upper arm and the joint angles of human elbow. Finally, to show the performance of the developed EMG sensor, we suggest the application example about the real-time human elbow motion acquisition by using the developed sensor.

  • PDF