• Title/Summary/Keyword: Low vacuum environment

Search Result 122, Processing Time 0.022 seconds

Study on Establishment of the Noise Grade Criteria for Household Appliances (가전제품 소음등급 기준설정에 관한 연구)

  • Park, Hyungkyu;Lee, Jaewon;Lee, Wooseok;Han, Jinseok;Gu, Jinhoi
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.22 no.12
    • /
    • pp.1237-1242
    • /
    • 2012
  • No matter how low it might be, noise from home appliances in indoor environment cause displeasure for residents as it is produced nearby. Electronic goods including vacuum cleaner and washing machine generate high frequency noise, which interrupts TV-watching or conversations and cause noises between floors in apartment houses. In particular, refrigerators make constant noise late at night, hampering the study for exams and causing sleeplessness. Korea, despite the government's efforts to promote low-noise goods based on the noise test by corporation, there is a lack of standardization in the test method, test condition and measuring equipments. This is a major reason that lowers the reliability of low-noise products. At present, low-noise home appliances are certified with eco labeling in the nation but, only 7 brands of refrigerators, 4 brands of washing machines and 97 brands of air-conditioners obtained certification as of august, 2011. In addition, none of Kimchi-refrigerator and vacuum cleaner brands were approved as low-noise home appliances. This shows Korea's relatively underdeveloped market for low-noise products, which, in part, is because of the difficulties companies face in being certified with eco labeling as they should satisfy various requirements such as power-saving and eco-friendly design besides low-noise features. As a result, low-noise labeling for home appliances should be established for the revised noise and vibration management law and the study was carried out to establish low-noise labeling system for major noise sources including vacuum cleaner, washing machine, air-conditioner and refrigerator.

Parametric Study on the Capacity of Vacuum Pump for Tube Structure (튜브열차 구조물의 진공 펌프 용량에 관한 파라메타 연구)

  • Nam, Seong-Won
    • Journal of the Korean Society for Railway
    • /
    • v.13 no.5
    • /
    • pp.516-520
    • /
    • 2010
  • Parametric study has been conducted to calculate the capacity of vacuum pump system that will be used to maintain the pressure of the tube structure under atmosphere level. Recently many railroad researchers pay attention to the tube train system as one of the super high speed transportation system. To achieve the super high speed, the inside of tube system should be maintained at low pressure level. In the low pressure environment, it is well known that air resistance of train is drastically decreased. Vacuum pump system will be used to make low pressure state for tube structure, exhaust the leakage air and supplement additional vacuum pumping. As results of these studies, we get the lump capacity of vacuum pump for various parameters. These results can be applied to analyze the effects of the reduction of air resistance.

The Development of Single-Step UV-NIL Tool Using Low Vacuum Environment and Additive Air Pressure (저진공 Single-step UV 나노임프린트 장치 개발)

  • Kim K.D.;Jeong J.H.;Lee E.S.;Bo H.J.;Shin H.S.;Choi W.B.
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2006.05a
    • /
    • pp.155-156
    • /
    • 2006
  • UV-NIL is a promising technology for the fabrication of sub-100 nm features. Due to non-uniformity of the residual layer thickness (RLT) and a strong possibility of defects, many UV-NIL processes have been developed and some are commercially available at present, most are based on the 'step-and-repeat' nanoimprint technique, which employs a small-area stamp, much smaller than the substrate. This is mainly because, when a large-area stamp is used, it is difficult to obtain acceptable uniform residual layer thickness and/or to avoid defects such as air entrapment. As an attempt to enable UV_NIL with a large-area stamp for high throughput, we propose a new UV-NIL tool that is able to imprint 4 inch wafer in a low vacuum environment at a single step.

  • PDF

Preliminary Thermal Analysis for LEO Satellite Optical Payload's Thermal Vacuum Test (저궤도위성 광학탑재체의 지상 열진공 시험을 위한 예비 열해석)

  • Lee, Jongl-Yul;Huh, Hwan-Il;Kim, Sang-Ho;Chang, Su-Young;Lee, Deog-Gyu;Lee, Seung-Hoon;Choi, Hae-Jin
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.39 no.5
    • /
    • pp.466-473
    • /
    • 2011
  • The purpose of satellite thermal control design is to maintain all the elements of a spacecraft system within their temperature limits for all mission phases. The thermal analysis model for Low Earth Orbit satellite payload level simulation is established by considering thermal vacuum test environment condition, thermal vacuum chamber configuration, and satellite's payload inner thermal environment. The established thermal analysis model is used to determine thermal vacuum test conditions and test case requirements.

Development of Automatic Transmission Parts by Using Vacuum Carburizing Heat-treatment Technology (진공침탄 공정기술을 이용한 자동변속기 부품 개발)

  • Lee, Won-Beom;Moon, Gyung-Il;Cho, Yong-Ki;Lim, Kyung-Mook;Byun, Sang-Gyo
    • Journal of the Korean institute of surface engineering
    • /
    • v.43 no.5
    • /
    • pp.211-216
    • /
    • 2010
  • Vacuum carburizing process is well known process for its environment-friendly, low-cost, high-quality characteristics, compared with gas carburizing. In this study, a research was carried out to develop a process of vacuum carburizing for essential components of automotive transmission that is difficult to control its distortion. As a result, vacuum carburizing process is superior to gas carburizing in terms of cost, environment and quality.

Low Temperature Test of HWR Cryomodule

  • Kim, Heetae;Kim, Youngkwon;Lee, Min Ki;Park, Gunn-Tae;Kim, Wookang
    • Applied Science and Convergence Technology
    • /
    • v.25 no.3
    • /
    • pp.47-50
    • /
    • 2016
  • Low temperature test for half-wave resonator (HWR) cryomodule is performed at the superfluid helium temperature of 2 K. The effective temperature is defined for non-uniform temperature distribution. Helium leak detection techniques are introduced for cryogenic system. Experimental set up is shown to make the low temperature test for the HWR cryomodule. The cooldown procedure of the HWR cryomodule is shown from room temperature to 2 K. The cryomodules is precooled with liquid nitrogen and then liquid helium is supplied to the helium reservoirs and cavities. The pressure of cavity and chamber are monitored as a function of time. The vacuum pressure of the cryomodule is not increased at 2 K, which shows leak-tight in the superfluid helium environment. Static heat load is also measured for the cryomodule at 2.5 K.

A Comparative Experiment on Thermal Stress Failure of Vacuum Glazing applied in Curtain Wall at Spandrel area (커튼월 스팬드럴용 진공유리의 열파손에 대한 비교실험)

  • Kim, Seung-Chul;Yoon, Jong-Ho;Shin, U-Cheol;Ahn, Jung-Hyuk
    • KIEAE Journal
    • /
    • v.16 no.3
    • /
    • pp.121-128
    • /
    • 2016
  • Purpose: The vacuum glazing should constantly retain the gap in vacuum state to maintain high thermal performance. To do so, pillars are used to prevent the glazing from clinging to each other by the atmospheric pressure and therefore surface of the vacuum glazing is consistently affected by residual stress. The vacuum glazing could be applied to curtain wall systems at spandrel area to fulfill a rigorous domestic standard on U-value of the external wall. However, this can lead to high glazing temperature increase by heat concentration at a back panel and finally thermal stress breakage. This study experimentally determined weakness of the vacuum glazing systems on the thermal stress breakage and investigated effect of the residual stress. Method: The experiment first built two scale-down mock-up facilities that replicate the spandrel area in curtain wall, and then installed single low-e glass and vacuum glazing respectively. The two mock-up facilities were exposed to outside to induce the thermal stress breakage. Result: The experiment showed that the temperature occurred the thermal stress breakage was $114.4^{\circ}C$ for the single low-e glass and $118.9^{\circ}C$ for the vacuum glazing respectively. The result also showed the vacuum glazing reached the critical point earlier than the single low-e glass, which means that the vacuum glazing has high potential to occur the thermal shock breakage. In addition, the small temperature difference between two glazing indicates that the residual stress scarcely affects breakage of the vacuum glazing.

대형 열진공챔버용 극저온 모사장치 개발

  • Lee, Sang-Hoon;Cho, Hyok-Jin;Seo, Hee-Jun;Moon, Guee-Won;Choi, Seok-Weon
    • Aerospace Engineering and Technology
    • /
    • v.3 no.1
    • /
    • pp.103-108
    • /
    • 2004
  • The space environment is characterized such a severe condition as high vacuum and very low temperature. Since a satellite will be exposed such a space environment as soon as it goes into the its orbit, thermal vacuum test should be carried out to verify the performance of the satellite on the ground under the space environmental conditions. KARI has a thermal vacuum chamber with useful dimensions of ∮3.6m×L3m, in which KOMPSAT-1 and KOMPSAT-2 satellites were tested. But very large thermal vacuum chamber with useful dimensions of ∮8m×L10m has been needed to meet the future demand of large satellites. Generally, the thermal vacuum chamber can be divided into a vacuum system and a thermal system. Especially, a cryogenic system in the thermal system simulates very low temperature of -196℃ under the high vacuum condition. In this paper, we propose the new cryogenic system can be applied to the future large thermal vacuum chamber.

  • PDF

Design and Fabrication of a Vacuum Chamber for a Commercial Atomic Force Microscope

  • Park, Sang-Joon;Jeong, Yeon-Uk;Park, Soyeun;Lee, Yong Joong
    • Applied Science and Convergence Technology
    • /
    • v.23 no.2
    • /
    • pp.97-102
    • /
    • 2014
  • A vacuum chamber for a commercial atomic force microscope (AFM) is designed and fabricated. Only minimal modifications were made to an existing microscope in an effort to work in a vacuum environment, while most of the available AFM functionalities were kept intact. The optical alignment needed for proper AFM operations including a SLD (superluminescent diode) and a photodiode can be made externally without breaking the vacuum. A vacuum level of $5{\times}10^{-3}$ torr was achieved with a mechanical pump. An enhancement of the quality factor was observed along with a shift in the resonance frequency of a non-contact-mode cantilever in a vacuum. Topographical data of a calibration sample were also obtained in air and in a low vacuum using the non-contact mode and the results were compared.

Graphene Synthesized by Plasma Enhanced Chemical Vapor Deposition at Low-Temperature

  • Ma, Yifei;Kim, Dae-Kyoung;Xin, Guoqing;Chae, Hee-Yeop
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2012.08a
    • /
    • pp.248-248
    • /
    • 2012
  • Synthesis graphene on Cu substrate by plasma-enhanced chemical vapor deposition (PE-CVD) is investigated and its quality's affection factors are discussed in this work. Compared with the graphene synthesized at high temperature in chemical vapor deposition (CVD), the low-temperature graphene film by PE-CVD has relatively low quality with many defects. However, the advantage of low-temperature is also obvious that low melting point materials will be available to synthesize graphene as substrate. In this study, the temperature will be kept constant in $400^{\circ}C$ and the graphene was grown in plasma environment with changing the plasma power, the flow rate of precursors, and the distance between plasma generator coil and substrates. Then, we investigate the effect of temperature and the influence of process variables to graphene film's quality and characterize the film properties with Raman spectroscopy and sheet resistance and optical emission spectroscopy.

  • PDF