• Title/Summary/Keyword: Low tube voltage

Search Result 127, Processing Time 0.028 seconds

A Study on the Output Characteristics of High-Frequency Resonant Inverter Type for X-ray Generators in Short Exposure Time. (고주파 공진형 인버터 X선 장치의 단시간 출력특성에 관한 연구)

  • 이성길;임홍우;이상일;조금배;백형래
    • Proceedings of the KIPE Conference
    • /
    • 1998.07a
    • /
    • pp.129-133
    • /
    • 1998
  • This paper deals with a characteristic of output for high frequency resonant inverter type x-ray generator in short exposure time. In the same tube-voltage, the waveform is stable in long exposure time (200msec) but more decreasing exposure time (50msec), the waveform is distorted. The ripple factor of tube-voltage waveform distorted more and more increase tube-voltage and in this case output is also unstable. High-frequency resonant inverter type X-ray generator using PSU source which introduced in resent is stable tube-voltage waveform and low ripple factor.

  • PDF

Effect of Electric Fields on Flame Speed of Propagating Premixed Flames in Tube (전기장이 튜브내 예혼합화염 전파속도에 미치는 영향에 관한 연구)

  • Ryu, S.K.;Won, S.H.;Cha, M.S.;Chung, S.H.
    • 한국연소학회:학술대회논문집
    • /
    • 2006.04a
    • /
    • pp.137-143
    • /
    • 2006
  • The effect of electric fields on flame speed has been investigated experimentally by observing propagating premixed flames in a tube for methane/air mixtures. The flame speeds were measured in both the normal and micro gravity conditions to substantiate the measurements. The results show that the flame speeds were enhanced by both the AC and DC electric fields, as the flame approached to the high voltage electrode located on the one end of the tube. The enhancement of flame speed was proportional to the square root of the electric field intensity, defined as the voltage applied divided by the distance of flame from the high voltage electrode, when the electric field intensity is sufficiently large. When the electric field intensity was low, there existed critical intensities, below which the electric fields did not influence the flame speed. This critical electric field intensity correlated well with the flame speed.

  • PDF

A Study on Safety Management Inspection of Diagnostic X-ray System (진단용 엑스선 장치의 안전관리 검사에 관한 연구)

  • Lee, Hoo min;Kim, Hyeon ju
    • Journal of the Korean Society of Radiology
    • /
    • v.12 no.7
    • /
    • pp.887-893
    • /
    • 2018
  • The purpose of this study is to compare the performance of X-ray generators installed in hospitals and universities and apply the quality control items of diagnostic X-ray generators to recognize the importance of periodic performance management. First, the reproducibility and linearity test results showed that the PAE of the reproducibility evaluation was high for the GX-650 devices that met the acceptance criteria in all the experimental conditions and lacked the periodic quality control. In the linearity evaluation, when the tube voltage was set to 100 kVp, It was measured to deviate from the error. In addition, it was found that the PAE in the low-accuracy evaluation results relative to an X-ray tube voltage and tube current of the device low occurrence frequency. The HVL experiment was included in all of the devices at the HVL by tube voltage. Therefore, it is necessary to recognize the importance of quality control of all devices rather than hospital and laboratory, and to manage the device performance by actively managing the device, and to establish a short - term quality control system like special medical devices.

Irradiation of Intense Characteristic X-rays from Weakly Ionized Linear Plasma

  • Sato, Eiichi;Hayasi, Yasuomi;Tanaka, Etsuro;Mori, Hidezo;Kawai, Toshiaki;Takayama, Kazuyoshi;Ido, Hideaki
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2002.09a
    • /
    • pp.396-399
    • /
    • 2002
  • Intense quasi-monochromatic x-ray irradiation from the linear plasma target is described. The plasma x-ray generator employs a high-voltage power supply, a low-impedance coaxial transmission line, a high-voltage condenser with a capacity of about 200 nF, a turbo-molecular pump, a thyristor pulse generator as a trigger device, and a flash x-ray tube. The high-voltage main condenser is charged up to 55 kV by the power supply, and the electric charges in the condenser are discharged to the tube after triggering the cathode electrode. The x-ray tube is of a demountable triode that is connected to the turbo molecular pump with a pressure of approximately 1 mPa. As electron flows from the cathode electrode are roughly converged to the molybdenum target by the electric field in the tube, the weakly ionized plasma, which consists of metal ions and electrons, forms by the target evaporating. In the present work, the peak tube voltage was almost equal to the initial charging voltage of the main condenser, and the peak current was about 20 kA with a charging voltage of 55 kV. When the charging voltage was increased, the linear plasma x-ray source grew, and the characteristic x-ray intensities of K-series lines increased. The quite sharp lines such as hard x-ray lasers were clearly observed. The quasi-monochromatic radiography was performed by a new film-less computed radiography system.

  • PDF

A Study on the Development of a Transient Voltage Blocking Device for Info-communication Facilities (정보통신기기용 과도전압 차단장치의 개발에 관한 연구)

  • 한주순
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.23 no.2
    • /
    • pp.159-167
    • /
    • 1999
  • This paper presents a new transient voltage blocking device(TOBD)which low power and high frequency bandwidth to protect info-communication facilities from transient voltages. Conventional protection devices have some problems such as low frequency bandwidth low ener-gy capacity and high remnant voltage. in order to improve these limitations a hybrid type TOBD which consists of a gas tube avalanche diodes and junction type field effect transistor (JFETs) is developed. The TOBD differs from the conventional protection devices in configuration and JFETs are used as an active non-linear element and a high speed switching diode with low capacitance limited high current. Therefore the avalanche diode with low energy capacity are protected from the high current and the TOBD has a very small input capacitance. From the performance test using combination surge generator which can produce $1.2/50{\mu}m$ 4.2 kV/max, $8/20{\mu}m$ 2.1 kAmax it is confirmed that the proposed TOBD has an excellent protection per-formance in tight clamping voltage and limiting current characteristics.

  • PDF

Design of High Frequency Resonant Inverter Type X-Ray Generator (고주파 공진형 인버터식 X선 발생장치의 설계)

  • Lee, Seong-Gil;Park, Su-Gang;Baek, Hyeong-Rae;Jeong, Su-Bok
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.51 no.1
    • /
    • pp.34-39
    • /
    • 2002
  • Most X-ray generator had been used do rectifier type transformer high tension generator which is supplied in a clinical diagnosis. But it is difficult to miniaturize and become light weight. Also, because the ripple rate of tube voltage is high, X-ray generating efficiency is very low. Therefore, it is supplied gradually from abroad being developed high tension generator for inverter type X-ray generator which use semi-conductor switching element for electric power that have high speed switching ability to solved these problem. But, semi-conductor element of big capacity are used by X-ray tube's big consumption power and diffusion is difficult in the small size hospital because production cost is ascending by doing digital control through DSP and product price becomes expensive. Therefore, in this paper, design and manufactured CR type voltage divider for feedback control of tube voltage of high frequency resonance type inverter and high tension transformer for high frequency to apply economical diffusion type X-ray generator which have wide output voltage and load extent. It is Proved do X-ray generator and stability of X-ray tube's output characteristics through an experiment.

Design of High Frequency Resonant High-tension Transformer in Inverter Type X-Ray Generator (인버터식 X선발생장치용 고주파 공진형 고압변압기 등의 설계)

  • Lee, Seong-Kil;Choi, Sung-Kwan
    • Journal of radiological science and technology
    • /
    • v.24 no.2
    • /
    • pp.5-11
    • /
    • 2001
  • Most of X-ray generator had used rectifier type transformer with high tension generator which is supplied in a clinical diagnosis. Because the ripple rate of tube voltage is high, X-ray generating efficiency is very low. In these days, high tension generator for inverter type X-ray generator is being supplied from a broad which uses semi-conductor switching element for the electric power that have a high speed switching ability to solve these problem. But, semi-conductor element with large capacity is used with X-ray tube's large consumption power and diffusion is difficult in the small size hospital because production cost is going up by doing digital control through DSP. Therefore, this paper designed and manufactured CR type voltage divider for feedback control of tube voltage with high frequency resonance type inverter and for high tension transformer with high frequency. It was to make economical diffusion type X-ray generator which has wide output voltage and load extent. It was preyed that the X-ray generator had the stability of X-ray tube's output characteristics.

  • PDF

Tube Voltage, DNA Double-Strand Breaks, and Image Quality in Coronary CT Angiography

  • Zhu Xiao Lin;Fan Zhou;U. Joseph Schoepf;Balakrishnan Pillai;Chang Sheng Zhou;Wei Quan;Xue Qin Bao;Guang Ming Lu;Long Jiang Zhang
    • Korean Journal of Radiology
    • /
    • v.21 no.8
    • /
    • pp.967-977
    • /
    • 2020
  • Objective: To evaluate the effects of tube voltage on image quality in coronary CT angiography (CCTA), the estimated radiation dose, and DNA double-strand breaks (DSBs) in peripheral blood lymphocytes to optimize the use of CCTA in the era of low radiation doses. Materials and Methods: This study included 240 patients who were divided into 2 groups according to the DNA DSB analysis methods, i.e., immunofluorescence microscopy and flow cytometry. Each group was subdivided into 4 subgroups: those receiving CCTA only with different tube voltages of 120, 100, 80, or 70 kVp. Objective and subjective image quality was evaluated by analysis of variance. Radiation dosages were also recorded and compared. Results: There was no significant difference in demographic characteristics between the 2 groups and 4 subgroups in each group (all p > 0.05). As tube voltage decreased, both image quality and radiation dose decreased gradually and significantly. After CCTA, γ-H2AX foci and mean fluorescence intensity in the 120-, 100-, 80-, and 70-kVp groups increased by 0.14, 0.09, 0.07, and 0.06 foci per cell and 21.26, 9.13, 8.10, and 7.13 (all p < 0.05), respectively. The increase in the DNA DSB level in the 120-kVp group was higher than those in the other 3 groups (all p < 0.05), while there was no significant difference in the DSBs levels among these latter groups (all p > 0.05). Conclusion: The 100-kVp tube voltage may be optimal for CCTA when weighing DNA DSBs against the estimated radiation dose and image quality, with further reductions in tube voltage being unnecessary for CCTA.

A Study on Conductivity Characteristics of the Insulating Oil for X-ray Tube Housing (X선장치용(線裝置用) 절연유(絶緣油)의 도전특성(導電特性)에 관한 연구(硏究))

  • Kim, Young-Il;Lee, Duck-Chool;Chung, Yon-Tack
    • Journal of radiological science and technology
    • /
    • v.9 no.1
    • /
    • pp.73-81
    • /
    • 1986
  • This paper carried out an experiment on the characteristics of time, temperature, electric field and the dependense of electrode materials and gap length by the conduction current of the insulating oil used for x-ray tube housing. The obtained results can be summarized as following: 1. In the x-ray tube housing insulating oil with vacuum condition, conduction current is declined more than the x-ray tube housing insultaing oil with the air, and is held stable states. 2. At the low electric field the higher temperature of the x-ray tube housing insulating oil is increased, the more conduction current. 3. The dependence of electrode material is appeared at the low electric field and the short gap length than the high and the long with Fe> Cu >Al. 4. At the I-E characteristics, the low electric field than 1000 [V/cm] is appeared Ohm's law region, and the high become saturation region. 5. At the same electric field, the longer gap length become, the more conduction current is increased, and the same applied voltage, the longer, the less conduction current is decreased, the less low than high temperature x-ray tube housing insulating oil.

  • PDF

Design and Fabrication of Wide-band Transient Voltage Blocking Device (광대역 과도전압 차단장치의 설계 및 제작)

  • 송재용;이종혁;길경석
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 1999.05a
    • /
    • pp.330-334
    • /
    • 1999
  • This paper presents a new transient voltage blocking device (TBD) for commucation facilities with low power and high frequency bandwidth. Conventional protection devices have some problems such as low frequency bandwidth, low energy capacity and high remnant voltage. In order to improve these limitations, the new TBD, which consists of a gas tube, avalanche diodes and junction type field effect transistors (JFETs), was designed and fabricated JFETs were used as an active non-linear element and a high speed switching diode with low capacitance limits high current. Therefore the avalanche diodes with low energy capacity are protected from the high current, and the TBD has a very small input capacitance. From the performance test using surge generator, which can produce 1.2/50${\mu}\textrm{s}$ 4.2 k$V_{max}$, 8/20${\mu}\textrm{s}$ 2.1 kA$\sub$max/, it is confirmed that the proposed TBD has an excellent protection performance in tight clamping voltage and limiting current characteristics.

  • PDF